The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
CT artifacts: causes and reduction techniques
Abstract
Artifacts are commonly encountered in clinical computed tomography (CT), and may obscure or simulate pathology. There are many different types of CT artifacts, including noise, beam hardening, scatter, pseudoenhancement, motion, cone beam, helical, ring, and metal artifacts. We review the cause and appearance of each type of artifact, correct some popular misconceptions, and describe modern techniques for artifact reduction. Noise can be reduced using iterative reconstruction or by combining data from multiple scans. This enables lower radiation dose and higher resolution scans. Metal artifacts can also be reduced using iterative reconstruction, resulting in more accurate diagnosis. Dual and multi-energy (photon counting) CT can reduce beam hardening and provide better tissue contrast. Methods for reducing noise and out-of-field artifacts may enable ultra-high resolution limited-field-of-view imaging of tumors and other structures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Feldkamp, L. A., Davis, L. C., & Kress, J. W. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000612 · Cited by 6,319
Energy-selective reconstructions in X-ray computerised tomography
Alvarez, R. E., & Macovski, A. (1976) · Physics in Medicine & Biology · doi:10.1088/0031-9155/21/5/002 · Cited by 2,013
Artifacts in CT: Recognition and Avoidance
Barrett, J. F., & Keat, N. (2004) · RadioGraphics · doi:10.1148/rg.246045065 · Cited by 1,688
Computed Tomography: Principles, Design, Artifacts, and Recent Advances
Hsieh, J. (2015) · doi:10.1117/3.2197756 · Cited by 1,400
A three‐dimensional statistical approach to improved image quality for multislice helical CT
Thibault, J., Sauer, K. D., Bouman, C. A., & Hsieh, J. (2007) · Medical Physics · doi:10.1118/1.2789499 · Cited by 937
Reduction of CT artifacts caused by metallic implants.
Kalender, W. A., Hebel, R., & Ebersberger, J. (1987) · Radiology · doi:10.1148/radiology.164.2.3602406 · Cited by 751
Compressed sensing based interior tomography
Yu, H., & Wang, G. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/9/014 · Cited by 519
Dual energy CT: preliminary observations and potential clinical applications in the abdomen
Graser, A., Johnson, T. R. C., Chandarana, H., & Macari, M. (2009) · European Radiology · doi:10.1007/s00330-008-1122-7 · Cited by 479
Multi–Detector Row CT Systems and Image-Reconstruction Techniques
Flohr, T. G., Schaller, S., Stierstorfer, K., Bruder, H., Ohnesorge, B. M., & Schoepf, U. J. (2005) · Radiology · doi:10.1148/radiol.2353040037 · Cited by 381
Metal streak artifacts in X-ray computed tomography: a simulation study
De Man, B., Nuyts, J., Dupont, P., Marchal, G., & Suetens, P. (1999) · IEEE Transactions on Nuclear Science · doi:10.1109/23.775600 · Cited by 311
Cited by
Withers, P. J., Bouman, C., Carmignato, S., Cnudde, V., Grimaldi, D., Hagen, C. K., Maire, E., Manley, M., Du Plessis, A., & Stock, S. R. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00015-4 · Cited by 1,079
Deep Learning Image Reconstruction for CT: Technical Principles and Clinical Prospects
Koetzier, L. R., Mastrodicasa, D., Szczykutowicz, T. P., van der Werf, N. R., Wang, A. S., Sandfort, V., van der Molen, A. J., Fleischmann, D., & Willemink, M. J. (2023) · Radiology · doi:10.1148/radiol.221257 · Cited by 427
Self-citationPorosity Measurements and Analysis for Metal Additive Manufacturing Process Control
Slotwinski, J. A., Garboczi, E. J., & Hebenstreit, K. M. (2014) · Journal of Research of the National Institute of Standards and Technology · doi:10.6028/jres.119.019 · Cited by 408
Laboratory x-ray micro-computed tomography: a user guideline for biological samples
du Plessis, A., Broeckhoven, C., Guelpa, A., & le Roux, S. G. (2017) · GigaScience · doi:10.1093/gigascience/gix027 · Cited by 374
TIGRE: a MATLAB-GPU toolbox for CBCT image reconstruction
Biguri, A., Dosanjh, M., Hancock, S., & Soleimani, M. (2016) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/2/5/055010 · Cited by 370
Challenges of Deep Learning in Medical Image Analysis—Improving Explainability and Trust
Dhar, T., Dey, N., Borra, S., & Sherratt, R. S. (2023) · IEEE Transactions on Technology and Society · doi:10.1109/tts.2023.3234203 · Cited by 309
Li, J., Tan, L., Liu, X., Cui, Z., Yang, X., Yeung, K. W. K., Chu, P. K., & Wu, S. (2017) · ACS Nano · doi:10.1021/acsnano.7b05620 · Cited by 300
Metal Artifact Reduction in CT: Where Are We After Four Decades?
Gjesteby, L., De Man, B., Jin, Y., Paganetti, H., Verburg, J., Giantsoudi, D., & Wang, G. (2016) · IEEE Access · doi:10.1109/access.2016.2608621 · Cited by 290
Successes and challenges in non-destructive testing of aircraft composite structures
TOWSYFYAN, H., BIGURI, A., BOARDMAN, R., & BLUMENSATH, T. (2020) · Chinese Journal of Aeronautics · doi:10.1016/j.cja.2019.09.017 · Cited by 272
Review of medical image quality assessment
Chow, L. S., & Paramesran, R. (2016) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.02.006 · Cited by 265
Multiscale X-ray tomography of cementitious materials: A review
Brisard, S., Serdar, M., & Monteiro, P. J. M. (2020) · Cement and Concrete Research · doi:10.1016/j.cemconres.2019.105824 · Cited by 260
Militello, C., Rundo, L., Toia, P., Conti, V., Russo, G., Filorizzo, C., Maffei, E., Cademartiri, F., La Grutta, L., Midiri, M., et al. (2019) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2019.103424 · Cited by 71
Computed tomography in paediatric heart disease
Mortensen, K. H., & Tann, O. (2018) · The British Journal of Radiology · doi:10.1259/bjr.20180201 · Cited by 24
Mikhael, E., Bouazza, A., Gates, W. P., & Haque, A. (2024) · Geotextiles and Geomembranes · doi:10.1016/j.geotexmem.2023.09.002 · Cited by 23
Metadata
- Authors
- Boas, F. E., & Fleischmann, D.
- Venue
- Imaging in Medicine
- Publisher
- OMICS Publishing Group
- Published
- 2012-04
- Volume
- 4
- Issue
- 2
- Pages
- 229-240
- ISSN
- 1755-5191 (ISSN-L)
- 1755-5205
- OpenAlex
- W2101891472
- Cited by
- 848
- References
- 28
- FWCI
- 12.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.