Wearable Health Devices in Health Care: Narrative Systematic Review
Open accessPublished version of a preprint
The DOI matches its Crossref record; 139 of the 139 references it cites were found in a registry or an index.
Abstract
Background: With the rise of mobile medicine, the development of new technologies such as smart sensing, and the popularization of personalized health concepts, the field of smart wearable devices has developed rapidly in recent years. Among them, medical wearable devices have become one of the most promising fields. These intelligent devices not only assist people in pursuing a healthier lifestyle but also provide a constant stream of health care data for disease diagnosis and treatment by actively recording physiological parameters and tracking metabolic status. Therefore, wearable medical devices have the potential to become a mainstay of the future mobile medical market. Objective: Although previous reviews have discussed consumer trends in wearable electronics and the application of wearable technology in recreational and sporting activities, data on broad clinical usefulness are lacking. We aimed to review the current application of wearable devices in health care while highlighting shortcomings for further research. In addition to daily health and safety monitoring, the focus of our work was mainly on the use of wearable devices in clinical practice. Methods: We conducted a narrative review of the use of wearable devices in health care settings by searching papers in PubMed, EMBASE, Scopus, and the Cochrane Library published since October 2015. Potentially relevant papers were then compared to determine their relevance and reviewed independently for inclusion. Results: A total of 82 relevant papers drawn from 960 papers on the subject of wearable devices in health care settings were qualitatively analyzed, and the information was synthesized. Our review shows that the wearable medical devices developed so far have been designed for use on all parts of the human body, including the head, limbs, and torso. These devices can be classified into 4 application areas: (1) health and safety monitoring, (2) chronic disease management, (3) disease diagnosis and treatment, and (4) rehabilitation. However, the wearable medical device industry currently faces several important limitations that prevent further use of wearable technology in medical practice, such as difficulties in achieving user-friendly solutions, security and privacy concerns, the lack of industry standards, and various technical bottlenecks. Conclusions: We predict that with the development of science and technology and the popularization of personalized health concepts, wearable devices will play a greater role in the field of health care and become better integrated into people’s daily lives. However, more research is needed to explore further applications of wearable devices in the medical field. We hope that this review can provide a useful reference for the development of wearable medical devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Unlike studies that advocate for the superiority of a single wearable device (31–33), our findings indicate that older adults expressed a clear preference for coordinated rather than substitutive device use.”
From Designing age-friendly interfaces and wearable–environment integrations to enhance medication adherence: a discrete choice experiment among older adults (2026) · cites this paper as [31]
Experimental — accuracy not yet measuredIn the citing paper
“These data may reflect users' living habits and health status and are at risk of being maliciously obtained or tampered with 176,183,184 .”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [176]
In the citing paper
“The current health data cloud infrastructure is inadequate, causing data transmission delays and insufficient real-time feedback, which affects the response efficiency of intention prediction in complex scenarios 175,176 .”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [176]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diagnosis and Classification of Diabetes Mellitus
American Diabetes Association (2011) · Diabetes Care · doi:10.2337/dc11-s062 · Cited by 13,988
A typology of reviews: an analysis of 14 review types and associated methodologies
Grant, M. J., & Booth, A. (2009) · Health Information & Libraries Journal · doi:10.1111/j.1471-1842.2009.00848.x · Cited by 10,817
Lane, C. A., Hardy, J., & Schott, J. M. (2018) · European Journal of Neurology · doi:10.1111/ene.13439 · Cited by 2,616
Diagnosis and classification of diabetes mellitus
American Diabetes Association (2013) · Diabetes Care · doi:10.2337/dc13-s067 · Cited by 2,245
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
Oparil, S., Acelajado, M. C., Bakris, G. L., Berlowitz, D. R., Cífková, R., Dominiczak, A. F., Grassi, G., Jordan, J., Poulter, N. R., Rodgers, A., et al. (2018) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2018.14 · Cited by 1,167
Smart wearable systems: Current status and future challenges
Chan, M., Estève, D., Fourniols, J.-Y., Escriba, C., & Campo, E. (2012) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2012.09.003 · Cited by 953
State of the Art and Future Directions for Lower Limb Robotic Exoskeletons
Young, A. J., & Ferris, D. P. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2521160 · Cited by 901
Neuroplasticity in the context of motor rehabilitation after stroke
Dimyan, M. A., & Cohen, L. G. (2011) · Nature Reviews Neurology · doi:10.1038/nrneurol.2010.200 · Cited by 732
Haghi, M., Thurow, K., & Stoll, R. (2017) · Healthcare Informatics Research · doi:10.4258/hir.2017.23.1.4 · Cited by 711
Evolution of Wearable Devices with Real-Time Disease Monitoring for Personalized Healthcare
Guk, K., Han, G., Lim, J., Jeong, K., Kang, T., Lim, E.-K., & Jung, J. (2019) · Nanomaterials · doi:10.3390/nano9060813 · Cited by 624
Yetisen, A. K., Martinez‐Hurtado, J. L., Ünal, B., Khademhosseini, A., & Butt, H. (2018) · Advanced Materials · doi:10.1002/adma.201706910 · Cited by 569
Loss of arm function after stroke: measurement, frequency, and recovery
Parker, V. M., Wade, D. T., & Hewer, R. L. (1986) · International Rehabilitation Medicine · doi:10.3109/03790798609166178 · Cited by 517
Sim, I. (2019) · New England Journal of Medicine · doi:10.1056/nejmra1806949 · Cited by 491 · cited 3×
“(5) Other issues such as cost, low data collection and processing efficiency, unstable human-computer interaction interfaces, and incomplete construction of big data health clouds need to be further improved [9,13,122].”
BackgroundDisruptive, Soft, Wearable Sensors
Ling, Y., An, T., Yap, L. W., Zhu, B., Gong, S., & Cheng, W. (2020) · Advanced Materials · doi:10.1002/adma.201904664 · Cited by 480
Using Technology to Meet the Challenges of Medical Education.
Guze, P. A. (2015) · Europe PMC (PubMed Central) · Cited by 467
Diagnostic Inaccuracy of Smartphone Applications for Melanoma Detection
Wolf, J. A., Moreau, J. F., Akilov, O., Patton, T., English, J. C., Ho, J., & Ferris, L. K. (2013) · JAMA Dermatology · doi:10.1001/jamadermatol.2013.2382 · Cited by 393
Toward Flexible and Wearable Human‐Interactive Health‐Monitoring Devices
Takei, K., Honda, W., Harada, S., Arie, T., & Akita, S. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400546 · Cited by 371
Interactive wearable systems for upper body rehabilitation: a systematic review
Wang, Q., Markopoulos, P., Yu, B., Chen, W., & Timmermans, A. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0229-y · Cited by 348
Chirico, A., Lucidi, F., De Laurentiis, M., Milanese, C., Napoli, A., & Giordano, A. (2016) · Journal of Cellular Physiology · doi:10.1002/jcp.25117 · Cited by 342
Faria, A. L., Andrade, A., Soares, L., & i Badia, S. B. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0204-z · Cited by 307
Sockets for Limb Prostheses: A Review of Existing Technologies and Open Challenges
Paterno, L., Ibrahimi, M., Gruppioni, E., Menciassi, A., & Ricotti, L. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2775100 · Cited by 301
Noninvasive Monitoring of Blood Glucose with Raman Spectroscopy
Pandey, R., Paidi, S. K., Valdez, T. A., Zhang, C., Spegazzini, N., Dasari, R. R., & Barman, I. (2017) · Accounts of Chemical Research · doi:10.1021/acs.accounts.6b00472 · Cited by 290 · cited 1×
“The principle of the measurement is based on concentration-dependent changes in the absorption and reflection characteristics of glucose [65].”
BackgroundWearable and Implantable Sensors for Biomedical Applications
Koydemir, H. C., & Ozcan, A. (2018) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061417-125956 · Cited by 289
Maceira-Elvira, P., Popa, T., Schmid, A.-C., & Hummel, F. C. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0612-y · Cited by 265
Khan, S., Ali, S., & Bermak, A. (2019) · Sensors · doi:10.3390/s19051230 · Cited by 253
Mannini, A., Trojaniello, D., Cereatti, A., & Sabatini, A. (2016) · Sensors · doi:10.3390/s16010134 · Cited by 242
Loncar-Turukalo, T., Zdravevski, E., Machado da Silva, J., Chouvarda, I., & Trajkovik, V. (2019) · Journal of Medical Internet Research · doi:10.2196/14017 · Cited by 240
Godinho, C., Domingos, J., Cunha, G., Santos, A. T., Fernandes, R. M., Abreu, D., Gonçalves, N., Matthews, H., Isaacs, T., Duffen, J., et al. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0136-7 · Cited by 226
Advanced biosensors for glucose and insulin
Sabu, C., Henna, T. K., Raphey, V. R., Nivitha, K. P., & Pramod, K. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.03.034 · Cited by 221
Baig, M. M., Afifi, S., GholamHosseini, H., & Mirza, F. (2019) · Journal of Medical Systems · doi:10.1007/s10916-019-1365-7 · Cited by 215
Elliott, W. J. (2007) · Current Problems in Cardiology · doi:10.1016/j.cpcardiol.2007.01.002 · Cited by 208
Health literacy in chronic disease management: a matter of interaction
van der Heide, I., Poureslami, I., Mitic, W., Shum, J., Rootman, I., & FitzGerald, J. M. (2018) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2018.05.010 · Cited by 182
A wearable artificial kidney for patients with end-stage renal disease
Gura, V., Rivara, M. B., Bieber, S., Munshi, R., Smith, N. C., Linke, L., Kundzins, J., Beizai, M., Ezon, C., Kessler, L., et al. (2016) · JCI Insight · doi:10.1172/jci.insight.86397 · Cited by 180
Ethical Implications of User Perceptions of Wearable Devices
Segura Anaya, L. H., Alsadoon, A., Costadopoulos, N., & Prasad, P. W. C. (2018) · Science and Engineering Ethics · doi:10.1007/s11948-017-9872-8 · Cited by 177
Rogers, J. M., Duckworth, J., Middleton, S., Steenbergen, B., & Wilson, P. H. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0531-y · Cited by 169
Wearable devices in healthcare: Privacy and information security issues
Cilliers, L. (2020) · Health Information Management Journal · doi:10.1177/1833358319851684 · Cited by 169
Recent Progress in Wireless Sensors for Wearable Electronics
Park, Y., Lee, S.-I., & Park, J. (2019) · Sensors · doi:10.3390/s19204353 · Cited by 169
Lee, S., Kim, J., Baker, L., Long, A., Karavas, N., Menard, N., Galiana, I., & Walsh, C. J. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0410-y · Cited by 166
Common and rare forms of diabetes mellitus: towards a continuum of diabetes subtypes
Flannick, J. A., Johansson, S., & Njølstad, P. R. (2016) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2016.50 · Cited by 165
Application and Prospect of Mixed Reality Technology in Medical Field
Hu, H.-Z., Feng, X.-B., Shao, Z.-W., Xie, M., Xu, S., Wu, X.-H., & Ye, Z.-W. (2019) · Current Medical Science · doi:10.1007/s11596-019-1992-8 · Cited by 164
Self-citationOnline Obstructive Sleep Apnea Detection on Medical Wearable Sensors
Surrel, G., Aminifar, A., Rincon, F., Murali, S., & Atienza, D. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2824659 · Cited by 156
Wearable Devices for Precision Medicine and Health State Monitoring
Jeong, I. C., Bychkov, D., & Searson, P. C. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2871638 · Cited by 155 · cited 1×
“On one hand, wearable technologies will play a significant role in advancing precision medicine by enabling measurement of clinically relevant parameters showing the health status of individuals [11].”
BackgroundLiang, J., Xian, D., Liu, X., Fu, J., Zhang, X., Tang, B., & Lei, J. (2018) · JMIR mhealth and uhealth · doi:10.2196/11066 · Cited by 154
Recent advances in noninvasive flexible and wearable wireless biosensors
Salim, A., & Lim, S. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111422 · Cited by 153
Wan, E. Y. F., Fung, C. S. C., Jiao, F. F., Yu, E. Y. T., Chin, W. Y., Fong, D., Wong, C. K. H., Chan, A. K. C., Chan, K. H. Y., Kwok, R. L. P., et al. (2017) · Diabetes Care · doi:10.2337/dc17-0426 · Cited by 146
Monje, M. H. G., Foffani, G., Obeso, J. A., & Sánchez‐Ferro, Á. (2019) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-121036 · Cited by 143
mHealth For Aging China: Opportunities and Challenges
Sun, J., Guo, Y., Wang, X., & Zeng, Q. (2016) · Aging and Disease · doi:10.14336/ad.2015.1011 · Cited by 142
Jo, A., Coronel, B. D., Coakes, C. E., & Mainous, A. G. (2019) · The American Journal of Medicine · doi:10.1016/j.amjmed.2019.06.018 · Cited by 142
Wearables for independent living in older adults: Gait and falls
Godfrey, A. (2017) · Maturitas · doi:10.1016/j.maturitas.2017.03.317 · Cited by 141
From Backpacks to Smartphones: Past, Present, and Future of Wearable Computers
Amft, O., & Lukowicz, P. (2009) · IEEE Pervasive Computing · doi:10.1109/mprv.2009.44 · Cited by 130
Epidemiology, risk factors and management of cardiovascular diseases in IBD
Singh, S., Kullo, I. J., Pardi, D. S., & Loftus, E. V. (2014) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/nrgastro.2014.202 · Cited by 127
Measurement of Upper Limb Range of Motion Using Wearable Sensors: A Systematic Review
Walmsley, C. P., Williams, S. A., Grisbrook, T., Elliott, C., Imms, C., & Campbell, A. (2018) · Sports Medicine - Open · doi:10.1186/s40798-018-0167-7 · Cited by 123
Virtual Reality in the Assessment of Selected Cognitive Function After Brain Injury
Zhang, L., Abreu, B. C., Masel, B. E., Scheibel, R. S., Christiansen, C. H., Huddleston, N., & Ottenbacher, K. J. (2001) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-200108000-00010 · Cited by 122
Differentiating dementia disease subtypes with gait analysis: feasibility of wearable sensors?
Ardle, R. M., Din, S. D., Galna, B., Thomas, A. J., & Rochester, L. (2019) · Gait & Posture · doi:10.1016/j.gaitpost.2019.12.028 · Cited by 121
Rodgers, M. M., Alon, G., Pai, V. M., & Conroy, R. S. (2019) · Journal of Rehabilitation and Assistive Technologies Engineering · doi:10.1177/2055668319839607 · Cited by 119
Validation of wearable textile electrodes for ECG monitoring
Tsukada, Y. T., Tokita, M., Murata, H., Hirasawa, Y., Yodogawa, K., Iwasaki, Y., Asai, K., Shimizu, W., Kasai, N., Nakashima, H., et al. (2019) · Heart and Vessels · doi:10.1007/s00380-019-01347-8 · Cited by 117
Sequeira, L., Perrotta, S., LaGrassa, J., Merikangas, K. R., Kreindler, D. M., Kundur, D., Courtney, D., Szatmári, P., Battaglia, M., & Strauss, J. (2019) · Journal of Affective Disorders · doi:10.1016/j.jad.2019.11.156 · Cited by 115
Robot-assisted gait rehabilitation: From exoskeletons to gait systems
Low, K. H. (2011) · Defense Science Research Conference and Expo (DSR) · doi:10.1109/dsr.2011.6026886 · Cited by 110
Steinberg, C., Philippon, F., Sánchez, M., Fortier-Poisson, P., O’Hara, G. E., Molin, F., SARRAZIN, J., Nault, I., Blier, L. E., Roy, K., et al. (2019) · Biosensors · doi:10.3390/bios9010017 · Cited by 108
Wearable Ankle Robots in Post-stroke Rehabilitation of Gait: A Systematic Review
Shi, B., Chen, X., Yue, Z., Yin, S., Weng, Q., Zhang, X., Wang, J., & Wen, W. (2019) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2019.00063 · Cited by 107
Wearable technologies – future challenges for implementation in healthcare services
Lewy, H. (2015) · Healthcare Technology Letters · doi:10.1049/htl.2014.0104 · Cited by 106
Wearable Fall Detector using Integrated Sensors and Energy Devices
Jung, S., Hong, S., Kim, J., Lee, S., Hyeon, T., Lee, M., & Kim, D. (2015) · Scientific Reports · doi:10.1038/srep17081 · Cited by 105
Hsu, W.-C., Sugiarto, T., Lin, Y.-J., Yang, F.-C., Lin, Z.-Y., Sun, C.-T., Hsu, C.-L., & Chou, K.-N. (2018) · Sensors · doi:10.3390/s18103397 · Cited by 101
Weiss, P. L., Naveh, Y., & Katz, N. (2003) · Occupational Therapy International · doi:10.1002/oti.176 · Cited by 99
Priore, C. L., Castelnuovo, G., Liccione, D., & Liccione, D. (2003) · CyberPsychology & Behavior · doi:10.1089/109493103322011579 · Cited by 96
Zheng, Y., Poon, C. C. Y., Yan, B. P., & Lau, J. Y. W. (2016) · Journal of Medical Systems · doi:10.1007/s10916-016-0558-6 · Cited by 93
Wearable physiological systems and technologies for metabolic monitoring
Gao, W., Brooks, G. A., & Klonoff, D. C. (2018) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00407.2017 · Cited by 91 · cited 1×
“The main methods are spectrometry, blood substitution (urine, tears, and tissue fluid), counter-ion electroosmosis, and microwave technology [63,64].”
MethodWearable devices for sudden unexpected death in epilepsy prevention
Ryvlin, P., Ciumas, C., Wisniewski, I., & Beniczky, S. (2018) · Epilepsia · doi:10.1111/epi.14054 · Cited by 90
Design features of implants for direct skeletal attachment of limb prostheses
Pitkin, M. R. (2013) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34606 · Cited by 88
Ricci, M., Lazzaro, G. D., Pisani, A., Mercuri, N. B., Giannini, F., & Saggio, G. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2903627 · Cited by 82
Consumers’ perceived attitudes to wearable devices in health monitoring in China: A survey study
Wen, D., Zhang, X., & Lei, J. (2016) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2016.12.009 · Cited by 80
The use of virtual reality in memory rehabilitation: Current findings and future directions
Brooks, B., & Rose, F. D. (2003) · Neurorehabilitation · doi:10.3233/nre-2003-18207 · Cited by 79
Real-Time Control of an Exoskeleton Hand Robot with Myoelectric Pattern Recognition
Lu, Z., Chen, X. '., Zhang, X., Tong, R. K., & Zhou, P. (2016) · International Journal of Neural Systems · doi:10.1142/s0129065717500095 · Cited by 79
Mackintosh, K. A., Chappel, S. E., Salmon, J., Timperio, A. F., Ball, K., Brown, H. L., Macfarlane, S., & Ridgers, N. D. (2019) · JMIR mhealth and uhealth · doi:10.2196/13858 · Cited by 78
Xu, J., Bao, T., Lee, U. H., Kinnaird, C. R., Carender, W. J., Huang, Y., Sienko, K. H., & Shull, P. B. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0313-3 · Cited by 76
Virtual Reality for Screening of Cognitive Function in Older Persons: Comparative Study
Chua, S. I. L., Tan, N. C., Wong, W. T., Allen, J. C., Quah, J. H. M., Malhotra, R., & Østbye, T. (2019) · Journal of Medical Internet Research · doi:10.2196/14821 · Cited by 76
Wearable Devices for Cardiac Rhythm Diagnosis and Management
Ip, J. E. (2019) · JAMA · doi:10.1001/jama.2018.20437 · Cited by 72
Virtual reality for relearning daily living skills
Gourlay, D., Lun, K. C., Lee, Y. N., & Tay, J. (2000) · International Journal of Medical Informatics · doi:10.1016/s1386-5056(00)00100-3 · Cited by 69
Mobile personal health records for pregnancy monitoring functionalities: Analysis and potential
Bachiri, M., Idri, A., Fernández‐Alemán, J. L., & Toval, A. (2016) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2016.06.008 · Cited by 69
Mandell, J. C., Khurana, B., & Smith, S. E. (2017) · Skeletal Radiology · doi:10.1007/s00256-017-2640-7 · Cited by 69
A wearable IoT aldehyde sensor for pediatric asthma research and management
Li, B., Dong, Q., Downen, R. S., Tran, N. A., Jackson, J. H., Pillai, D. K., Zaghloul, M. E., & Li, Z. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.02.077 · Cited by 68
Home Stroke Rehabilitation for the Upper Limbs
Willmann, R. D., Lanfermann, G., Saini, P. K., Timmermans, A. A. A., Vrugt, J. T., & Winter, S. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353214 · Cited by 67
Rubio, N., Parker, R. A., Drost, E., Pinnock, H., Weir, C. J., Hanley, J., Mantoani, L. C., MacNee, W., McKinstry, B., & Rabinovich, R. (2017) · International Journal of COPD · doi:10.2147/copd.s120706 · Cited by 65
Hwang, J.-H., & Lee, S. (2017) · Journal of Physical Therapy Science · doi:10.1589/jpts.29.1283 · Cited by 65
Wearable Chemosensors: A Review of Recent Progress
Qian, R., & Long, Y. (2017) · ChemistryOpen · doi:10.1002/open.201700159 · Cited by 63
Jackson, M. M., Valentin, G., Freil, L., Burkeen, L., Zeagler, C., Gilliland, S. M., Currier, B., & Starner, T. E. (2014) · Personal and Ubiquitous Computing · doi:10.1007/s00779-014-0817-9 · Cited by 62
Wu, R. C., Liaqat, D., de Lara, E., Son, T., Rudzicz, F., Alshaer, H., Abed-Esfahani, P., & Gershon, A. S. (2018) · JMIR mhealth and uhealth · doi:10.2196/10046 · Cited by 61
Wang, C.-Y., Hwang, W., Fang, J., Sheu, C., Leong, I.-F., & Ma, H. (2011) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2011.03.014 · Cited by 59
Powell, L., Parker, J., James, M. M., & Mawson, S. (2016) · Journal of Medical Internet Research · doi:10.2196/jmir.5891 · Cited by 59
Asthma Management in the Era of Smart-Medicine: Devices, Gadgets, Apps and Telemedicine
Katwa, U., & Rivera, E. (2018) · The Indian Journal of Pediatrics · doi:10.1007/s12098-018-2611-6 · Cited by 58
Holt, T. R., Withington, D. E., & Mitchell, E. (2011) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0b013e3182230f43 · Cited by 57
Islam, S. M. S., Cartledge, S., Karmakar, C., Rawstorn, J. C., Fraser, S. F., Chow, C., & Maddison, R. (2019) · JMIR mHealth and uHealth · doi:10.2196/14706 · Cited by 57 · cited 1×
“In a mixed methods study, Islam et al [74] demonstrated that wearable blood pressure device measurements compared well against a gold-standard ambulatory device, indicating that this user-friendly method has the potential to enhance blood pressure management in long-term monitoring.”
MethodA Systematic Review of Wearable Systems for Cancer Detection: Current State and Challenges
Ray, P. P., Dash, D., & De, D. (2017) · Journal of Medical Systems · doi:10.1007/s10916-017-0828-y · Cited by 55
Argent, R., Slevin, P., Bevilacqua, A., Neligan, M. C., Daly, A., & Caulfield, B. M. (2018) · BMJ Open · doi:10.1136/bmjopen-2018-026326 · Cited by 54
Rheumatology 4.0: big data, wearables and diagnosis by computer
Burmester, G. R. (2018) · Annals of the Rheumatic Diseases · doi:10.1136/annrheumdis-2017-212888 · Cited by 53
Usefulness of Wearable Cameras as a Tool to Enhance Chronic Disease Self-Management: Scoping Review
Maddison, R., Cartledge, S. H., Rogerson, M., Goedhart, N. S., Singh, T. R., Neil, C., Phung, D., & Ball, K. (2018) · JMIR mhealth and uhealth · doi:10.2196/10371 · Cited by 49
A ZigBee-Based Location-Aware Fall Detection System for Improving Elderly Telecare
Huang, C.-N., & Chan, C.-T. (2014) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph110404233 · Cited by 46
Validity of energy expenditure estimation methods during 10 days of military training
Siddall, A. G., Powell, S. D., Needham‐Beck, S. C., Edwards, V. C., Thompson, J. E. S., Kefyalew, S. S., Singh, P., Orford, E. R., Venables, M., Jackson, S., et al. (2019) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.13488 · Cited by 44
Wu, X., Liu, R., Yu, J., Xu, S., Cao, Y., Yang, S., Shao, Z., & Ye, Z. (2018) · Surgical Innovation · doi:10.1177/1553350618761758 · Cited by 42
Self-citationWilliamson, B., Aplin, T., de Jonge, D., & Goyne, M. (2017) · Disability and Rehabilitation Assistive Technology · doi:10.1080/17483107.2016.1272140 · Cited by 40
Using photoplethysmography in heart rate monitoring of patients with epilepsy
van Andel, J., Ungureanu, C., Aarts, R., Leijten, F., & Arends, J. (2015) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2015.02.018 · Cited by 39
Popp, W., Schneider, S., Bär, J., Bösch, P., Spengler, C. M., Gassert, R., & Curt, A. E. P. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.01092 · Cited by 38
Control of virtual environments for young people with learning difficulties
Lannen, T. L., Brown, D. J., & Powell, H. M. (2002) · Disability and Rehabilitation · doi:10.1080/09638280110111342 · Cited by 37
Souza, P. E., Arehart, K. H., Schoof, T., Anderson, M. C., Strori, D., & Balmert, L. C. (2019) · Ear and Hearing · doi:10.1097/aud.0000000000000717 · Cited by 36
Fumagalli, S., Chen, J., Dobreanu, D., Hernández‐Madrid, A., Tilz, R. R., & Dagres, N. (2016) · EP Europace · doi:10.1093/europace/euw090 · Cited by 34
Pillalamarri, S. S., Huyett, L. M., & Abdel-Malek, A. A. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818804802 · Cited by 34
Odeneg, T., Ebner, C., Mörtl, D., Keller, H., Dirninger, A., Stix, G., Föger, B., Grimm, G., Steinwender, C., Gebetsberger, F., et al. (2018) · European Journal of Cardiovascular Nursing · doi:10.1177/1474515118790365 · Cited by 33
A Synergy-Based Optimally Designed Sensing Glove for Functional Grasp Recognition
Ciotti, S., Battaglia, E., Carbonaro, N., Bicchi, A., Tognetti, A., & Bianchi, M. (2016) · Sensors · doi:10.3390/s16060811 · Cited by 32
Wireless Sensor Networks for Ambient Assisted Living
Aquino-Santos, R., Martínez-Castro, D., Edwards-Block, A., & Murillo-Piedrahita, A. (2013) · Sensors · doi:10.3390/s131216384 · Cited by 31
Children with Nocturnal Asthma Wheeze Intermittently During Sleep
Boner, A. L., PIACENTINI, G. L., Peroni, D. G., Irving, C. S., Goldstein, D., Gavriely, N., & Godfrey, S. (2010) · Journal of Asthma · doi:10.3109/02770900903497188 · Cited by 31
Jayaraman, C., Mummidisetty, C. K., Mannix-Slobig, A., Koch, L. L. M., & Jayaraman, A. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0358-y · Cited by 30
Mixed Reality Technology–Assisted Orthopedics Surgery Navigation
Wu, X., Liu, R., Yu, J., Xu, S., Cao, Y., Shao, Z., Yang, S., & Ye, Z. (2018) · Surgical Innovation · doi:10.1177/1553350618771413 · Cited by 30
Self-citationPericleous, P., & van Staa, T. P. (2019) · International Journal of COPD · doi:10.2147/copd.s193037 · Cited by 26
A wearable real-time image processor for a vision prosthesis
Tsai, D., Morley, J. W., Suaning, G. J., & Lovell, N. H. (2009) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2009.03.009 · Cited by 23
Assessment and training of locomotion after stroke: evolving concepts
Malouin, F. (2005) · Elsevier eBooks · doi:10.1016/b978-0-7506-5564-4.50012-7 · Cited by 23
Decision Making Concepts for the Remote, Personalized Evaluation of COPD Patients’ Health Status
Colantonio, S., Govoni, L., Dellacà, R. L., Martinelli, M., Vitacca, M., & Salvetti, O. (2014) · Methods of Information in Medicine · doi:10.3414/me13-02-0038 · Cited by 22
Likitlersuang, J., Sumitro, E. R., Theventhiran, P., Kalsi‐Ryan, S., & Zariffa, J. (2017) · Journal of Spinal Cord Medicine · doi:10.1080/10790268.2017.1349856 · Cited by 21
Rehabilitation in chronic spatial neglect strengthens resting-state connectivity
Wåhlin, A., Fordell, H., Ekman, U., Lenfeldt, N., & Malm, J. (2018) · Acta Neurologica Scandinavica · doi:10.1111/ane.13048 · Cited by 21
Prioreschi, A., Nappey, T., Westgate, K. L., Olivier, P. L., Brage, S., & Micklesfield, L. K. (2018) · Pilot and Feasibility Studies · doi:10.1186/s40814-018-0256-x · Cited by 20
Long-term use of the wearable cardioverter defibrillator in patients with explanted ICD
Kaspar, G., Sanam, K., Gholkar, G., Bianco, N. R., Szymkiewicz, S. J., & Shah, D. P. (2018) · International Journal of Cardiology · doi:10.1016/j.ijcard.2018.08.017 · Cited by 20
Rehabilitation of Cognitive Dysfunction Following Traumatic Brain Injury
Eshel, I., Bowles, A. O., & Ray, M. R. (2018) · Physical Medicine and Rehabilitation Clinics of North America · doi:10.1016/j.pmr.2018.08.005 · Cited by 20
Preliminary evaluation of Wearable Wellness System for Obstructive Sleep Apnea detection
Crupi, R., Faetti, T., & Paradiso, R. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319306 · Cited by 19
Wearable Smart Devices for P4 Medicine in Heart Disease: Ready for Medical Cyber-Physical Systems?
Lin, B. (2019) · OMICS A Journal of Integrative Biology · doi:10.1089/omi.2019.0059 · Cited by 15
Wu, X., Liu, R., Xu, S., Cao, Y., Yang, S., Shao, Z., Li, S., & Ye, Z. (2019) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411919881255 · Cited by 15
Self-citationAn Ethernet motion-sensor based alarm system for epilepsy monitoring
Bonnet, S., Jallon, P., Bourgerette, A., Antonakios, M., Guillemaud, R., Caritu, Y., Becq, G., Kahane, P., Chapat, P., Thomas-Vialettes, B., et al. (2011) · IRBM · doi:10.1016/j.irbm.2011.01.021 · Cited by 14
Celik, N., & Rohrschneider, K. (2018) · Der Ophthalmologe · doi:10.1007/s00347-017-0644-2 · Cited by 11
New wearable walking-type continuous passive motion device for postsurgery walking rehabilitation
Zhu, Y., Nakamura, M., Horiuchi, T., Kohno, H., Takahashi, R., Terada, H., & Haro, H. (2013) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411913481557 · Cited by 9
Cheng, H., Sung, S., Chen, C.-H., Yu, W., Yang, S.-M., Guo, C., Chuang, S., & Chiang, C. (2019) · Trials · doi:10.1186/s13063-019-3366-8 · Cited by 9
[Virtual healthcare; use of virtual, augmented and mixed reality].
van Genderen, M. E., & Vlake, J. H. (2018) · Nederlandsch tijdschrift voor geneeskunde/Nederlands tijdschrift voor geneeskunde/NTvG-databank · Cited by 9
Tentolouris, A., Eleftheriadou, I., Tzeravini, E., Athanasakis, K., Anastasiou, I. A., Kyriopoulos, J. E., & Tentolouris, N. (2019) · Diabetes & Metabolic Syndrome Clinical Research & Reviews · doi:10.1016/j.dsx.2019.01.030 · Cited by 6
Homma, T., Kawahara, T., Mikuni, H., Uno, T., Sato, H., Fujiwara, A., Uchida, Y., Fukuda, Y., Manabe, R., Ida, H., et al. (2019) · International Archives of Allergy and Immunology · doi:10.1159/000495761 · Cited by 6
Current and future perspective in the management of diabetes.
Vishwanathan, V. (2002) · PubMed · Cited by 5
Lončar-Turukalo, T., Zdravevski, E., da Silva, J. M., Chouvarda, I., & Trajkovik, V. (2019) · doi:10.2196/preprints.14017 · Cited by 5
A Wearable IoT Aldehyde Sensor for Pediatric Asthma Research and ManagementPreprint
Li, B., Dong, Q., Downen, R. S., et al. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1811.07287 · Cited by 3
Wearable medical device improves survival for glioblastoma patients
(2017) · Cancer · doi:10.1002/cncr.30963 · Cited by 3
Pavlova, K. (2019) · Columbia University Press eBooks · doi:10.7312/pavl19078-005 · Cited by 3
(2002) · Soldering and Surface Mount Technology · doi:10.1108/ssmt.2002.21914cab.006 · Cited by 2
[Electrophysiological classification of myocardial infarct].
Zl, D. (1975) · PubMed · Cited by 1
Research works printed but not linked: 11
- Guze, PA, 2015, Trans Am Clin Climatol Assoc, 126, 260
- 10.3969/j.issn.1003-3025.2011.12.029 · doi:10.3969/j.issn.1003-3025.2011.12.029
- Dolabchian, ZL, 1975, Kardiologiia, 15, 113
- Vishwanathan, V, 2002, J Indian Med Assoc, 100, 181
- 10.3969/j.issn.1674-1633.2017.06.001 · doi:10.3969/j.issn.1674-1633.2017.06.001
- 10.3969/j.issn.1674-1633.2016.12.019 · doi:10.3969/j.issn.1674-1633.2016.12.019
- van Genderen, Michel E, 2018, Ned Tijdschr Geneeskd, 162
- 10.3969/j.issn.1000-3614.2019.02.001 · doi:10.3969/j.issn.1000-3614.2019.02.001
- 10.3969/j.issn.2095-9958.2018.02.016 · doi:10.3969/j.issn.2095-9958.2018.02.016
- 10.1186/s12984-016-0204-z · DOI · Paper page
- 10.3390/s19204353 · DOI
Cited by
Hybrid multimodal wearable sensors for comprehensive health monitoring
Mahato, K., Saha, T., Ding, S., Sandhu, S. S., Chang, A.-Y., & Wang, J. (2024) · Nature Electronics · doi:10.1038/s41928-024-01247-4 · Cited by 404
Canali, S., Schiaffonati, V., & Aliverti, A. (2022) · PLOS Digital Health · doi:10.1371/journal.pdig.0000104 · Cited by 378
Fahim, Y. A., Hasani, I. W., Kabba, S., & Ragab, W. M. (2025) · European Journal of Medical Research · doi:10.1186/s40001-025-03196-w · Cited by 329
“Research highlights their particular value in chronic disease management, where real-time physiological monitoring enhances clinical decision-making [124].”
Xie, Y., Lu, L., Gao, F., He, S.-J., Zhao, H.-J., Fang, Y., Yang, J.-M., An, Y., Ye, Z.-W., & Dong, Z. (2021) · Current Medical Science · doi:10.1007/s11596-021-2485-0 · Cited by 234
Self-citationIntegrating Artificial Intelligence and Wearable IoT System in Long-Term Care Environments
Wang, W., & Hsu, W.-S. (2023) · Sensors · doi:10.3390/s23135913 · Cited by 187
Metadata
- Authors
- Lu, L., Zhang, J., Xie, Y., Gao, F., Xu, S., Wu, X., & Ye, Z.
- Affiliations
- Wuhan Union Hospital (CN)
- Corresponding author
- Ye, Zhewei
- Venue
- JMIR mHealth and uHealth
- Publisher
- JMIR Publications Inc.
- Published
- 2020-11-09
- Volume
- 8
- Issue
- 11
- Pages
- e18907
- ISSN
- 2291-5222 (ISSN-L)
- PMC
- PMC7683248
- OpenAlex
- W3087846344
- Cited by
- 701
- References
- 138
- Citations by year
- 2026: 115 · 2025: 194 · 2024: 176 · 2023: 111 · 2022: 66 · 2021: 38
- FWCI
- 4.49
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- JMIR mhealth and uhealth (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- National Natural Science Foundation of China (81974355)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Keywords
- wearable medical devices, health monitoring, chronic disease management, disease diagnosis, rehabilitation, physiological monitoring, data security and privacy, industry standards, personalized healthcare, mobile health
- MeSH terms
- Wearable Electronic Devices, Delivery of Health Care, Health Facilities, Humans, Technology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.
