The compressive behavior of bone as a two-phase porous structure
The DOI matches its Crossref record.
Abstract
Compression tests of human and bovine trabecular bone specimens with and without marrow in situ were conducted at strain rates of from 0.001 to 10.0 per second. A porous platen above the specimens allowed the escape of marrow during testing. The presence of marrow increased the strength, modulus, and energy absorption of specimens only at the highest strain rate of 10.0 per second. This enhancement of material properties at the highest strain rate was due primarily to the restricted viscous flow of marrow through the platen rather than the flow through the pores of the trabecular bone. In specimens without marrow, the strength was proportional to the square of the apparent density and the modulus was proportional to the cube of the apparent density. Both strength and modulus were approximately proportional to the strain rate raised to the 0.06 power. These power relationships, which were shown to hold for all bone in the skeleton, allow meaningful predictions of bone tissue strength and stiffness based on in vivo density measurements.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The compressive modulus and compressive strength are proportional to the strain rate raised to the power of 0.06 (100, 101).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [101]
Citations
Cited by
Items 701–800 of 1,002
Cattaneo, P. M., Kofod, T., Dalstra, M., & Melsen, B. (2005) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840500237953 · Cited by 43
“…(tables 2 and 3) (Hart et al. 1992, Tanaka and Tanne 1994, Dechow and Carlson 1990, Dechow et al. 1993, Arendts 1989, Andersen et al. 1991, Nishihara and Nakamura 1994, Meijer et al. 1993, Giesen et al. 2001, Misch et al. 1999, Turner et al. 1999, Carter and Hayes 1977, Ashman and Rho 1988).”
BackgroundOptimal-tuning PID control of adaptive materials for structural efficiency
Andreaus, U., Colloca, M., Iacoviello, D., & Pignataro, M. (2010) · Structural and Multidisciplinary Optimization · doi:10.1007/s00158-010-0531-9 · Cited by 38
“The relation between Young’s modulus E and the apparent density ρ was taken as given by (9a) with γ = 3( Carter and Hayes 1977 )a ndC = 3.227 (GPa)(Kg·m −3 ) −3 as in”
MethodInfluentialCorticotomy affects both the modus and magnitude of orthodontic tooth movement
Verna, C., Cattaneo, P. M., & Dalstra, M. (2017) · European Journal of Orthodontics · doi:10.1093/ejo/cjx041 · Cited by 38
Biomechanics of immature human cortical bone: A systematic review
Szabo, E., & Rimnac, C. M. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.104889 · Cited by 39
Mechanical properties and bone densities of canine trabecular bone
Kang, Q., An, Y. H., & FRIEDMAN, R. F. (1998) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1008852610820 · Cited by 38
Zhang, H., & Bai, J. (2007) · Spine · doi:10.1097/01.brs.0000261036.04919.91 · Cited by 40
“This was achieved by converting the CT number first to a density value and then into the corresponding Young’s modulus.(23,24) The marrow, determined directly by the segmented Visible Human Project data set, was defined as an incompressible material.”
MethodSyahrom, A., Kadir, M. R. A., Abdullah, J. B., & Öchsner, A. Ö. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0833-0 · Cited by 38
“Also the marrow will effect to increasing modulus, strength, and energy absorption of the specimen [41].”
BackgroundDensity and architecture have greater effects on the toughness of trabecular bone than damage
Garrison, J. G., Slaboch, C. L., & Niebur, G. L. (2009) · Bone · doi:10.1016/j.bone.2008.12.030 · Cited by 40
“removed to facilitate gluing, but this should not affect the mechanical properties at the strain rates studied [26].”
BackgroundTerrier, A., Merlini, F., Pioletti, D. P., & Farron, A. (2009) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2008.11.008 · Cited by 38
Cementless Implant Composition and Femoral Stress: A Finite Element Analysis
Namba, R. S., Keyak, J. H., Kim, A. S., Vu, L. P., & Skinner, H. B. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199802000-00032 · Cited by 38
Whyne, C. M., Hu, S. S., Klisch, S. M., & Lotz, J. C. (1998) · Spine · doi:10.1097/00007632-199804150-00011 · Cited by 44
Optimality conditions for finite element simulation of adaptive bone remodeling
Harrigan, T. P., & Hamilton, J. J. (1992) · International Journal of Solids and Structures · doi:10.1016/0020-7683(92)90147-l · Cited by 38
Postfailure compressive behavior of tibial trabecular bone in three anatomic directions
Keyak, J. H., Lee, I. Y., Nath, D. S., & Skinner, H. B. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199607)31:3<373::aid-jbm11>3.0.co;2-k · Cited by 38
Modelling of orbital deformation using finite-element analysis
Al‐Sukhun, J., Lindqvist, C., & Kontio, R. K. (2005) · Journal of The Royal Society Interface · doi:10.1098/rsif.2005.0084 · Cited by 38
Structural strength of the macaque femur
Burr, D. B., Piotrowski, G., & Miller, G. J. (1981) · American Journal of Physical Anthropology · doi:10.1002/ajpa.1330540303 · Cited by 38
Effect of Salmon Calcitonin on Femoral Bone Quality in Adult Ovariectomized Ewes
Geusens, P., Boonen, S., Nijs, J., Jiang, Y., Lowet, G., Auderkercke, R. V., Huyghe, C., Caulin, F., Very, J. M., Dequeker, J., et al. (1996) · Calcified Tissue International · doi:10.1007/s002239900132 · Cited by 38
“Strength and stiffness of bone tissue are directly proportional to its mineral density [18] as evidenced by the significant correlation between the ultimate strength of the femoral neck cylinder and DEQCT in this study as well.”
BackgroundFalcinelli, C., Martino, A. C. D., Gizzi, A., Vairo, G., & Denaro, V. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.01.014 · Cited by 37
Zhai, X., Nauman, E. A., Moryl, D. L., Lycke, R., & Chen, W. W. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.103597 · Cited by 39
Feng, Y., Shu, J., Liu, Y., Zheng, T., Shao, B., & Liu, Z. (2021) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2021.106299 · Cited by 37
Integrated remodeling-to-fracture finite element model of human proximal femur behavior
Hambli, R., Lespessailles, É., & Benhamou, C.-L. (2012) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2012.08.011 · Cited by 39
Fitzpatrick, C. K., Hemelaar, P., & Taylor, M. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.02.018 · Cited by 37
Kasra, M., & Grynpas, M. D. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.03.008 · Cited by 42
Design of Human Surrogates for the Study of Biomechanical Injury: A Review
Payne, T., Mitchell, S. R., & Bibb, R. (2013) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.2013006847 · Cited by 40
Lee, W., & Jasiuk, I. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.02.022 · Cited by 37
“The measured weight and the volume obtained from the micro-CT images were used for calculating the density and apparent density (Carter and Hayes, 1977; Galante et al., 1970; Zioupos et al., 2008).”
MethodWang, Y.-F., Barrera, C. M., Dauer, E. A., Gu, W., Andreopoulos, F. M., & Huang, C. ‐. C. (2016) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2016.09.029 · Cited by 37
Kofod, T., Cattaneo, P. M., Dalstra, M., & Melsen, B. (2005) · Journal of Craniofacial Surgery · doi:10.1097/01.scs.0000157305.60505.b5 · Cited by 39
The influence of geometry on the stress distribution in joints ? a finite element analysis
Eckstein, F., Merz, B., Schmid, P., & Putz, R. V. (1994) · Anatomy and Embryology · doi:10.1007/bf00186828 · Cited by 37
Mechanical Significance of the Trabecular Microstructure of the Human Mandibular Condyle
van Ruijven, L. J., Giesen, E. B. W., & van Eijden, T. M. G. J. (2002) · Journal of Dental Research · doi:10.1177/154405910208101010 · Cited by 39
“Poisson ratios of 0.32 and 0.20 (Carter and Hayes, 1977; Kabel et al., 1999) were used for the cortical and the trabecular bone, respectively.”
MethodInfluentialCancellous Bone Strength Measurements with the Osteopenetrometer
Hvid, I., Andersen, K., & Olesen, S. (1984) · Engineering in Medicine · doi:10.1243/emed_jour_1984_013_019_02 · Cited by 37
Fractal-based image texture analysis of trabecular bone architecture
Jiang, C., Pitt, R. E., Bertram, J. E. A., & Aneshansley, D. J. (1999) · Medical & Biological Engineering & Computing · doi:10.1007/bf02513322 · Cited by 39
“For comparison, the mean intercept length method (WHITEHOUSE, 1974) was modified and used to characterise the textural anisotropy of the x-ray images. The grey-level images were rotated from 0 ~ to 180 ~ in 10 ~ increments. For each rotation, the image was globally thresholded based on the mean and standard deviation…”
MethodFrankel, V. H., & Pugh, J. (1984) · Springer eBooks · doi:10.1007/978-1-4612-5224-5_5 · Cited by 37
The influence of implant geometry on the stress distribution around dental implants
Cook, S. D., Klawitter, J. J., & WEINSTEIN, A. M. (1982) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820160406 · Cited by 37
A stereological study of trabecular architecture in the mandibular condyle of the pig
Teng, S., & Herring, S. W. (1995) · Archives of Oral Biology · doi:10.1016/0003-9969(94)00173-9 · Cited by 41
Takao-Kawabata, R., Isogai, Y., Takakura, A., Shimazu, Y., Sugimoto, E., Nakazono, O., Ikegaki, I., Kuriyama, H., Tanaka, S., Oda, H., et al. (2015) · Calcified Tissue International · doi:10.1007/s00223-015-9998-0 · Cited by 36
“Using TRI/3DFEM64 FEA software (RATOC System Engineering) [16, 17], the fracture load was determined as the level that induces fractures in 2.”
MethodInfluentialEffects of Materials of Cementless Femoral Stem on the Functional Adaptation of Bone
Gong, H., Wu, W., Fang, J., Dong, X., Zhao, M., & Guo, T. (2012) · Journal of Bionic Engineering · doi:10.1016/s1672-6529(11)60098-x · Cited by 36
Boughton, O. R., Ma, S., Cai, X., Yan, L., Peralta, L. M., Laugier, P., Marrow, T. J., Giuliani, F., Hansen, U. N., Abel, R. L., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-43686-6 · Cited by 36
Suzuki, T., Matsuura, Y., Yamazaki, T., Akasaka, T., Ozone, E., Matsuyama, Y., Mukai, M., Ohara, T., Wakita, H., Taniguchi, S., et al. (2019) · Bone · doi:10.1016/j.bone.2019.115212 · Cited by 36
Zhang, M., Grégory, T., Hansen, U., & Cheng, C. (2020) · Journal of Orthopaedic Research® · doi:10.1002/jor.24711 · Cited by 36
“80 g/cm(3)).(24) The linear relationship, which was created in terms of the two pairs of CT values and the corresponding densities, is represented by Equation (1) and was used to determine the density of each element in the FEM from the CT value where the element was located on the bone.”
MethodMarcus, R., & Majumder, S. (2001) · Elsevier eBooks · doi:10.1016/b978-012470862-4/50036-2 · Cited by 45
Effect of boundary conditions, impact loading and hydraulic stiffening on femoral fracture strength
Haider, I. T., Speirs, A., & Frei, H. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.07.004 · Cited by 36
Pietrzak, W. S., Lessek, T. P., & Perns, S. V. (2006) · The Journal of Foot & Ankle Surgery · doi:10.1053/j.jfas.2006.05.004 · Cited by 37
TAWARA, D., Sakamoto, J., Murakami, H., Kawahara, N., Juhachi, O. D. A., & Tomita, K. (2009) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2009.03.001 · Cited by 40
Gilchrist, S. E., Nishiyama, K. K., de Bakker, P., Guy, P., Boyd, S. K., Oxland, T. R., & Cripton, P. A. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.06.040 · Cited by 39
“, 1994), and could be counter to researchers showing that bone is a viscoelastic material (Fois et al., 2001; Carter and Hayes, 1977).”
BackgroundInfluentialMechanical implications of humero-ulnar incongruity — finite element analysis and experiment
Merz, B., Eckstein, F., Hillebrand, S., & Putz, R. V. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00014-6 · Cited by 36
Hing, K. A., Best, S. M., Tanner, K. E., Revell, P. A., & Bonfield, W. (1998) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/0954411981534204 · Cited by 36
Rogers-Foy, J. M., Powers, D. L., Brosnan, D. A., Barefoot, S. F., Friedman, R. J., & LaBerge, M. (1999) · Journal of Investigative Surgery · doi:10.1080/089419399272386 · Cited by 36
McClure, S. R., Glickman, L. T., Glickman, N. W., & Weaver, C. M. (2001) · American Journal of Veterinary Research · doi:10.2460/ajvr.2001.62.752 · Cited by 36
Prediction of Mechanical Properties of the Cancellous Bone of the Mandibular Condyle
van Ruijven, L. J., Giesen, E. B. W., Farella, M., & van Eijden, T. M. G. J. (2003) · Journal of Dental Research · doi:10.1177/154405910308201011 · Cited by 37
“The Young's modulus was 1 GPa, and the Poisson ratio was 0.3 (Carter and Hayes, 1977; Kabel et al., 1999b).”
BackgroundInfluentialThe Skeleton and its Adaptation to Gravity
Morey, E. R., Whalen, R. T., Arnaud, S. B., & van der Meulen, M. C. H. (1996) · Wiley eBooks · doi:10.1002/cphy.cp040131 · Cited by 39
Yazdanpanah, Z., Sharma, N. K., Raquin, A., Cooper, D. M. L., Chen, D., & Johnston, J. D. (2023) · BioMedical Engineering OnLine · doi:10.1186/s12938-023-01135-6 · Cited by 37
Biomechanical Response of the Human Clavicle: The Effects of Loading Direction on Bending Properties
Kemper, A. R., Stitzel, J. D., McNally, C., Gabler, H. C., & Duma, S. M. (2009) · Journal of Applied Biomechanics · doi:10.1123/jab.25.2.165 · Cited by 38
“Therefore, the that bone is a viscoelastic material, and therefore is affected by the rate of loading (McElhaney and Byars, 1965; Crowninshield and Pope, 1974; Wright and Hayes, 1976; Wood, 1971; Carter & Haynes, 1976; and”
BackgroundOn the effect of marrow in the mechanical behavior and crush response of trabecular bone
Halgrin, J., Chaari, F., & Markiewicz, É. (2011) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2011.09.003 · Cited by 35
“The difference in mechanical properties observed during our study and those reported by Carter and Hayes (1977) (compression under confinement conditions) can also confirm the hypothesis of marrow flow effect.”
BackgroundMethodResultInfluentialCortical bone mapping improves finite element strain prediction accuracy at the proximal femur
Schileo, E., Pitocchi, J., Falcinelli, C., & Taddei, F. (2020) · Bone · doi:10.1016/j.bone.2020.115348 · Cited by 35
Shu, J., Teng, H., Shao, B., Zheng, T., Liu, Y., & Liu, Z. (2020) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2020.105671 · Cited by 35
Spruijt, S., van der Linden, J. C., Dijkstra, P. D. S., Wiggers, T., Oudkerk, M., Snijders, C. J., van Keulen, F., Verhaar, J. A. N., Weinans, H., & Swierstra, B. A. (2006) · Acta Orthopaedica · doi:10.1080/17453670610046424 · Cited by 35
“The elastic modulus of each bone element was calculated from its bone mineral density using an experimentally determined relation (Carter and Hayes 1977).”
MethodInterstitial growth and remodeling of biological tissues: Tissue composition as state variables
Myers, K. M., & Ateshian, G. A. (2013) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2013.03.003 · Cited by 37
“Based on prior findings by many investigators (Carter and Hayes, 1976, 1977; Currey, 1988; Rice et al., 1988), they proposed that EY depended on the apparent bone density ρsr according to a power law EY ¼ cðρsrÞγ , ð2:10Þ where c and γ are material constants.”
ResultCrockett, K. L., Arnold, C. M., Farthing, J. P., Chilibeck, P. D., Johnston, J. D., Bath, B. L., Baxter-Jones, A. D. G., & Kontulainen, S. A. (2015) · Osteoporosis International · doi:10.1007/s00198-015-3160-8 · Cited by 39
“This BSIc equation represents compressive failure load (F) of bone and is based upon the classic experimental work of Carter and Hayes [33], which found bone to have an ultimate compressive stress (F/ToA) directly proportional to apparent density squared.”
MethodThe influence of fixation peg design on the shear stability of prosthetic implants
Giori, N. J., Beaupré, G. S., & Carter, D. R. P. (1990) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100080615 · Cited by 35
Self-citationSato, Y., Teixeira, E. R., Tsuga, K., & Shindoi, N. (1999) · Journal of Oral Rehabilitation · doi:10.1046/j.1365-2842.1999.00442.x · Cited by 35
Lievers, W. B., Poljsak, A. S., Waldman, S. D., & Pilkey, A. K. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.06.001 · Cited by 35
Hydraulic Strengthening Affects the Stiffness and Strength of Cortical Bone
Liebschner, M. A. K., & Keller, T. S. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-8960-0 · Cited by 38
Stiffness of trabecular bone of the tibial plateau in patients with rheumatoid arthritis of the knee
Yang, J.-P., Bogoch, E. R., Woodside, T., & Hearn, T. C. (1997) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(97)90011-5 · Cited by 35
Yeni, Y. N., Christopherson, G. T., Turner, A. S., Les, C. M., & Fyhrie, D. P. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.20128 · Cited by 39
Improvement of Numerical Ankle/Foot Model: Modeling of Deformable Bone
Beaugonin, M., Haug, E., & Cesari, D. (1997) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/973331 · Cited by 34
Human Bone strength Evaluation through different Mechanical Tests
Khan, S. N. (2010) · International Journal of Current Engineering and Technology · doi:10.14741/ijcet/spl.2.2014.102 · Cited by 34
Prot, M., Cloete, T. J., Saletti, D., & Laporte, S. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.02.021 · Cited by 38
“…some authors have reported studies on the mechanical response of cancellous bone at intermediate strain rates (from 1/s (Halgrin, 2009) to 10/s (Carter and Hayes, 1977; Linde et al., 1991)), there is a general lack of data for this range, which is mainly due to experimental difficulties…”
BackgroundResultEffect of baseplate positioning on fixation of reverse total shoulder arthroplasty
Zhang, M., Junaid, S., Grégory, T., Hansen, U., & Cheng, C. (2018) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2018.12.021 · Cited by 34
Austman, R. L., Milner, J. S., Holdsworth, D. W., & Dunning, C. (2009) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544119jeim553 · Cited by 34
Analysis of titanium induced CT artifacts in the development of biomechanical finite element models
Zannoni, C., Viceconti, M., Pierotti, L., & Cappello, A. (1998) · Medical Engineering & Physics · doi:10.1016/s1350-4533(98)00076-9 · Cited by 34
“A model [1] which relates elastic modulus to the cube of bone apparent density, rapp, was adopted as it is generally accepted in the literature [5,17].”
BackgroundMethodEpiphyseal-based designs for tibial plateau components—II. Stress analysis in the sagittal plane
Beaupré, G. S., Vasu, R., Carter, D. R. P., & Schurman, D. J. (1986) · Journal of Biomechanics · doi:10.1016/0021-9290(86)90171-5 · Cited by 34
Self-citationModified bone density-dependent orthotropic material model of human mandibular bone
Gačnik, F., Ren, Z., & Hren, N. I. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.09.013 · Cited by 37
Zhong, J., Guazzato, M., Chen, J., Zhang, Z., Sun, G., Huo, X., Liu, X., Ahmad, R., & Li, Q. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.103490 · Cited by 33
Metzner, F., Neupetsch, C., Fischer, J.-P., Drossel, W. G., Heyde, C.-E., & Schleifenbaum, S. (2021) · Scientific Reports · doi:10.1038/s41598-021-92685-z · Cited by 33
Pérez, M. Á., Fornells, P., Doblaré, M., & García‐Aznar, J. M. (2009) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840903045029 · Cited by 33
“In fact, there are different experimental relationships available in the literature relating the hounsfield units (HU) with the density and other mechanical characteristics of the bone tissue (Carter and Hayes 1977 ; Lotz et al.”
BackgroundTannous, R. E., Bandak, F. A., Toridis, T. G., & Eppinger, R. H. (1996) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/962427 · Cited by 33
Noukrati, H., Cazalbou, S., Demnati, I., Rey, C. C., Barroug, A., & Combes, C. (2015) · Materials Science and Engineering C · doi:10.1016/j.msec.2015.09.070 · Cited by 33
Anisotropic density growth of bone—A computational micro-sphere approach
Waffenschmidt, T., Menzel, A., & Kuhl, E. (2012) · International Journal of Solids and Structures · doi:10.1016/j.ijsolstr.2012.03.035 · Cited by 36
“In the mid 1970s, biomechanical engineers have proposed the first mechanistic models to characterise the isotropic functional adaptationof bone in response to mechanical loading, see Carter and Hayes (1977), Cowin and Hegedus (1976) and Cowin and Doty (2007).”
BackgroundPrimary and long-term stability of a short-stem hip implant
Dabirrahmani, D., Hogg, M., Kohan, L., & Gillies, M. (2010) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544119jeim704 · Cited by 36
Homologous growth hormone accelerates bone healing—a biomechanical and histological study
Kolbeck, S., Bail, H. J., Schmidmaier, G., Alquiza, M., Raun, K., Kappelgard, A., Flyvbjerg, A., Haas, N. P., & Raschke, M. J. (2003) · Bone · doi:10.1016/s8756-3282(03)00232-1 · Cited by 33
van der Meulen, M. C. H., Carter, D. R. P., & Beaupré, G. S. (2001) · Elsevier eBooks · doi:10.1016/b978-012470862-4/50018-0 · Cited by 33
Self-citationCody, D. C., McCubbrey, D. A., Divine, G., Gross, G. J., & Goldstein, S. A. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00133-6 · Cited by 41
“There has been disagreement regarding the usefulness of power functions to relate bone apparent density to mechanical properties vs a more simple linear regression approach (Carter and Hayes, 1977; Ciarelli et al., 1991; Ducheyne et al., 1977; Esses et al., 1989; Gibson, 1985; Keller, 1994; Lotz et al., 1990; Rice et…”
BackgroundMethodResultRole of the collar on the femoral stem of cemented total hip replacements
Fagan, M. J., & Lee, A. J. C. (1986) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(86)90061-0 · Cited by 33
The effect of the interface on the bone stresses beneath tibial components
Garg, A., & Walker, P. S. (1986) · Journal of Biomechanics · doi:10.1016/0021-9290(86)90113-2 · Cited by 33
Effective mechanical properties of diaphyseal cortical bone in the canine femur
Autefage, A., Palierne, S., Charron, C., & Swider, P. (2012) · The Veterinary Journal · doi:10.1016/j.tvjl.2012.04.001 · Cited by 37
Schädli, G. N., Vetsch, J. R., Baumann, R. P., de Leeuw, A. M., Wehrle, E., Rubert, M., & Müller, R. (2021) · Communications Biology · doi:10.1038/s42003-020-01635-4 · Cited by 32
Numerical simulation of strain-adaptive bone remodelling in the ankle joint
Bouguecha, A., Weigel, N., Behrens, B., Stukenborg-Colsman, C. M., & Waizy, H. (2011) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-10-58 · Cited by 35
Low-Pressure Foaming: A Novel Method for the Fabrication of Porous Scaffolds for Tissue Engineering
Chung, E. J., Sugimoto, M. J., Koh, J. L., & Ameer, G. A. (2011) · Tissue Engineering Part C Methods · doi:10.1089/ten.tec.2011.0289 · Cited by 33
“Although the mechanical properties of LPF scaffolds are inferior to those reported for bone (1–1,524 MPa, 211 – 78 MPa mean compression modulus), 33,58,59 the mechanical properties are similar to those of other biodegradable, porous scaffolds reported for tissue engineering applications.”
Dynamic bending tolerance and elastic-plastic material properties of the human femur.
Funk, J. R., Kerrigan, J. R., & Crandall, J. R. (2004) · PubMed · Cited by 32
High Strain Rate Testing of Bovine Trabecular Bone
Pilcher, A., Wang, X., Kaltz, Z., Garrison, J. G., Niebur, G. L., Mason, J., Song, B., Cheng, M., & Chen, W. (2009) · Journal of Biomechanical Engineering · doi:10.1115/1.4000086 · Cited by 32
Material properties of trabecular bone structures
Birnbaum, K., Sindelar, R., Gärtner, J., & Wirtz, D. C. (2002) · Surgical and Radiologic Anatomy · doi:10.1007/s00276-001-0399-x · Cited by 32
“Whereas in most uniaxially loaded bones, such as the human vertebrae, a rather uniform porous trabecular structure of vertical and transverse rods and plates is seen, the organization of cancellous bone bearing eccentric loads like the femoral head differs architecturally [5, 7].”
BackgroundInfluentialContributions of bone density and geometry to the strength of the human second metatarsal
Muehleman, C., Lidtke, R. H., Berzins, A., Becker, J. H., Shott, S., & Sumner, D. R. (2000) · Bone · doi:10.1016/s8756-3282(00)00370-7 · Cited by 34
A new imaging technique for measuring the surface strains applied to dentine
Palamara, J. E. A., Wilson, P. R., Thomas, C. D. L., & Messer, H. H. (2000) · Journal of Dentistry · doi:10.1016/s0300-5712(99)00054-8 · Cited by 32
The Bone Organ System: Form and Function
Morgan, E. F., Barnes, G. B., & Einhorn, T. A. (2008) · Elsevier eBooks · doi:10.1016/b978-012370544-0.50003-3 · Cited by 81
Brown, T. D., Pedersen, D. R., Radin, E. L., & Rose, R. M. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90005-x · Cited by 32
Material Properties of Cancellous Bone in Repetitive Axial Loading
Linde, F., Hvid, I., & Jensen, N. C. (1985) · Engineering in Medicine · doi:10.1243/emed_jour_1985_014_042_02 · Cited by 32
Holden, L., Pourcelot, P., Peaucelle, M., Falala, S., Robin, D., Crevier‐Denoix, N., & Château, H. (2010) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2010.493728 · Cited by 31
Proximal tibial trabecular bone mineral density is related to pain in patients with osteoarthritis
Burnett, W. D., Kontulainen, S. A., McLennan, C. E., Hazel, D., Talmo, C. T., Wilson, D. R., Hunter, D. J., & Johnston, J. D. (2017) · Arthritis Research & Therapy · doi:10.1186/s13075-017-1415-9 · Cited by 32
“becular bone density in OA [14–16], which is directly linked to the elastic modulus of epiphyseal bone [18],”
BackgroundElastic Constants of Cancellous Bone
Cowin, S. C. (2001) · CRC Press eBooks · doi:10.1201/b14263-21 · Cited by 31
Bhakat, U., & Bandyopadhayay, R. (2013) · Open Journal of Orthopedics · doi:10.4236/ojo.2013.37053 · Cited by 31
“Because of the complex stress configuration in this region and its nonhomogeneous osseous structure and geometry, fractures occur along the path of least resistance through the proximal femur [1].”
BackgroundLoad transmission through a healing tibial fracture
Vijayakumar, V., Marks, L., Bremmer-Smith, A., Hardy, J., & Gardner, T. (2005) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2005.08.011 · Cited by 31
Metadata
- Authors
- Carter, D., & Hayes, W.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1977-10
- Volume
- 59
- Issue
- 7
- Pages
- 954-962
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W1901463649
- Semantic Scholar
- cc21d6cd590fb46c2bd9cfd768da63c8012862ee
- Cited by
- 2,001
- References
- 0
- Citations by year
- 2026: 30 · 2025: 31 · 2024: 41 · 2023: 40 · 2022: 60 · 2021: 61 · 2020: 57 · 2019: 66 · 2018: 59 · 2017: 55 · 2016: 55 · 2015: 67 · 2014: 79 · 2013: 68 · 2012: 67
- FWCI
- 18.23
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Bone and Joint Surgery (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Physical Sciences › Engineering › Mechanical Engineering › Cellular and Composite Structures
- Keywords
- trabecular bone, strain rate sensitivity, bone stiffness, energy absorption, marrow, porous structure, apparent density, human bone, bovine bone
- MeSH terms
- Animals, Bone and Bones, Cattle, Humans, Stress, Mechanical, Tensile Strength
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.