The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Nonparametric Analysis of Clustered ROC Curve Data
Abstract
Current methods for estimating the accuracy of diagnostic tests require independence of the test results in the sample. However, cases in which there are multiple test results from the same patient are quite common. In such cases, estimation and inference of the accuracy of diagnostic tests must account for intracluster correlation. In the present paper, the structural components method of DeLong, DeLong, and Clarke-Pearson (1988, Biometrics 44, 837-844) is extended to the estimation of the Receiver Operating Characteristics (ROC) curve area for clustered data, incorporating the concepts of design effect and effective sample size used by Rao and Scott (1992, Biometrics 48, 577-585) for clustered binary data. Results of a Monte Carlo simulation study indicate that the size of statistical tests that assume independence is inflated in the presence of intracluster correlation. The proposed method, on the other hand, appropriately handles a wide variety of intracluster correlations, e.g., correlations between true disease statuses and between test results. In addition, the method can be applied to both continuous and ordinal test results. A strategy for estimating sample size requirements for future studies using clustered data is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
The meaning and use of the area under a receiver operating characteristic (ROC) curve.
Hanley, J. A., & McNeil, B. J. (1982) · Radiology · doi:10.1148/radiology.143.1.7063747 · Cited by 21,856
On a Test of Whether one of Two Random Variables is Stochastically Larger than the Other
Mann, H. B., & Whitney, D. R. (1947) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177730491 · Cited by 14,320
Hanley, J. A., & McNeil, B. J. (1983) · Radiology · doi:10.1148/radiology.148.3.6878708 · Cited by 7,016
Basic principles of ROC analysis
Metz, C. E. (1978) · Seminars in Nuclear Medicine · doi:10.1016/s0001-2998(78)80014-2 · Cited by 6,026
Bamber, D. (1975) · Journal of Mathematical Psychology · doi:10.1016/0022-2496(75)90001-2 · Cited by 1,439
Dorfman, D. D., & Alf, E. (1969) · Journal of Mathematical Psychology · doi:10.1016/0022-2496(69)90019-4 · Cited by 874
A Simple Method for the Analysis of Clustered Binary Data
Rao, J. N. K., & Scott, A. J. (1992) · Biometrics · doi:10.2307/2532311 · Cited by 693
Metz, C. E., Wang, P.-L., & Kronman, H. B. (1984) · Information Processing in Medical Imaging · doi:10.1007/978-94-009-6045-9_25 · Cited by 356
A family of nonparametric statistics for comparing diagnostic markers with paired or unpaired data
WIEAND, S., GAIL, M. H., JAMES, B. R., & JAMES, K. L. (1989) · Biometrika · doi:10.1093/biomet/76.3.585 · Cited by 355
Cited by
The use of receiver operating characteristic curves in biomedical informatics
Lasko, T. A., Bhagwat, J. G., Zou, K. H., & Ohno-Machado, L. (2005) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2005.02.008 · Cited by 823
Detection of Macular Ganglion Cell Loss in Glaucoma by Fourier-Domain Optical Coherence Tomography
Tan, O., Chopra, V., Lu, A. T.-H., Schuman, J. S., Ishikawa, H., Wollstein, G., Varma, R., & Huang, D. (2009) · Ophthalmology · doi:10.1016/j.ophtha.2009.05.025 · Cited by 665
Simultaneous 68Ga-PSMA HBED-CC PET/MRI Improves the Localization of Primary Prostate Cancer
Eiber, M., Weirich, G., Holzapfel, K., Souvatzoglou, M., Haller, B., Rauscher, I., Beer, A. J., Wester, H.-J., Gschwend, J., Schwaiger, M., et al. (2016) · European Urology · doi:10.1016/j.eururo.2015.12.053 · Cited by 568
Obuchowski, N. A., & Bullen, J. A. (2018) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aab4b1 · Cited by 542
Self-citationVargas, H. A., Akin, O., Franiel, T., Mazaheri, Y., Zheng, J., Moskowitz, C., Udo, K., Eastham, J., & Hricak, H. (2011) · Radiology · doi:10.1148/radiol.11102066 · Cited by 402
Parameters behind “Nonparametric” Statistics: Kendall's tau, Somers’ D and Median Differences
Newson, R. (2002) · The Stata Journal: Promoting communications on statistics and Stata · doi:10.1177/1536867x0200200103 · Cited by 394
Akin, O., Sala, E., Moskowitz, C. S., Kuroiwa, K., Ishill, N. M., Pucar, D., Scardino, P. T., & Hricak, H. (2006) · Radiology · doi:10.1148/radiol.2392050949 · Cited by 379
Mapping of Macular Substructures with Optical Coherence Tomography for Glaucoma Diagnosis
Tan, O., Li, G., Lu, A. T.-H., Varma, R., & Huang, D. (2008) · Ophthalmology · doi:10.1016/j.ophtha.2007.08.011 · Cited by 361
Becker, A. S., Marcon, M., Ghafoor, S., Wurnig, M. C., Frauenfelder, T., & Boss, A. (2017) · Investigative Radiology · doi:10.1097/rli.0000000000000358 · Cited by 352
Christopher, M., Belghith, A., Bowd, C., Proudfoot, J. A., Goldbaum, M. H., Weinreb, R. N., Girkin, C. A., Liebmann, J. M., & Zangwill, L. M. (2018) · Scientific Reports · doi:10.1038/s41598-018-35044-9 · Cited by 328
Rectal Organoids Enable Personalized Treatment of Cystic Fibrosis
Berkers, G., van Mourik, P., Vonk, A. M., Kruisselbrink, E., Dekkers, J. F., de Winter-de Groot, K. M., Arets, H. G. M., Marck-van der Wilt, R. E. P., Dijkema, J. S., Vanderschuren, M. M., et al. (2019) · Cell Reports · doi:10.1016/j.celrep.2019.01.068 · Cited by 310
“As some patients were treated with two CFTR modifying treatments, we controlled for repeated measurments when calculating correlations and ROC-curves to evaluate a potential bias (Obuchowski, 1997; Lorenz, Datta and Harkema, 2011).”
MethodMossman, D. (1999) · Medical Decision Making · doi:10.1177/0272989x9901900110 · Cited by 302
Vande Casteele, N., Khanna, R., Levesque, B. G., Stitt, L., Zou, G. Y., Singh, S., Lockton, S., Hauenstein, S., Ohrmund, L., Greenberg, G. R., et al. (2015) · Gut · doi:10.1136/gutjnl-2014-307883 · Cited by 289
Methods for Calculating Sensitivity and Specificity of Clustered Data: A Tutorial
Genders, T. S. S., Spronk, S., Stijnen, T., Steyerberg, E. W., Lesaffre, E., & Hunink, M. G. M. (2012) · Radiology · doi:10.1148/radiol.12120509 · Cited by 258
Strigari, L., Sciuto, R., Rea, S., Carpanese, L., Pizzi, G., Soriani, A., Iaccarino, G., Benassi, M., Ettorre, G. M., & Maini, C. L. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.075861 · Cited by 239
Ji, S., Long, Q., Jeffrey Newport, D., Na, H., Knight, B., Zach, E. B., Morris, N. J., Kutner, M., & Stowe, Z. N. (2011) · Journal of Psychiatric Research · doi:10.1016/j.jpsychires.2010.05.017 · Cited by 128
Vignati, A., Mazzetti, S., Giannini, V, Russo, F., Bollito, E., Porpiglia, F., Stasi, M., & Regge, D. (2015) · Physics in Medicine & Biology · doi:10.1088/0031-9155/60/7/2685 · Cited by 122
“The 95% confidence interval of each ρ and AUC was estimated, and the AUC values of different ADC parameters were compared using the method proposed by Obuchowski (Obuchowski 1997) to take into account multiple lesions per patient.”
Homayounieh, F., Digumarthy, S., Ebrahimian, S., Rueckel, J., Hoppe, B. F., Sabel, B. O., Conjeti, S., Ridder, K., Sistermanns, M., Wang, L., et al. (2021) · JAMA Network Open · doi:10.1001/jamanetworkopen.2021.41096 · Cited by 113
Evaluating Imaging and Computer-aided Detection and Diagnosis Devices at the FDA
Gallas, B. D., Chan, H.-P., D’Orsi, C. J., Dodd, L. E., Giger, M. L., Gur, D., Krupinski, E. A., Metz, C. E., Myers, K. J., Obuchowski, N. A., et al. (2012) · Academic Radiology · doi:10.1016/j.acra.2011.12.016 · Cited by 81
Self-citationNatural history of superior mesenteric artery in-stent restenosis
Sorour, A. A., Dehaini, H., Alnahhal, K. I., Khalifeh, A., Rowse, J. W., Quatromoni, J. G., Caputo, F. J., Lyden, S. P., & Kirksey, L. (2024) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2023.11.035 · Cited by 6
Metadata
- Authors
- Obuchowski, N. A.
- Venue
- Biometrics
- Publisher
- JSTOR
- Published
- 1997-06
- Volume
- 53
- Issue
- 2
- Pages
- 567
- ISSN
- 0006-341X (ISSN-L)
- OpenAlex
- W2066063421
- Cited by
- 429
- References
- 15
- FWCI
- 4.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.