The compressive behavior of bone as a two-phase porous structure
The DOI matches its Crossref record.
Abstract
Compression tests of human and bovine trabecular bone specimens with and without marrow in situ were conducted at strain rates of from 0.001 to 10.0 per second. A porous platen above the specimens allowed the escape of marrow during testing. The presence of marrow increased the strength, modulus, and energy absorption of specimens only at the highest strain rate of 10.0 per second. This enhancement of material properties at the highest strain rate was due primarily to the restricted viscous flow of marrow through the platen rather than the flow through the pores of the trabecular bone. In specimens without marrow, the strength was proportional to the square of the apparent density and the modulus was proportional to the cube of the apparent density. Both strength and modulus were approximately proportional to the strain rate raised to the 0.06 power. These power relationships, which were shown to hold for all bone in the skeleton, allow meaningful predictions of bone tissue strength and stiffness based on in vivo density measurements.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The compressive modulus and compressive strength are proportional to the strain rate raised to the power of 0.06 (100, 101).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [101]
Citations
Cited by
Items 801–900 of 1,002
Hopkinson bar techniques for the intermediate strain rate testing of bovine cortical bone
Cloete, T. J., Paul, G., & Ismail, E. B. (2014) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2013.0210 · Cited by 31
“1 s−1, which are relevant to activities such as walking and running [8].”
Dynamic response of the pelvis under side impact load ? a three-dimensional finite element approach
Majumder, S., Roychowdhury, A., & Pal, S. (2004) · International Journal of Crashworthiness · doi:10.1533/cras.9.1.89.27116 · Cited by 31
Creep of trabecular bone from the human proximal tibia
Novitskaya, E. E., Zin, C., Chang, N., Cory, E., Chen, P., DʼLima, D. D., Sah, R. L., & McKittrick, J. M. (2014) · Materials Science and Engineering C · doi:10.1016/j.msec.2014.03.057 · Cited by 31
Baharuddin, M. Y., Salleh, S., Zulkifly, A. H., Lee, M. H., Noor, A. M., Harris, A. R. A., Majid, N. A., & Kader, A. S. A. (2014) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-15-30 · Cited by 31
“The correlation proposed by Carter and Hayes between the modulus of elasticity of the bone, E and its apparent density was used in this study as shown in equation 1 [26].”
MethodLes, C. M., Spence, C. A., Vance, J. L., Christopherson, G. T., Patel, B., Turner, A. S., Divine, G., & Fyhrie, D. P. (2004) · Bone · doi:10.1016/j.bone.2004.04.006 · Cited by 31
Avval, P. T., Klika, V., & Bougherara, H. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4026642 · Cited by 31
A new method for the automatic mesh generation of bone segments from CT data
Viceconti, M., Zannoni, C., Testi, D., & Cappello, A. (1999) · Journal of Medical Engineering & Technology · doi:10.1080/030919099294339 · Cited by 31
Martínez‐Reina, J., Ojeda, J., & Mayo, J. M. (2016) · PLoS ONE · doi:10.1371/journal.pone.0148603 · Cited by 40
Contemporary Topics about Phosphorus in Biology and Materials
Churchill, D. G., Sikirić, M. D., Čolović, B., & Milhofer, H. F. (2019) · IntechOpen eBooks · doi:10.5772/intechopen.80727 · Cited by 35
Al‐Sukhun, J., Kontio, R. K., & Lindqvist, C. (2006) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.joms.2005.11.015 · Cited by 31
Numerical analysis of a strain-adaptive bone remodelling problem
Fernández, J. R., García‐Aznar, J. M., Martínez, R., & Viaño, J. M. (2010) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2010.01.005 · Cited by 31
A method for patient-specific evaluation of vertebral cancellous bone strength: In vitro validation
Diamant, I., Shahar, R., Masharawi, Y., & Gefen, A. (2006) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2006.10.005 · Cited by 31
“In vitro, it was demonstrated empirically that thinning of trabeculae and loss of connectivity cause significant deterioration of whole bone strength and stiffness under quasi-static as well as impact loads (Carter and Hayes, 1977; Gibson, 1985; Passi and Gefen, 2005).”
BackgroundFree surface density and microdamage in the bone remodeling equation: Theoretical considerations
Rouhi, G., Epstein, M., Sudak, L. J., & Herzog, W. (2006) · International Journal of Engineering Science · doi:10.1016/j.ijengsci.2006.02.001 · Cited by 34
Cornu, O., Bavadekar, A., Godts, B., Tomme, J. V., Delloye, C., & Banse, X. (2003) · Acta Orthopaedica Scandinavica · doi:10.1080/00016470310017947 · Cited by 31
“In such conditions, the flow of liquids may play an important role (Carter and Hayes 1977) and hence, the replacement of viscous bone marrow by saline in the freeze-dried bone may accelerate the compaction of the grafts (Kärrholm et al. 1999).”
BackgroundSeparate effects of osteoporosis and density on the strength and stiffness of human cancellous bone
Hodgskinson, R., & Currey, J. D. (1993) · Clinical Biomechanics · doi:10.1016/0268-0033(93)90036-h · Cited by 36
Taaffe, D. R., Lang, T., Fuerst, T. P., Cauley, J. A., Nevitt, M. C., & Harris, T. B. (2003) · Annals of Human Biology · doi:10.1080/0301446031000089588 · Cited by 32
“Given that the strength of bone tissue is proportional to the square of its apparent density (Carter and Hayes 1977), we can infer that bone strength in our cohort of men is greater than that for women.”
BackgroundLate consequences of a low peak bone mass
Ribot, C. A., Trémollières, F., & Pouillès, J. M. (1995) · Acta Paediatrica · doi:10.1111/j.1651-2227.1995.tb13857.x · Cited by 31
Mechanical simulation of the human mandible with and without an endosseous implant
Chen, J., Lu, X., Paydar, N. H., Akay, H. U., & Roberts, W. E. (1994) · Medical Engineering & Physics · doi:10.1016/1350-4533(94)90011-6 · Cited by 31
Mineral and matrix contributions to rigidity in fracture healing
Chakkalakal, D. A., Lippiello, L., Wilson, R. F., Shindell, R., & Connolly, J. F. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90297-g · Cited by 31
Numerical Simulation of Mandible Bone Remodeling under Tooth Loading: A Parametric Study
Su, K., Yuan, L., Yang, J., & Du, J. H. (2019) · Scientific Reports · doi:10.1038/s41598-019-51429-w · Cited by 30
Biomimetic chitosan with biocomposite nanomaterials for bone tissue repair and regeneration
Kim, S., Murugan, S. S., Dalavi, P. A., Gupta, S., Anil, S., Seong, G. H., & Venkatesan, J. (2022) · Beilstein Journal of Nanotechnology · doi:10.3762/bjnano.13.92 · Cited by 32
Multiscale Modeling of the Skeletal System
Viceconti, M. (2011) · Cambridge University Press eBooks · doi:10.1017/cbo9781139049627 · Cited by 42
Amini, M., Nazemi, S. M., Lanovaz, J. L., Kontulainen, S. A., Masri, B. A., Wilson, D. R., Szyszkowski, W., & Johnston, J. D. (2015) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2015.05.011 · Cited by 34
Long‐term ovariectomy decreases ovine compact bone viscoelasticity
Les, C. M., Vance, J. L., Christopherson, G. T., Turner, A. S., Divine, G., & Fyhrie, D. P. (2005) · Journal of Orthopaedic Research® · doi:10.1016/j.orthres.2004.12.001 · Cited by 30
Kourtis, L. C., Carter, D. R. P., Kesari, H., & Beaupré, G. S. (2008) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840801930728 · Cited by 31
Self-citationFrazer, L. L., Santschi, E. M., & Fischer, K. J. (2017) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2017.06.019 · Cited by 30
Vogel, D., Klimek, M., Saemann, M., & Bader, R. (2020) · Materials · doi:10.3390/ma13061372 · Cited by 30
“A linear correlation between the HU and apparent density was assumed using the following equation: ρapp (g/cm3) = 0.0007918*HU + 0.4718988 (1) To calculate the Young’s modulus from the apparent density, the following equation based on the equation of Carter and Hayes was used [27]: E (GPa) = 3.79e0.”
MethodInfluentialChatvanitkul, C., & Lertchirakarn, V. (2009) · Journal of Endodontics · doi:10.1016/j.joen.2009.09.026 · Cited by 30
Fracture Stiffness in Callotasis Determined by Dual-Energy X-Ray Absorptiometry Scanning
Tselentakis, G., Owen, P. J., Richardson, J. B., Kuiper, J. H., Haddaway, M. J., Dwyer, J. S. M., & Evans, G. A. (2001) · Journal of Pediatric Orthopaedics B · doi:10.1097/01202412-200107000-00016 · Cited by 31
Bailey, S. B., Grover, D. M., Howell, S. M., & Hull, M. L. (2004) · The American Journal of Sports Medicine · doi:10.1177/0363546503261716 · Cited by 30
Mechanical Properties of Subchondral Cancellous Bone of the Radial Head
Gordon, K., Duck, T. R., King, G. J. W., & Johnson, J. A. (2003) · Journal of Orthopaedic Trauma · doi:10.1097/00005131-200304000-00007 · Cited by 30
Skeletal aging understanding the functional and structural basis of osteoporosis
Marcus, R. (1991) · Trends in Endocrinology and Metabolism · doi:10.1016/1043-2760(91)90040-t · Cited by 36
Shi, Q., Shui, H., Chen, Q., & Li, Z. (2019) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2019.103588 · Cited by 32
Biomechanics of Bone and Age-Related Fractures
Morgan, E. F., & Bouxsein, M. (2008) · Elsevier eBooks · doi:10.1016/b978-0-12-373884-4.00024-0 · Cited by 40
Hydraulic Resistance and Permeability in Human Lumbar Vertebral Bodies
Ochia, R. S., & Ching, R. P. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1503793 · Cited by 29
Axial-shear interaction effects on microdamage in bovine tibial trabecular bone
Wang, X., Guyette, J. P., Liu, X., Roeder, R. K., & Niebur, G. L. (2005) · European Journal of Morphology · doi:10.1080/09243860500095570 · Cited by 34
Shear strength and toughness of trabecular bone are more sensitive to density than damage
Garrison, J. G., Gargac, J. A., & Niebur, G. L. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.09.002 · Cited by 32
“The absence of marrow should not affect the mechanical properties at the strain rates applied here (Carter and Hayes, 1977; Pilcher et al., 2010).”
BackgroundModeling Modulus Reduction in Bovine Trabecular Bone Damaged in Compression
Moore, T. L. A., & Gibson, L. J. (2001) · Journal of Biomechanical Engineering · doi:10.1115/1.1407828 · Cited by 34
Microarchitectural and mechanical characterization of the sickle bone
Green, M., Akinsami, I., Lin, A., Banton, S., Ghosh, S., Chen, B., Platt, M. O., Osunkwo, I., Ofori-Acquah, S. F., Guldberg, R. E., et al. (2015) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2015.04.019 · Cited by 29
Validation of multiple subject-specific finite element models of unicompartmental knee replacement
Tuncer, M., Cobb, J. P., Hansen, U. N., & Amis, A. A. (2013) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2013.03.020 · Cited by 34
Pakdel, A., Fialkov, J. A., & Whyne, C. M. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.03.015 · Cited by 29
“The upper limit of cortical bone's apparent density is 1:8 g/cm(3) (Carter and Hayes, 1977).”
BackgroundMethodFinite element analysis of tibial fractures.
Wong, C., Mikkelsen, P. S., Hansen, L. B., Darvann, T. A., & Gebuhr, P. (2010) · PubMed · Cited by 29
McCarty, C. A., Thomason, J. J., Gordon, K., Burkhart, T. A., Milner, J. S., & Holdsworth, D. W. (2016) · PLoS ONE · doi:10.1371/journal.pone.0159541 · Cited by 32
Influence of Geometry and Depth of Resections on Bone Support for Total Ankle Replacement
Bischoff, J. E., Schon, L. C., & Saltzman, C. L. (2017) · Foot & Ankle International · doi:10.1177/1071100717712508 · Cited by 29
“Various studies have shown a power relationship between HU and mechanical properties (including stiffness and strength) of bone, ~ HU n ( ) , though there is significant variability in the value of n based on the anatomic location and/ or study design.(4,15,16,20) Here, values of n ranging from 1 to 3 were considered,…”
BackgroundMethodEffect of pelvis impact angle on stresses at the femoral neck during falls
Choi, W. J., & Robinovitch, S. N. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.04.015 · Cited by 29
The bone organ system: form and function
Morgan, E. F., & Gerstenfeld, L. C. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-813073-5.00002-2 · Cited by 38
Bone strength and histomorphometry of the distal femur
Nakabayashi, Y., Wevers, H. W., Cooke, T. D. V., & Griffin, M. P. (1994) · The Journal of Arthroplasty · doi:10.1016/0883-5403(94)90086-8 · Cited by 29
Remmler, D., Olson, L. G., Ekstrom, R. E., Duke, D. A., Matamoros, A., Matthews, D., & Ullrich, C. G. (1998) · Medical Engineering & Physics · doi:10.1016/s1350-4533(98)00053-8 · Cited by 29
“Their methods utilize the CT data to derive voxel specific material properties [64] and transfer these values to a spatially equivalent mesh of cubic elements.”
MethodThe Healing of Experimental Fractures by Compression Osteosynthesis: I.Torsional Strength
Paavolainen, P., SLÄTIS, P., Karaharju, E. O., & Holmström, T. (1979) · Acta Orthopaedica Scandinavica · doi:10.3109/17453677908989778 · Cited by 29
A Survey on Bone Fracture Identification Techniques using Quantitative and Learning Based Algorithms
Saranya, A., & Kottursamy, K. (2021) · International Conference on Artificial Intelligence and Smart Energy (ICAIS) · doi:10.1109/icais50930.2021.9395817 · Cited by 29
“The strain rate-density rate-modulus equation is explained [13] which describes the bone density as well as the strain related to bone material combinations and other mechanical properties of yield-strain-strength and ultimate strain-strength [14], which is determined by the relationship of bone…”
BackgroundA computational insight on damage-based constitutive modelling in femur mechanics
Gaziano, P., Falcinelli, C., & Vairo, G. (2022) · European Journal of Mechanics - A/Solids · doi:10.1016/j.euromechsol.2022.104538 · Cited by 28
MECHANICAL EFFECTS OF THE EXTENDED TROCHANTERIC OSTEOTOMY
Noble, A., Branham, D. B., Willis, M. C., Owen, J. R., CRAMER, B. W., Wayne, J. S., & Jiranek, W. A. (2005) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200503000-00007 · Cited by 28
Chen, S.-H., Chiang, M.-C., Lin, J.-F., Lin, S., & Hung, C.-H. (2013) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-14-281 · Cited by 28
“Compared to the normal bone, “osteoporosis” was defined as a decrease of 66% in the elastic modulus for cancellous bone and a decrease of 33% for the cortical bone [24].”
BackgroundKerrigan, J. R., Sánchez‐Molina, D., Neggers, J., Arregui‐Dalmases, C., Velázquez-Ameijide, J., & Crandall, J. R. (2013) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2013.04.027 · Cited by 28
“These elastic moduli could be applied to elastic/elastic–plastic models of bone for response prediction in computational simulations of vehicle crashes with or without the effects of loading-rate sensitivity, which has been described previously in several studies (cf. Carter and Hayes (1977)).”
BackgroundLong-term in vivo response to citric acid-based nanocomposites for orthopaedic tissue engineering
Chung, E. J., Kodali, P., Laskin, W. B., Koh, J. L., & Ameer, G. A. (2011) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-011-4393-5 · Cited by 33
Validation of a new multiscale finite element analysis approach at the distal radius
Johnson, J. E., & Troy, K. L. (2017) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2017.03.005 · Cited by 28
The effect of short-stem humeral component sizing on humeral bone stress
Langohr, G. D. G., Reeves, J. M., Roche, C. P., Faber, K. J., & Johnson, J. A. (2019) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2019.08.018 · Cited by 29
Bone Fatigue and Remodeling in the Development of Stress Fractures
Schaffler, M. B. (2000) · Exercise physiology/CRC series in exercise physiology · doi:10.1201/9781420042191.ch11 · Cited by 32
Three-Dimensional Simulation of Mandibular Distraction Osteogenesis: Mechanobiological Analysis
Reina-Romo, E., Gómez‐Benito, M. J., Sampietro-Fuentes, A., Domínguez, J., & García‐Aznar, J. M. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0166-4 · Cited by 28
Site and Sex Effects on Tibia Structure in Distance Runners and Untrained People
Feldman, S., Capozza, R. F., Mortarino, P., Reina, P. S., Ferretti, J. L., Rittweger, J., & Cointry, G. R. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31824e10b6 · Cited by 45
Mayhew, P. M., Kaptoge, S. K., Loveridge, N., Power, J., Kröger, H., Parker, M. J., & REEVE, J. (2003) · Bone · doi:10.1016/j.bone.2003.11.012 · Cited by 28
Analysis of the effect of using two different strain rates on the acoustic emission in bone
Fischer, R. A., Arms, S. W., Pope, M. H., & Seligson, D. (1986) · Journal of Biomechanics · doi:10.1016/0021-9290(86)90142-9 · Cited by 28
Effect of long-term ovariectomy on bone mechanical properties in young female cynomolgus monkeys
Kasra, M., & Grynpas, M. D. (1994) · Bone · doi:10.1016/8756-3282(94)90281-x · Cited by 33
van Rietbergen, B., Kabel, J., Odgaard, A., & Huiskes, R. (1997) · Springer eBooks · doi:10.1007/978-94-009-1471-1_19 · Cited by 32
Surface remodeling of trabecular bone using a tissue level model
Smith, T. S., Martin, R. B., Hubbard, M., & Bay, B. K. (1997) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100150416 · Cited by 28
“They have used structureproperty relationships similar to those developed by Carter and Hayes (2) from tests on specimens with a volume of approximately 1 X 10’ mm3, whereas the finite element models have elements with domains of 1.”
BackgroundMethodCharacterization of bone quality using computer‐extracted radiographic features
Jiang, C., Giger, M. L., Chinander, M. R., Martell, J. M., Kwak, S. M., & Favus, M. J. (1999) · Medical Physics · doi:10.1118/1.598604 · Cited by 31
Anatomic and Directional Variation in the Mechanical Properties of the Mandibular Condyle in Pigs
Teng, S., & Herring, S. W. (1996) · Journal of Dental Research · doi:10.1177/00220345960750110501 · Cited by 33
Two and three-dimensional morphometric analysis of trabecular bone using X-ray microtomography (µCT)
da Silva, A. M. H., Alves, J. M., da Silva, O. L., & da Silva, N. F. (2014) · Research on Biomedical Engineering · doi:10.1590/rbeb.2014.011 · Cited by 34
“The bone density of cancellous bone was related to strength and was observed a strong positive correlation between the density and the maximum breakdown stress and between density and stiffness (Carter and Hayes, 1977; Ciarelli et al., 1991; Currey, 1969; Rice et al., 1988).”
BackgroundÖhman‐Mägi, C., Zwierzak, I., Baleani, M., & Viceconti, M. (2012) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411912459424 · Cited by 28
Alemayehu, D. B., Masahiro Todoh, A., & Huang, S. (2024) · Journal of Functional Biomaterials · doi:10.3390/jfb15040094 · Cited by 27
“This discovery is consistent with previous research, which has repeatedly established that trabecular bone has a porosity greater than 70% [17,72,73,76–78], highlighting the biomimetic accuracy of our lattice design.”
BackgroundResultBurton, N. J., Perry, M. J., Fitzpatrick, N., & Owen, M. R. (2010) · American Journal of Veterinary Research · doi:10.2460/ajvr.71.1.41 · Cited by 35
Shu, J., Zhang, Y., & Liu, Z. (2019) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2019.03.018 · Cited by 27
Patient-Specific Bone Multiscale Modelling, Fracture Simulation and Risk Analysis—A Survey
de Alcântara, A. C. S., Assis, I., Prada, D., Mehle, K., Schwan, S., Costa‐Paiva, L., Skaf, M. S., Wrobel, L. C., & Sollero, P. (2019) · Materials · doi:10.3390/ma13010106 · Cited by 28
“Relationships proposed by [256,285] showed less accuracy.”
Minimizing specimen length in elastic testing of end-constrained cancellous bone
Lievers, W. B., Waldman, S. D., & Pilkey, A. K. (2009) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2009.02.001 · Cited by 27
Han, S., Medige, J., Faran, K. J., Feng, Z., & Ziv, I. (1997) · Medical Engineering & Physics · doi:10.1016/s1350-4533(97)00028-3 · Cited by 27
Uniform Stress State in Bone Structure With Residual Stress
ADACHI, T., Tanaka, M., & Tomita, Y. (1998) · Journal of Biomechanical Engineering · doi:10.1115/1.2798000 · Cited by 27
Load-bearing capacity of corticocancellous bone grafts in the spine.
Smith, M. D., & CODY, D. D. (1993) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199308000-00010 · Cited by 27
Bhatia, V., Edwards, W. B., & Troy, K. L. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.04.050 · Cited by 29
“25 (Keller et al., 1994) (i) E=2,500 app3 (Carter and Hayes, 1977) (ii) E=6850 app1.”
MethodMechanical variables affecting balloon kyphoplasty outcome – a finite element study
Dabirrahmani, D., Becker, S. T., Hogg, M., Appleyard, R. C., Baroud, G., & Gillies, M. (2011) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2010.522183 · Cited by 26
Lim, K., & Choi, W. J. (2019) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2019.06.002 · Cited by 26
Mouloodi, S., Rahmanpanah, H., Burvill, C. R., Gohery, S., & Davies, H. M. S. (2021) · Mechanics of Advanced Materials and Structures · doi:10.1080/15376494.2020.1864071 · Cited by 29
“In that study power functions were fitted to the data and it was shown that the modulus of elasticity and strength were a power function of wet density with cubic and squared exponents respectively [7].”
BackgroundMethodInfluentialModelling external bone adaptation using evolutionary structural optimisation
Chen, G., Pettet, G. J., Pearcy, M. J., & McElwain, D. L. S. (2006) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-006-0055-9 · Cited by 29
Prochor, P., & Sajewicz, E. (2019) · BioMed Research International · doi:10.1155/2019/6067952 · Cited by 26
Interspecies Comparison of Alveolar Bone Biology, Part I: Morphology and Physiology of Pristine Bone
Pilawski, I., Tulu, U. S., Ticha, P., Schüpbach, P., Traxler, H., Xu, Q., Pan, J., Coyac, B. R., Yuan, X., Tian, Y., et al. (2020) · JDR Clinical & Translational Research · doi:10.1177/2380084420936979 · Cited by 27
“To gain insights into whether the species had equivalent bone strength, we quantified BMD, which is considered a primary determinant of bone strength, as is bone structure (Carter and Hayes 1977).”
BackgroundThe use of a fiber sleeve to improve fracture strength of pulpless teeth with flared root canals
Xiong, Y., Huang, S., Shinno, Y., Furuya, Y., Imazato, S., Fok, A. S. L., & Hayashi, M. (2015) · Dental Materials · doi:10.1016/j.dental.2015.09.005 · Cited by 26
Toward Characterization of Craniofacial Biomechanics
Szwedowski, T. D., Whyne, C. M., & Fialkov, J. A. (2010) · Journal of Craniofacial Surgery · doi:10.1097/scs.0b013e3181c50f64 · Cited by 26
Sinclair, K. D., Farnsworth, R. W., Pham, T. X., Knight, A. N., Bloebaum, R. D., & Skedros, J. G. (2013) · Journal of Human Evolution · doi:10.1016/j.jhevol.2013.01.003 · Cited by 28
“Experimental studies have shown that the mechanical properties of trabecular bone are generally similar in humans and bovines (Carter and Hayes, 1977; Lotz and Hayes, 1990; Keaveny et al., 1994b).”
BackgroundUse of bone compaction in total knee arthroplasty
Channer, M., Glisson, R. R., Seaber, A. V., & Vail, T. P. (1996) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(96)80015-5 · Cited by 27
Huang, H., Tsai, M.-T., Lin, D., Chien, C., & Hsu, J. (2010) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2010.02.011 · Cited by 27
“However, many investigators have proposed different formulae [10,11,15,27–29,34–36] for determining the elastic modulus from the bone density due to the various loading modes employed in experiments (e.”
BackgroundResultWhy fine-wire fixators work: An analysis of pressure distribution at the wire–bone interface
Tim Board, Yang, L., & Saleh, M. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.12.005 · Cited by 26
“The material properties of this foam make it a reasonable model for cancellous bone (Thompson et al., 2003; Li and Aspden, 1997; Carter and Hayes, 1977).”
BackgroundInfluentialLievers, W. B., Petryshyn, A. C., Poljsak, A. S., Waldman, S. D., & Pilkey, A. K. (2010) · Bone · doi:10.1016/j.bone.2010.03.024 · Cited by 26
“Given that Carter and Hayes [21] have demonstrated that cancellous bone is only mildly strain rate sensitive, with an exponent of 0.”
BackgroundTrabecular bone failure at the microstructural level
Müller, R., & van Lenthe, H. (2006) · Current Osteoporosis Reports · doi:10.1007/s11914-006-0007-4 · Cited by 31
“Significant correlations between apparent bone density and various mechanical properties have been demonstrated for large populations using power–law regressions [2,5,6].”
BackgroundParameters affecting the stress distribution around LTI carbon and aluminum oxide dental implants
Cook, S. D., WEINSTEIN, A. M., & Klawitter, J. J. (1982) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820160612 · Cited by 26
Duquette, J. J., Lin, J., Hoffman, A. H., Houde, J. P., Ahmadi, S., & Baran, D. T. (1997) · Calcified Tissue International · doi:10.1007/s002239900211 · Cited by 26
Rho, J. Y., Flaitz, D. J., Swarnakar, V., & Acharya, R. S. (1997) · Bone · doi:10.1016/s8756-3282(97)00022-7 · Cited by 26
Epiphyseal-based designs for tibial plateau components—I. Stress analysis in the frontal plane
Vasu, R., Carter, D. R. P., Schurman, D. J., & Beaupré, G. S. (1986) · Journal of Biomechanics · doi:10.1016/0021-9290(86)90170-3 · Cited by 26
Self-citationSabet, F. A., Jin, O., Korić, S., & Jasiuk, I. (2017) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2941 · Cited by 28
Resonant frequency analysis of dental implants
Rittel, D., Dorogoy, A., Haïat, G., & Shemtov‐Yona, K. (2019) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2019.02.008 · Cited by 25
Tsuang, F.-Y., Li, M.-J., Chu, P., Tsou, N., & Sun, J. (2023) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-023-03556-4 · Cited by 25
“Additive manufactured medical instruments with porous structures provide more flexible design principles by optimizing a design and bring lots of benefits, such as functionally gradient structure for cells to proliferate, lower consumption of materials, and customized strength and stiffness [18, 19].”
BackgroundKemper, A. R., McNally, C., Kennedy, E. A., Manoogian, S. J., & Duma, S. M. (2007) · Cited by 42
Metadata
- Authors
- Carter, D., & Hayes, W.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1977-10
- Volume
- 59
- Issue
- 7
- Pages
- 954-962
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W1901463649
- Semantic Scholar
- cc21d6cd590fb46c2bd9cfd768da63c8012862ee
- Cited by
- 2,001
- References
- 0
- Citations by year
- 2026: 30 · 2025: 31 · 2024: 41 · 2023: 40 · 2022: 60 · 2021: 61 · 2020: 57 · 2019: 66 · 2018: 59 · 2017: 55 · 2016: 55 · 2015: 67 · 2014: 79 · 2013: 68 · 2012: 67
- FWCI
- 18.23
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Bone and Joint Surgery (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Physical Sciences › Engineering › Mechanical Engineering › Cellular and Composite Structures
- Keywords
- trabecular bone, strain rate sensitivity, bone stiffness, energy absorption, marrow, porous structure, apparent density, human bone, bovine bone
- MeSH terms
- Animals, Bone and Bones, Cattle, Humans, Stress, Mechanical, Tensile Strength
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.