The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
CT artifacts: causes and reduction techniques
Abstract
Artifacts are commonly encountered in clinical computed tomography (CT), and may obscure or simulate pathology. There are many different types of CT artifacts, including noise, beam hardening, scatter, pseudoenhancement, motion, cone beam, helical, ring, and metal artifacts. We review the cause and appearance of each type of artifact, correct some popular misconceptions, and describe modern techniques for artifact reduction. Noise can be reduced using iterative reconstruction or by combining data from multiple scans. This enables lower radiation dose and higher resolution scans. Metal artifacts can also be reduced using iterative reconstruction, resulting in more accurate diagnosis. Dual and multi-energy (photon counting) CT can reduce beam hardening and provide better tissue contrast. Methods for reducing noise and out-of-field artifacts may enable ultra-high resolution limited-field-of-view imaging of tumors and other structures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Feldkamp, L. A., Davis, L. C., & Kress, J. W. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000612 · Cited by 6,319
Energy-selective reconstructions in X-ray computerised tomography
Alvarez, R. E., & Macovski, A. (1976) · Physics in Medicine & Biology · doi:10.1088/0031-9155/21/5/002 · Cited by 2,013
Artifacts in CT: Recognition and Avoidance
Barrett, J. F., & Keat, N. (2004) · RadioGraphics · doi:10.1148/rg.246045065 · Cited by 1,688
Computed Tomography: Principles, Design, Artifacts, and Recent Advances
Hsieh, J. (2015) · doi:10.1117/3.2197756 · Cited by 1,400
A three‐dimensional statistical approach to improved image quality for multislice helical CT
Thibault, J., Sauer, K. D., Bouman, C. A., & Hsieh, J. (2007) · Medical Physics · doi:10.1118/1.2789499 · Cited by 937
Reduction of CT artifacts caused by metallic implants.
Kalender, W. A., Hebel, R., & Ebersberger, J. (1987) · Radiology · doi:10.1148/radiology.164.2.3602406 · Cited by 751
Compressed sensing based interior tomography
Yu, H., & Wang, G. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/9/014 · Cited by 519
Dual energy CT: preliminary observations and potential clinical applications in the abdomen
Graser, A., Johnson, T. R. C., Chandarana, H., & Macari, M. (2009) · European Radiology · doi:10.1007/s00330-008-1122-7 · Cited by 479
Multi–Detector Row CT Systems and Image-Reconstruction Techniques
Flohr, T. G., Schaller, S., Stierstorfer, K., Bruder, H., Ohnesorge, B. M., & Schoepf, U. J. (2005) · Radiology · doi:10.1148/radiol.2353040037 · Cited by 381
Metal streak artifacts in X-ray computed tomography: a simulation study
De Man, B., Nuyts, J., Dupont, P., Marchal, G., & Suetens, P. (1999) · IEEE Transactions on Nuclear Science · doi:10.1109/23.775600 · Cited by 311
Evaluation of Two Iterative Techniques for Reducing Metal Artifacts in Computed Tomography
Boas, F. E., & Fleischmann, D. (2011) · Radiology · doi:10.1148/radiol.11101782 · Cited by 303
Self-citationFast Model-Based X-Ray CT Reconstruction Using Spatially Nonhomogeneous ICD Optimization
Yu, Z., Thibault, J.-B., Bouman, C. A., Sauer, K. D., & Hsieh, J. (2011) · IEEE Transactions on Image Processing · doi:10.1109/tip.2010.2058811 · Cited by 290
A Method for Correcting Bone Induced Artifacts in Computed Tomography Scanners
Joseph, P. M., & Spital, R. D. (1978) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197801000-00017 · Cited by 281 · cited 1×
“This can be addressed using iterative reconstruction [12, 13].”
BackgroundAn iterative approach to the beam hardening correction in cone beam CT
Hsieh, J., Molthen, R. C., Dawson, C. A., & Johnson, R. H. (2000) · Medical Physics · doi:10.1118/1.598853 · Cited by 280
Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering
Bal, M., & Spies, L. (2006) · Medical Physics · doi:10.1118/1.2218062 · Cited by 234
Rührnschopf, E., & Klingenbeck, K. (2011) · Medical Physics · doi:10.1118/1.3599033 · Cited by 232
Spiral and Multislice Computed Tomography of the Body
(2003) · Thieme eBooks · doi:10.1055/b-002-79382 · Cited by 219
The effects of scatter in x‐ray computed tomography
Joseph, P. M., & Spital, R. D. (1982) · Medical Physics · doi:10.1118/1.595111 · Cited by 211
Leschka, S., Stolzmann, P., Desbiolles, L., Baumueller, S., Goetti, R., Schertler, T., Scheffel, H., Plass, A., Falk, V., Feuchtner, G., et al. (2009) · European Radiology · doi:10.1007/s00330-009-1618-9 · Cited by 188
Rührnschopf and, E., & Klingenbeck, K. (2011) · Medical Physics · doi:10.1118/1.3589140 · Cited by 160
Iterative reconstruction algorithms in nuclear medicine
Vandenberghe, S., D’Asseler, Y., Rik Van De Walle, B., Kauppinen, T., Koole, M. J. B., Bouwens, L., Laere, K. V., Lemahieu, I. A., & Dierckx, R. A. (2001) · Computerized Medical Imaging and Graphics · doi:10.1016/s0895-6111(00)00060-4 · Cited by 129
Fast cone-beam CT image reconstruction using GPU hardware
Yan, G., Tian, J., Zhu, S., Dai, Y., & Qin, C. (2008) · Journal of X-Ray Science and Technology · doi:10.3233/xst-2008-00205 · Cited by 129
Mahabadi, A. A., Achenbach, S. S., Burgstahler, C., Dill, T., Fischbach, R., Knez, A., Moshage, W. E. L., Richartz, B. M., Ropers, D., Schröder, S., et al. (2010) · Radiology · doi:10.1148/radiol.10100140 · Cited by 107
Temporal resolution improvement in cardiac CT using PICCS (TRI‐PICCS): Performance studies
Tang, J., Hsieh, J., & Chen, G. (2010) · Medical Physics · doi:10.1118/1.3460318 · Cited by 72
Prell, D., Kyriakou, Y., Kachelrie�, M., & Kalender, W. A. (2010) · Investigative Radiology · doi:10.1097/rli.0b013e3181e94384 · Cited by 70
Boll, D. T., Patil, N. A., Paulson, E. K., et al. (2009) · Radiology · doi:10.1148/radiol.09090068 · Cited by 66
Watz, H., Breithecker, A., Rau, W. S., & Kriete, A. (2005) · Radiology · doi:10.1148/radiol.2363041142 · Cited by 63
Liu, X., Primak, A. N., Krier, J. D., Yu, L., Lerman, L. O., & McCollough, C. H. (2009) · Radiology · doi:10.1148/radiol.2531081677 · Cited by 39
Cited by
Withers, P. J., Bouman, C., Carmignato, S., Cnudde, V., Grimaldi, D., Hagen, C. K., Maire, E., Manley, M., Du Plessis, A., & Stock, S. R. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00015-4 · Cited by 1,079
Deep Learning Image Reconstruction for CT: Technical Principles and Clinical Prospects
Koetzier, L. R., Mastrodicasa, D., Szczykutowicz, T. P., van der Werf, N. R., Wang, A. S., Sandfort, V., van der Molen, A. J., Fleischmann, D., & Willemink, M. J. (2023) · Radiology · doi:10.1148/radiol.221257 · Cited by 427
Self-citationPorosity Measurements and Analysis for Metal Additive Manufacturing Process Control
Slotwinski, J. A., Garboczi, E. J., & Hebenstreit, K. M. (2014) · Journal of Research of the National Institute of Standards and Technology · doi:10.6028/jres.119.019 · Cited by 408
Laboratory x-ray micro-computed tomography: a user guideline for biological samples
du Plessis, A., Broeckhoven, C., Guelpa, A., & le Roux, S. G. (2017) · GigaScience · doi:10.1093/gigascience/gix027 · Cited by 374
TIGRE: a MATLAB-GPU toolbox for CBCT image reconstruction
Biguri, A., Dosanjh, M., Hancock, S., & Soleimani, M. (2016) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/2/5/055010 · Cited by 370
Metadata
- Authors
- Boas, F. E., & Fleischmann, D.
- Venue
- Imaging in Medicine
- Publisher
- OMICS Publishing Group
- Published
- 2012-04
- Volume
- 4
- Issue
- 2
- Pages
- 229-240
- ISSN
- 1755-5191 (ISSN-L)
- 1755-5205
- OpenAlex
- W2101891472
- Cited by
- 848
- References
- 28
- FWCI
- 12.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.