CoChat

Fully Integrated Artificial Pancreas in Type 1 Diabetes

Open access
Breton, Marc, Farret, Anne, Bruttomesso, Daniela, Anderson, Stacey, Magni, Lalo, Patek, Stephen, Dalla Man, Chiara, Place, Jerome, Demartini, Susan, Del Favero, Simone, Toffanin, Chiara, Hughes-Karvetski, Colleen, Dassau, Eyal, Zisser, Howard, Doyle, Francis J., De Nicolao, Giuseppe, Avogaro, Angelo, Cobelli, Claudio, Renard, Eric, Kovatchev, Boris, on behalf of The International Artificial Pancreas (iAP) Study Group · 2012 · Diabetes

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Abstract

Integrated closed-loop control (CLC), combining continuous glucose monitoring (CGM) with insulin pump (continuous subcutaneous insulin infusion [CSII]), known as artificial pancreas, can help optimize glycemic control in diabetes. We present a fundamental modular concept for CLC design, illustrated by clinical studies involving 11 adolescents and 27 adults at the Universities of Virginia, Padova, and Montpellier. We tested two modular CLC constructs: standard control to range (sCTR), designed to augment pump plus CGM by preventing extreme glucose excursions; and enhanced control to range (eCTR), designed to truly optimize control within near normoglycemia of 3.9-10 mmol/L. The CLC system was fully integrated using automated data transfer CGM→algorithm→CSII. All studies used randomized crossover design comparing CSII versus CLC during identical 22-h hospitalizations including meals, overnight rest, and 30-min exercise. sCTR increased significantly the time in near normoglycemia from 61 to 74%, simultaneously reducing hypoglycemia 2.7-fold. eCTR improved mean blood glucose from 7.73 to 6.68 mmol/L without increasing hypoglycemia, achieved 97% in near normoglycemia and 77% in tight glycemic control, and reduced variability overnight. In conclusion, sCTR and eCTR represent sequential steps toward automated CLC, preventing extremes (sCTR) and further optimizing control (eCTR). This approach inspires compelling new concepts: modular assembly, sequential deployment, testing, and clinical acceptance of custom-built CLC systems tailored to individual patient needs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/db11-1445

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Figures

FIG. 1. Design and profile of randomized clinical trials and timeline of inpatient admissions.
FIG. 1. Design and profile of randomized clinical trials and timeline of inpatient admissions.CC BY-NC-ND · PubMed Central
FIG. 2. Modular architecture of CTR.
FIG. 2. Modular architecture of CTR.CC BY-NC-ND · PubMed Central
FIG. 3. Primary outcomes of sCTR: Time in near normoglycemia (3.9–10 mmol/L), average glucose, intrasubject variability, and occurrence of hypoglycemia (hypo) during open- and closed-loop admissions, contrasted by overall and overnight periods. *P < 0.05. Open-loop CSII, gray bar; sCTR, black bar.
FIG. 3. Primary outcomes of sCTR: Time in near normoglycemia (3.9–10 mmol/L), average glucose, intrasubject variability, and occurrence of hypoglycemia (hypo) during open- and closed-loop admissions, contrasted by overall and overnight periods. *P < 0.05. Open-loop CSII, gray bar; sCTR, black bar.CC BY-NC-ND · PubMed Central
FIG. 4. Primary outcomes of eCTR: Time in near normoglycemia (3.9–10 mmol/L) and tight control (4.4–7.78 mmol/L), average glucose, and intrasubject variability during open- and closed-loop admissions, contrasted by overall and overnight periods. *P < 0.05. Open-loop CSII, gray bar; eCTR, black bar.
FIG. 4. Primary outcomes of eCTR: Time in near normoglycemia (3.9–10 mmol/L) and tight control (4.4–7.78 mmol/L), average glucose, and intrasubject variability during open- and closed-loop admissions, contrasted by overall and overnight periods. *P < 0.05. Open-loop CSII, gray bar; eCTR, black bar.CC BY-NC-ND · PubMed Central
FIG. 5. Mean (curves) and 25–75% quantiles (shaded areas) of plasma glucose for each algorithm comparing open-loop CSII and closed-loop admissions. Glycemic ranges are depicted by the bounds (plain: near normoglycemia; dotted: tight glucose control).
FIG. 5. Mean (curves) and 25–75% quantiles (shaded areas) of plasma glucose for each algorithm comparing open-loop CSII and closed-loop admissions. Glycemic ranges are depicted by the bounds (plain: near normoglycemia; dotted: tight glucose control).CC BY-NC-ND · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 34 references

Research works printed but not linked: 1

  1. Renard EM Farret A Place J Cobelli C Kovatchev BP Breton MD Closed-loop insulin delivery using subcutaneous infusion and glucose sensing, and equipped with a dedicated safety supervision algorithm, improves safety of glucose control in type 1 diabetes. Diabetologia 2010; 53(Suppl. 1): S25

Cited by

See all 354

Metadata

Authors
Breton, M., Farret, A., Bruttomesso, D., Anderson, S., Magni, L., Patek, S., Dalla Man, C., Place, J., Demartini, S., Del Favero, S., Toffanin, C., Hughes-Karvetski, C., Dassau, E., Zisser, H., Doyle, F. J., De Nicolao, G., Avogaro, A., Cobelli, C., Renard, E., Kovatchev, B., & on behalf of The International Artificial Pancreas (iAP) Study Group
Affiliations
  • University of Virginia (US)
  • Centre National de la Recherche Scientifique (FR)
  • University of Padua (IT)
  • University of Pavia (IT)
  • Department of Information Engineering, University of Padova, Padova, Italy
  • University Hospital of Montpellier, Department of Endocrinology, Diabetes, and Nutrition, INSERM Clinical Investigation Center 1001, Institute of Functional Genomics, CNRS UMR5203, INSERM U661, University of Montpellier, Montpellier, France
  • University of Virginia, Center for Diabetes Technology, Charlottesville, Virginia
  • University of California, Santa Barbara (US)
  • Department of Computer Engineering and System Sciences, University of Pavia, Pavia, Italy
Corresponding author
Breton, Marc
Venue
Diabetes
Published
2012-08-17
Volume
61
Issue
9
Pages
2230-2237
ISSN
  • 0012-1797 (ISSN-L)
  • 1939-327X
OpenAlex
W2145097544
Cited by
315
References
34
Citations by year
2026: 8 · 2025: 13 · 2024: 4 · 2023: 9 · 2022: 6 · 2021: 15 · 2020: 7 · 2019: 23 · 2018: 28 · 2017: 33 · 2016: 27 · 2015: 36 · 2014: 52 · 2013: 45 · 2012: 7
FWCI
35.94
Type
journal article
Language
en
Open access
Locations
  • Diabetes (publishedVersion, cc-by-nc-nd)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by-nc-nd)
  • PubMed Central (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • Padua Research Archive (University of Padova) (submittedVersion)
Funders
National Institute of Diabetes and Digestive and Kidney Diseases (R21DK085641, 5-R21-DK-85641)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Pancreatic function and diabetes
Keywords
artificial pancreas, feedback control, type 1 diabetes, continuous glucose monitoring, insulin pump therapy, glycemic control, hypoglycemia prevention, time in range, automated data transfer, adolescents and adults
MeSH terms
Adolescent, Adult, Algorithms, Automation, Blood Glucose, Computer Simulation, Diabetes Mellitus, Type 1, Humans, Hypoglycemic Agents, Insulin Infusion Systems, Middle Aged, Cross-Over Studies, Pancreas, Artificial

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.