Luijf, Yoeri M., DeVries, J. Hans, Zwinderman, Koos, Leelarathna, Lalantha, Nodale, Marianna, Caldwell, Karen, Kumareswaran, Kavita, Elleri, Daniela, Allen, Janet M., Wilinska, Malgorzata E., Evans, Mark L., Hovorka, Roman, Doll, Werner, Ellmerer, Martin, Mader, Julia K., Renard, Eric, Place, Jerome, Farret, Anne, Cobelli, Claudio, Del Favero, Simone, Dalla Man, Chiara, Avogaro, Angelo, Bruttomesso, Daniela, Filippi, Alessio, Scotton, Rachele, Magni, Lalo, Lanzola, Giordano, Di Palma, Federico, Soru, Paola, Toffanin, Chiara, De Nicolao, Giuseppe, Arnolds, Sabine, Benesch, Carsten, Heinemann, Lutz, on behalf of the AP@home Consortium · 2013 · Diabetes Care
Cited by 95

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To compare two validated closed-loop (CL) algorithms versus patient self-control with CSII in terms of glycemic control. RESEARCH DESIGN AND METHODS: This study was a multicenter, randomized, three-way crossover, open-label trial in 48 patients with type 1 diabetes mellitus for at least 6 months, treated with continuous subcutaneous insulin infusion. Blood glucose was controlled for 23 h by the algorithm of the Universities of Pavia and Padova with a Safety Supervision Module developed at the Universities of Virginia and California at Santa Barbara (international artificial pancreas [iAP]), by the algorithm of University of Cambridge (CAM), or by patients themselves in open loop (OL) during three hospital admissions including meals and exercise. The main analysis was on an intention-to-treat basis. Main outcome measures included time spent in target (glucose levels between 3.9 and 8.0 mmol/L or between 3.9 and 10.0 mmol/L after meals). RESULTS: Time spent in the target range was similar in CL and OL: 62.6% for OL, 59.2% for iAP, and 58.3% for CAM. While mean glucose level was significantly lower in OL (7.19, 8.15, and 8.26 mmol/L, respectively) (overall P = 0.001), percentage of time spent in hypoglycemia (<3.9 mmol/L) was almost threefold reduced during CL (6.4%, 2.1%, and 2.0%) (overall P = 0.001) with less time ≤2.8 mmol/L (overall P = 0.038). There were no significant differences in outcomes between algorithms. CONCLUSIONS: Both CAM and iAP algorithms provide safe glycemic control.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/dc12-1956

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

Metadata

Authors
Luijf, Y. M., DeVries, J. H., Zwinderman, K., Leelarathna, L., Nodale, M., Caldwell, K., Kumareswaran, K., Elleri, D., Allen, J. M., Wilinska, M. E., Evans, M. L., Hovorka, R., Doll, W., Ellmerer, M., Mader, J. K., Renard, E., Place, J., Farret, A., Cobelli, C., Del Favero, S., Dalla Man, C., Avogaro, A., Bruttomesso, D., Filippi, A., Scotton, R., Magni, L., Lanzola, G., Di Palma, F., Soru, P., Toffanin, C., De Nicolao, G., Arnolds, S., Benesch, C., Heinemann, L., & on behalf of the AP@home Consortium
Venue
Diabetes Care
Published
2013-11-13
Volume
36
Issue
12
Pages
3882-3887
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2159028135
Cited by
95
References
7
FWCI
13.21
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.