The compressive behavior of bone as a two-phase porous structure
The DOI matches its Crossref record.
Abstract
Compression tests of human and bovine trabecular bone specimens with and without marrow in situ were conducted at strain rates of from 0.001 to 10.0 per second. A porous platen above the specimens allowed the escape of marrow during testing. The presence of marrow increased the strength, modulus, and energy absorption of specimens only at the highest strain rate of 10.0 per second. This enhancement of material properties at the highest strain rate was due primarily to the restricted viscous flow of marrow through the platen rather than the flow through the pores of the trabecular bone. In specimens without marrow, the strength was proportional to the square of the apparent density and the modulus was proportional to the cube of the apparent density. Both strength and modulus were approximately proportional to the strain rate raised to the 0.06 power. These power relationships, which were shown to hold for all bone in the skeleton, allow meaningful predictions of bone tissue strength and stiffness based on in vivo density measurements.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The compressive modulus and compressive strength are proportional to the strain rate raised to the power of 0.06 (100, 101).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [101]
Citations
Cited by
Items 401–500 of 1,002
Isaksson, H., Gröngröft, I., Wilson, W., van Donkelaar, C. C., van Rietbergen, B., Tami, A., Huiskes, R., & Ito, K. (2009) · Journal of Orthopaedic Research · doi:10.1002/jor.20725 · Cited by 73
Modeling of Biological Materials
Mollica, F., Rajagopal, K. R., & Preziosi, L. (2007) · Modeling and simulation in science, engineering & technology · doi:10.1007/b138320 · Cited by 80
Contact finite element stress analysis of the hip joint
Rapperport, D. J., Carter, D. R. P., & Schurman, D. J. (1985) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100030406 · Cited by 77
Self-citationEckstein, F., Müller‐Gerbl, M., Steinlechner, M., Kierse, R., & Putz, R. V. (1995) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100130215 · Cited by 77
Estimation of Physiologic Stresses with a Natural Tooth Considering Fibrous PDL Structure
Atmaram, G. H., & Mohammed, H. (1981) · Journal of Dental Research · doi:10.1177/00220345810600050301 · Cited by 77
The use of sparse CT datasets for auto-generating accurate FE models of the femur and pelvis
Shim, V., PITTO, R. P., Streicher, R., Hunter, P. J., & Anderson, I. A. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.11.018 · Cited by 76
Marquet, F., Aubry, J., Pernot, M., Fink, M., & Tanter, M. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/22/005 · Cited by 76
Laz, P. J., Stowe, J. Q., Baldwin, M. A., Petrella, A. J., & Rullkoetter, P. J. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.03.013 · Cited by 76
“Numerous studies have sought to define relationships between HU and density, density and Young’s modulus, and density and bone strength (e.g. Carter and Hayes, 1977; Bentzen et al., 1987; Hvid et al., 1989; Snyder and Schneider, 1991; Keller, 1994; Rho et al., 1995; Hernandez et al., 2001; Morgan…”
BackgroundFinite element modelling of polymethylmethacrylate flow through cancellous bone
Beaudoin, A. J., Mihalko, W. M., & KRAUSE, W. R. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90357-s · Cited by 76
Mechanical strength of tibial trabecular bone evaluated by X-ray computed tomography
Bentzen, S. M., Hvid, I., & Jorgensen, J. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90053-4 · Cited by 76
Yang, H., Ma, X., & Guo, T. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.01.004 · Cited by 75
Lerebours, C., Buenzli, P. R., Scheiner, S., & Pivonka, P. (2015) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-015-0705-x · Cited by 84
“These remodelling algorithms locally increase or decrease bone density depending on the tissue’s mechanical state [Carter and Hayes (1977); Carter and Beaupré (2001); Fyhrie and Carter (1986); Weinans et al (1992); Van der Meulen et al (1993); Pettermann et al (1997)].”
BackgroundMethodAnticipating bipedalism: trabecular organization in the newborn ilium
Cunningham, C. A., & Black, S. M. (2009) · Journal of Anatomy · doi:10.1111/j.1469-7580.2009.01073.x · Cited by 81
“…the 19th century (Ward, 1838; Von Mayer, 1867; Wolff, 1892, 1986; Evans, 1957), through seminal work in the past decades (Evans, 1973; Lanyon, 1974; Carter & Hayes, 1977; Gibson, 1985; Goldstein, 1987; Frost, 1990; Ciarelli et al. 1991; Biewener et al. 1996), to current research (Keaveny et al.…”
Williams, P. A., & Saha, S. (1996) · Annals of Biomedical Engineering · doi:10.1007/bf02667351 · Cited by 74
“Carter and Hayes (6,7) found that the compressive strength was related to the square of the density, and the strain rate was related to the 0.”
InfluentialGhosh, R., Pal, B., Ghosh, D., & Gupta, S. (2013) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2013.843674 · Cited by 74
Perilli, E., Baleani, M., Öhman‐Mägi, C., Baruffaldi, F., & Viceconti, M. (2007) · Bone · doi:10.1016/j.bone.2007.07.014 · Cited by 79
“Various methods have been reported for testing cancellous bone [2,29,37,39,46,47,60].”
MethodStructural analysis of the human tibia by tomographic (pQCT) serial scans
Capozza, R. F., Feldman, S., Mortarino, P., Reina, P. S., Schießl, H., Rittweger, J., Ferretti, J. L., & Cointry, G. R. (2010) · Journal of Anatomy · doi:10.1111/j.1469-7580.2009.01201.x · Cited by 89
“…and strength of the trabecular network: (i) increase proportionally to the cube and the square, respectively, of its apparent (Archimedean) density (Carter & Hayes, 1977), which is highly variable between sites; (ii) depend largely on the trabecular connectivity and directionality (which cannot be…”
BackgroundJanssen, D. W., Mann, K. A., & Verdonschot, N. J. J. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.08.020 · Cited by 74
“When assigning bone material properties based upon CT-grayscale, it is common to use a power law relating the bone density to a certain Young’s modulus (Carter and Hayes, 1977; Keller et al., 1994; Wirtz et al., 2000).”
MethodOn the development of an osseo-ligamentous finite element model of the human ankle joint
Bandak, F. A., Tannous, R. E., & Toridis, T. G. (2001) · International Journal of Solids and Structures · doi:10.1016/s0020-7683(00)00129-3 · Cited by 74
Mosekilde, L., & Mosekilde, L. (1988) · Bone · doi:10.1016/8756-3282(88)90030-0 · Cited by 80
Bone and its adaptation to mechanical loading: a review
Mellon, S., & Tanner, K. E. (2012) · International Materials Reviews · doi:10.1179/1743280412y.0000000008 · Cited by 87
Anatomic variation of the mechanical properties of the glenoid
Mansat, P., Baréa, C., Tho, M. H. B., Darmana, R., & Mansat, M. (1998) · Journal of Shoulder and Elbow Surgery · doi:10.1016/s1058-2746(98)90219-1 · Cited by 73
Effect of bone quality and implant surgical technique on implant stability quotient (ISQ) value
Yoon, H.-G., Heo, S., Koak, J., Kim, S., & Lee, S. (2011) · The Journal of Advanced Prosthodontics · doi:10.4047/jap.2011.3.1.10 · Cited by 73
Wear biomechanics in the slicing dentition of the giant horned dinosaur Triceratops
Erickson, G. M., Sidebottom, M. A., Kay, D. I., Turner, K. T., Ip, N., Norell, M. A., Sawyer, W. G., & Krick, B. A. (2015) · Science Advances · doi:10.1126/sciadv.1500055 · Cited by 56
Ferretti, J. L., Gaffuri, O., Capozza, R. F., Cointry, G. R., Bozzini, C., Olivera, M. I., Zanchetta, J., & Bozzini, C. (1995) · Bone · doi:10.1016/8756-3282(95)80021-h · Cited by 73
Surgical Variables Affect the Mechanics of a Hip Resurfacing System
Long, J. P., & Bartel, D. L. (2006) · Clinical Orthopaedics and Related Research · doi:10.1097/01.blo.0000238873.09390.6f · Cited by 81
Theory and numerics of geometrically non‐linear open system mechanics
Ellen Kuhl, A., & Steinmann, P. (2003) · International Journal for Numerical Methods in Engineering · doi:10.1002/nme.827 · Cited by 73
Burr, D. B. (1980) · American Journal of Physical Anthropology · doi:10.1002/ajpa.1330230508 · Cited by 73
Prediction of mandibular bone remodelling induced by fixed partial dentures
Field, C., Li, Q., Li, W., Thompson, M., & Swain, M. V. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.02.016 · Cited by 72
“In this paper, we adopted the following equation from (Carter and Hayes, 1977):”
MethodO'Brien, C. A., Jilka, R. L., Fu, Q., Stewart, S., Weinstein, R. S., & Manolagas, S. C. (2005) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00029.2005 · Cited by 71
“Thus the relationship of strength to BMD is not linear, and small changes in BMD can lead to much larger changes in strength (4, 8, 53).”
BackgroundPauchard, Y., Fitze, T., Browarnik, D., Eskandari, A., Pauchard, I., Enns-Bray, W. S., Pálsson, H., Sigurdsson, S. O., Ferguson, S. J., Harris, T. B., et al. (2016) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2016.1181173 · Cited by 81
“The ultimate stress was defined based on element apparent density using the equation proposed by Carter and Hayes (1977).”
MethodCheong, V. S., Fromme, P., Mumith, A., Coathup, M. J., & Blunn, G. W. (2018) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2018.07.019 · Cited by 72
“2, and used to update the stiffness matrix using a density-modulus relationship (E = 3790(3)) [31].”
MethodCalcium phosphate bone cements
Ginebra, M. (2008) · Elsevier eBooks · doi:10.1533/9781845695170.2.206 · Cited by 72
Andersen, K. L., Mortensen, H., Pedersen, E. H., & Melsen, B. (1991) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(91)90111-j · Cited by 72
New insights into nickel-free superelastic titanium alloys for biomedical applications
Ramezannejad, A., Xu, W., Xiao, W. L., Fox, K. E., Liang, D., & Qian, M. (2019) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2019.100783 · Cited by 74
Mechanobiological prediction of proximal femoral deformities in children with cerebral palsy
Carriero, A., Jonkers, I., & Shefelbine, S. J. (2010) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255841003682505 · Cited by 78
Porous silicon nitride ceramics designed for bone substitute applications
Bodišová, K., Kašiarová, M., Domanická, M., Hnatko, M., Lenčéš, Z., Nováková, Z. V., Vojtaššák, J., Gromošová, S., & Šajgalík, P. (2013) · Ceramics International · doi:10.1016/j.ceramint.2013.04.015 · Cited by 71
A micro-mechanics model of dentin mechanical properties
Qin, Q., & Swain, M. V. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.12.042 · Cited by 79
“It was also confirmed that the third power law relationship between modulus and mineral content presented in [7] could best fit the data obtained.”
BackgroundInfluence of loading and activity on the primary stability of cementless tibial trays
Taylor, M., Barrett, D. S., & Deffenbaugh, D. L. (2012) · Journal of Orthopaedic Research® · doi:10.1002/jor.22056 · Cited by 71
“Bone material properties were applied to the model using the freeware Bonemat(35) using established apparent density–modulus relationships.(36) The LCS Complete and LCS Complete Duofix trays were assumed to manufactured from cobalt–chrome (E 1⁄4 200 GPa); the PFC Sigma was assumed to be titanium alloy (E 1⁄4 110 GPa).”
MethodCompressive properties of trabecular bone in the distal femur
Burgers, T., Mason, J., Niebur, G. L., & Ploeg, H. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.11.018 · Cited by 77
“, 1988) or cubic (Carter and Hayes, 1977) relationship. Morgan et al. (2003) found that modulus–density relationships differ between anatomic locations.”
BackgroundInfluentialOn the Relation of Bone Mineral Density and the Elastic Modulus in Healthy and Pathologic Bone
Nobakhti, S., & Shefelbine, S. J. (2018) · Current Osteoporosis Reports · doi:10.1007/s11914-018-0449-5 · Cited by 78
Helgason, B., Gilchrist, S. E., Ariza, O., Vogt, P., Enns-Bray, W. S., Widmer, R. P., Fitze, T., Pálsson, H., Pauchard, Y., Guy, P., et al. (2016) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.03.006 · Cited by 70
Design of complex bone internal structure using topology optimization with perimeter control
Park, J., Sutradhar, A., Shah, J. J., & Paulino, G. H. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.01.001 · Cited by 70
Cements as bone repair materials
Ginebra, M. (2009) · Elsevier eBooks · doi:10.1533/9781845696610.2.271 · Cited by 70
Tanaka, E. I., Rodrigo, D. P., Miyawaki, Y., Lee, K., Yamaguchi, K., & Tanne, K. (2000) · Journal of Oral Rehabilitation · doi:10.1046/j.1365-2842.2000.00597.x · Cited by 78
Tissakht, M., Ahmed, A. M., & Chan, K. C. (1996) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100140515 · Cited by 70
Microarchitectural adaptations in aging and osteoarthrotic subchondral bone issues
Ding, M. L. (2010) · Acta Orthopaedica · doi:10.3109/17453671003619037 · Cited by 76
Birmingham, E., Grogan, J. A., Niebur, G. L., McNamara, L. M., & McHugh, P. E. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0714-1 · Cited by 69
Chen, S.-H., Chiang, M.-C., Hung, C.-H., Lin, S., & Chang, H.-W. (2013) · The Knee · doi:10.1016/j.knee.2013.03.006 · Cited by 69
“In general, the ost-2 was the most common condition of the implant-induced osteoporosis at the periprosthetic region [26].”
BackgroundHao, Z., Wan, C., Gao, X., & Ji, T. (2011) · Journal of Biomechanical Engineering · doi:10.1115/1.4005223 · Cited by 69
“According to the paper by Carter and Hayes [29], the relationship of density and Young’s modulus was as follows:”
BIOMECHANICAL ISSUES IN BONE TRANSPLANTATION
Davy, D. T. (1999) · Orthopedic Clinics of North America · doi:10.1016/s0030-5898(05)70108-5 · Cited by 69
Finite element modeling of the glenoid component: Effect of design parameters on stress distribution
Friedman, R. J., LaBerge, M., Dooley, R. L., & O'Hara, A. L. (1992) · Journal of Shoulder and Elbow Surgery · doi:10.1016/s1058-2746(09)80068-2 · Cited by 69
DeVocht, J. W., Goel, V. K., Zeitler, D. L., & Lew, D. (1996) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/s0278-2391(96)90259-1 · Cited by 69
Cong, A. X., den Buijs, J. O., & Dragomir‐Daescu, D. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.09.018 · Cited by 82
“Various power law equations, obtained from uniaxial testing of small bone coupons with a range of densities have been previously used to describe the elasticitydensity relationship in QCT/FEA models [13-15].”
BackgroundMethodInfluentialTerrier, A., Ramondetti, S., Merlini, F., Pioletti, D. P., & Farron, A. (2010) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2010.06.006 · Cited by 68
Wren, T. A. L., Yerby, S. A., Beaupré, G. S., & Carter, D. R. P. (2001) · Clinical Biomechanics · doi:10.1016/s0268-0033(01)00033-x · Cited by 68
Self-citationJiang, S., Jiang, L., & Dai, L. (2006) · Osteoporosis International · doi:10.1007/s00198-006-0165-3 · Cited by 68
“Although BMD is currently the best in vivo surrogate of fracture risk widely available, estimated to explain 50– 80% of the variance in bone strength [46, 47], other skeletal features such as bone geometry and microarchitecture also affect bone strength [48–51].”
BackgroundViscoelastic behaviour and failure of bovine cancellous bone under constant strain rate
Guedes, R. M., Simöes, J. A., & Morais, J. J. L. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.11.005 · Cited by 76
Cook, S. D., Klawitter, J. J., & WEINSTEIN, A. M. (1981) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820150612 · Cited by 68
Computational simulation of internal bone remodeling
Pettermann, H. E., Reiter, T. J., & Rammerstorfer, F. G. (1997) · Archives of Computational Methods in Engineering · doi:10.1007/bf02737117 · Cited by 77
Castilho, M. D., Rodrigues, J. M. C., Pires, I., Gouveia, B., Pereira, M. F. C., Moseke, C., Gröll, J., Ewald, A., & Vorndran, E. (2015) · Biofabrication · doi:10.1088/1758-5090/7/1/015004 · Cited by 71
“These strengths were above (for dry state) andwithin (immersed for 14 d) the range of the ultimate tensile (1–5MPa) and compressive strengths (4–12MPa) of cancellous bone [63].”
BackgroundResultBarak, M. M., & Black, M. A. (2017) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2017.12.010 · Cited by 67
“Previous studies have demonstrated that adding a bone marrow component to an unconfined trabecular bone model will not affect the sample’s mechanical properties (Carter and Hayes, 1977; Pugh et al., 1973; Swanson and Freeman, 1966; Yoon et al., 2014).”
InfluentialPhysical and mechanical properties of calf lumbosacral trabecular bone
Swartz, D. E., Wittenberg, R. H., Shea, M., White, A. A., & Hayes, W. C. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90022-f · Cited by 75
Self-citationBandak, F. A., Vorst, M. J. V., Stuhmiller, L. M., MLAKAR, P. F., CHILTON, W. E., & Stuhmiller, J. H. (1995) · Journal of Neurotrauma · doi:10.1089/neu.1995.12.679 · Cited by 67
“Keyak and co-workers (1990) presented a relationship between Hounsfield units (HU) and physical material properties.”
InfluentialA comparative study on complete and implant retained denture treatments – A biomechanics perspective
Chen, J., Ahmad, R., Suenaga, H., Li, W., Swain, M. V., & Li, Q. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.11.043 · Cited by 70
Fazzalari, N. L., Kuliwaba, J. S., & Forwood, M. R. (2002) · Bone · doi:10.1016/s8756-3282(02)00906-7 · Cited by 72
In vivo characterization of glenoid with use of computed tomography
Couteau, B., Mansat, P., Mansat, M., Darmana, R., & Egan, J. (2001) · Journal of Shoulder and Elbow Surgery · doi:10.1067/mse.2001.112884 · Cited by 66
Infiltration of Silica Inside Fibrillar Collagen
Niu, L., Jiao, K., Qi, Y., Yiu, C. K. Y., Ryou, H., Arola, D. D., Chen, J., Breschi, L., Pashley, D. H., & Tay, F. R. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201105114 · Cited by 65
Computational method for determination of bone and joint loads using bone density distributions
Fischer, K. J., Jacobs, C. R., & Carter, D. R. P. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00182-4 · Cited by 72
Self-citationBernard, S., Schneider, J., Varga, P., Laugier, P., Raum, K., & Grimal, Q. (2015) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-015-0689-6 · Cited by 65
Welch, R. D., Berry, B. H., Crawford, K., Zhang, H., Zobitz, M. E., Bronson, D. G., & Krishnan, S. G. (2002) · Journal of Orthopaedic Research® · doi:10.1016/s0736-0266(01)00124-3 · Cited by 65
Mourtada, F., Beck, T., Hauser, D. L., Ruff, C. B., & Bao, G. (1996) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100140319 · Cited by 65
Microdamage propagation in trabecular bone due to changes in loading mode
Wang, X., & Niebur, G. L. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.02.007 · Cited by 71
“Removing the marrow should not affect the mechanical properties at the strain rate used here (Carter and Hayes, 1977).”
BackgroundCancellous Bone Strength at the Proximal Human Tibia
Hvid, I., & Jensen, J. (1984) · Engineering in Medicine · doi:10.1243/emed_jour_1984_013_007_02 · Cited by 65
Cavities in the compact bone in tetrapods and fish and their effect on mechanical properties
Currey, J. D., & Shahar, R. (2013) · Journal of Structural Biology · doi:10.1016/j.jsb.2013.04.012 · Cited by 67
Jiang, S., Jiang, L., & Dai, L. (2007) · Calcified Tissue International · doi:10.1007/s00223-006-0085-4 · Cited by 64
“BMD is the current gold standard measurement of osteoporosis and the paramount predictor of fracture widely available, estimated to explain 50 80% of the variance in bone strength [23, 24].”
BackgroundHistomorphometric Comparison of 3 Osteotomy Techniques
Slete, F. B., Olin, P. S., & Prasad, H. (2018) · Implant Dentistry · doi:10.1097/id.0000000000000767 · Cited by 64
Calcitonin Alters Bone Quality in Beagle Dogs
Pienkowski, D., Doers, T. M., Monier‐Faugere, M., Geng, Z., Pleshko, N. L., Boskey, A. L., & Malluche, H. H. (1997) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1997.12.11.1936 · Cited by 80
“1 mm/s((41)) by use of a computer-controlled servohydraulic uniaxial materials testing system (Instron model 1331).”
MethodCotton, J. R., Winwood, K. L., Zioupos, P., & Taylor, M. (2004) · Journal of Biomechanical Engineering · doi:10.1115/1.1865188 · Cited by 72
Novel mechanically competent polysaccharide scaffolds for bone tissue engineering
Kumbar, S. G., Toti, U. S., Deng, M., James, R., Laurencin, C. T., Aravamudhan, A., Harmon, M., & Ramos, D. M. (2011) · Biomedical Materials · doi:10.1088/1748-6041/6/6/065005 · Cited by 67
“The observed stress–strain behavior is similar to that of native bone identified by a linear elastic region and less-stiff post-yield region [37].”
BackgroundTrabelsi, N., & Yosibash, Z. (2011) · Journal of Biomechanical Engineering · doi:10.1115/1.4004180 · Cited by 73
Helwig, P., Faust, G., Hindenlang, U., Hirschmüller, A., Konstantinidis, L., Bahrs, C., Südkamp, N. P., & Schneider, R. (2009) · Injury · doi:10.1016/j.injury.2008.08.016 · Cited by 63
Machado, A., Soares, C. J., Reis, B., Bicalho, A., Raposo, L. H. A., & Soares, P. (2017) · Operative Dentistry · doi:10.2341/14-195-l · Cited by 72
Peters, A. E., Akhtar, R., Comerford, E. J., & Bates, K. T. (2018) · PeerJ · doi:10.7717/peerj.4298 · Cited by 68
Understanding Rib Fracture Patterns: Incomplete and Buckle Fractures
Love, J., & Symes, S. A. (2004) · Journal of Forensic Sciences · doi:10.1520/jfs2004175 · Cited by 76
Szivek, J. A., THOMPSON, J. D., & Benjamin, J. B. (1995) · Journal of Applied Biomaterials · doi:10.1002/jab.770060207 · Cited by 63
Load Sharing Within a Human Lumbar Vertebral Body Using the Finite Element Method
Cao, K., Grimm, M. J., & Yang, K.-H. (2001) · Spine · doi:10.1097/00007632-200106150-00011 · Cited by 63
“A value of 11,032 MPa was assigned to the cortical modulus, which was based on an average of several studies.(6,21,34,37) The endplates were modeled with two different regions: a thinner central region and a thicker peripheral region.”
MethodKatzenberger, M. J., Albert, D. L., Agnew, A. M., & Kemper, A. R. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.103410 · Cited by 66
Bone tissue remodelling analysis considering a radial point interpolator meshless method
Belinha, J., Jorge, R. N., & Dinis, L. M. J. S. (2012) · Engineering Analysis with Boundary Elements · doi:10.1016/j.enganabound.2012.05.009 · Cited by 62
Miura, M., Nakamura, J., Matsuura, Y., Wako, Y., Suzuki, T., Hagiwara, S., Orita, S., Inage, K., Kawarai, Y., Sugano, M., et al. (2017) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-017-1898-1 · Cited by 62
“2a), Carter [30] (Fig.”
Rahmanpanah, H., Mouloodi, S., Burvill, C. R., Gohery, S., & Davies, H. M. S. (2020) · International Journal of Engineering Science · doi:10.1016/j.ijengsci.2020.103319 · Cited by 62
Hu, K., Qiguo, R., Fang, J., & Mao, J. J. (2002) · Medical Engineering & Physics · doi:10.1016/s1350-4533(02)00191-1 · Cited by 62
“The biomechanical properties of the cortical and cancellous bone [19,20], and the elastic properties of the articular disc of the mandible [21], were defined as shown in Table 2.”
Harrigan, T. P., & Hamilton, J. J. (1993) · International Journal for Numerical Methods in Engineering · doi:10.1002/nme.1620360508 · Cited by 62
Yeni, Y. N., & Fyhrie, D. P. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00122-2 · Cited by 72
Martínez-Reina, J., Domínguez, J., & García-Aznar, J. M. (2011) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-010-0236-4 · Cited by 61
“Carter and Hayes (1977) obtained an exponent of 3.”
BackgroundSchwiedrzik, J. J., Gross, T., Bina, M., Pretterklieber, M. L., Zysset, P. K., & Pahr, D. H. (2015) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2739 · Cited by 64
Rao, A. A., & Dumas, G. A. (1991) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(91)90061-b · Cited by 61
Dependence of elastic constants of an anisotropic porous material upon porosity and fabric
Turner, C. H., & Cowin, S. C. (1987) · Journal of Materials Science · doi:10.1007/bf01161180 · Cited by 60
Belinha, J., Jorge, R. N., & Dinis, L. M. J. S. (2012) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2012.654783 · Cited by 60
Bach-Gansmo, F. L., Brüel, A., Jensen, M. V., Ebbesen, E. N., Birkedal, H., & Thomsen, J. S. (2016) · Bone · doi:10.1016/j.bone.2016.07.003 · Cited by 62
Metadata
- Authors
- Carter, D., & Hayes, W.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1977-10
- Volume
- 59
- Issue
- 7
- Pages
- 954-962
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W1901463649
- Semantic Scholar
- cc21d6cd590fb46c2bd9cfd768da63c8012862ee
- Cited by
- 2,001
- References
- 0
- Citations by year
- 2026: 30 · 2025: 31 · 2024: 41 · 2023: 40 · 2022: 60 · 2021: 61 · 2020: 57 · 2019: 66 · 2018: 59 · 2017: 55 · 2016: 55 · 2015: 67 · 2014: 79 · 2013: 68 · 2012: 67
- FWCI
- 18.23
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Bone and Joint Surgery (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Physical Sciences › Engineering › Mechanical Engineering › Cellular and Composite Structures
- Keywords
- trabecular bone, strain rate sensitivity, bone stiffness, energy absorption, marrow, porous structure, apparent density, human bone, bovine bone
- MeSH terms
- Animals, Bone and Bones, Cattle, Humans, Stress, Mechanical, Tensile Strength
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.