The compressive behavior of bone as a two-phase porous structure
The DOI matches its Crossref record.
Abstract
Compression tests of human and bovine trabecular bone specimens with and without marrow in situ were conducted at strain rates of from 0.001 to 10.0 per second. A porous platen above the specimens allowed the escape of marrow during testing. The presence of marrow increased the strength, modulus, and energy absorption of specimens only at the highest strain rate of 10.0 per second. This enhancement of material properties at the highest strain rate was due primarily to the restricted viscous flow of marrow through the platen rather than the flow through the pores of the trabecular bone. In specimens without marrow, the strength was proportional to the square of the apparent density and the modulus was proportional to the cube of the apparent density. Both strength and modulus were approximately proportional to the strain rate raised to the 0.06 power. These power relationships, which were shown to hold for all bone in the skeleton, allow meaningful predictions of bone tissue strength and stiffness based on in vivo density measurements.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The compressive modulus and compressive strength are proportional to the strain rate raised to the power of 0.06 (100, 101).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [101]
Citations
Cited by
Items 101–200 of 1,002
The 100 classic papers of orthopaedic surgery: A BIBLIOMETRIC ANALYSIS
Kelly, J. C., Glynn, R. W., O’Briain, D. E., Felle, P., & McCabe, J. P. (2010) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.92b10.24867 · Cited by 232
Young's modulus, bending strength, and tissue physical properties of human compact bone
Keller, T. S., Mao, Z., & Spengler, D. M. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080416 · Cited by 230
Elastic properties of cancellous bone: Measurement by an ultrasonic technique
Ashman, R. B., Corin, J. D., & Turner, C. H. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90327-7 · Cited by 227
The underestimation of Young's modulus in compressive testing of cancellous bone specimens
Odgaard, A., & Linde, F. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90333-i · Cited by 225
Rho, J.-Y. (1996) · Ultrasonics · doi:10.1016/s0041-624x(96)00078-9 · Cited by 225
Hansson, S., & Werke, M. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00164-7 · Cited by 240
“The strength of cortical bone varies from patient to patient, between different anatomical locations and is also dependent upon the strain rate (Carter and Hayes, 1977).”
BackgroundWehrli, F. W. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20807 · Cited by 223
“Carter and Hayes (8) measured the compressive strength of TB ex vivo in specimens using material testing techniques, concluding that the strength is proportional to the square of the apparent density while the modulus is proportional to the cube of apparent density.”
BackgroundMethodHuiskes, R., Weinans, H., & Dalstra, M. (1989) · Orthopedics · doi:10.3928/0147-7447-19890901-15 · Cited by 223
Marquet, F., Pernot, M., Aubry, J.-F., Montaldo, G., Marsac, L., Tanter, M., & Fink, M. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/9/001 · Cited by 222
Kerner, J., Huiskes, R., van Lenthe, H., Weinans, H., van Rietbergen, B., Engh, C. A., & Amis, A. A. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00041-x · Cited by 245
“Young's moduli of the elements representing the bone were determined from their apparent densities using cubic relationship proposed by Carter and Hayes (1977), E"c, where c"3790 MPa g\ cm. Poisson's ratio of bone was set to 0.35 and the material was assumed to be linearly elastic and isotropic.”
MethodInfluentialBailey, A. J., Sims, T. J., Ebbesen, E. N., Mansell, J. P., Thomsen, J. S., & Mosekilde, L. (1999) · Calcified Tissue International · doi:10.1007/s002239900683 · Cited by 219
“Fit curves with power functions have been applied, as this relationship between apparent density and the biomechanical parameters has previously been established [35, 36].”
MethodA comparative study on different methods of automatic mesh generation of human femurs
Viceconti, M., Bellingeri, L., Cristofolini, L., & Toni, A. (1998) · Medical Engineering & Physics · doi:10.1016/s1350-4533(97)00049-0 · Cited by 217
Long-term fatigue behavior of compact bone at low strain magnitude and rate
Schaffler, M. B., Radin, E. L., & Burr, D. B. (1990) · Bone · doi:10.1016/8756-3282(90)90087-f · Cited by 215
Effect of porosity on the fluid flow characteristics and mechanical properties of tantalum scaffolds
Shimko, D. A., Shimko, V. F., Sander, E. A., Dickson, K. F., & Nauman, E. A. (2005) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.30229 · Cited by 215
Frontiers in growth and remodeling
Menzel, A., & Kuhl, E. (2012) · Mechanics Research Communications · doi:10.1016/j.mechrescom.2012.02.007 · Cited by 214
Is Quantitative Ultrasound Dependent on Bone Structure? A Reflection
Njeh, C. F., Fuerst, T., Diessel, E., & Genant, H. K. (2001) · Osteoporosis International · doi:10.1007/pl00020939 · Cited by 214
“The anisotropy of QUS indicates a relationship with mechanical properties since it is known that the mechanical properties of bone are also anisotropic [5,136,137].”
Castilho, M., Moseke, C., Ewald, A., Gbureck, U., Groll, J., Pires, I., Teßmar, J., & Vorndran, E. (2014) · Biofabrication · doi:10.1088/1758-5082/6/1/015006 · Cited by 211
Material properties assignment to finite element models of bone structures: a new method
Zannoni, C., Mantovani, R., & Viceconti, M. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(98)00081-2 · Cited by 210
A mathematical model for simulating the bone remodeling process under mechanical stimulus
Li, J., Li, H., Shi, L., Fok, A. S. L., Ucer, C., Devlin, H., Horner, K., & Silikas, N. (2007) · Dental Materials · doi:10.1016/j.dental.2006.10.004 · Cited by 209
Kabel, J., van Rietbergen, B., Odgaard, A., & Huiskes, R. (1999) · Bone · doi:10.1016/s8756-3282(99)00190-8 · Cited by 206
“[ A D E D B F E F C ]O¡ eigenanalysis[ e1 0 0 0 e2 0 0 0 e2 ] (1)”
Tibial Stress Injuries: An Aetiological Review for the Purposes of Guiding Management
Beck, B. R. (1998) · Sports Medicine · doi:10.2165/00007256-199826040-00005 · Cited by 206
“[59-61] This property renders bone more susceptible to fracture during the period of adaptation, a problem that is compounded by a strain-remodelling positive feedback mechanism.”
BackgroundBone Matters: Are Density Increases Necessary to Reduce Fracture Risk?
Faulkner, K. G. (2000) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2000.15.2.183 · Cited by 205
“(22) Yet it is the trabecular bone that (1) provides weight-bearing capacity and (2) responds to antiresorptive therapy.”
BackgroundWachter, N. J., Krischak, G. D., Mentzel, M., Sarkar, M. R., Ebinger, T., Kinzl, L., Claes, L., & Augat, P. (2002) · Bone · doi:10.1016/s8756-3282(02)00779-2 · Cited by 203
Mechanical properties of cancellous bone in the human mandibular condyle are anisotropic
Giesen, E. B. W., Ding, M., Dalstra, M., & van Eijden, T. M. G. J. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00030-6 · Cited by 201
Bouxsein, M. L., & Radloff, S. E. (1997) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1997.12.5.839 · Cited by 200
Human vertebral body apparent and hard tissue stiffness
Hou, F. J., Lang, S. M., Hoshaw, S. J., Reimann, D. A., & Fyhrie, D. P. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00110-9 · Cited by 197
Nonlinear Finite Element Model Predicts Vertebral Bone Strength and Fracture Site
Imai, K., Ohnishi, I., Bessho, M., & Nakamura, K. (2006) · Spine · doi:10.1097/01.brs.0000225993.57349.df · Cited by 196
Cullinane, D. M., & Einhorn, T. A. (2002) · Principles of Bone Biology · doi:10.1016/b978-012098652-1.50104-9 · Cited by 195
Dental implant induced bone remodeling and associated algorithms
Lin, D., Li, Q., Li, W., & Swain, M. (2009) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2008.11.007 · Cited by 194
Effects of material properties of femoral hip components on bone remodeling
Weinans, H., Huiskes, R., & Grootenboer, H. J. (1992) · Journal of Orthopaedic Research · doi:10.1002/jor.1100100614 · Cited by 194
Weinans, H., Huiskes, R., Van Rietbergen, B., Sumner, D. R., Turner, T. M., & Galante, J. O. (1993) · Journal of Orthopaedic Research · doi:10.1002/jor.1100110405 · Cited by 194
Variability and anisotropy of mechanical behavior of cortical bone in tension and compression
Li, S., Demirci, E., & Silberschmidt, V. V. (2013) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2013.02.021 · Cited by 193
“Using a modified Voigt-Reuss-Hill (VRH) averaging scheme based on (Bonfield and Clark, 1973; Carter and Hayes, 1977), the effective Young’s modulus was calculated according to the following equation: Etotal = (EO×VO+EI×VI+EP×VP)×(1-p)3.”
MethodDeterminants of skeletal fragility
Bouxsein, M. L. (2005) · Best Practice & Research Clinical Rheumatology · doi:10.1016/j.berh.2005.07.004 · Cited by 193
The role of an effective isotropic tissue modulus in the elastic properties of cancellous bone
Kabel, J., van Rietbergen, B., Dalstra, M., Odgaard, A., & Huiskes, R. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00045-7 · Cited by 191
“However, the predictive value of bone volume fraction for bone strength is not very high, usually only 40}80% of the variation in strength can be explained by the volume fraction alone (Carter and Hayes, 1977; Ciarelli et al., 1991; Rice et al., 1988).”
BackgroundFinite element modelling of primary hip stem stability: The effect of interference fit
Kadir, M. R. A., Hansen, U., Klabunde, R., Lucas, D., & Amis, A. A. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.10.009 · Cited by 190
“The modulus of elasticity of individual elements was then calculated from the assigned apparent densities using the cubic relationship proposed by Carter and Hayes (1977) .”
MethodBrolin, K., & Halldin, P. (2004) · Spine · doi:10.1097/01.brs.0000090820.99182.2d · Cited by 189
Some basic relationships between density values in cancellous and cortical bone
Zioupos, P., Cook, R. B., & Hutchinson, J. R. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.03.025 · Cited by 187
“-‘‘- Ashman and Rho (1988) ‘y specifically, the density of the structure of cancellous bone previously referred to as apparent density by Carter and Hayes (1977) and as bulk density (Martens et al., 1983), varies from approximately 100–1000kgm 3.’”
BackgroundInfluentialEbbesen, E. N., Thomsen, J. S., Beck-Nielsen, H., Nepper-Rasmussen, H. J., & Mosekilde, L. (1999) · Bone · doi:10.1016/s8756-3282(99)00216-1 · Cited by 187
Chen, P.-Y., Stokes, A. G., & McKittrick, J. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2008.09.011 · Cited by 186
“Carter and Hayes [54] have proposed an expression for the elastic modulus that is proportional to (1 – p) 3 , and this expression also does not approximate the measured elastic modulus.”
Anatomical variation of orthotropic elastic moduli of the proximal human tibia
Ashman, R. B., Rho, J. Y., & Turner, C. H. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90073-0 · Cited by 184
Van Rietbergen, B., Odgaard, A., Kabel, J., & Huiskes, R. (1998) · Journal of Orthopaedic Research · doi:10.1002/jor.1100160105 · Cited by 184
Abdelaziz, A. G., Nageh, H., Abdo, S. M., Abdalla, M. S., Amer, A. A., Abdal-hay, A., & Barhoum, A. (2023) · Bioengineering · doi:10.3390/bioengineering10020204 · Cited by 182
“These lamellae are arranged concentrically around a central channel (Haversian channel) to form what are known as osteons [39].”
BackgroundAge variations in the properties of human tibial travecular bone
Ding, M. L., Dalstra, M., Danielsen, C. C., Kabel, J., Hvid, I., & Linde, F. (1997) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.79b6.7538 · Cited by 181
“specimens, a method of preparation that tends to alter the mechanical properties.(1) The use of wet, non-defatted specimens has been found to give better representation of the in vivo mechanical properties.”
MethodCompressive behaviour of child and adult cortical bone
Öhman, C., Baleani, M., Pani, C., Taddei, F., Alberghini, M., Viceconti, M., & Manfrini, M. (2011) · Bone · doi:10.1016/j.bone.2011.06.035 · Cited by 181
“Those findings suggest that the good correlations reported between tissue density and mechanical properties [14,25,27,28] are valid only for adult bone tissue.”
BackgroundInfluentialThe effect of constraint on the mechanical behaviour of trabecular bone specimens
Linde, F., & Hvid, I. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90209-1 · Cited by 181
“, 1987), and apparent density computed from the weight of the hydrated defatted bone specimen and the bulk volume (Galante et al., 1970; Behrens et al., 1974; Carter and Hayes, 1977; Ducheyne et al., 1977; Favenesi et al., 1984).”
BackgroundCortical Porosity Identifies Women With Osteopenia at Increased Risk for Forearm Fractures
Bala, Y., Zebaze, R., Ghasem-Zadeh, A., Atkinson, E. J., Iuliano, S., Peterson, J. M., Amin, S., Bjørnerem, Å., Melton, L. J., Johansson, H., et al. (2014) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.2167 · Cited by 181
The effect of muscle loading on the simulation of bone remodelling in the proximal femur
Bitsakos, C., Kerner, J., Fisher, I. A., & Amis, A. A. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.03.005 · Cited by 181
Simpson, R. L., Wiria, F. E., Amis, A. A., Chua, C. K., Leong, K. F., Hansen, U. N., Chandrasekaran, M., & Lee, M. W. (2008) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.30839 · Cited by 181
A model of vertebral trabecular bone architecture and its mechanical properties
Jensen, K. S., Mosekilde, L., & Mosekilde, L. (1990) · Bone · doi:10.1016/8756-3282(90)90137-n · Cited by 180
Fibre-reinforced calcium phosphate cements: A review
Canal, C., & Ginebra, M. P. (2011) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2011.06.023 · Cited by 180
“5 and 45 MPa (Carter and Hayes, 1977), or fall in the lower range of the compressive strength of cortical bone, that varies between 90 and 209 MPa (Ontañón et al.”
BackgroundInfluentialShefelbine, S. J., Simon, U., Claes, L., Gold, A., Gabet, Y., Bab, I., Müller, R., & Augat, P. (2005) · Bone · doi:10.1016/j.bone.2004.11.007 · Cited by 179
Mechanical Properties of Tissue
Duck, F. A. (1990) · Physical Properties of Tissues · doi:10.1016/b978-0-12-222800-1.50009-7 · Cited by 175
Migration, Stem Shape, and Surface Finish in Cemented Total Hip Arthroplasty
Huiskes, R., Verdonschot, N. J. J., & Nivbrant, B. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199810000-00011 · Cited by 175
Mechanical properties of trabecular bone. Dependency on strain rate
Linde, F., Nørgaard, P., Hvid, I., Odgaard, A., & Søballe, K. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90305-7 · Cited by 171
Bone Strength: The Whole Is Greater Than the Sum of Its Parts
Davison, K. S., Siminoski, K., Adachi, J. D., Hanley, D. A., Goltzman, D., Hodsman, A. B., Josse, R., Kaiser, S., Olszynski, W. P., Papaioannou, A., et al. (2006) · Seminars in Arthritis and Rheumatism · doi:10.1016/j.semarthrit.2006.04.002 · Cited by 171
The Musculoskeletal Effects of Smoking
Porter, S. E., & Hanley, E. N. (2001) · Journal of the American Academy of Orthopaedic Surgeons · doi:10.5435/00124635-200101000-00002 · Cited by 171
Tanaka, E. I., Tanne, K., & Sakuda, M. (1994) · Medical Engineering & Physics · doi:10.1016/1350-4533(94)90058-2 · Cited by 185
Validation of an automated method of three-dimensional finite element modelling of bone
Keyak, J. H., Fourkas, M. G., Meagher, J. M., & Skinner, H. B. (1993) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(93)90066-8 · Cited by 171
Finite element studies of some juxtarticular stress changes due to localized subchondral stiffening
Brown, T. D., Radin, E. L., Martin, R. B., & Burr, D. B. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90075-7 · Cited by 171
Yosibash, Z., Trabelsi, N., & Milgrom, C. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.06.017 · Cited by 170
Whole Bone Mechanics and Bone Quality
Cole, J. H., & van der Meulen, M. C. H. (2011) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-011-1784-3 · Cited by 169
“Mechanical properties scale with bone mass by a power law relationship, so small changes in mass effect large changes in bone strength [24, 47, 100].”
Hierarchical microimaging of bone structure and function
Müller, R. (2009) · Nature Reviews Rheumatology · doi:10.1038/nrrheum.2009.107 · Cited by 168
Connectivity and the elastic properties of cancellous bone
Kabel, J., Odgaard, A., van Rietbergen, B., & Huiskes, R. (1999) · Bone · doi:10.1016/s8756-3282(98)00164-1 · Cited by 168
Why Do Woodpeckers Resist Head Impact Injury: A Biomechanical Investigation
Wang, L., Cheung, J. T.-M., Pu, F., Li, D., Zhang, M., & Fan, Y. (2011) · PLoS ONE · doi:10.1371/journal.pone.0026490 · Cited by 168
“Established reasonable correlations between bone elastic modulus, strength and structural parameters derived from micro-CT images showed that the elastic properties of cranial bone could be estimated by measuring its volume fraction (or density) [28–31].”
BackgroundJacobs, C. R., Levenston, M. E., Beaupré, G. S., Simo, J. C., & Carter, D. R. P. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00087-k · Cited by 168
“By assuming that this scaling takes the same form as ultimate stress (Carter and Hayes, 1977) we have do ;i:0 otherwise. where Y:(, \ \i*"'ur )''^ do / /o^\' \ " =r(*[;/ Yo^.”
BackgroundSelf-citationBoyle, C., & Kim, I. Y. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.11.029 · Cited by 180
Yang, K. H., Hu, J., White, N. A., King, A. I., Chou, C. C., & Prasad, P. (2006) · SAE Technical Paper Series · doi:10.4271/2006-22-0017 · Cited by 165
Lewis, G., & Nyman, J. S. (2008) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31092 · Cited by 165
Aversa, R. M., Petrescu, F. I. T., Petrescu, R. V., & Apicella, A. M. (2016) · American Journal of Applied Sciences · doi:10.3844/ajassp.2016.1060.1067 · Cited by 165
“Internal structure of the femur proximal end defined by the Ward triangle is the anatomical region where the osteoporotic phenomenon alters the structural equilibrium increasing the possibility of femur neck fracture (Ashman and Rho, 1988; Burnstein et al., 1976; Carter and Hayes, 1977).”
BackgroundPorosity of human mandibular condylar bone
Renders, G. A. P., Mulder, L., Van Ruijven, L. J., & Van Eijden, T. M. G. J. (2007) · Journal of Anatomy · doi:10.1111/j.1469-7580.2007.00693.x · Cited by 164
“Porosity is considered to be inversely proportional to several mechanical properties, such as bone strength and stiffness (e.g. Carter & Hayes, 1977; Schaffler & Burr, 1988; McCalden et al. 1993; Jordan et al. 2000; Borah et al. 2001; Giesen et al. 2004).”
BackgroundRole of trabecular morphology in the etiology of age-related vertebral fractures
Snyder, B. D., Piazza, S., Edwards, W. T., & Hayes, W. C. (1993) · Calcified Tissue International · doi:10.1007/bf01673396 · Cited by 164
Self-citationZimmermann, E. A., Gludovatz, B., Schaible, E., Busse, B., & Ritchie, R. O. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.03.066 · Cited by 163
Trabecular bone fracture healing simulation with finite element analysis and fuzzy logic
Shefelbine, S. J., Augat, P., Claes, L., & Simon, U. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.10.019 · Cited by 163
Biomechanics of Fracture: Is Bone Mineral Density Sufficient to Assess Risk?
Mccreadie, B. R., & Goldstein, S. A. (2000) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2000.15.12.2305 · Cited by 163
Validation of a C2–C7 cervical spine finite element model using specimen-specific flexibility data
Kallemeyn, N. A., Gandhi, A., Kode, S., Shivanna, K. H., Smucker, J. D., & Grosland, N. M. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.03.001 · Cited by 162
Serdar Göktepe, A., Abilez, O. J., & Kuhl, E. (2010) · Journal of the Mechanics and Physics of Solids · doi:10.1016/j.jmps.2010.07.003 · Cited by 171
“URL: http://biomechanics.stanford.edu (E. Kuhl). between density growth common to hard tissues such as bone (Carter and Hayes, 1977; Cowin and Hegedus, 1976; Kuhl et al., 2003; Kuhl and Steinmann, 2003c), tip growth common to plants (Dumais et al., 2006), surface growth common to sea shells or…”
BackgroundCan Fiber Posts Increase Root Stresses and Reduce Fracture?
Santos, A. F. V., Meira, J. B. C., Tanaka, C. B., Xavier, T. A., Ballester, R. Y., Lima, R. G., Pfeifer, C. S., & Versluis, A. (2010) · Journal of Dental Research · doi:10.1177/0022034510363382 · Cited by 161
Willie, B. M., Birkhold, A. I., Razi, H., Thiele, T., Aido, M., Kruck, B., Schill, A., Checa, S., Main, R. P., & Duda, G. N. (2013) · Bone · doi:10.1016/j.bone.2013.04.023 · Cited by 161
“Assuming a linear relation between TMD and microCT attenuation values and using the following power relationship between Young's modulus (E) and density (ρ): E = Constant · ρ [73–75]; Young's moduli in the fibula and proximal tibia were calculated as ratios of the distal tibia.”
MethodTrabecular bone modulus and strength can depend on specimen geometry
Keaveny, T. M., Borchers, R. E., Gibson, L. J., & Hayes, W. C. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90059-n · Cited by 160
Self-citationMosekilde, L., Kragstrup, J., & Richards, A. (1987) · Calcified Tissue International · doi:10.1007/bf02556693 · Cited by 159
Razfar, N., Reeves, J. M., Langohr, G. D. G., Willing, R. T., Athwal, G. S., & Johnson, J. A. (2016) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2015.11.011 · Cited by 167
Kaneko, T. S., Pejcic, M. R., Tehranzadeh, J., & Keyak, J. H. (2003) · Medical Engineering & Physics · doi:10.1016/s1350-4533(03)00030-4 · Cited by 158
Huang, H., Lee, S.-Y., Yeh, C., & Lin, C. (2002) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2002.130108.x · Cited by 156
A modified method for assigning material properties to FE models of bones
Helgason, B., Taddei, F., Pálsson, H., Schileo, E., Cristofolini, L., Viceconti, M., & Brynjólfsson, S. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.05.006 · Cited by 155
Pena, F. A., Grøntvedt, T., Brown, G. A., Aune, A. K., & Engebretsen, L. (1996) · The American Journal of Sports Medicine · doi:10.1177/036354659602400314 · Cited by 155
Accretion of Bone Quantity and Quality in the Developing Mouse Skeleton
Miller, L. M., Little, W. C., Schirmer, A., Sheik, F., Busa, B., & Judex, S. (2007) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.070402 · Cited by 153
“Micromechanical models describing BMD and stiffness have shown that mature trabecular bone behaves as a densely porous material, where its stiffness is proportional to the cube of the density.((31)) A similar relationship was found for mature compact bone.”
BackgroundIn vitro -Osteoclastic Activity Studies on Surfaces of 3D Printed Calcium Phosphate Scaffolds
Detsch, R., Schaefer, S., Deisinger, U., Ziegler, G., Seitz, H., & Leukers, B. (2010) · Journal of Biomaterials Applications · doi:10.1177/0885328210373285 · Cited by 152
Material Properties of Human Rib Cortical Bone from Dynamic Tension Coupon Testing
Kemper, A. R., McNally, C., Kennedy, E. A., Manoogian, S. J., Rath, A. L., Ng, T. P., Stitzel, J. D., Smith, E. P., Duma, S. M., & Matsuoka, F. (2005) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/2005-22-0010 · Cited by 180
Les, C. M., Keyak, J. H., Stover, S. M., Taylor, K., & Kaneps, A. J. (1994) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100120610 · Cited by 152
“These data are consistent with other studies (11,25,26,42,43) that demonstrated important dependencies of stiffness and strength on porosity and mineralization.”
BackgroundResultViceconti, M., Davinelli, M., Taddei, F., & Cappello, A. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.030 · Cited by 151
“, 1998); * The constitutive laws used to model the mechanical behaviour of the bone tissues may not be adequate or their parameters accurately identified (Pattijn et al., 2001; Zannoni et al., 1998; Kopperdahl et al., 2002; Keller, 1994; Carter and Hayes, 1977); * The finite element mesh may be topologically inaccurat…”
BackgroundCarbonated Apatite Cement Augmentation of Pedicle Screw Fixation in the Lumbar Spine
Lotz, J. C., Hu, S. S., Chiu, D. F. M., Yu, M., Colliou, O. K., & Poser, R. D. (1997) · Spine · doi:10.1097/00007632-199712010-00003 · Cited by 151
Development of a Finite Element Model of the Human Neck
Yang, K. H., Zhu, F., Luan, F., Zhao, L., & Begeman, P. C. (1998) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/983157 · Cited by 149
Wagner, A., Krach, W., Schicho, K., Undt, G., Ploder, O., & Ewers, R. (2002) · Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology · doi:10.1067/moe.2002.126451 · Cited by 149
Age-related changes in trabecular bone microstructures: global and local morphometry
Stauber, M., & Müller, R. (2005) · Osteoporosis International · doi:10.1007/s00198-005-0025-6 · Cited by 170
“This was based on the intuitive idea that the mechanical properties of trabecular bone depend strongly on its apparent density or bone volume [19, 20], and it became an indisputable fact that bone is lost in aging people.”
The biomechanics of interference screw fixation of patellar tendon anterior cruciate ligament grafts
Brown, C. H., Hecker, A. T., Hipp, J. A., Myers, E. R., & Hayes, W. C. (1993) · The American Journal of Sports Medicine · doi:10.1177/036354659302100622 · Cited by 147
Self-citationStauber, M., Rapillard, L., van Lenthe, H., Zysset, P. K., & Müller, R. (2006) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.060102 · Cited by 146
Effect of cement pressure and bone strength on polymethylmethacrylate fixation
Askew, M. J., Steege, J. W., Lewis, J. L., Ranieri, J. R., & Wixson, R. L. (1983) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100010410 · Cited by 146
Bay, B. K. (1995) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100130214 · Cited by 156
Jones, G., & Dwyer, T. (1998) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.83.12.5353 · Cited by 138
Mosekilde, L., Bentzen, S. M., Ørtoft, G., & Jørgensen, J. (1989) · Bone · doi:10.1016/8756-3282(89)90080-x · Cited by 161
Metadata
- Authors
- Carter, D., & Hayes, W.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1977-10
- Volume
- 59
- Issue
- 7
- Pages
- 954-962
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W1901463649
- Semantic Scholar
- cc21d6cd590fb46c2bd9cfd768da63c8012862ee
- Cited by
- 2,001
- References
- 0
- Citations by year
- 2026: 30 · 2025: 31 · 2024: 41 · 2023: 40 · 2022: 60 · 2021: 61 · 2020: 57 · 2019: 66 · 2018: 59 · 2017: 55 · 2016: 55 · 2015: 67 · 2014: 79 · 2013: 68 · 2012: 67
- FWCI
- 18.23
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Bone and Joint Surgery (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Physical Sciences › Engineering › Mechanical Engineering › Cellular and Composite Structures
- Keywords
- trabecular bone, strain rate sensitivity, bone stiffness, energy absorption, marrow, porous structure, apparent density, human bone, bovine bone
- MeSH terms
- Animals, Bone and Bones, Cattle, Humans, Stress, Mechanical, Tensile Strength
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.