The compressive behavior of bone as a two-phase porous structure
The DOI matches its Crossref record.
Abstract
Compression tests of human and bovine trabecular bone specimens with and without marrow in situ were conducted at strain rates of from 0.001 to 10.0 per second. A porous platen above the specimens allowed the escape of marrow during testing. The presence of marrow increased the strength, modulus, and energy absorption of specimens only at the highest strain rate of 10.0 per second. This enhancement of material properties at the highest strain rate was due primarily to the restricted viscous flow of marrow through the platen rather than the flow through the pores of the trabecular bone. In specimens without marrow, the strength was proportional to the square of the apparent density and the modulus was proportional to the cube of the apparent density. Both strength and modulus were approximately proportional to the strain rate raised to the 0.06 power. These power relationships, which were shown to hold for all bone in the skeleton, allow meaningful predictions of bone tissue strength and stiffness based on in vivo density measurements.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The compressive modulus and compressive strength are proportional to the strain rate raised to the power of 0.06 (100, 101).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [101]
Citations
Cited by
Items 301–400 of 1,002
Chao, E. Y. S., Inoue, N., Koo, T. K. K., & Kim, Y. H. (2004) · Clinical Orthopaedics and Related Research · doi:10.1097/01.blo.0000132263.14046.0c · Cited by 102
“A linear relationship between bone density versus the strength and elastic modulus has been reported for the cortical bone, but a nonlinear dependence of strength and elastic modulus of the cancellous bone on the bone density was shown.32 This nonlinearity has been well described as a power-law by Carter and Hayes.15…”
BackgroundMaterial Properties of the Mandibular Trabecular Bone
Lakatos, É. I., Magyar, L., & Bojtár, I. (2014) · Journal of Medical Engineering · doi:10.1155/2014/470539 · Cited by 101
“The removal of themedullary substance slightly affects Young’s modulus, when low strain rates are used, while in case of sudden impact liquids in the medullary cavities result in the increase of stiffness [6].”
BackgroundInfluentialCompressive mechanical properties of demineralized and deproteinized cancellous bone
Chen, P.-Y., & McKittrick, J. M. (2011) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2011.02.006 · Cited by 103
“Experimental studies on cancellous bone have addressed mechanical properties as a function of apparent density (Carter and Hayes, 1976, 1977; Rice et al., 1988; Hodgskinson and Currey, 1992), anatomic location (Goldstein, 1987), loading direction 1751-6161/$ - see front matter c⃝ 2011 Elsevier Ltd.”
BackgroundAustman, R. L., Milner, J. S., Holdsworth, D. W., & Dunning, C. E. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.08.017 · Cited by 101
“Of the eight specimens, three were matched most closely to the experimental values by using the Carter and Hayes (1977) equation (which tended to overestimate) and five were matched most closely using the Morgan et al. (2003) equation (which tended to under-estimate).”
BackgroundMethodResultInfluentialDistribution of bone strength in the proximal tibia
Harada, Y., Wevers, H. W., & Cooke, T. D. V. (1988) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(88)80082-2 · Cited by 101
Kang, M., Lee, H., Jang, T., Seong, Y., Kim, H., Koh, Y., Song, J., & Jung, H. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.11.045 · Cited by 100
Rubin, P., Rakotomanana, L. R., Leyvraz, P. F., Zysset, P. K., Curnier, A., & Heegaard, J. H. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90035-d · Cited by 106
Mechanical Effects of Stem Cement Interface Characteristics in Total Hip Replacement
Verdonschot, N. J. J., & Huiskes, R. (1996) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199608000-00040 · Cited by 100
MacLatchy, L., & Müller, R. (2002) · Journal of Human Evolution · doi:10.1006/jhev.2002.0559 · Cited by 109
The Bone Extracellular Matrix as an Ideal Milieu for Cancer Cell Metastases
Kolb, A. D., & Bussard, K. M. (2019) · Cancers · doi:10.3390/cancers11071020 · Cited by 106
“Differences between cortical and trabecular bone are determined by density and porosity [14,15].”
BackgroundMeyer, U., Vollmer, D., Runte, C., Bourauel, C. P., & Joos, U. (2001) · Journal of Cranio-Maxillofacial Surgery · doi:10.1054/jcms.2001.0198 · Cited by 98
Schumacher, M., Deisinger, U., Detsch, R., & Ziegler, G. (2010) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-010-4166-6 · Cited by 97
“Specimens in all test series attained a compressive strength within and above the range of human cancellous bone (0.6–15 MPa [4, 48 ]).”
BackgroundInfluentialNjeh, C. F., Hodgskinson, R., Currey, J. D., & Langton, C. M. (1996) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)00064-x · Cited by 106
Boyle, C., & Kim, I. Y. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.03.038 · Cited by 103
Shim, V. P. W., Yang, L., Liu, J. F., & Lee, V. S. (2005) · International Journal of Impact Engineering · doi:10.1016/j.ijimpeng.2005.03.006 · Cited by 107
Femoral Neck Trabecular Bone: Loss With Aging and Role in Preventing Fracture
Thomas, C. D. L., Mayhew, P. M., Power, J., Poole, K. E. S., Loveridge, N., Clement, J. G., Burgoyne, C. J., & REEVE, J. (2009) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.090504 · Cited by 109
“creased by treatments such as PTH(1-34) and PTH(1-84), which increase trabecular bone; however, if cortical crushing is the chief initiator of the fracture process, it might be necessary for anabolic treatments to thicken the cortex, if”
BackgroundCement Debonding Process of Total Hip Arthroplasty Stems
Verdonschot, N. J. J., & Huiskes, R. (1997) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199703000-00038 · Cited by 96
X-ray fluorescence: Issues surrounding the application of a new tool for measuring burden of lead
Hu, H., Milder, F. L., & Burger, D. E. (1989) · Environmental Research · doi:10.1016/s0013-9351(89)80074-x · Cited by 95
Effect of bone to implant contact percentage on bone remodelling surrounding a dental implant
Lian, Z., Guan, H., Ivanovski, S., Loo, Y., Johnson, N. W., & Zhang, H. (2010) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.ijom.2010.03.020 · Cited by 94
“…have been established experimentally[12] [13] [14] . a specific relationship between the elastic modulus and density as suggested by Carter and Hayes[12], i.e: 3 3790 ) , ( ρ × = t x E (10) where ρ is the apparent density of bone tissue; C and γ are the constants which can be determined through…”
InfluentialOta, T., Yamamoto, I., & Morita, R. (1999) · Journal of Bone and Mineral Metabolism · doi:10.1007/s007740050072 · Cited by 94
Esses, S. I., Lotz, J. C., & Hayes, W. C. (1989) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650040510 · Cited by 94
Self-citationCompressive properties of cortical bone: mineral-organic interfacial bonding
Walsh, W. R., & Güzelsu, N. (1994) · Biomaterials · doi:10.1016/0142-9612(94)90263-1 · Cited by 93
Grosland, N. M., Shivanna, K. H., Magnotta, V. A., Kallemeyn, N. A., DeVries, N. A., Tadepalli, S. C., & Lisle, C. R. (2009) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2008.12.003 · Cited by 93
Milentijevic, D., & Torzilli, P. A. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.04.016 · Cited by 102
Micromechanics modeling of Haversian cortical bone properties
Hogan, H. A. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90095-i · Cited by 93
The limitations of canine trabecular bone as a model for human: A biomechanical study
Kuhn, J. L., Goldstein, S. A., Ciarelli, M. J., & Matthews, L. S. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90032-8 · Cited by 104
“This analysis followed the lead of others who have used bone density as a first approach to explaining the variance in trabecular bone modulus and strength (Behrens and Walker, 1974; Carter and Hayes, 1977; Ciarelli et al., 1986; Ducheynne et al., 1977; Galante et al., 1970; Keller et al., 1986).”
BackgroundMethodResultInfluentialA review of the biomechanical properties of bone as a material
NATALI, A. N., & Meroi, E. A. (1989) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(89)90058-7 · Cited by 113
Validation of subject-specific automated p-FE analysis of the proximal femur
Trabelsi, N., Yosibash, Z., & Milgrom, C. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.10.039 · Cited by 92
Hong, J., Cabe, G. D., Tedrow, J. R., Hipp, J. A., & Snyder, B. D. (2004) · Journal of Orthopaedic Research · doi:10.1016/j.orthres.2003.09.006 · Cited by 91
Articular structure and function in Hylobates, Colobus, and Papio
Rafferty, K. L., & Ruff, C. B. (1994) · American Journal of Physical Anthropology · doi:10.1002/ajpa.1330940308 · Cited by 92
Mass– and volume–specific views on thermodynamics for open systems
Ellen Kuhl, A., & Steinmann, P. (2003) · Proceedings of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rspa.2003.1119 · Cited by 92
“…the simplest choice for the free-energy function ª for cellular materials such as open-pored biological tissues is based on the classical isotropic NeoHookean-type free-energy function weighted by the actual relative density [ » 0=» ¤0] n (see, for example, Carter & Hayes 1977; Gibson & Ashby…”
MethodA new approach for assigning bone material properties from CT images into finite element models
Chen, G., Schmutz, B., Epari, D. R., Rathnayaka, K., Ibrahim, S. K., Schuetz, M., & Pearcy, M. J. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.10.040 · Cited by 92
“Step 2: the Young’s modulus (E) is related to the bone density (r) by E=Cr, where C and r are constants and r is either the ash density or apparent density (Carter and Hayes, 1977; Kopperdahl et al., 2002; Morgan et al., 2003; Wirtz et al., 2000). Following Keller (1994), this paper used E=10500r, where r is the ash d…”
BackgroundMethodBiomechanical analysis of arm fracture in obese boys
Davidson, P., Goulding, A., & Chalmers, D. J. (2003) · Journal of Paediatrics and Child Health · doi:10.1046/j.1440-1754.2003.00243.x · Cited by 92
Ligamentotaxis and bone grafting for comminuted fractures of the distal radius
Leung, K. S., Shen, W., Leung, P., Kinninmonth, A. W. G., Chang, J., & Chan, G. (1989) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.71b5.2584256 · Cited by 92
Verma, R., Kumar, J., Singh, N. K., Kumar, S., Saxena, K. K., & Xu, J. (2022) · Coatings · doi:10.3390/coatings12060839 · Cited by 91
“Porosity can be varied by altering the thickness of the surface or struts, such that they are suitable for trabecular or cortical bone replacement (50%–90% porosity) [57,58].”
Jonkers, I., Sauwen, N., Lenaerts, G., Mulier, M., der Perre, G. V., & Jaecques, S. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.09.011 · Cited by 91
“Several authors suggest that quantitative validation and prediction of some subject-specific phenomena can only be achieved through a more personalized approach (Bitsakos et al., 2005; Carter and Hayes, 1977; Gruen et al., 1979; Huiskes et al., 1992; Kerner et al., 1999).”
InfluentialIwasaki, Y., Kazama, J. J., Yamato, H., & Fukagawa, M. (2011) · Bone · doi:10.1016/j.bone.2011.03.672 · Cited by 101
“Cortical bone is a viscoelastic material [29–31].”
BackgroundBone mineralization density and femoral neck fragility
Loveridge, N., Power, J., REEVE, J., & BOYDE, A. (2004) · Bone · doi:10.1016/j.bone.2004.05.025 · Cited by 95
Fundamental Biomechanics in Bone Tissue Engineering
Wang, X., Nyman, J. S., Dong, X., Leng, H., & Reyes, M. (2010) · Synthesis lectures on tissue engineering · doi:10.1007/978-3-031-02579-2 · Cited by 121
Material properties of femoral cancellous bone in axial loading: Part II: Time dependent properties
Zilch, H., Rohlmann, A., Bergmann, G., & K�lbel, R. (1980) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/bf00380706 · Cited by 91
Computer predictions of bone remodeling around porous-coated implants
Orr, T. E., Beaupré, G. S., Carter, D. R. P., & Schurman, D. J. (1990) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(08)80074-5 · Cited by 91
Self-citationJørgensen, P. H., Bak, B., & Andreassen, T. T. (1991) · Bone · doi:10.1016/8756-3282(91)90022-b · Cited by 91
Phillips, A., Villette, C. C., & Modenese, L. (2015) · International Biomechanics · doi:10.1080/23335432.2015.1017609 · Cited by 95
“At the macroscale bone is considered as a continuum without voids, with material properties assigned across elements based on empirical relationships between CT attenuation values, density and Young’s modulus (Carter & Hayes 1977; Helgason et al. 2008).”
BackgroundVastel, L., Meunier, A., Siney, H., Sedel, L., & Courpied, J.-P. (2003) · Biomaterials · doi:10.1016/j.biomaterials.2003.08.067 · Cited by 97
The mechanical and stress adaptive properties of bone
Cowin, S. C. (1983) · Annals of Biomedical Engineering · doi:10.1007/bf02363288 · Cited by 106
Skedros, J. G., Su, S. C., & Bloebaum, R. D. (1997) · The Anatomical Record · doi:10.1002/(sici)1097-0185(199711)249:3<297::aid-ar1>3.0.co;2-s · Cited by 101
“Porosity has also been shown to be inversely correlated with compressive strength (Carter and Hayes, 1977a) and elastic modulus in specimens of cortical bone (Carter and Hayes, 1977a; Currey, 1988; Schaffler and Burr, 1988).”
Human Models for Crash and Impact Simulation
Haug, E., Choi, H.-Y., Robin, S., & Beaugonin, M. (2004) · Handbook of numerical analysis · doi:10.1016/s1570-8659(03)12004-2 · Cited by 109
Behrens, B., Nolte, I. J. A., Wefstaedt, P., Stukenborg-Colsman, C. M., & Bouguecha, A. (2009) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-8-7 · Cited by 89
“To couple the Young's modulus of the bone with the ABD, the relationship between these two terms is described as a power function according to Eq. 2 on the basis of the experimental study of Carter et al. [ 22 ].”
MethodBone ingrowth simulation for a concept glenoid component design
Andreykiv, A., Prendergast, P. J., van Keulen, F., Święszkowski, W., & Rozing, P. M. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.05.044 · Cited by 89
Prediction of cortical bone porosityIn Vitro by microcomputed tomography
Wachter, N. J., Augat, P., Krischak, G. D., Mentzel, M., Kinzl, L., & Claes, L. (2001) · Calcified Tissue International · doi:10.1007/bf02685001 · Cited by 94
Hengsberger, S., Enstroem, J., Peyrin, F., & Zysset, P. K. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00131-3 · Cited by 101
Mechanical Properties of Trabecular Bone by a Non-Destructive Compression Testing Approach
Linde, F., Gøosthgen, C. B., Hvid, I., Pongsoipetch, B., & Bentzen, S. (1988) · Engineering in Medicine · doi:10.1243/emed_jour_1988_017_008_02 · Cited by 100
Stiffness behaviour of trabecular bone specimens
Linde, F., & Hvid, I. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90270-3 · Cited by 89
Technical note. Characterization of a synthetic foam as a model for human cancellous bone
Szivek, J. A., Thomas, M., & Benjamin, J. B. (1993) · Journal of Applied Biomaterials · doi:10.1002/jab.770040309 · Cited by 89
Compressive creep behavior of bovine trabecular bone
Bowman, S. M., Keaveny, T. M., Gibson, L. J., Hayes, W. C., & McMahon, T. A. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90006-x · Cited by 88
Self-citationFinite element prediction of surface strain and fracture strength at the distal radius
Edwards, W. B., & Troy, K. L. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.07.016 · Cited by 88
“Presumably, this 353 would require us to incorporate strain-rate dependent behavior into our models, which could be 354 done for Young’s modulus by including a second power-term in the density-elasticity 355 relationship [18].”
BackgroundMethodHakulinen, M. A., Day, J. S., Töyräs, J., Timonen, M., Kröger, H., Weinans, H., Kiviranta, I., & Jurvelin, J. S. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/8/001 · Cited by 88
Effects of Structural Variation on Young's Modulus of Non-Human Cancellous Bone
Hodgskinson, R., & Currey, J. D. (1990) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/pime_proc_1990_204_227_02 · Cited by 88
Theoretical and Empirical Scaling Patterns and Topological Homology in Bone Trabeculae
Swartz, S. M., Parker, A., & Huo, C. (1998) · Journal of Experimental Biology · doi:10.1242/jeb.201.4.573 · Cited by 100
Mechanical and morphometric analysis of the third carpal bone of Thoroughbreds
Young, D. R., Richardson, D. W., Markel, M. D., & Nunamaker, D. M. (1991) · American Journal of Veterinary Research · doi:10.2460/ajvr.1991.52.03.402 · Cited by 87
Axisymmetric finite element analysis of the lateral tibial plateau
Hayes, W. C., Swenson, L. W., & Schurman, D. J. (1978) · Journal of Biomechanics · doi:10.1016/0021-9290(78)90040-4 · Cited by 86
Self-citationCompressive axial strain distributions in cancellous bone specimens
Odgaard, A., Hvid, I., & Linde, F. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90066-3 · Cited by 86
Courtney, A., & Courtney, M. (2015) · Frontiers in Neurology · doi:10.3389/fneur.2015.00221 · Cited by 84
“The results suggested that “the presence of marrow during severe, traumatic, compressive loading in vivo may serve to absorb considerable energy” (78).”
BackgroundViscoelastic properties of human cortical bone tissue depend on gender and elastic modulus
Wu, Z., Ovaert, T. C., & Niebur, G. L. (2012) · Journal of Orthopaedic Research · doi:10.1002/jor.22001 · Cited by 81
Fung, Y. C. (1993) · Springer eBooks · doi:10.1007/978-1-4757-2257-4_12 · Cited by 91
Mechanisms of osteoporosis therapy: A bone strength perspective
Bouxsein, M. (2003) · Clinical cornerstone · doi:10.1016/s1098-3597(03)90043-3 · Cited by 89
Tolerance of the human leg and thigh in dynamic latero-medial bending
Kerrigan, J. R., Drinkwater, D. C., Kam, C. Y., Murphy, D. B., Ivarsson, B. J., Crandall, J., & Patrie, J. T. (2004) · International Journal of Crashworthiness · doi:10.1533/ijcr.2004.0315 · Cited by 84
Finite element analysis of the human mandible at 3 different stages of life
Bujtár, P., Sándor, G. K. B., Bojtos, A., Szűcs, A. L., & Barabás, J. (2010) · Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology · doi:10.1016/j.tripleo.2010.01.025 · Cited by 84
Experimental method for the measurement of the elastic modulus of trabecular bone tissue
Mente, P. L., & Lewis, J. L. (1989) · Journal of Orthopaedic Research · doi:10.1002/jor.1100070320 · Cited by 79
“Many researchers have assumed that these two tissues are basically the same, the degree of porosity being their only distinguishing characteristic (1,2,5,6).”
Perillo‐Marcone, A., & Taylor, M. (2006) · Journal of Biomechanical Engineering · doi:10.1115/1.2401177 · Cited by 87
Leterrier, C., & Nys, Y. Y. (1992) · British Poultry Science · doi:10.1080/00071669208417536 · Cited by 83
Yu, H., Baik, H. S., Sung, S. J., Kim, K., & Cho, Y. S. (2007) · European Journal of Orthodontics · doi:10.1093/ejo/cjl057 · Cited by 83
“The craniofacial bones were assumed to be composed of spongious and compact bones, and for the properties of each material, Young’s modulus ( E ) and Poisson’s V ratio (Table 1 ) were used as in previous studies ( Carter and Hayes, 1977 ; Cook et al. , 1982 ; Orr and Carter, 1985 ).”
MethodAndreaus, U., Giorgio, I., & Madeo, A. (2014) · Zeitschrift für angewandte Mathematik und Physik · doi:10.1007/s00033-014-0403-z · Cited by 82
Wehner, T., Claes, L., Niemeyer, F., Nolte, D., & Simon, U. (2010) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2010.03.003 · Cited by 82
“This was done by a non-linear rule of mixture for the Young's modulus, which represented an extended version of the two-phase structure description of (Carter and Hayes, 1977) to three phases using the following equation.”
MethodVarghese, B. A., Short, D., Penmetsa, R. C., Goswami, T., & Hangartner, T. N. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.12.028 · Cited by 82
“One specific study of the distal ulna (Austman et al., 2008) revealed that bones with lower densities produced low errors when using the Morgan equation (Morgan et al., 2003) and bones with higher densities produced low errors when using the Carter-and-Hayes equation (Carter and Hayes, 1977).”
MethodNovitskaya, E. E., Chen, P., Hamed, E., Jun, L., Lubarda, V. A., Jasiuk, I., & McKittrick, J. M. (2011) · Theoretical and Applied Mechanics · doi:10.2298/tam1103209n · Cited by 93
The effect of holding time on nanoindentation measurements of creep in bone
Wu, Z., Baker, T. A., Ovaert, T. C., & Niebur, G. L. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.01.039 · Cited by 82
“The viscoelasticity of bone has been studied at the macroscopic level with conventional mechanical testing methods, such as compression and torsion testing (Carter and Hayes, 1976, Carter and Hayes, 1977, Lakes, et al., 1979, Sasaki and Enyo, 1995).”
Pullout Strengths of Cannulated and Noncannulated Cancellous Bone Screws
THOMPSON, J. D., Benjamin, J. B., & Szivek, J. A. (1997) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199708000-00035 · Cited by 82
Effect of Hormone Replacement Therapy on Bone Quality in Early Postmenopausal Women
Paschalis, E. P., Boskey, A. L., Kassem, M. S., & Eriksen, E. F. (2003) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2003.18.6.955 · Cited by 90
Empirical relationships between bone density and ultimate strength: A literature review
Fleps, I., Bahaloo, H., Zysset, P. K., Ferguson, S. J., Pálsson, H., & Helgason, B. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.103866 · Cited by 85
“If isotropy is assumed (mi 1⁄4 1), the empirical relationship reported by Charlebois et al. (2010) would predict a compressive strength for cortical bone of 48.1 MPa at a density of 1.8 g/cm3, which is a lower compressive ultimate strength for dense cortical bone than studies measuring cortical bone are reporting. In…”
BackgroundResultInfluentialAnalysis of mechanical properties of cancellous bone under conditions of simulated bone atrophy
Müller, R., & Ruegsegger, P. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(96)00006-1 · Cited by 92
Elastic moduli, yield stress, and ultimate stress of cancellous bone in the canine proximal femur
Vahey, J. W., Lewis, J. L., & Vanderby, R. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90264-8 · Cited by 81
Femoral head apparent density distribution predicted from bone stresses
Fyhrie, D. P., & Carter, D. R. P. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90363-8 · Cited by 81
Self-citationHow can bone turnover modify bone strength independent of bone mass?
Hernandez, C. J. (2008) · Bone · doi:10.1016/j.bone.2008.02.001 · Cited by 93
“where E is the stiffness of the specimen (elastic modulus), σUlt is the strength (ultimate stress) in compression, and A and B are constants [14] (for a comprehensive review please see [15,16]).”
BackgroundMechanical testing of bones: the positive synergy of finite–element models and in vitro experiments
Cristofolini, L., Schileo, E., Juszczyk, M., Taddei, F., Martelli, S., & Viceconti, M. (2010) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2010.0046 · Cited by 80
“…of deriving bone tissue density from CT scan data (Kalender 1992) and using the acknowledged relationship that exists between the density and elasticity of bone tissue, when tested under the hypothesis of continuum mechanics (Carter & Hayes 1977; Keller 1994; Wirtz et al. 2000; Morgan et al. 2003).”
Characterizations of additive manufactured porous titanium implants
Basalah, A., Shanjani, Y., Esmaeili, S., & Toyserkani, E. (2012) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.32764 · Cited by 80
Structural analysis of the frontal and parietal bones of the human skull
Alexander, S. L., Rafaels, K. A., Gunnarsson, C. A., & Weerasooriya, T. (2018) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2018.10.035 · Cited by 80
Trevisan, C. L., Bigoni, M., Cherubini, R., Steiger, P., Randelli, G., & Ortolani, S. (1993) · Calcified Tissue International · doi:10.1007/bf01321831 · Cited by 80
“The possibility of an accurate and precise evaluation of proximal femur BMD before and following THA insertion could give the surgeon information about fundamental elements influencing stability, osseo-integration, and eventually, durability of implants [19-23] as: patient bone stock and bone strength (which is strict…”
Three-dimensional finite element modelling of bone: effects of element size
Keyak, J. H., & Skinner, H. B. (1992) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(92)90100-y · Cited by 80
Vu, A. A., Burke, D. A., Bandyopadhyay, A. K., & Bose, S. (2021) · Additive manufacturing · doi:10.1016/j.addma.2021.101870 · Cited by 86
Chen, J., Ahmad, R., Suenaga, H., Li, W., Sasaki, K., Swain, M. V., & Li, Q. (2015) · PLoS ONE · doi:10.1371/journal.pone.0132552 · Cited by 79
Ability of ultrasound backscattering to predict mechanical properties of bovine trabecular bone
Hakulinen, M. A., Töyräs, J., Saarakkala, S. S., Hirvonen, J., Kröger, H., & Jurvelin, J. S. (2004) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2004.04.006 · Cited by 79
Liu, X., Ma, J., Park, P., Huang, X., Xie, N., & Ye, X. (2017) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-017-1387-6 · Cited by 79
“The “osteoporotic spine” was modeled by simulating the loss of elastic modulus of normal bone, and 33 and 66% of the elastic modulus was reduced for the cortical and cancellous bone, respectively [32].”
MethodChong, D. Y. R., Hansen, U. N., van der Venne, R., Verdonschot, N. J. J., & Amis, A. A. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.11.026 · Cited by 78
“determined by analysing the zonal area of the prosthesis with interface micromotion lower than50 mm,where osseointegration is likely (Chong et al., 2010). Osseointegration waspredicted tooccur on33%of the surface areaof the tray and stem, in linewith Turner et al. (1989)andSumneretal.”
MethodSkedros, J. G., Dayton, M. R., Sybrowsky, C. L., Bloebaum, R. D., & Bachus, K. N. (2006) · Journal of Experimental Biology · doi:10.1242/jeb.02304 · Cited by 88
“…that the mechanical properties of bone material are generally superior in compression and tension when compared to shear (Boyce et al., 1998; Burstein et al., 1976; Carter and Hayes, 1977; Jepsen et al., 2001; Norman et al., 1996; Pattin et al., 1996; Reilly and Currey, 2000; Turner et al., 2001).”
BackgroundMethodInfluentialInzana, J. A., Varga, P., & Windolf, M. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.04.021 · Cited by 78
Cook, S. D., WEINSTEIN, A. M., & Klawitter, J. J. (1982) · Journal of Dental Research · doi:10.1177/00220345820610010501 · Cited by 78
Sievänen, H. T., Heinonen, A. O., & Kannus, P. (1996) · Bone · doi:10.1016/8756-3282(96)00111-1 · Cited by 78
Siffert, R. S., Luo, G., Cowin, S. C., & Kaufman, J. J. (1996) · Bone · doi:10.1016/8756-3282(95)00446-7 · Cited by 85
Ouldyerou, A., Mehboob, H., Merdji, A., Aminallah, L., Mehboob, A., & Mukdadi, O. M. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.106111 · Cited by 77
Metadata
- Authors
- Carter, D., & Hayes, W.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1977-10
- Volume
- 59
- Issue
- 7
- Pages
- 954-962
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W1901463649
- Semantic Scholar
- cc21d6cd590fb46c2bd9cfd768da63c8012862ee
- Cited by
- 2,001
- References
- 0
- Citations by year
- 2026: 30 · 2025: 31 · 2024: 41 · 2023: 40 · 2022: 60 · 2021: 61 · 2020: 57 · 2019: 66 · 2018: 59 · 2017: 55 · 2016: 55 · 2015: 67 · 2014: 79 · 2013: 68 · 2012: 67
- FWCI
- 18.23
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Bone and Joint Surgery (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Physical Sciences › Engineering › Mechanical Engineering › Cellular and Composite Structures
- Keywords
- trabecular bone, strain rate sensitivity, bone stiffness, energy absorption, marrow, porous structure, apparent density, human bone, bovine bone
- MeSH terms
- Animals, Bone and Bones, Cattle, Humans, Stress, Mechanical, Tensile Strength
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.