The compressive behavior of bone as a two-phase porous structure
The DOI matches its Crossref record.
Abstract
Compression tests of human and bovine trabecular bone specimens with and without marrow in situ were conducted at strain rates of from 0.001 to 10.0 per second. A porous platen above the specimens allowed the escape of marrow during testing. The presence of marrow increased the strength, modulus, and energy absorption of specimens only at the highest strain rate of 10.0 per second. This enhancement of material properties at the highest strain rate was due primarily to the restricted viscous flow of marrow through the platen rather than the flow through the pores of the trabecular bone. In specimens without marrow, the strength was proportional to the square of the apparent density and the modulus was proportional to the cube of the apparent density. Both strength and modulus were approximately proportional to the strain rate raised to the 0.06 power. These power relationships, which were shown to hold for all bone in the skeleton, allow meaningful predictions of bone tissue strength and stiffness based on in vivo density measurements.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The compressive modulus and compressive strength are proportional to the strain rate raised to the power of 0.06 (100, 101).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [101]
Citations
Cited by
Items 601–700 of 1,002
Baron, C., Talmant, M., & Laugier, P. (2007) · The Journal of the Acoustical Society of America · doi:10.1121/1.2759165 · Cited by 58
Ariza, O., Gilchrist, S. E., Widmer, R. P., Guy, P., Ferguson, S. J., Cripton, P. A., & Helgason, B. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.11.042 · Cited by 53
Mechanical analysis of percutaneous sacroplasty using CT image based finite element models
Anderson, D., & Cotton, J. R. (2006) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.03.008 · Cited by 48
Varga, P., Grünwald, L., Inzana, J. A., & Windolf, M. (2017) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2017.07.004 · Cited by 48
Zanetti, E. M., Ciaramella, S., Calì, M., Pascoletti, G., Martorelli, M., Asero, R., & Watts, D. C. (2018) · Dental Materials · doi:10.1016/j.dental.2018.05.016 · Cited by 48
Cai, X., Follet, H., Peralta, L. M., Gardegaront, M., Farlay, D., Gauthier, R., Yu, B., Gineyts, É., Olivier, C., Langer, M., et al. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.03.043 · Cited by 49
Rogge, R., Adams, B. D., & Goel, V. K. (2002) · The Journal Of Hand Surgery · doi:10.1053/jhsu.2002.29485 · Cited by 48
Distribution of bone mineral density and bone strength of the proximal humerus
Saitoh, S., Nakatsuchi, Y., Latta, L. L., & Milne, E. L. (1994) · Journal of Shoulder and Elbow Surgery · doi:10.1016/s1058-2746(09)80041-4 · Cited by 48
Magnetic Resonance Imaging Measurements of Bone Density and Cross-Sectional Geometry
Hong, J., Hipp, J. A., Mulkern, R. V., Jaramillo, D., & Snyder, B. D. (2000) · Calcified Tissue International · doi:10.1007/s002230050015 · Cited by 48
“Several studies have demonstrated that the elastic and shear moduli of bone are governed by power law and linear functions of apparent bone density [5, 6]; therefore, noninvasive methods capable of measuring bone density and cross-sectional bone geometry may be used to predict fracture risk through lytic bone tumors,…”
BackgroundScannell, P. T., & Prendergast, P. J. (2009) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.11.007 · Cited by 58
Biomechanics of Bone and Fractures
Radasch, R. M. (1999) · Veterinary Clinics of North America Small Animal Practice · doi:10.1016/s0195-5616(99)50102-2 · Cited by 48
Fatigue behavior of the equine third metacarpus: Mechanical property analysis
Gibson, V. A., Stover, S. M., Martin, R. B., Gibeling, J. C., Willits, N. H., Gustafson, M. B., & Griffin, L. V. (1995) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100130609 · Cited by 55
Fatigue Microdamage in Bovine Trabecular Bone
Moore, T. L. A., & Gibson, L. J. (2003) · Journal of Biomechanical Engineering · doi:10.1115/1.1631584 · Cited by 47
A novel approach to estimate trabecular bone anisotropy using a database approach
Hazrati, J., Ito, K., Cataldi, M., Taddei, F., & van Rietbergen, B. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.07.042 · Cited by 50
“Empirical power–law relationships are then used to derive the elastic and strength properties (Carter and Hayes, 1977; Helgason et al., 2008; Keller, 1994; Lotz et al., 1991; Wirtz et al., 2000; Zannoni et al., 1999).”
MethodYao, J. P., Turteltaub, S., & Ducheyne, P. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.06.036 · Cited by 47
Metal vs bioabsorbable interference screws: Initial fixation
Beevers, D. J. (2003) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/095441103762597746 · Cited by 47
A Model for the Implant-Bone Interface Characteristics of Porous Dental Implants
Cook, S. D., Klawitter, J. J., & WEINSTEIN, A. M. (1982) · Journal of Dental Research · doi:10.1177/00220345820610080201 · Cited by 47
Mechanical properties of trabecular bone within and adjacent to osseous metastases
Hipp, J. A., Rosenberg, A. E., & Hayes, W. C. (1992) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650071008 · Cited by 47
Self-citationComputed tomography and automated image analysis of prehistoric femora
Sumner, D. R., Mockbee, B., Morse, K., Cram, T. R., & Pitt, M. J. (1985) · American Journal of Physical Anthropology · doi:10.1002/ajpa.1330680209 · Cited by 47
Development of Adult and Elderly FE Thorax Skeletal Models
Ito, O., Dokko, Y., & Ohashi, K. (2009) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/2009-01-0381 · Cited by 50
Field, C., Li, Q., Li, W., Thompson, M., & Swain, M. V. (2011) · Journal of Dentistry · doi:10.1016/j.jdent.2011.10.003 · Cited by 48
Effect of a supercritical CO2 based treatment on mechanical properties of human cancellous bone
Mitton, D., Rappeneau, J., & Bardonnet, R. (2005) · European Journal of Orthopaedic Surgery & Traumatology · doi:10.1007/s00590-005-0250-x · Cited by 46
“The compressive test was performed at low speed 10 3 s 1=5 mm min 1 which is below 10 s 1 the limit found by Carter and Hayes [3] to avoid viscoelastic effect due to bone marrow.”
MethodMouloodi, S., Rahmanpanah, H., Gohari, S., Burvill, C., & Davies, H. (2022) · Journal of The Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2022.105079 · Cited by 37
Goldberg, V. M., & Akhavan, S. (2005) · Humana Press eBooks · doi:10.1385/1-59259-863-3:057 · Cited by 46
On the Optimality of Bone Microstructure
Sigmund, O. (2005) · Kluwer Academic Publishers eBooks · doi:10.1007/0-306-46939-1_20 · Cited by 46
Perillo‐Marcone, A., Ryd, L., Johnsson, K., & Taylor, M. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.004 · Cited by 53
A parametric analysis of fixation post shape in tibial knee prostheses
Au, A. G., Liggins, A. B., Raso, V. J., & Amirfazli, A. (2004) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2004.09.010 · Cited by 60
Mapping anisotropy of the proximal femur for enhanced image based finite element analysis
Enns-Bray, W. S., Owoc, J. S., Nishiyama, K. K., & Boyd, S. K. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.08.020 · Cited by 52
Abraham, A. C., Agarwalla, A., Yadavalli, A., Liu, J. Y., & Tang, S. Y. (2016) · Bone · doi:10.1016/j.bone.2016.03.013 · Cited by 47
Fleps, I., Enns-Bray, W. S., Guy, P., Ferguson, S. J., Cripton, P. A., & Helgason, B. (2018) · PLoS ONE · doi:10.1371/journal.pone.0200952 · Cited by 45
Wang, M., & Yang, N. (2018) · Scientific Reports · doi:10.1038/s41598-018-25229-7 · Cited by 45
Ghaziani, A. O., Soheilifard, R., & Kowsar, S. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.104426 · Cited by 45
Mitton, D., Cendre, E., Roux, J.-P., ARLOT, M. E., Peix, G., Rumelhart, C., Babot, D., & Meunier, P. J. (1998) · Bone · doi:10.1016/s8756-3282(98)00036-2 · Cited by 55
“Significant relationships between measures of density and mechanical properties of trabecular bone have been reported.(2,5,10,14,16,18,27)Unfortunately, the trabecular bone heterogeneity contributes to significant unexplained variance of the mechanical properties when predicted using scalar measures of mass or density.”
BackgroundStress analyses of joint arthroplasty in the proximal humerus
Orr, T. E., & Carter, D. R. P. (1985) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100030313 · Cited by 45
Self-citationTanase, C. E., Sartoris, A., Popa, M., Vereștiuc, L., Unger, R. E., & Kirkpatrick, C. J. (2013) · Biomedical Materials · doi:10.1088/1748-6041/8/2/025002 · Cited by 47
Tooth displacement due to occlusal contacts: a three‐dimensional finite element study
de Oliveira, S. G., Seraidarian, P. I., Landre, J., Oliveira, D. D., & Cavalcanti, B. N. (2006) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.2006.01670.x · Cited by 45
“In addition, a 0Æ30 Poisson coefficient and 14 500 MPa elastic modulus characteristic of cancellous bone were considered for the whole bone structure (21).”
BackgroundMethodLin, C., Chang, S.-H., Wang, J., & Chang, W.-J. (2006) · Journal of Dentistry · doi:10.1016/j.jdent.2005.12.011 · Cited by 45
Skinner, H. B., Kim, A. S., Keyak, J. H., & Mote, C. D. (1994) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100120412 · Cited by 45
Mechanical characterization of injection-molded macro porous bioceramic bone scaffolds
Vivanco, J. F., Aiyangar, A. K., Araneda, A., & Ploeg, H. (2012) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2012.02.003 · Cited by 44
Janssen, D. W., Mann, K. A., & Verdonschot, N. J. J. (2009) · Journal of Orthopaedic Research® · doi:10.1002/jor.20882 · Cited by 44
Computational analyses of different intervertebral cages for lumbar spinal fusion
Bashkuev, M., Checa, S., Pozo, S. P., Duda, G. N., & Schmidt, H. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.06.024 · Cited by 44
Ricken, T., Schwarz, A., & Bluhm, J. (2006) · Computational Materials Science · doi:10.1016/j.commatsci.2006.03.025 · Cited by 44
Tuncer, M., Hansen, U. N., & Amis, A. A. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.04.006 · Cited by 49
“The Carter and Hayes [2] relationship is convenient, but this study concludes that this relationship, and also those by PerilloMarcone et al.”
BackgroundMethodInfluentialAndreaus, U., Colloca, M., & Iacoviello, D. (2013) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2013.09.002 · Cited by 43
Measurement of Bone: Diagnosis of SCI-Induced Osteoporosis and Fracture Risk Prediction
Troy, K. L., & Morse, L. R. (2015) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/sci2104-267 · Cited by 43
The mechanical properties of human ribs in young adult.
Pezowicz, C. A., & Głowacki, M. (2012) · PubMed · Cited by 43
Giesemann, M. A., Lewis, A. J., Miller, P. S., & Akhter, M. P. (1998) · Journal of Animal Science · doi:10.2527/1998.763796x · Cited by 43
Boehm, H. F., Raeth, C. W., Monetti, R., Müeller, D., Newitt, D. C., Majumdar, S., Rummeny, E. J., Morfill, G. E., & Link, T. M. (2003) · Investigative Radiology · doi:10.1097/01.rli.0000064782.94757.0f · Cited by 52
Homologous growth hormone accelerates healing of segmental bone defects
Raschke, M. J., Kolbeck, S., Bail, H. J., Schmidmaier, G., Flyvbjerg, A., Lindner, T., Dahne, M., Ahnfeld-Roenne, I., & Haas, N. P. (2001) · Bone · doi:10.1016/s8756-3282(01)00587-7 · Cited by 43
Clelland, N. L., Lee, J. K., Bimbenet, O. C., & Gilat, A. (1993) · Journal of Prosthodontics · doi:10.1111/j.1532-849x.1993.tb00405.x · Cited by 43
Effect of Femoral Stiffness on Bone Remodeling After Uncemented Arthroplasty
Sychterz, C. J., Topoleski, L. D. T., SACCO, M. E., & Engh, C. A. (2001) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200108000-00031 · Cited by 43
“the mediolateral direction, and (6) implant stiffness”
Les, C. M., STOVER, S. M., Keyak, J. H., Taylor, K., & Kaneps, A. J. (2002) · Journal of Orthopaedic Research® · doi:10.1016/s0736-0266(01)00138-3 · Cited by 50
An orientation distribution function for trabecular bone
Kinney, J. H., Stolken, J. S., Smith, T. S., Ryaby, J. T., & Lane, N. E. (2005) · Bone · doi:10.1016/j.bone.2004.09.023 · Cited by 47
Biomechanical characteristics of human trabecular bone
Ouyang, J., Yang, G., Wu, W., Zhu, Q., & Zhong, S. Z. (1997) · Clinical Biomechanics · doi:10.1016/s0268-0033(97)00035-1 · Cited by 51
The Effect of Trabecular Structure on DXA-based Predictions of Bovine Bone Failure
Oden, Z. M., Selvitelli, D. M., Hayes, W. C., & Myers, E. R. (1998) · Calcified Tissue International · doi:10.1007/s002239900491 · Cited by 47
“6 g/cm(3) for human proximal tibia [25, 26].”
Self-citationDemenko, V., Linetskiy, I., Nesvit, K., Hubálková, H., Nesvit, V., & Shevchenko, A. (2012) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2012.688110 · Cited by 46
Endocortical bone loss in osteoporosis: the role of bone surface availability
Buenzli, P. R., Thomas, C. D. L., Clement, J. G., & Pivonka, P. (2013) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2567 · Cited by 46
“The longitudinal stiffness of bone is not significantly different in compression and in tension [52, 54].”
BackgroundShu, J., Ma, H., Jia, L., Fang, H., Chong, D. Y. R., Zheng, T., Yao, J., & Liu, Z. (2020) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.3373 · Cited by 42
“3 according to the studies of Carter et al and Tanne et al.(31,32) The cartilages were modelled on surfaces of condyles and articular eminences with a thickness of 0.”
MethodInfluentialBone material properties and fracture analysis: Needle insertion for spinal surgery
Teoh, S. H., & Chui, C. K. (2007) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2007.06.004 · Cited by 48
A Functionalizable Biomaterial Based on Dihydroxyacetone, an Intermediate of Glucose Metabolism
Zelikin, A. N., Zawaneh, P. N., & Putnam, D. (2006) · Biomacromolecules · doi:10.1021/bm060544e · Cited by 43
Wong, A. S., New, A., Isaac, G. H., & Taylor, M. (2005) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/095441105x34293 · Cited by 53
The effect of impact on the marrow pressure of long bones in vitro
Bryant, J. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90117-3 · Cited by 42
NAMBU, T., Gasser, B., Schneider, E. H., Bandi, W., & Perren, S. M. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90030-q · Cited by 42
“Carter and Hayes (1977) reported strain to range from 3 to 20% for human cancellous bone.”
BackgroundJournal of Bone and Mineral Research
Carter, D. R. P., & Beaupré, G. S. (1990) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650051372 · Cited by 42
Self-citationJiang, Y., Zhao, J., Audekercke, R. V., Dequeker, J., & Geusens, P. (1996) · Calcified Tissue International · doi:10.1007/bf02509543 · Cited by 42
“A strong correlation between compressive strength and stiffness of vertebral trabecular bone and apparent density was reported [43].”
BackgroundBiomechanical properties and clinical significance of cancellous bone in proximal femur: A review
Wang, H., Zhang, Y., Ren, C., Ding, K., Zhang, Q., Zhu, Y., & Chen, W. (2023) · Injury · doi:10.1016/j.injury.2023.03.010 · Cited by 43
Choi, W. J., Cripton, P. A., & Robinovitch, S. N. (2014) · Osteoporosis International · doi:10.1007/s00198-014-2812-4 · Cited by 41
On the Road to Personalized Medicine: Multiscale Computational Modeling of Bone Tissue
Podshivalov, L., Fischer, A., & Bar‐Yoseph, P. (2014) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-014-9120-1 · Cited by 46
Bauer, J. S., Sidorenko, I. N., Müeller, D., Baum, T. H., Issever, A. S., Eckstein, F., Rummeny, E. J., Link, T. M., & Raeth, C. W. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2013.10.024 · Cited by 50
Sandino, C., McErlain, D. D., Schipilow, J. D., & Boyd, S. K. (2014) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2014.12.018 · Cited by 41
“Peroperative estimation of bone quality and primary dental implant stability”
Voumard, B., Maquer, G., Heuberger, P., Zysset, P. K., & Wolfram, U. (2018) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2018.12.035 · Cited by 43
“Bone apparent density is the primary variable determining bone quality (Seeman and Delmas, 2006) and the main determinant of bone strength (Carter and Hayes, 1977) and primary stability (Pommer et al., 2014).”
BackgroundRecent Advances in Development of Natural Cellulosic Non-Woven Scaffolds for Tissue Engineering
Aghazadeh, M. R., Delfanian, S., Aghakhani, P., Homaeigohar, S., Alipour, A., & Shahsavarani, H. (2022) · Polymers · doi:10.3390/polym14081531 · Cited by 42
Ateshian, G. A., Nims, R. J., Maas, S. A., & Weiss, J. A. (2014) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-014-0560-1 · Cited by 41
Kadir, M. R. A., Syahrom, A., & Öchsner, A. Ö. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0593-2 · Cited by 45
“These values are within the range of values for compression testing of cancellous bone specimens reported by other researchers [3, 5, 6, 51].”
BackgroundInfluentialTanne, K., Matsubara, S., & Sakuda, M. (1995) · British Journal of Orthodontics · doi:10.1179/bjo.22.3.227 · Cited by 41
Albert, C., Jameson, J., Smith, P. A., & Harris, G. E. (2014) · Bone · doi:10.1016/j.bone.2014.05.022 · Cited by 46
“Power law relationships were explored between each property and the bone volume fraction, as such relationships have been observed in normal bone tissue [57], [58], [59], [60], [61], [62].”
BackgroundSensitivity of femoral strain pattern analyses to resultant and muscle forces at the hip joint
Lengsfeld, M., Kaminsky, J., Merz, B., & Franke, R.-P. (1996) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)00033-x · Cited by 41
Topographical distribution of trabecular bone strength in the human os calcanei
Jensen, N. C., Madsen, L. P., & Linde, F. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90325-h · Cited by 43
Digital Radiography: A Predictor of Regenerate Bone Stiffness in Distraction Osteogenesis
Kolbeck, S., Bail, H. J., Weiler, A., Windhagen, H. J., Haas, N. P., & Raschke, M. J. (1999) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199909000-00029 · Cited by 41
Varga, P., Schwiedrzik, J. J., Zysset, P. K., Hofmann‐Fliri, L., Widmer, D., Gueorguiev, B. G., Blauth, M., & Windolf, M. (2015) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2015.11.026 · Cited by 41
The Bone Organ System: Form and Function
Morgan, E. F., Barnes, G. B., & Einhorn, T. A. (2010) · Elsevier eBooks · doi:10.1016/b978-0-12-375098-3.50004-4 · Cited by 44
Validation of a finite element model of the human metacarpal
Barker, D. S., Netherway, D. J., Krishnan, J., & Hearn, T. C. (2004) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2004.10.001 · Cited by 40
Lengsfeld, M., Burchard, R., Günther, D., Pressel, T., Schmitt, J., Leppek, R., & GRISS, P. (2005) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2004.12.016 · Cited by 40
Jiang, Y., Zhao, J., Geusens, P., Liao, E.-Y., Adriaensens, P., Gelan, J., Azria, M., Boonen, S., Caulin, F., Lynch, J. A., et al. (2005) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.041008 · Cited by 41
Biomechanical considerations on tooth-implant supported fixed partial dentures
Michalakis, K. X., Calvani, P., & Hirayama, H. (2012) · Journal of Dental Biomechanics · doi:10.1177/1758736012462025 · Cited by 40
Early tissue response to citric acid–based micro‐ and nanocomposites
Chung, E. J., Qiu, H., Kodali, P., Yang, S., Sprague, S. M., Hwong, J. S., Koh, J. L., & Ameer, G. A. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32953 · Cited by 43
“Although both microcomposite and nanocomposite elastic moduli were in range with those reported for human trabecular bone (1–1524 MPa), 60nano displayed a stiffness most similar to the mean modulus of human trabecular bone (211 6 78 MPa).(4,5) The strength of particulate-filled polymers is highly dependent on stress t…”
Moroni, A., Caja, V. L., Sábato, C., Egger, E. L., Gottsauner‐Wolf, F., & Chao, E. (1994) · Journal of Materials Science Materials in Medicine · doi:10.1007/bf00058975 · Cited by 40
Li, X., Mohan, S., Gu, W., Wergedal, J. E., & Baylink, D. J. (2001) · Calcified Tissue International · doi:10.1007/s00223-001-0004-7 · Cited by 40
“In the past, bone density has been widely treated as a reliable predictor for bone strength [12, 15, 16].”
BackgroundMiyasaka, J., Tanne, K., & Nakamura, S. (1994) · British Journal of Orthodontics · doi:10.1179/bjo.21.4.343 · Cited by 40
“Material constants of the tooth, and cortical and cancellous bones in the model were derived from previous data (Carter and Hayes, 1977; Cook et al., 1982; Orr and Carter, 1985), as shown in Table 1.”
MethodMechanical properties of bone from iliac crest and relationship to L5 vertebral bone
Britton, J. M., & Davie, M. W. J. (1990) · Bone · doi:10.1016/8756-3282(90)90067-9 · Cited by 40
Structure-function relationships for coralline hydroxyapatite bone substitute
Haddock, S. M., Debes, J. C., Nauman, E. A., Fong, K. E., Arramon, Y. P., & Keaveny, T. M. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199910)47:1<71::aid-jbm10>3.0.co;2-u · Cited by 40
Automated Finite Element Analysis of Excised Human Femora Based on Precision-QCT
Merz, B., Niederer, P. F., Müller, R., & Ruegsegger, P. (1996) · Journal of Biomechanical Engineering · doi:10.1115/1.2796021 · Cited by 40
Statistical Finite Element Model for Bone Shape and Biomechanical Properties
Querol, L. B., Büchler, P., Rueckert, D., Nolte, L. P., & Ballester, M. Á. G. (2006) · Lecture notes in computer science · doi:10.1007/11866565_50 · Cited by 39
Basalah, A., Esmaeili, S., & Toyserkani, E. (2016) · Journal of Materials Processing Technology · doi:10.1016/j.jmatprotec.2016.07.037 · Cited by 39
Vojtová, L., Michlovská, L., Valová, K., Zbončák, M., Trunec, M., Částková, K., Krtička, M., Pavliňáková, V., Poláček, P., Dzurov, M., et al. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20020391 · Cited by 39
“Sci. 2019, 20, 391 5 of 21 A comparison of Figure 2a,b reveals that after 1 min of mixing involving the placing of pastes in a rheometer set-up, the water/α-TCP cements, which commenced rheological measurement at a G′ of higher than 1 kPa and more than 1 MPa for an L/P equal to 0.35 g·g−1, were stiffer than the copoly…”
ResultInfluentialMechanoregulation modeling of bone healing in realistic fracture geometries
Ren, T., & Dailey, H. L. (2020) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-020-01340-5 · Cited by 44
Sarron, J.-C., Caillou, J.-P., Cunha, J. D., Allain, J.-C., & on, A. A. T. (2000) · doi:10.1097/00005373-200011000-00021 · Cited by 39
Harrigan, T. P., & Hamilton, J. J. (1994) · International Journal of Solids and Structures · doi:10.1016/0020-7683(94)90178-3 · Cited by 39
van Eijden, T. M. G. J., van Ruijven, L. J., & Giesen, E. B. W. (2004) · Calcified Tissue International · doi:10.1007/s00223-004-0295-6 · Cited by 47
“3 [10, 23].”
Vyas, U., Ghanouni, P., Halpern, C. H., Elias, J., & Butts, K. (2016) · Medical Physics · doi:10.1118/1.4955436 · Cited by 40
Metadata
- Authors
- Carter, D., & Hayes, W.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1977-10
- Volume
- 59
- Issue
- 7
- Pages
- 954-962
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W1901463649
- Semantic Scholar
- cc21d6cd590fb46c2bd9cfd768da63c8012862ee
- Cited by
- 2,001
- References
- 0
- Citations by year
- 2026: 30 · 2025: 31 · 2024: 41 · 2023: 40 · 2022: 60 · 2021: 61 · 2020: 57 · 2019: 66 · 2018: 59 · 2017: 55 · 2016: 55 · 2015: 67 · 2014: 79 · 2013: 68 · 2012: 67
- FWCI
- 18.23
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Bone and Joint Surgery (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Physical Sciences › Engineering › Mechanical Engineering › Cellular and Composite Structures
- Keywords
- trabecular bone, strain rate sensitivity, bone stiffness, energy absorption, marrow, porous structure, apparent density, human bone, bovine bone
- MeSH terms
- Animals, Bone and Bones, Cattle, Humans, Stress, Mechanical, Tensile Strength
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.