The DOI matches its Crossref record.
A Microscale In Vitro Physiological Model of the Liver: Predictive Screens for Drug Metabolism and Enzyme Induction
Abstract
In vitro models of the liver using isolated primary hepatocytes have been used as screens for measuring the metabolism, toxicity and efficacy of xenobiotics, for studying hepatocyte proliferation, and as bioartificial liver support systems. Yet, primary isolated hepatocytes rapidly lose liver specific functions when maintained under standard in vitro cell culture conditions. Many modifications to conventional culture methods have been developed to foster retention of hepatocyte function. Still, not all of the important functions -- especially the biotransformation functions of the liver -- can as yet be replicated at desired levels, prompting continued development of new culture systems. In the first part of this article, we review primary hepatocyte in vitro systems used in metabolism and enzyme induction studies. We then describe a scalable microreactor system that fosters development of 3D-perfused micro-tissue units and show that primary rat cells cultured in this system are substantially closer to native liver compared to cells cultured by other in vitro methods, as assessed by a broad spectrum of gene expression, protein expression and biochemical activity metrics. These results provide a foundation for extension of this culture model to other applications in drug discovery -- as a model to study drug-drug interactions, as a model for the assessment of acute and chronic liver toxicity arising from exposure to drugs or environmental agents; and as a disease model for the study of viral hepatitis infection and cancer metastasis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
Capturing complex 3D tissue physiology in vitro
Griffith, L. G., & Swartz, M. A. (2006) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm1858 · Cited by 2,290
Self-citationEl-Ali, J., Sorger, P. K., & Jensen, K. F. (2006) · Nature · doi:10.1038/nature05063 · Cited by 2,102
Three-dimensional in vitro cell culture models in drug discovery and drug repositioning
Langhans, S. A. (2018) · Frontiers in Pharmacology · doi:10.3389/fphar.2018.00006 · Cited by 1,522
Microscale culture of human liver cells for drug development
Khetani, S. R., & Bhatia, S. N. (2008) · Nature Biotechnology · doi:10.1038/nbt1361 · Cited by 1,219
A guide to the organ-on-a-chip
Leung, C. M., de Haan, P., Ronaldson-Bouchard, K., Kim, G.-A., Ko, J., Rho, H. S., Chen, Z., Habibovic, P., Jeon, N. L., Takayama, S., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00118-6 · Cited by 1,116
Vinci, M., Gowan, S., Boxall, F., Patterson, L., Zimmermann, M., Court, W., Lomas, C., Mendiola, M., Hardisson, D., & Eccles, S. A. (2012) · BMC Biology · doi:10.1186/1741-7007-10-29 · Cited by 1,024
The ToxCast Program for Prioritizing Toxicity Testing of Environmental Chemicals
Dix, D. J., Houck, K. A., Martin, M. T., Richard, A. M., Setzer, R. W., & Kavlock, R. J. (2007) · Toxicological Sciences · doi:10.1093/toxsci/kfl103 · Cited by 1,012
Deterministically patterned biomimetic human iPSC-derived hepatic model via rapid 3D bioprinting
Ma, X., Qu, X., Zhu, W., Li, Y.-S., Yuan, S., Zhang, H., Liu, J., Wang, P., Lai, C. S. E., Zanella, F., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1524510113 · Cited by 872
Organogenesis and development of the liver
Si-Tayeb, K., Lemaigre, F. P., & Duncan, S. A. (2010) · Developmental Cell · doi:10.1016/j.devcel.2010.01.011 · Cited by 800
Acute liver failure: Summary of a workshop†
Lee, W. M., Squires, R. H., Nyberg, S. L., Doo, E., & Hoofnagle, J. H. (2008) · Hepatology · doi:10.1002/hep.22177 · Cited by 757
Microfluidic scaffolds for tissue engineering
Choi, N. W., Cabodi, M., Held, B., Gleghorn, J. P., Bonassar, L. J., & Stroock, A. D. (2007) · Nature Materials · doi:10.1038/nmat2022 · Cited by 622
Predicting drug metabolism: experiment and/or computation?
Kirchmair, J., Göller, A. H., Lang, D., Kunze, J., Testa, B., Wilson, I. D., Glen, R. C., & Schneider, G. (2015) · Nature Reviews Drug Discovery · doi:10.1038/nrd4581 · Cited by 502
Medical applications of membranes: Drug delivery, artificial organs and tissue engineering
Stamatialis, D. F., Papenburg, B. J., Gironés, M., Saiful, S., Bettahalli, S. N. M., Schmitmeier, S., & Wessling, M. (2008) · Journal of Membrane Science · doi:10.1016/j.memsci.2007.09.059 · Cited by 473
In vitro models for liver toxicity testing
Soldatow, V. Y., LeCluyse, E. L., Griffith, L. G., & Rusyn, I. (2013) · Toxicol. Res. · doi:10.1039/c2tx20051a · Cited by 472
Self-citationA practical guide to microfluidic perfusion culture of adherent mammalian cells
Kim, L., Toh, Y.-C., Voldman, J., & Yu, H. (2007) · Lab on a Chip · doi:10.1039/b704602b · Cited by 455
A Review of Three-Dimensional In Vitro Tissue Models for Drug Discovery and Transport Studies
Elliott, N. T., & Yuan, F. (2011) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.22257 · Cited by 449
Microfluidic cell culture systems for drug research
Wu, M.-H., Huang, S.-B., & Lee, G.-B. (2010) · Lab on a Chip · doi:10.1039/b921695b · Cited by 432
A microfluidic 3D hepatocyte chip for drug toxicity testing
Toh, Y.-C., Lim, T. C., Tai, D., Xiao, G., van Noort, D., & Yu, H. (2009) · Lab on a Chip · doi:10.1039/b900912d · Cited by 419
A novel 3D mammalian cell perfusion-culture system in microfluidic channels
Toh, Y.-C., Zhang, C., Zhang, J., Khong, Y. M., Chang, S., Samper, V. D., van Noort, D., Hutmacher, D. W., & Yu, H. (2007) · Lab on a Chip · doi:10.1039/b614872g · Cited by 414
Ma, X., Liu, J., Zhu, W., Tang, M., Lawrence, N., Yu, C., Gou, M., & Chen, S. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.06.011 · Cited by 401
Organotypic liver culture models: meeting current challenges in toxicity testing
LeCluyse, E. L., Witek, R. P., Andersen, M. E., & Powers, M. J. (2012) · Critical Reviews in Toxicology · doi:10.3109/10408444.2012.682115 · Cited by 363
Bavli, D., Prill, S., Ezra, E., Levy, G., Cohen, M., Vinken, M., Vanfleteren, J., Jaeger, M., & Nahmias, Y. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1522556113 · Cited by 362
Cell and tissue engineering for liver disease
Bhatia, S. N., Underhill, G. H., Zaret, K. S., & Fox, I. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3005975 · Cited by 309
3D Bioprinting of Tissue/Organ Models
Pati, F., Gantelius, J., & Svahn, H. A. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201505062 · Cited by 301
Kostadinova, R., Boess, F., Applegate, D., Suter, L., Weiser, T., Singer, T., Naughton, B., & Roth, A. (2013) · Toxicology and Applied Pharmacology · doi:10.1016/j.taap.2013.01.012 · Cited by 262
Modelling tissues in 3D: the next future of pharmaco-toxicology and food research?
Mazzoleni, G., Di Lorenzo, D., & Steimberg, N. (2009) · Genes & Nutrition · doi:10.1007/s12263-008-0107-0 · Cited by 253
Organs-on-a-chip: a new tool for drug discovery
Polini, A., Prodanov, L., Bhise, N. S., Manoharan, V., Dokmeci, M. R., & Khademhosseini, A. (2014) · Expert Opinion on Drug Discovery · doi:10.1517/17460441.2014.886562 · Cited by 223
Yoon No, D., Lee, K.-H., Lee, J., & Lee, S.-H. (2015) · Lab on a Chip · doi:10.1039/c5lc00611b · Cited by 205
Prantil-Baun, R., Novak, R., Das, D., Somayaji, M. R., Przekwas, A., & Ingber, D. E. (2018) · Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev-pharmtox-010716-104748 · Cited by 176
Microengineered Liver Tissues for Drug Testing
Khetani, S. R., Berger, D. R., Ballinger, K. R., Davidson, M. D., Lin, C., & Ware, B. R. (2015) · SLAS Technology · doi:10.1177/2211068214566939 · Cited by 116
“Twelve bioreactors have been engineered onto a single plate.(95,123) This platform is commercially available as LiverChip by CN Bio Innovations Limited (Oxfordshire, UK).”
BackgroundMethodInfluentialMicrofluidic devices for in vitro studies on liver drug metabolism and toxicity
van Midwoud, P. M., Verpoorte, E., & Groothuis, G. M. M. (2011) · Integrative Biology · doi:10.1039/c0ib00119h · Cited by 115
Hemodynamic flow improves rat hepatocyte morphology, function, and metabolic activity in vitro
Dash, A., Simmers, M. B., Deering, T. G., Berry, D. J., Feaver, R. E., Hastings, N. E., Pruett, T. L., LeCluyse, E. L., Blackman, B. R., & Wamhoff, B. R. (2013) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00331.2012 · Cited by 108
Lee, J. B., & Sung, J. H. (2013) · Biotechnology Journal · doi:10.1002/biot.201300086 · Cited by 92
Engineered Liver Platforms for Different Phases of Drug Development
Ware, B. R., & Khetani, S. R. (2017) · Trends in Biotechnology · doi:10.1016/j.tibtech.2016.08.001 · Cited by 90
“The Griffith group engineered a device in which preformed hepatic aggregates adhered to the collagen-coated walls of an array of micro-channels were perfused, which led to higher hepatic functions than static controls [35].”
Advances in Engineered Liver Models for Investigating Drug-Induced Liver Injury
Lin, C., & Khetani, S. R. (2016) · BioMed Research International · doi:10.1155/2016/1829148 · Cited by 66
3D Cultivation Techniques for Primary Human Hepatocytes
Bachmann, A., Moll, M., Gottwald, E., Nies, C., Zantl, R., Wagner, H., Burkhardt, B., Sánchez, J., Ladurner, R., Thasler, W., et al. (2015) · Microarrays · doi:10.3390/microarrays4010064 · Cited by 59
High-throughput transfection of interfering RNA into a 3D cell-culture chip
Zhang, H., Lee, M., Hogg, M. G., Dordick, J. S., & Sharfstein, S. T. (2012) · Small · doi:10.1002/smll.201102205 · Cited by 16
Metadata
- Authors
- Sivaraman, A., Leach, J., Townsend, S., Iida, T., Hogan, B., Stolz, D., Fry, R., Samson, L., Tannenbaum, S., & Griffith, L.
- Venue
- Current Drug Metabolism
- Publisher
- Bentham Science Publishers Ltd.
- Published
- 2005-12-01
- Volume
- 6
- Issue
- 6
- Pages
- 569-591
- ISSN
- 1389-2002 (ISSN-L)
- OpenAlex
- W2103895990
- Cited by
- 310
- References
- 0
- FWCI
- 10.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.