The compressive behavior of bone as a two-phase porous structure
The DOI matches its Crossref record.
Abstract
Compression tests of human and bovine trabecular bone specimens with and without marrow in situ were conducted at strain rates of from 0.001 to 10.0 per second. A porous platen above the specimens allowed the escape of marrow during testing. The presence of marrow increased the strength, modulus, and energy absorption of specimens only at the highest strain rate of 10.0 per second. This enhancement of material properties at the highest strain rate was due primarily to the restricted viscous flow of marrow through the platen rather than the flow through the pores of the trabecular bone. In specimens without marrow, the strength was proportional to the square of the apparent density and the modulus was proportional to the cube of the apparent density. Both strength and modulus were approximately proportional to the strain rate raised to the 0.06 power. These power relationships, which were shown to hold for all bone in the skeleton, allow meaningful predictions of bone tissue strength and stiffness based on in vivo density measurements.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The compressive modulus and compressive strength are proportional to the strain rate raised to the power of 0.06 (100, 101).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [101]
Citations
Cited by
Items 501–600 of 1,002
Fayyazbakhsh, F., Solati‐Hashjin, M., Keshtkar, A., Shokrgozar, M. A., Dehghan, M. M., & Larijani, B. A. (2017) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2017.07.004 · Cited by 63
Design and testing of external fixator bone screws
Evans, M., Spencer, M., Wang, Q., White, S. H., & Cunningham, J. L. (1990) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(90)90054-q · Cited by 60
Poroelastic properties of bovine vertebral trabecular bone
Lim, T. H., & Hong, J. H. (2000) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100180421 · Cited by 60
Giesen, E. B. W., Ding, M. L., Dalstra, M., & van Eijden, T. M. G. J. (2003) · Clinical Biomechanics · doi:10.1016/s0268-0033(03)00018-4 · Cited by 60
“This was not surprising due to the lower density in the edentate group and the established relationship between apparent density and mechanical parameters (Carter and Hayes, 1977).”
BackgroundTanne, K., Miyasaka, J., Yamagata, Y., Sachdeva, R., Tsutsumi, S., & Sakuda, M. (1988) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(88)90006-4 · Cited by 60
Harrigan, T. P., & Hamilton, J. J. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90088-i · Cited by 60
“The relationship between density and elastic modulus used is an exponential one, following Carter and Hayes (1977). Other relationships have been proposed, but the representation of experimental data on cancellous-bone modulus vs density has not been substantially improved over Carter and Hayes by curve-fits which do…”
BackgroundMethodInfluentialAbram, A. C., Keller, T. S., & Spengler, D. M. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90284-9 · Cited by 60
“, 1980) and reduced fatigue strength (Carter and Hayes, 1977).”
The Production of Porous Hydroxyapatite Scaffolds with Graded Porosity by Sequential Freeze-Casting
Lee, H., Jang, T., Song, J., Kim, H., & Jung, H. (2017) · Materials · doi:10.3390/ma10040367 · Cited by 68
“By controlling the Sden/Spor ratios of the scaffolds, the structural and compressive features can be customized to match those of the surrounding bones at the implant site [18,42].”
BackgroundDawson, J. M., Khmelniker, B. V., & McAndrew, M. P. (1999) · Accident Analysis & Prevention · doi:10.1016/s0001-4575(98)00052-9 · Cited by 59
Time-dependent properties of human root dentin
Jantarat, J., Palamara, J. E. A., Lindner, C., & Messer, H. H. (2002) · Dental Materials · doi:10.1016/s0109-5641(01)00074-4 · Cited by 59
Bone Mineral Assay: Its Relation to the Mechanical Strength of Cancellous Bone
Hvid, I., Jensen, N. C., Bünger, C. E., Sølund, K., & Djurhuus, J. C. (1985) · Engineering in Medicine · doi:10.1243/emed_jour_1985_014_016_02 · Cited by 59
Aldieri, A., Curreli, C., Szyszko, J. A., Mattina, A. A. L., & Viceconti, M. (2023) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2023.107727 · Cited by 60
Soares, P. V., Machado, A., Zéola, L. F., Souza, P., Galvão, A., Montes, T., Pereira, A. G., Reis, B., Coleman, T., & Grippo, J. O. (2014) · Australian Dental Journal · doi:10.1111/adj.12233 · Cited by 58
Biomechanics Modeling of the Musculoskeletal Apparatus: Status and Key Issues
Viceconti, M., Testi, D., Taddei, F., Martelli, S., Clapworthy, G., & Jan, S. V. S. (2006) · Proceedings of the IEEE · doi:10.1109/jproc.2006.871769 · Cited by 58
“from the CT measured density [69], [75], [76].”
BackgroundDual-Energy X-Ray Absorptiometry in Predicting Mechanical Characteristics of Rat Femur
Järvinen, T. L. N., Sievänen, H. T., Kannus, P., & Järvinen, M. (1998) · Bone · doi:10.1016/s8756-3282(98)00025-8 · Cited by 58
Age-Related Changes of Noncalcified Collagen in Human Cortical Bone
Wang, X., Li, X., Shen, X., & Agrawal, C. M. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1623488 · Cited by 58
Brodland, G. W., CHEN, D., & Veldhuis, J. (2005) · International Journal of Plasticity · doi:10.1016/j.ijplas.2005.05.002 · Cited by 60
Trabecular bone structure and strength - remodelling and repair.
Mosekilde, L., Ebbesen, E. N., Tornvig, L., & Thomsen, J. S. (2000) · PubMed · Cited by 76
Bone remodeling and structural optimization
Harrigan, T. P., & Hamilton, J. J. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90008-6 · Cited by 58
Biomechanics of Bone and Tissue: A Review of Material Properties and Failure Characteristics
Viano, D. C. (1986) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/861923 · Cited by 62
Sex Differences in Parameters of Bone Strength in New Recruits: Beyond Bone Density
Evans, R. K., Negus, C. H., Antczak, A. J., Yanovich, R., Israeli, E., & Moran, D. S. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181893cb7 · Cited by 57
Peña, E., del Palomar, A. P., Calvo, B., Martínez, M. Á., & Doblaré, M. (2007) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-006-9001-3 · Cited by 64
Helgason, B., Gilchrist, S. E., Ariza, O., Chak, J. D., Guoyan Zheng, A., Widmer, R. P., Ferguson, S. J., Guy, P., & Cripton, P. A. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.02.019 · Cited by 57
Enns-Bray, W. S., Bahaloo, H., Fleps, I., Ariza, O., Gilchrist, S. E., Widmer, R. P., Guy, P., Pálsson, H., Ferguson, S. J., Cripton, P. A., et al. (2017) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2017.10.033 · Cited by 57
Mitsuishi, M., Cao, J., Bártolo, P., Friedrich, D., Shih, A. J., Rajurkar, K. P., Sugita, N., & Harada, K. (2013) · CIRP Annals · doi:10.1016/j.cirp.2013.05.001 · Cited by 71
Finite element stress analysis on the effect of splinting in fixed partial dentures
Yang, H.-S., Lang, L. A., & Felton, D. A. (1999) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(99)70113-7 · Cited by 57
Mitton, D., Rumelhart, C., Hans, D., & Meunier, P. J. (1997) · Medical Engineering & Physics · doi:10.1016/s1350-4533(97)00001-5 · Cited by 57
Biaxial Failure Behavior of Bovine Tibial Trabecular Bone
Niebur, G. L., Feldstein, M. J., & Keaveny, T. M. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1517566 · Cited by 67
Kohles, S. S., & Roberts, J. B. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1503374 · Cited by 62
Manning, P. L., Margetts, L., Johnson, M. R., Withers, P. J., Sellers, W. I., Falkingham, P. L., Mummery, P. M., Barrett, P. M., & Raymont, D. R. (2009) · The Anatomical Record · doi:10.1002/ar.20986 · Cited by 57
A Biomechanical Evaluation of Three Forms of Internal Fixation Used in Ankle Arthrodesis
Dohm, M. P., Benjamin, J. B., Harrison, J., & Szivek, J. A. (1994) · Foot & Ankle International · doi:10.1177/107110079401500603 · Cited by 57
Bone mineral density in the proximal femur and hip fracture type in the elderly
Nakamura, N., KYO, T., Takaoka, K., Ohzono, K., & Ono, K. (1992) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650070705 · Cited by 63
Multiaxial Structure-Property Relations in Trabecular Bone
Snyder, B. D., & Hayes, W. C. (1990) · Springer eBooks · doi:10.1007/978-1-4612-3450-0_2 · Cited by 61
Self-citationSpecially adapted interactive tools for an improved 3D-segmentation of the spine
Kaminsky, J., Klinge, P. M., Rodt, T., Bokemeyer, M., Luedemann, W. O., & Samii, M. (2004) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2003.12.001 · Cited by 56
Predicting the Strength of Femoral Shafts with and without Metastatic Lesions
Keyak, J. H., Kaneko, T. S., Rossi, S. A., Pejcic, M. R., Tehranzadeh, J., & Skinner, H. B. (2005) · Clinical Orthopaedics and Related Research · doi:10.1097/01.blo.0000174736.50964.3b · Cited by 56
“Whether these results are applicable to impact loading is not known, although the mechanical properties of bone without tumors only weakly depend on strain rate.(4) Using four-point bending also simplified the models because the maximum normal stress tended to be aligned with the longitudinal axis of the bone.”
BackgroundMatsuura, Y., Giambini, H., Ogawa, Y., Fang, Z., Thoreson, A. R., Yaszemski, M. J., Lu, L., & An, K. (2014) · Spine · doi:10.1097/brs.0000000000000540 · Cited by 56
Shimko, D. A., & Nauman, E. A. (2006) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.30605 · Cited by 69
Non-linear approach in visco-hyperelastic constitutive modelling of polyurethane nanocomposite
Pawlikowski, M. (2013) · Mechanics of Time-Dependent Materials · doi:10.1007/s11043-013-9208-2 · Cited by 58
“The constraint (i) is a fundamental one for existence and uniqueness of the solution in the boundary value analysis (Carter and Hayes 1977; Linde 1994).”
BackgroundSchoell, S. L., Weaver, A. A., Urban, J. E., Jones, D. A., Stitzel, J. D., Hwang, E., Reed, M. P., Rupp, J. D., & Hu, J. (2015) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/2015-22-0014 · Cited by 61
A Review of Head Injury and Finite Element Head Models
Tse, K. M., Lim, S. P., Tan, V. B. C., & Lee, H. P. (2015) · Journal of Engineering and Technology · Cited by 83
Fat and bone: the multiperspective analysis of a close relationship
Gómez, M. P. A., Benavent, C. A., Simoni, P., Aparisi, F., Guglielmi, G., & Bazzocchi, A. (2020) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims.2020.01.11 · Cited by 57
“It is important to mention that most studies support the open model (44).”
ResultBiomechanical Properties of Bone
Ferretti, J. L. (1998) · Springer eBooks · doi:10.1007/978-3-642-80440-3_8 · Cited by 69
Keaveny, T. M., & Bartel, D. L. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90087-u · Cited by 56
Brock, S. L., & Ruff, C. B. (1988) · American Journal of Physical Anthropology · doi:10.1002/ajpa.1330750113 · Cited by 56
Polk, J. D., Blumenfeld, J., & Ahluwalia, D. (2008) · The Anatomical Record · doi:10.1002/ar.20653 · Cited by 57
“Increasing bone density confers several advantages, such as increased strength in compression, compressive modulus, fatigue life, resistance to crack initiation, and tensile strength (Carter and Hayes, 1977; Wright and Hayes, 1977; Wall et al., 1979; Currey, 1988, 2002; Rice et al., 1988).”
BackgroundTaylor, M., Bryan, R., & Galloway, F. (2012) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2530 · Cited by 55
“The relationships between greyscale (Hounsfield units) and apparent density [42,43], and between apparent density and modulus [44] are well established.”
BackgroundDevelopment of the fetal ilium – challenging concepts of bipedality
Cunningham, C. A., & Black, S. M. (2008) · Journal of Anatomy · doi:10.1111/j.1469-7580.2008.01005.x · Cited by 59
“…investigation of trabecular bone architecture with the aim of elucidating its mechanical role within the skeletal system (Evans, 1973; Lanyon, 1974; Carter & Hayes, 1977; Gibson, 1985; Goldstein, 1987; Frost, 1990; Ciarelli et al. 1991; Biewener et al. 1996; Keaveny et al. 2001; Jee, 2005; Liu et…”
BackgroundGanbat, D., Kim, Y. H., Kim, K., Jin, Y. J., & Park, W. M. (2015) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-015-0752-3 · Cited by 55
Investigation of Conditions That Affect Neck Compression-Flexion Injuries Using Numerical Techniques
Halldin, P., Brolin, K., Kleiven, S., von Holst, H., Jakobsson, L., & Palmertz, C. (2000) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/2000-01-sc10 · Cited by 55
A morphological model of vertebral trabecular bone
Kim, H. S., & Al-Hassani, S. T. S. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00053-2 · Cited by 61
“The compositions and the densities of compact and trabecular bone were known to be almost the same (Gong et al., 1964; Galante et al., 1970; Carter and Hayes, 1977; Carter and Spengler, 1978; Gibson and Ashby, 1997).”
BackgroundKatsumata, T., Nakamura, T., Ohnishi, H., & Sakurama, T. (1995) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650100613 · Cited by 55
Measurement of the density of trabecular bone
Sharp, D. J., Tanner, K. E., & Bonfield, W. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90032-x · Cited by 55
Density and Temperature Effects on Some Mechanical Properties of Cancellous Bone
Brear, K., Currey, J. D., Raines, S. A., & Smith, K. (1988) · Engineering in Medicine · doi:10.1243/emed_jour_1988_017_043_02 · Cited by 55
A longitudinal Raman microspectroscopic study of osteoporosis induced by spinal cord injury
Shen, J., Li, F., Yang, J., Shen, A., & Hu, J. (2009) · Osteoporosis International · doi:10.1007/s00198-009-0949-3 · Cited by 54
Karasuyama, K., Yamamoto, T., Motomura, G., Sonoda, K., Kubo, Y., & Iwamoto, Y. (2015) · Bone · doi:10.1016/j.bone.2015.09.009 · Cited by 54
“For trabecular bone, Young's modulus was determined using Carter's equation [22].”
MethodComposite Implant for Bone Replacement
Kelsey, D. J., Springer, G. Ś., & Goodman, S. B. (1997) · Journal of Composite Materials · doi:10.1177/002199839703101603 · Cited by 54
New QCT Analysis Approach Shows the Importance of Fall Orientation on Femoral Neck Strength
Carpenter, R. D., Beaupré, G. S., Lang, T. F., Orwoll, E. S., & Carter, D. R. (2005) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.050510 · Cited by 52
“However, if bone fails in tension and the tensile load is not removed, the bone can no longer remain intact.((41)) Thus, it is important to account for the relative magnitudes of the”
BackgroundSelf-citationBevill, G. R., Easley, S. K., & Keaveny, T. M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.05.008 · Cited by 54
“These properties are typically obtained from experimental testing (Carter and Hayes, 1977) or finite element modeling (Homminga et al., 2003; Van Rietbergen et al., 1995) of excised specimens of trabecular bone.”
BackgroundStemmed femoral knee prostheses: Effects of prosthetic design and fixation on bone loss
van Lenthe, H., Willems, M. M. M., Verdonschot, N. J. J., Malefijt, M. C. D. W., & Huiskes, R. (2002) · Acta Orthopaedica Scandinavica · doi:10.3109/17453670209178027 · Cited by 54
“Young’s modulus of the bone elements was estimated from their apparent bone densities ( r app ) as (Carter and Hayes, 1977): with r app in g/cm 3 .”
MethodNondestructive determination of iliac crest cancellous bone strength by pQCT
Ebbesen, E. N., Thomsen, J. S., & Mosekilde, L. (1997) · Bone · doi:10.1016/s8756-3282(97)00196-8 · Cited by 56
Static and dynamic mechanical properties of cattle horns
Li, B., Zhao, H., & Feng, X. (2010) · Materials Science and Engineering C · doi:10.1016/j.msec.2010.08.016 · Cited by 55
Guillén-Girón, T., Zhang, Q.-H., Tozzi, G., Ohrndorf, A., Christ, H., & Tong, J. (2011) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2011.05.015 · Cited by 53
Chung, E. J., Sugimoto, M. J., & Ameer, G. A. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.07.001 · Cited by 56
A Review on Recent Advances in the Constitutive Modeling of Bone Tissue
Pahr, D. H., & Reisinger, A. (2020) · Current Osteoporosis Reports · doi:10.1007/s11914-020-00631-1 · Cited by 59
Skedros, J. G., Sorenson, S. M., & Jenson, N. H. (2007) · Cells Tissues Organs · doi:10.1159/000102176 · Cited by 56
“Biomechanical Considerations of Secondary Osteon Morphology Cells Tissues Organs 2007;185:285–307 289 strain mode [Carter and Hayes, 1977a; Boyce et al., 1998; Reilly and Currey, 1999; Akkus et al., 2003; George and Vashishth, 2005].”
InfluentialAn interactive multiblock approach to meshing the spine
Kallemeyn, N. A., Tadepalli, S. C., Shivanna, K. H., & Grosland, N. M. (2009) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2009.03.005 · Cited by 53
“[56] D.”
MethodRapperport, D. J., Carter, D. R. P., & Schurman, D. J. (1987) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100050410 · Cited by 53
Self-citationCyganik, Ł., Binkowski, M., Kokot, G., Rusin, T., Popik, P., Bolechała, F., Nowak, R., Wróbel, Z., & John, A. (2014) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2014.04.011 · Cited by 57
“…0.0368 819.08 20BII Ciarelli et al. (2000) 0.22 0.201 8.64 0.2 0.182 9.00 0.0068 0.0025 63.63 Keller (1994) 0.18 18.18 0.161 19.50 0.0018 74.13 Carter and Hayes (1977) 0.16 27.27 0.141 29.50 0.0011 84.53 Kaneko et al. (2004) 0.173 21.36 0.153 23.50 0.0015 77.75 j o u r n a l o f t h e m e c h…”
BackgroundMethodInfluentialAl‐Sukhun, J., Kelleway, J., & Helenius, M. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30894 · Cited by 52
Perillo‐Marcone, A., Alonso-Vázquez, A., & Taylor, M. (2003) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/1025584031000064470 · Cited by 61
“In this study, the equation reported by Carter and Hayes [11] was found to be the most suitable for cortical bone, whereas for trabecular bone, the equation reported by Linde et al. [12] was considered more accurate, as it was generated from experimental tests performed on specimens obtained from proximal tibiae.”
ResultBrown, T. D., Baker, K., & Brand, R. A. (1992) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100100110 · Cited by 52
Donnelly, E. L., Williams, R. M., Downs, S. A., Dickinson, M., Baker, S. P., & van der Meulen, M. C. H. (2006) · Journal of materials research/Pratt's guide to venture capital sources · doi:10.1557/jmr.2006.0259 · Cited by 59
Formica, C., Loro, M. L., Gilsanz, V., & Seeman, E. (1995) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650101011 · Cited by 52
A finite element model for evaluation of tibial prosthesis-bone interface in total knee replacement
Rakotomanana, L. R., Leyvraz, P. F., Curnier, A., Heegaard, J. H., & Rubin, P. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90055-6 · Cited by 52
Nakamura, T., Kurokawa, T., & Orimo, H. (1989) · Bone · doi:10.1016/8756-3282(89)90009-4 · Cited by 54
Feldmann, A., Ansó, J., Bell, B. J., Williamson, T., Gerber, K., Gerber, N., Rohrbach, H., Weber, S., & Zysset, P. K. (2015) · Annals of Biomedical Engineering · doi:10.1007/s10439-015-1450-0 · Cited by 51
Mechanical properties of OI type III bone tissue measured by nanoindentation
Fan, Z., Smith, P. A., Eckstein, E. C., & Harris, G. F. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30713 · Cited by 58
Fritsch, A., Hellmich, C., & Young, P. G. (2013) · Journal of Applied Mechanics · doi:10.1115/1.4007922 · Cited by 60
Stress relaxation behaviour of trabecular bone specimens
Deligianni, D. D., Maris, A., & Missirlis, Y. F. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90196-1 · Cited by 51
The effect of fracture and fracture fixation on ultrasonic velocity and attenuation
Saulgozis, J., Pontaga, I., Lowet, G., & der Perre, G. V. (1996) · Physiological Measurement · doi:10.1088/0967-3334/17/3/006 · Cited by 51
Antonacci, M. D., Hanson, D. S., LeBlanc, A., & Heggeness, M. H. (1997) · Spine · doi:10.1097/00007632-199710150-00014 · Cited by 58
Frich, L. H., Odgaard, A., & Dalstra, M. (1998) · Journal of Shoulder and Elbow Surgery · doi:10.1016/s1058-2746(98)90023-4 · Cited by 50
Mechanical properties of cancellous bone of the distal humerus
Dunham, C. E., Takaki, S. E., Johnson, J. A., & Dunning, C. E. (2005) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2005.05.014 · Cited by 55
“cancellous bone (Carter and Hayes, 1977; Schoenfeld et al., 1974).”
Vella, J. B., Trombetta, R. P., Hoffman, M. D., Inzana, J. A., Awad, H. A., & Benoit, D. S. W. (2017) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.36270 · Cited by 51
A bibliometric analysis of classic publications in web of science category of orthopedics
Li, Y., Xu, G., Long, X., & Ho, Y. (2019) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-019-1247-1 · Cited by 53
Adaptation Models of Anisotropic Bone
Terrier, A., Rakotomanana, L. R., RAMANIRAKA, A. N., & Leyvraz, P. F. (1997) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/01495739708936694 · Cited by 56
Bone remodeling in a new biomimetic polymer‐composite hip stem
Bougherara, H., Bureau, M., & Yahia, L. (2009) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32346 · Cited by 50
Martín, D. E. A., Severns, A. E., & Kabo, J. M. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.009 · Cited by 50
Tanne, K., Tanaka, E. I., & Sakuda, M. (1996) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/s0889-5406(96)70056-2 · Cited by 50
Tanaka, E. I., Sasaki, A., TAHMINA, K., Yamaguchi, K., Mori, Y., & Tanne, K. (2001) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.2001.tb01699.x · Cited by 51
Computer aided stress analysis of long bones utilizing computed tomography
Marom, S. A., & Linden, M. J. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90294-d · Cited by 50
Characterization of titanium ceramic composite for bone implants applications
Shanmuganantha, L., Khan, M. U. A., Sulong, A. B., Ramli, M. I., Baharudin, A., Ariffin, M. H. M., Razak, S. I. A., & Ng, M. H. (2022) · Ceramics International · doi:10.1016/j.ceramint.2022.04.140 · Cited by 49
Ultrasonic determination of the elastic modulus of human cortical bone
Hunt, K. D., O’Loughlin, V. D., Fitting, D. W., & Adler, L. (1998) · Medical & Biological Engineering & Computing · doi:10.1007/bf02522857 · Cited by 54
An optimal control procedure for bone adaptation under mechanical stimulus
Andreaus, U., Colloca, M., & Iacoviello, D. (2012) · Control Engineering Practice · doi:10.1016/j.conengprac.2012.02.002 · Cited by 51
Remodeling and growth of living tissue: a multiphase theory
Ricken, T., & Bluhm, J. (2009) · Archive of Applied Mechanics · doi:10.1007/s00419-009-0383-1 · Cited by 49
“Carter and Hayes [14] identified the material parameter n in (29) from in situ experiments of human and bovine trabecular bone specimens with and without marrow to a value of n = 3, see also Nackenhorst [25].”
BackgroundMorgan, E. F., Barnes, G. B., & Einhorn, T. A. (2013) · Elsevier eBooks · doi:10.1016/b978-0-12-415853-5.00001-7 · Cited by 58
Cements as bone repair materials
Ginebra, M., & Montúfar, E. B. (2019) · Elsevier eBooks · doi:10.1016/b978-0-08-102451-5.00009-3 · Cited by 49
Design Optimization of Cementless Femoral Hip Prostheses Using Finite Element Analysis
Kowalczyk, P. (2001) · Journal of Biomechanical Engineering · doi:10.1115/1.1392311 · Cited by 53
Stress-related molar responses to the transpalatal arch: A finite element analysis
Bobak, V., Christiansen, R. L., Hollister, S. J., & Kohn, D. H. (1997) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/s0889-5406(97)90100-1 · Cited by 49
Prediction of strength of cortical bone in vitro by microcomputed tomography
Wachter, N. J., Augat, P., Krischak, G. D., Sarkar, M. R., Mentzel, M., Kinzl, L., & Claes, L. (2001) · Clinical Biomechanics · doi:10.1016/s0268-0033(00)00092-9 · Cited by 42
Metadata
- Authors
- Carter, D., & Hayes, W.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1977-10
- Volume
- 59
- Issue
- 7
- Pages
- 954-962
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W1901463649
- Semantic Scholar
- cc21d6cd590fb46c2bd9cfd768da63c8012862ee
- Cited by
- 2,001
- References
- 0
- Citations by year
- 2026: 30 · 2025: 31 · 2024: 41 · 2023: 40 · 2022: 60 · 2021: 61 · 2020: 57 · 2019: 66 · 2018: 59 · 2017: 55 · 2016: 55 · 2015: 67 · 2014: 79 · 2013: 68 · 2012: 67
- FWCI
- 18.23
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Bone and Joint Surgery (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Physical Sciences › Engineering › Mechanical Engineering › Cellular and Composite Structures
- Keywords
- trabecular bone, strain rate sensitivity, bone stiffness, energy absorption, marrow, porous structure, apparent density, human bone, bovine bone
- MeSH terms
- Animals, Bone and Bones, Cattle, Humans, Stress, Mechanical, Tensile Strength
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.