The DOI matches its Crossref record; 77 of the 77 references it cites were found in a registry or an index.
Myoelectric control of prosthetic hands: state-of-the-art review
Open accessAbstract
Myoelectric signals (MES) have been used in various applications, in particular, for identification of user intention to potentially control assistive devices for amputees, orthotic devices, and exoskeleton in order to augment capability of the user. MES are also used to estimate force and, hence, torque to actuate the assistive device. The application of MES is not limited to assistive devices, and they also find potential applications in teleoperation of robots, haptic devices, virtual reality, and so on. The myoelectric control-based prosthetic hand aids to restore activities of daily living of amputees in order to improve the self-esteem of the user. All myoelectric control-based prosthetic hands may not have similar operations and exhibit variation in sensing input, deciphering the signals, and actuating prosthetic hand. Researchers are focusing on improving the functionality of prosthetic hand in order to suit the user requirement with the different operating features. The myoelectric control differs in operation to accommodate various external factors. This article reviews the state of the art of myoelectric prosthetic hand, giving description of each control strategy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
A wavelet-based continuous classification scheme for multifunction myoelectric control
Englehart, K., Hudgin, B., & Parker, P. A. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914793 · Cited by 697
On the Shared Control of an EMG-Controlled Prosthetic Hand: Analysis of User–Prosthesis Interaction
Cipriani, C., Zaccone, F., Micera, S., & Carrozza, M. C. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2007.910708 · Cited by 453
The optimal controller delay for myoelectric prostheses
Farrell, T. R., & Weir, R. F. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891391 · Cited by 438
A heuristic fuzzy logic approach to EMG pattern recognition for multifunctional prosthesis control
Ajiboye, A. B., & Weir, R. F. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847357 · Cited by 415
Linear and Nonlinear Regression Techniques for Simultaneous and Proportional Myoelectric Control
Hahne, J. M., Biebmann, F., Jiang, N., Rehbaum, H., Farina, D., Meinecke, F. C., Muller, K.-R., & Parra, L. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305520 · Cited by 365
Functional Separation of EMG Signals via ARMA Identification Methods for Prosthesis Control Purposes
Graupe, D., & Cline, W. K. (1975) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1975.5408479 · Cited by 354
Chu, J.-U., Moon, I., & Mun, M.-S. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.883695 · Cited by 352
Continuous Myoelectric Control for Powered Prostheses Using Hidden Markov Models
Chan, A. D. C., & Englehart, K. B. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.836492 · Cited by 343
Classification of Simultaneous Movements Using Surface EMG Pattern Recognition
Young, A. J., Smith, L. H., Rouse, E. J., & Hargrove, L. J. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2232293 · Cited by 320
Chu, J.-U., Moon, I., Lee, Y.-J., Kim, S.-K., & Mun, M.-S. (2007) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2007.897262 · Cited by 299
Muceli, S., & Farina, D. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2178039 · Cited by 285
Implantable Myoelectric Sensors (IMESs) for Intramuscular Electromyogram Recording
Weir, R. F., Troyk, P. R., DeMichele, G. A., Kerns, D. A., Schorsch, J. F., & Maas, H. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005942 · Cited by 266
Lucas, M.-F., Gaufriau, A., Pascual, S., Doncarli, C., & Farina, D. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.09.002 · Cited by 253
Myoelectric teleoperation of a complex robotic hand
Farry, K. A., Walker, I. D., & Baraniuk, R. G. (1996) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.538982 · Cited by 248
EMG Pattern Analysis and Classification for a Prosthetic Arm
Saridis, G. N., & Gootee, T. P. (1982) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1982.324954 · Cited by 236
The application of neural networks to myoelectric signal analysis: a preliminary study
Kelly, M. F., Parker, P. A., & Scott, R. N. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.52324 · Cited by 221
Hargrove, L. J., Li, G., Englehart, K. B., & Hudgins, B. S. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2008171 · Cited by 211
A fuzzy clustering neural network architecture for multifunction upper-limb prosthesis
Karlik, B., Tokhi, M. O., & Alci, M. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.818469 · Cited by 198
Duan, F., Dai, L., Chang, W., Chen, Z., Zhu, C., & Li, W. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2497212 · Cited by 193
Upper Extremity Limb Function Discrimination Using EMG Signal Analysis
Doerschuk, P. C., Gustafon, D. E., & Willsky, A. S. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325162 · Cited by 179
Muceli, S., Jiang, N., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2282898 · Cited by 172
Towards the Control of Individual Fingers of a Prosthetic Hand Using Surface EMG Signals
Tenore, F. V., Ramos‐Murguialday, A., Fahmy, A., Acharya, S., Etienne‐Cummings, R., & Thakor, N. V. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353752 · Cited by 154
Graupe, D., Magnussen, J., & Beex, A. A. L. (1978) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1978.1101783 · Cited by 154
Myoelectric Control Development Toolbox
Chan, A. D. C., & Green, G. C. (2007) · CMBES Proceedings · Cited by 152
Classification of EMG Signals Using PCA and FFT
Güler, N. F., & Koçer, S. (2005) · Journal of Medical Systems · doi:10.1007/s10916-005-5184-7 · Cited by 146
Classification of finger activation for use in a robotic prosthesis arm
Dori Peleg, A., Braiman, E., Yom‐Tov, E., & Inbar, G. F. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806831 · Cited by 126
MARCUS: a two degree of freedom hand prosthesis with hierarchical grip control
Kyberd, P., Holland, O. E., Chappell, P. H., Smith, S., Tregidgo, R., Bagwell, P. J., & Snaith, M. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.372895 · Cited by 121
Kang, W.-J., Shiu, J.-R., Cheng, C., Lai, J., Tsao, H., & Kuo, T. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.398638 · Cited by 117
Smith, R. J., Tenore, F. V., Huberdeau, D. M., Etienne‐Cummings, R., & Thakor, N. V. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649124 · Cited by 114
A real-time EMG pattern recognition method for virtual myoelectric hand control
Xing, K., Yang, P., Huang, J., Wang, Y., & Zhu, Q. (2014) · Neurocomputing · doi:10.1016/j.neucom.2013.12.010 · Cited by 113
Temporal vs. spectral approach to feature extraction from prehensile EMG signals
Du, S., & Vuskovic, M. I. (2005) · doi:10.1109/iri.2004.1431485 · Cited by 111
Orthogonal Fuzzy Neighborhood Discriminant Analysis for Multifunction Myoelectric Hand Control
Khushaba, R. N., Al-Ani, A., & Al-Jumaily, A. A. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2039480 · Cited by 110
The control of a prosthetic arm by EMG pattern recognition
Lee, S., & Saridis, G. N. (1984) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1984.1103521 · Cited by 109
Neural Networks for Online Classification of Hand and Finger Movements Using Surface EMG signals
Tsenov, G. T., Zeghbib, A., Palis, F., Shoylev, N., & Mladenov, V. (2006) · Seminar on Neural Network Applications in Electrical Engineering (NEUREL) · doi:10.1109/neurel.2006.341203 · Cited by 105
GA-based Feature Subset Selection for Myoelectric Classification
Oskoei, M. A., & Hu, H. (2006) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2006.340145 · Cited by 100
Wurth, S. M., & Hargrove, L. J. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-91 · Cited by 100
Short Time Fourier Analysis of the Electromyogram: Fast Movements and Constant Contraction
Hannaford, B., & Lehman, S. L. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325697 · Cited by 88
A Low-Cost Real-Time Research Platform for EMG Pattern Recognition-Based Prosthetic Hand
Geethanjali, P., & Ray, K. K. (2014) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2014.2360119 · Cited by 86
Self-citationLi, D., Witold Pedrycz, C., & Pizzi, N. J. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.848377 · Cited by 76
Intention detection using a neuro-fuzzy EMG classifier
Hussein, S. E., & Granat, M. H. (2002) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2002.1175148 · Cited by 73
Chang, G.-C., Kang, W.-J., Luh, J.-J., Cheng, C., Lai, J., Chen, J. J., & Kuo, T. (1996) · Medical Engineering & Physics · doi:10.1016/1350-4533(96)00006-9 · Cited by 72
Levenberg-Marquardt Based Neural Network Control for a Five-fingered Prosthetic Hand
Zhao, J., Xie, Z., Jiang, L. W., Cai, H., Liu, H., & Hirzinger, G. (2006) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2005.1570810 · Cited by 70
A Method of Recognizing Finger Motion Using Wavelet Transform of Surface EMG Signal
Jiang, M., Wang, R. C., Wang, J., et al. (2005) · doi:10.1109/iembs.2005.1617020 · Cited by 69
(1998) · Library and Archives Canada (Government of Canada) · Cited by 68
Huang, H., Liu, Y., Liu, L.-W., & Wong, C.-S. (2004) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2003.1241803 · Cited by 67
Hartmann, C., Dosen, S., Amsuess, S., & Farina, D. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2357175 · Cited by 64
Yang, D., Zhao, J., Gu, Y., Jiang, L., & Liu, H. (2009) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2009.5354544 · Cited by 60
Pattern classification of time-series EMG signals using neural networks
Tsuji, T., Fukuda, O., Kaneko, M., et al. (2000) · International Journal of Adaptive Control and Signal Processing · doi:10.1002/1099-1115(200012)14:8<829::aid-acs623>3.0.co;2-l · Cited by 58
Neuro-Fuzzy Surface EMG Pattern Recognition For Multifunctional Hand Prosthesis Control
Khezri, M., Jahed, M., & Sadati, N. (2007) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2007.4374610 · Cited by 50
Enhanced EMG signal processing for simultaneous and proportional myoelectric control
Nielsen, J. L. G., Holmgaard, S., Jiang, N., Englehart, K. B., Farina, D., & Parker, P. K. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5332745 · Cited by 50
EMG pattern classification using spectral estimation and neural network
Jung, K. K., Kim, J. W., Lee, H. K., Chung, S. B., & Eom, K. H. (2007) · SICE Annual Conference (SICE) · doi:10.1109/sice.2007.4421150 · Cited by 48
Rehbaum, H., Jiang, N., Paredes, L. P., et al. (2012) · doi:10.1109/embc.2012.6346187 · Cited by 44
Kiatpanichagij, K., & Afzulpurkar, N. (2009) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2009.02.004 · Cited by 41
On automatic identification of upper-limb movements using small-sized training sets of EMG signals
Micera, S., Sabatini, A. M., & Dario, P. (2000) · Medical Engineering & Physics · doi:10.1016/s1350-4533(00)00069-2 · Cited by 40
Segil, J. L., & Weir, R. F. F. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2260172 · Cited by 40
Signal-dependent wavelets for electromyogram classification
Maitrot, A., Lucas, M. F., Doncarli, C., & Farina, D. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344730 · Cited by 39
Arvetti, M., Gini, G. C., & Folgheraiter, M. (2007) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428476 · Cited by 39
THE BIO-ELECTRICALLY CONTROLLED PROSTHESIS
Popov, B. (1965) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.47b3.421 · Cited by 38
Muscle substitutes and myo-electric control
Bottomley, A. H., Wilson, A. B. K., & Nightingale, A. (1963) · Radio and Electronic Engineer · doi:10.1049/ree.1963.0169 · Cited by 33
EMG Signal Classification for Myoelectric Teleoperating a Dexterous Robot Hand
Wang, J. Z., Wang, R. C., Li, F., Jiang, M., & Jin, D. W. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1615841 · Cited by 30
Comparative study of PCA in classification of multichannel EMG signals
Geethanjali, P. (2015) · Australasian Physical & Engineering Sciences in Medicine · doi:10.1007/s13246-015-0343-8 · Cited by 28
Self-citationEvolutionary fuzzy discriminant analysis feature projection technique in myoelectric control
Khushaba, R. N., Al-Jumaily, A. A., & Al-Ani, A. (2009) · Pattern Recognition Letters · doi:10.1016/j.patrec.2009.02.004 · Cited by 28
Channel and Feature Selection in Multifunction Myoelectric Control
Khushaba, R. N., & Al-Jumaily, A. A. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353509 · Cited by 26
Al-Ajam, Y., Lancashire, H. T., Pendegrass, C. J., Kang, N., Dowling, R., Taylor, S. J. G., & Blunn, G. W. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2241060 · Cited by 19
An innovative high-level human-robot interaction for disabled persons
Nilas, P., Rani, P., & Sarkar, N. (2004) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2004.1307406 · Cited by 19
EMG pattern recognition based on evidence accumulation for prosthesis control
Lee, S.-P., Park, S., Kim, J.-S., & Kim, I.-J. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1996.647514 · Cited by 19
Swarm Intelligence based Dimensionality Reduction for Myoelectric Control
Khushaba, R. N., Al-Ani, A., & Al-Jumaily, A. A. (2007) · International Conference on Intelligent Sensors, Sensor Networks and Information Processing · doi:10.1109/issnip.2007.4496907 · Cited by 18
Liu, X., Zhou, R., Yang, L., & Li, G. (2009) · IEEE Youth Conference on Information, Computing and Telecommunication (YC-ICT) · doi:10.1109/ycict.2009.5382366 · Cited by 15
Surface EMG classification using moving approximate entropy
Ahmad, S. A., & Chappell, P. H. (2007) · International Conference on Intelligent and Advanced Systems · doi:10.1109/icias.2007.4658567 · Cited by 13
Santa-Cruz, M. C., Riso, R. R., & Sepúlveda, F. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2001.1020458 · Cited by 11
Classification of Grasp Types through Wavelet Decomposition of EMG Signals
Kakoty, N. M., & Hazarika, S. M. (2009) · International Conference on Biomedical Engineering and Informatics (BMEI) · doi:10.1109/bmei.2009.5305493 · Cited by 9
Nazarpour, K., Sharafat, A. R., & Firoozabadi, M. (2005) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2005.1419615 · Cited by 7
An EMG classifying method based on Bayes' criterion
Lei, M., Zhi-zhong, W., Cai, L.-Y., Zhang, H., & Cai, H. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1998.744998 · Cited by 5
Zhizeng, L., & Gao, J. (2006) · International Conference on Neural Networks and Brain · doi:10.1109/icnnb.2005.1614910 · Cited by 5
Cited by
Hargrove, L. J., Miller, L. A., Turner, K., & Kuiken, T. A. (2017) · Scientific Reports · doi:10.1038/s41598-017-14386-w · Cited by 190
Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review
Yildiz, K. A., Shin, A. Y., & Kaufman, K. R. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00667-5 · Cited by 113
Shi, C., Yang, D., Zhao, J., & Liu, H. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.3007625 · Cited by 87
Frost, C. M., Ursu, D. C., Flattery, S. M., Nedic, A., Hassett, C. A., Moon, J. D., Buchanan, P. J., Brent Gillespie, R., Kung, T. A., Kemp, S. W. P., et al. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0452-1 · Cited by 68
Metadata
- Authors
- Geethanjali, P.
- Venue
- Medical Devices: Evidence and Research
- Publisher
- Informa UK Limited
- Published
- 2016-07
- Volume
- Volume 9
- Pages
- 247-255
- ISSN
- 1179-1470 (ISSN-L)
- OpenAlex
- W2501720163
- Cited by
- 342
- References
- 77
- FWCI
- 13.83
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.