A Comparison of Endosseous Dental Implant Surfaces
The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Abstract
Endosseous dental implants are available with various surface characteristics ranging from relatively smooth machined surfaces to more roughened surfaces created by coatings, blasting by various substances, by acid treatments, or by combinations of the treatments. Studies characterizing these implants and surfaces include in vitro experimentation, animal studies, and human clinical trials. Both descriptive and functional testing of the bone‐implant interface includes histomorphometrics and biomechanical testing such as torque removal values and push out/pull out strength. Using these assays to evaluate and compare different surfaces, the data demonstrate that rough implant surfaces have increased bone‐toimplant contact and require greater forces to break the bone‐implant interface compared to more smooth surfaces. The objective of this report was to evaluate publications of human clinical experiences evaluating implant use in patients and to determine if differences existed in success rates of implants with relatively smooth surfaces compared to implants having roughened implant surfaces. Human trials were reviewed to determine the clinical efficacy of implants under various clinical indications. Synopsis tables were constructed and the experiences segregated by implant surface characteristics. Meta‐analyses were performed on all implants in all locations, on implants placed only in the maxilla or the mandible, and, finally, on implants placed in the maxilla compared to implants placed in the mandible. Evaluation of the data revealed that predictably high success rates can be achieved for implants with both rough and smooth titanium surfaces and for hydroxyapatite‐coated implants. When studies were clustered by specific indications or patient populations, rough surfaced implants had significantly higher success rates compared to implants with more smooth surfaces except in the case of single tooth replacements where the success rates were comparable. In general, implants placed in the mandible had significantly higher success rates than implants placed in the maxilla. However, in the partially edentulous patient group, titanium implants with a rough surface had significantly higher success rates in the maxilla compared to the mandible and, in cases of single tooth replacement, success rates were similar in the maxilla and in the mandible as was the case for hydroxyapatite‐coated implants. The documented advantage of implants with a roughened surface in animal and in vitro experiments has been demonstrated in clinical cases when studies were compared in which specific indications or patients were treated. Additionally, implants placed in the mandible have, in general, higher success rates than implants placed in the maxilla, with only a few exceptions noted. These data from human clinical experiences support the documented advantage of implants with a roughened surface in animal and in vitro experimentation and indicate that the magnitude of the advantage is significant for patient care. J Periodontol 1999;70:1523‐1539.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A 15-year study of osseointegrated implants in the treatment of the edentulous jaw
Adell, R., Lekholm, U., Rockler, B., & Brånemark, P.-I. (1981) · International Journal of Oral Surgery · doi:10.1016/s0300-9785(81)80077-4 · Cited by 4,816
Albrektsson, T., Brånemark, P.-I., Hansson, H.-A., & Lindström, J. (1981) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678108991776 · Cited by 2,690
Long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws.
Adell, R., Eriksson, B., Lekholm, U., Brånemark, P., & Jemt, T. (1990) · PubMed · Cited by 1,926
Intra-Osseous Anchorage of Dental Prostheses:I. Experimental Studies
Brånemark, P.-I., Breine, U., Adell, R., Hansson, B. O., Lindström, J., & Ohlsson, Å. (1969) · Scandinavian Journal of Plastic and Reconstructive Surgery · doi:10.3109/02844316909036699 · Cited by 1,811
Buser, D., Schenk, R. K., Steinemann, S., Fiorellini, J. P., Fox, C. H., & Stich, H. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250708 · Cited by 1,719
Buser, D., Mericske‐stern, R., Pierre Bernard, J. P., Behneke, A., Behneke, N., Hirt, H. P., Belser, U. C., & Lang, N. P. (1997) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1997.080302.x · Cited by 1,286
Martin, J. Y., Schwartz, Z., Hummert, T. W., Schraub, D. M., Simpson, J., Lankford, J., Dean, D. D., Cochran, D. L., & Boyan, B. D. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820290314 · Cited by 1,111
Self-citationThe Excessive Loss of Branemark Fixtures in Type IV Bone: A 5‐Year Analysis
Jaffin, R. A., & Berman, C. L. (1991) · Journal of Periodontology · doi:10.1902/jop.1991.62.1.2 · Cited by 1,049
Criteria for success of osseointegrated endosseous implants
Smith, D. E., & Zarb, G. A. (1989) · Journal of Prosthetic Dentistry · doi:10.1016/0022-3913(89)90081-4 · Cited by 966
Buser, D., Weber, H. ‐., & Lang, N. P. (1990) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1990.010105.x · Cited by 724
Cited by
Advancing dental implant surface technology – From micron- to nanotopography
Mendonça, G., Mendonça, D. B. S., Aragão, F. J. L., & Cooper, L. F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.05.012 · Cited by 990
Gittens, R. A., McLachlan, T., Olivares-Navarrete, R., Cai, Y., Berner, S., Tannenbaum, R., Schwartz, Z., Sandhage, K. H., & Boyan, B. D. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.01.029 · Cited by 827
Engineering biocompatible implant surfaces
Bauer, S., Schmuki, P., von der Mark, K., & Park, J. (2013) · Progress in Materials Science · doi:10.1016/j.pmatsci.2012.09.001 · Cited by 780
Macrophages, Foreign Body Giant Cells and Their Response to Implantable Biomaterials
Sheikh, Z., Brooks, P., Barzilay, O., Fine, N., & Glogauer, M. (2015) · Materials · doi:10.3390/ma8095269 · Cited by 701
Cochran, D. L., Buser, D., Ten Bruggenkate, C. M., Weingart, D., Taylor, T. M., Bernard, J., Peters, F., & Simpson, J. P. (2002) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2002.130204.x · Cited by 568
Self-citationEffects of implant surface coatings and composition on bone integration: a systematic review
Junker, R., Dimakis, A., Thoneick, M., & Jansen, J. A. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01777.x · Cited by 535
Baggi, L., Cappelloni, I., Di Girolamo, M., Maceri, F., & Vairo, G. (2008) · The Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(08)60259-0 · Cited by 535
Implant Surface Roughness and Bone Healing: a Systematic Review
Shalabi, M. M., Gortemaker, A., Hof, M. A. V., Jansen, J. A., & Creugers, N. H. J. (2006) · Journal of Dental Research · doi:10.1177/154405910608500603 · Cited by 531
Kunzler, T. P., Drobek, T., Schuler, M., & Spencer, N. D. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.01.019 · Cited by 518
Biomaterial and antibiotic strategies for peri‐implantitis: A review
Norowski, P. A., & Bumgardner, J. D. (2009) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31152 · Cited by 339
A role for surface topography in creating and maintaining bone at titanium endosseous implants
Cooper, L. F. (2000) · The Journal of Prosthetic Dentistry · doi:10.1067/mpr.2000.111966 · Cited by 336
Significance of Keratinized Mucosa in Maintenance of Dental Implants With Different Surfaces
Chung, D. M., Oh, T., Shotwell, J. L., Misch, C. E., & Wang, H. (2006) · Journal of Periodontology · doi:10.1902/jop.2006.050393 · Cited by 313
Nanoscale surface modifications of medically relevant metals: state-of-the art and perspectives
Variola, F., Brunski, J. B., Orsini, G., Tambasco de Oliveira, P., Wazen, R., & Nanci, A. (2011) · Nanoscale · doi:10.1039/c0nr00485e · Cited by 260
Ferrigno, N., Laureti, M., Fanali, S., & Grippaudo, G. (2002) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2002.130305.x · Cited by 246
Mustafa, K., Wroblewski, J., Lopez, B. S., Wennerberg, A., Hultenby, K., & Arvidson, K. (2001) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2001.120513.x · Cited by 245
Bornstein, M. M., Valderrama, P., Jones, A. A., Wilson, T. G., Seibl, R., & Cochran, D. L. (2008) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2007.01473.x · Cited by 234
Self-citationSinus Floor Elevation Using Osteotomes: A Systematic Review and Meta‐Analysis
Emmerich, D., Att, W., & Stappert, C. (2005) · Journal of Periodontology · doi:10.1902/jop.2005.76.8.1237 · Cited by 222
Ferrigno, N., Laureti, M., & Fanali, S. (2006) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2005.01192.x · Cited by 196
Ganeles, J., Zöllner, A., Jackowski, J., Ten Bruggenkate, C., Beagle, J., & Guerra, F. (2008) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2008.01626.x · Cited by 170
Comparative analysis of collagen membranes for the treatment of implant dehiscence defects
Oh, T., Meraw, S. J., Lee, E., Giannobile, W. V., & Wang, H. (2003) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2003.140111.x · Cited by 166
“It has been demonstrated that the level of new BIC is significantly influenced by implant surface roughness, being greater BIC in surfaceroughened implants compared to machined titanium surfaces (Buser et al. 1991; Stentz et al. 1997; Buser et al. 1998; Wennerberg et al. 1998; Cochran 1999).”
BackgroundEffect of Micrometer-Scale Roughness of the Surface of Ti6Al4V Pedicle Screws in Vitro and in Vivo
Schwartz, Z., Raz, P., Zhao, G., Barak, Y., Tauber, M., Yao, H., & Boyan, B. D. (2008) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/jbjs.g.00499 · Cited by 163
Takeuchi, K., Saruwatari, L., Nakamura, H. K., Yang, J., & Ogawa, T. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30227 · Cited by 159
Hamlet, S., Alfarsi, M., George, R., & Ivanovski, S. (2012) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2011.02325.x · Cited by 150
Surface morphology optimization for osseointegration of coated implants
Rungsiyakull, C., Li, Q., Sun, G., Li, W., & Swain, M. V. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.05.077 · Cited by 105
Metadata
- Authors
- Cochran, D. L.
- Venue
- Journal of Periodontology
- Publisher
- Wiley
- Published
- 1999-12
- Volume
- 70
- Issue
- 12
- Pages
- 1523-1539
- ISSN
- 0022-3492 (ISSN-L)
- 1943-3670
- OpenAlex
- W2107986553
- Cited by
- 329
- References
- 50
- FWCI
- 10.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.