REPLACE-BG: A Randomized Trial Comparing Continuous Glucose Monitoring With and Without Routine Blood Glucose Monitoring in Adults With Well-Controlled Type 1 Diabetes
Open accessAbstract
OBJECTIVE: To determine whether the use of continuous glucose monitoring (CGM) without confirmatory blood glucose monitoring (BGM) measurements is as safe and effective as using CGM adjunctive to BGM in adults with well-controlled type 1 diabetes (T1D). RESEARCH DESIGN AND METHODS: A randomized noninferiority clinical trial was conducted at 14 sites in the T1D Exchange Clinic Network. Participants were ≥18 years of age (mean 44 ± 14 years), had T1D for ≥1 year (mean duration 24 ± 12 years), used an insulin pump, and had an HbA1c ≤9.0% (≤75 mmol/mL) (mean 7.0 ± 0.7% [53 ± 7.7 mmol/mol]); prestudy, 47% were CGM users. Participants were randomly assigned 2:1 to the CGM-only (n = 149) or CGM+BGM (n = 77) group. The primary outcome was time in range (70–180 mg/dL) over the 26-week trial, with a prespecified noninferiority limit of 7.5%. RESULTS: CGM use averaged 6.7 ± 0.5 and 6.8 ± 0.4 days/week in the CGM-only and CGM+BGM groups, respectively, over the 26-week trial. BGM tests per day (including the two required daily for CGM calibration) averaged 2.8 ± 0.9 and 5.4 ± 1.4 in the two groups, respectively (P < 0.001). Mean time in 70–180 mg/dL was 63 ± 13% at both baseline and 26 weeks in the CGM-only group and 65 ± 13% and 65 ± 11% in the CGM+BGM group (adjusted difference 0%; one-sided 95% CI −2%). No severe hypoglycemic events occurred in the CGM-only group, and one occurred in the CGM+BGM group. CONCLUSIONS: Use of CGM without regular use of confirmatory BGM is as safe and effective as using CGM with BGM in adults with well-controlled T1D at low risk for severe hypoglycemia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Numerous studies have demonstrated significant clinical benefits of CGM use in people with diabetes regardless of insulin delivery method (1-15).”
From Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range (2019) · cites this paper as [2]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“However, the increasing accuracy of the devices and at least one RCT comparing nonadjunctive to adjunctive use (191) has led the FDA to approve most current CGM devices for nonadjunctive use in the U.S.”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [191]
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Based on the results of multiple studies reporting a strong linear relationship between percent time in range (TIR) (70–180 mg/dL) and A1C in persons with T1D and T2D”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [154]
Experimental — accuracy not yet measuredIn the citing paper
“CGM systems are generally nonadjunctive, meaning they do not require BGM confirmation for treatment decisions like insulin dosing or treating hypoglycemia, except in certain clinical situations (see BLOOD GLUCOSE MONITORING, above) (44-46).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [44]
In the citing paper
“Some of these non-iCGM-approved CGM devices require additional user verification of blood glucose levels to be performed for making treatment decisions, termed adjunctive.”
From Importance of FDA-integrated continuous glucose monitors to ensure accuracy of continuous glucose monitoring (2025) · cites this paper as [12]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Miller, K. M., Foster, N. C., Beck, R. W., Bergenstal, R. M., DuBose, S. N., DiMeglio, L. A., Maahs, D. M., & Tamborlane, W. V. (2015) · Diabetes Care · doi:10.2337/dc15-0078 · Cited by 1,254
Self-citationEffectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Peoples, T., Perkins, B. A., Welsh, J. B., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1002853 · Cited by 894
Clarke, W. L., Cox, D. J., Gonder-Frederick, L. A., Julian, D., Schlundt, D., & Polonsky, W. (1995) · Diabetes Care · doi:10.2337/diacare.18.4.517 · Cited by 651 · cited 2×
“Exclusion criteria included the occurrence of a severe hypoglycemic event resulting in seizure or loss of consciousness in the past 3 years or an event without seizure or loss of consciousness requiring the assistance of another individual in the past 12 months, significant hypoglycemia unawareness based on the Clarke…”
BackgroundInfluentialFear of hypoglycemia: quantification, validation, and utilization
Cox, D. J., Irvine, A., Gonder-Frederick, L., Nowacek, G., & Butterfield, J. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.617 · Cited by 579 · cited 1×
“The following questionnaires were completed at baseline and 26weeks: the Diabetes Technology Questionnaire, which consists of 30 questions about diabetes self-treatment practices and the impact of living with diabetes on the individual (20), and the Hypoglycemia Fear Survey, which consists of 23 questions about the ef…”
MethodPickup, J. C., Freeman, S. C., & Sutton, A. J. (2011) · BMJ · doi:10.1136/bmj.d3805 · Cited by 541
Effect of Continuous Glucose Monitoring on Hypoglycemia in Type 1 Diabetes
Battelino, T., Phillip, M., Bratina, N., Nimri, R., Oskarsson, P., & Bolinder, J. (2011) · Diabetes Care · doi:10.2337/dc10-1989 · Cited by 496
Yeh, H.-C., Brown, T. T., Maruthur, N., Ranasinghe, P., Berger, Z., Suh, Y. D., Wilson, L. M., Haberl, E. B., Brick, J., Bass, E. B., et al. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-157-5-201209040-00508 · Cited by 493
The effect of continuous glucose monitoring in well-controlled type 1 diabetes
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) · Diabetes Care · doi:10.2337/dc09-0108 · Cited by 399
Peters, A. L., Ahmann, A. J., Battelino, T., Evert, A., Hirsch, I. B., Murad, M. H., Winter, W. E., & Wolpert, H. (2016) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2016-2534 · Cited by 250
Self-citation
Cited by
Sorted by citations
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237
“Numerous studies have demonstrated significant clinical benefits of CGM use in people with diabetes regardless of insulin delivery metho d (1-15).”
BackgroundSelf-citationContinuous glucose monitoring and metrics for clinical trials: an international consensus statement
Battelino, T., Alexander, C. M., Amiel, S. A., Arreaza-Rubin, G., Beck, R. W., Bergenstal, R. M., Buckingham, B. A., Carroll, J., Ceriello, A., Chow, E., et al. (2023) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(22)00319-9 · Cited by 831
Self-citation6. Glycemic Targets: Standards of Medical Care in Diabetes—2018
American Diabetes Association (2017) · Diabetes Care · doi:10.2337/dc18-s006 · Cited by 790
Glucose management indicator (GMI): a new term for estimating A1C from continuous glucose monitoring
Bergenstal, R. M., Beck, R. W., Close, K. L., Grunberger, G., Sacks, D. B., Kowalski, A., Brown, A. S., Heinemann, L., Aleppo, G., Ryan, D. B., et al. (2018) · Diabetes Care · doi:10.2337/dc18-1581 · Cited by 684
Self-citationBlonde, L., Umpierrez, G. E., Reddy, S. S., McGill, J. B., Berga, S. L., Bush, M., Chandrasekaran, S., DeFronzo, R. A., Einhorn, D., Galindo, R. J., et al. (2022) · Endocrine Practice · doi:10.1016/j.eprac.2022.08.002 · Cited by 507
Self-citationThe relationships between time in range, hyperglycemia metrics, and HbA1c
Beck, R. W., Bergenstal, R. M., Cheng, P., Kollman, C., Carlson, A. L., Johnson, M. L., & Rodbard, D. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818822496 · Cited by 479
Self-citationCappon, G., Vettoretti, M., Sparacino, G., & Facchinetti, A. (2019) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2019.0121 · Cited by 477
The fallacy of average: how using HbA1c alone to assess glycemic control can be misleading
Beck, R. W., Connor, C. G., Mullen, D. M., Wesley, D. M., & Bergenstal, R. M. (2017) · Diabetes Care · doi:10.2337/dc17-0636 · Cited by 477
Self-citationThe relationship of hemoglobin A1C to time-in-range in patients with diabetes
Vigersky, R. A., & McMahon, C. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0310 · Cited by 464
Pratley, R. E., Kanapka, L. G., Rickels, M. R., Ahmann, A., Aleppo, G., Beck, R., Bhargava, A., Bode, B. W., Carlson, A., Chaytor, N. S., et al. (2020) · JAMA · doi:10.1001/jama.2020.6928 · Cited by 375
Self-citation7. Diabetes Technology: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s007 · Cited by 358
7. Diabetes Technology: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s007 · Cited by 348
Self-citationSacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Diabetes Care · doi:10.2337/dci23-0036 · Cited by 351
7. Diabetes Technology: Standards of Care in Diabetes — 2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s007 · Cited by 301
Self-citationKlonoff, D. C., Wang, J., Rodbard, D., Kohn, M. A., Li, C., Liepmann, D., Kerr, D., Ahn, D., Peters, A. L., Umpierrez, G. E., et al. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221085273 · Cited by 295
Self-citationGrunberger, G., Sherr, J., Allende, M., Blevins, T., Bode, B., Handelsman, Y., Hellman, R., Lajara, R., Roberts, V. L., Rodbard, D., et al. (2021) · Endocrine Practice · doi:10.1016/j.eprac.2021.04.008 · Cited by 288
Self-citation7. Diabetes Technology: Standards of Care in Diabetes—2024
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Hilliard, M. E., Johnson, E. L., Khunti, K., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s007 · Cited by 281
Self-citationOptimal Sampling Duration for Continuous Glucose Monitoring to Determine Long-Term Glycemic Control
Riddlesworth, T. D., Beck, R. W., Gal, R. L., Connor, C. G., Bergenstal, R. M., Lee, S., & Willi, S. M. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0455 · Cited by 266
Self-citation7. Diabetes Technology: Standards of Medical Care in Diabetes—2020
American Diabetes Association (2019) · Diabetes Care · doi:10.2337/dc20-s007 · Cited by 261
Advances in technology for management of type 1 diabetes
Beck, R. W., Bergenstal, R. M., Laffel, L. M., & Pickup, J. C. (2019) · The Lancet · doi:10.1016/s0140-6736(19)31142-0 · Cited by 242
Self-citationNimri, R., Battelino, T., Laffel, L. M., Slover, R. H., Schatz, D., Weinzimer, S. A., Dovc, K., Danne, T., Phillip, M., NextDREAM Consortium, et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-1045-7 · Cited by 242
7. Diabetes Technology: Standards of Medical Care in Diabetes—2021
American Diabetes Association (2021) · Diabetes Care · doi:10.2337/dc21-s007 · Cited by 202
Measures of Accuracy for Continuous Glucose Monitoring and Blood Glucose Monitoring Devices
Freckmann, G., Pleus, S., Grady, M., Setford, S., & Levy, B. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818812062 · Cited by 202
Clinical Implications of Real-time and Intermittently Scanned Continuous Glucose Monitoring
Edelman, S. V., Argento, N. B., Pettus, J., & Hirsch, I. B. (2018) · Diabetes Care · doi:10.2337/dc18-1150 · Cited by 209
Self-citationISPAD Clinical Practice Consensus Guidelines 2018: diabetes technologies
Sherr, J. L., Tauschmann, M., Battelino, T., de Bock, M., Forlenza, G., Roman, R., Hood, K. K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12731 · Cited by 197
“Some apps such as Calorie King and My Fitness Pal are general health apps that provide information beneficial to patients with T1D.”
MethodInfluentialContinuous glucose monitoring: A review of the evidence in type 1 and 2 diabetes mellitus
Lin, R., Brown, F., James, S., Jones, J., & Ekinci, E. (2021) · Diabetic Medicine · doi:10.1111/dme.14528 · Cited by 197
Advances in Biosensors for Continuous Glucose Monitoring Towards Wearables
Johnston, L., Wang, G., Hu, K., Qian, C., & Liu, G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.733810 · Cited by 199
7. Diabetes Technology: Standards of Medical Care in Diabetes—2019
American Diabetes Association (2019) · Diabetes Care · doi:10.2337/dc19-s007 · Cited by 179
Clinical Use of Continuous Glucose Monitoring in Adults with Type 2 Diabetes
Carlson, A. L., Mullen, D. M., & Bergenstal, R. M. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0024 · Cited by 181
Self-citationAlva, S., Bailey, T., Brazg, R., Budiman, E. S., Castorino, K., Christiansen, M. P., Forlenza, G., Kipnes, M., Liljenquist, D. R., & Liu, H. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820958754 · Cited by 164
Technology in the management of type 1 diabetes mellitus — current status and future prospects
Tauschmann, M., & Hovorka, R. (2018) · Nature Reviews Endocrinology · doi:10.1038/s41574-018-0044-y · Cited by 165
Sacks, D. B., Arnold, M. A., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Clinical Chemistry · doi:10.1093/clinchem/hvad080 · Cited by 164
Phillip, M., Bergenstal, R. M., Close, K. L., Danne, T., Garg, S. K., Heinemann, L., Hirsch, I. B., Kovatchev, B. P., Laffel, L. M., Mohan, V., et al. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0375 · Cited by 135
Self-citationImproving the clinical value and utility of CGM systems: issues and recommendations
Petrie, J. R., Peters, A. L., Bergenstal, R. M., Holl, R. W., Fleming, G. A., & Heinemann, L. (2017) · Diabetologia · doi:10.1007/s00125-017-4463-4 · Cited by 143
Self-citationContinuous glucose monitoring: The achievement of 100 years of innovation in diabetes technology
Galindo, R. J., & Aleppo, G. (2020) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2020.108502 · Cited by 144
Self-citationImproving the Clinical Value and Utility of CGM Systems: Issues and Recommendations
Petrie, J. R., Peters, A. L., Bergenstal, R. M., Holl, R. W., Fleming, G. A., & Heinemann, L. (2017) · Diabetes Care · doi:10.2337/dci17-0043 · Cited by 135
Self-citationAleppo, G., Laffel, L. M., Ahmann, A., Hirsch, I. B., Kruger, D. F., Peters, A. L., Weinstock, R. S., & Harris, D. R. (2017) · Journal of the Endocrine Society · doi:10.1210/js.2017-00388 · Cited by 129
Self-citationContinuous Glucose Monitoring: A Brief Review for Primary Care Practitioners
Ajjan, R., Slattery, D., & Wright, E. E. (2019) · Advances in Therapy · doi:10.1007/s12325-019-0870-x · Cited by 133
Wan, W., Skandari, M. R., Minc, A., Nathan, A. G., Winn, A. N., Zarei, P., O’Grady, M. J., & Huang, E. S. (2018) · Diabetes Care · doi:10.2337/dc17-1821 · Cited by 126
Peralta, F. G., Choudhary, P., Cosson, E., Irace, C., Rami-Merhar, B. M., & Seibold, A. (2022) · Diabetes Obesity and Metabolism · doi:10.1111/dom.14638 · Cited by 120
Vettoretti, M., Facchinetti, A., Sparacino, G., & Cobelli, C. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2746340 · Cited by 110
Ajjan, R., Cummings, M. H., Jennings, P. L., Leelarathna, L., Rayman, G. A., & Wilmot, E. G. (2018) · Diabetes and Vascular Disease Research · doi:10.1177/1479164118756240 · Cited by 111
Bergenstal, R. M., Layne, J. E., Zisser, H., Gabbay, R. A., Barleen, N. A., Lee, A. A., Majithia, A. R., Parkin, C. G., & Dixon, R. F. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0396 · Cited by 110
Self-citationJohnson, M. L., Martens, T. W., Criego, A. B., Carlson, A. L., Simonson, G. D., & Bergenstal, R. M. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0034 · Cited by 106
Self-citationType 2 Diabetes and the Use of Real-Time Continuous Glucose Monitoring
Jackson, M. A., Ahmann, A., & Shah, V. N. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0007 · Cited by 106
Self-citationISPAD Clinical Practice Consensus Guidelines 2022: Diabetes technologies: Glucose monitoring
Tauschmann, M., Forlenza, G. P., Hood, K. K., Cardona‐Hernandez, R., Giani, E., Hendrieckx, C., DeSalvo, D. J., Laffel, L. M., Saboo, B., Wheeler, B. J., et al. (2022) · Pediatric Diabetes · doi:10.1111/pedi.13451 · Cited by 123
Yoo, J. H., Choi, M. S., Ahn, J., Park, S. W., Kim, Y., Hur, K. Y., Jin, S., Kim, G., & Kim, J. H. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0499 · Cited by 102
How Can We Realize the Clinical Benefits of Continuous Glucose Monitoring?
Ajjan, R. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0021 · Cited by 104
Approach to Using Trend Arrows in the FreeStyle Libre Flash Glucose Monitoring Systems in Adults
Kudva, Y. C., Ahmann, A., Bergenstal, R. M., Gavin, J. R., Kruger, D. F., Midyett, L. K., Miller, E. M., & Harris, D. R. (2018) · Journal of the Endocrine Society · doi:10.1210/js.2018-00294 · Cited by 99
Self-citationHbA1c and Glucose Management Indicator Discordance: A Real-World Analysis
Perlman, J. E., Gooley, T. A., MCNULTY, B. K., Meyers, J., & Hirsch, I. B. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0501 · Cited by 101
Self-citationTime in Range from Continuous Glucose Monitoring: A Novel Metric for Glycemic Control
Yoo, J. H., & Kim, J. H. (2020) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2020.0257 · Cited by 98
Clinical Use of Continuous Glucose Monitoring in Adults with Type 1 Diabetes
Slattery, D., & Choudhary, P. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0051 · Cited by 87
Yoo, J. H., & Kim, J. H. (2023) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2022.0271 · Cited by 96
“Thus, in 2016, the FDA approved this as a non-adjunctive device that could replace fingerstick glucose monitoring when making treatment decisions [7,8].”
BackgroundAktürk, H. K., Agarwal, S., Hoffecker, L., & Shah, V. N. (2021) · Diabetes Care · doi:10.2337/dc20-3063 · Cited by 81
Self-citationKanbour, S., Jones, M., Abusamaan, M. S., NASS, C. M., Everett, E. M., Wolf, R. M., Sidhaye, A. R., & Mathioudakis, N. N. (2022) · Diabetes Care · doi:10.2337/dc22-1055 · Cited by 88
Jaloli, M., & Cescon, M. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221092785 · Cited by 85
Lin, Y. K., Fisher, S. J., & Pop‐Busui, R. (2020) · Journal of Diabetes Investigation · doi:10.1111/jdi.13290 · Cited by 82
Self-citationChampakanath, A., Akturk, H. K., Alonso, G. T., Snell-Bergeon, J. K., & Shah, V. N. (2022) · Diabetes Care · doi:10.2337/dc21-2004 · Cited by 76
Self-citationLing, J., Ng, J. K., Chan, J. C. N., & Chow, E. (2022) · Frontiers in Endocrinology · doi:10.3389/fendo.2022.869899 · Cited by 82
Clinical Opportunities for Continuous Biosensing and Closed-Loop Therapies
Li, J., Liang, J., Laken, S. J., Langer, R., & Traverso, G. (2020) · Trends in Chemistry · doi:10.1016/j.trechm.2020.02.009 · Cited by 74
Bruttomesso, D., Laviola, L., Avogaro, A., Bonora, E., Prato, S. D., Frontoni, S., Orsi, E., Rabbone, I., Sesti, G., & Purrello, F. (2019) · Nutrition Metabolism and Cardiovascular Diseases · doi:10.1016/j.numecd.2019.01.018 · Cited by 74
Reddy, N., Verma, N., & Dungan, K. M. (2020) · MDText.com, Inc. eBooks · Cited by 68
Real-World Evidence and Glycemic Improvement Using Dexcom G6 Features
Aktürk, H. K., Dowd, R., Shankar, K., & Derdzinski, M. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0654 · Cited by 67
Expanding the Role of Continuous Glucose Monitoring in Modern Diabetes Care Beyond Type 1 Disease
Klupa, T., Czupryniak, L., Dzida, G. J., Fichna, P., Jarosz-Chobot, P. A., Gumprecht, J., Myśliwiec, M., Szadkowska, A., Bomba-Opon, D. A., Czajkowski, K., et al. (2023) · Diabetes Therapy · doi:10.1007/s13300-023-01431-3 · Cited by 89
Mulinacci, G., Alonso, G. T., Snell-Bergeon, J. K., & Shah, V. N. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0257 · Cited by 66
Self-citationTime in range centered diabetes care
Dovč, K., & Battelino, T. (2021) · Clinical Pediatric Endocrinology · doi:10.1297/cpe.30.1 · Cited by 66
Aleppo, G., & Webb, K. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818813581 · Cited by 67
Self-citationFreckmann, G., Link, M., Pleus, S., Westhoff, A., Kamecke, U., & Haug, C. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0105 · Cited by 64
“For DG5, results based on the LOCF approach were slightly higher (i.e., worse) than using interpolated data.”
InfluentialSelecting the Appropriate Continuous Glucose Monitoring System – a Practical Approach
Adolfsson, P., Parkin, C. G., Thomas, A., & Krinelke, L. (2018) · touchREVIEWS in Endocrinology · doi:10.17925/ee.2018.14.1.24 · Cited by 65
Associations between HbA1c and continuous glucose monitoring‐derived glycaemic variables
Hirsch, I. B., Welsh, J. B., Calhoun, P. M., Puhr, S., Walker, T. C., & Price, D. A. (2019) · Diabetic Medicine · doi:10.1111/dme.14065 · Cited by 63
Self-citationThe Glucose Management Indicator: Time to Change Course?
Selvin, E. (2024) · Diabetes Care · doi:10.2337/dci23-0086 · Cited by 67
Khokhar, P. B., Gravino, C., & Palomba, F. (2024) · Artif. Intell. Medicine · doi:10.1016/j.artmed.2025.103132 · Cited by 63
Glucose Transformer: Forecasting Glucose Level and Events of Hyperglycemia and Hypoglycemia
Lee, S.-M., Kim, D.-Y., & Woo, J. (2023) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2023.3236822 · Cited by 64
“The training sample was expanded to include CGM data from 226 type 1 diabetes patients for more accurate model training [41].”
MethodImproving patient self-care using diabetes technologies
Alcántara-Aragón, V. (2019) · Therapeutic Advances in Endocrinology and Metabolism · doi:10.1177/2042018818824215 · Cited by 53
Wilmot, E. G., Lumb, A. N., Hammond, P. J., Murphy, H. R., SCOTT, E. M., Gibb, F. W., Platts, J. K., & Choudhary, P. (2020) · Diabetic Medicine · doi:10.1111/dme.14433 · Cited by 54
Karakus, K. E., Akturk, H. K., Alonso, G. T., Snell-Bergeon, J. K., & Shah, V. N. (2023) · Diabetes Care · doi:10.2337/dc23-0495 · Cited by 52
Self-citationTechnology Integration: The Role of the Diabetes Care and Education Specialist in Practice
Isaacs, D. M., Cox, C. E., Schwab, K., Oser, T. K., RINKER, J. K., Mason, M. J., Greenwood, D. A., & Albanese-O’Neill, A. (2020) · The Science of Diabetes Self-Management and Care · doi:10.1177/0145721720935123 · Cited by 54
Monitoring of Pediatric Type 1 Diabetes
Marks, B. E., & Wolfsdorf, J. I. (2020) · Frontiers in Endocrinology · doi:10.3389/fendo.2020.00128 · Cited by 55
Eichenlaub, M., Pleus, S., Rothenbühler, M., Bailey, T. S., Bally, L., Brazg, R., Bruttomesso, D., Diem, P., Boija, E. E., Fokkert, M. J., et al. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0465 · Cited by 51
The History, Evolution and Future of Continuous Glucose Monitoring (CGM)
Bender, C., Vestergaard, P., & Cichosz, S. L. (2025) · Diabetology · doi:10.3390/diabetology6030017 · Cited by 43
Aleppo, G., & Webb, K. M. (2018) · Endocrine Practice · doi:10.4158/ep-2018-0097 · Cited by 45
Self-citationRodbard, D. (2022) · Diabetes Obesity and Metabolism · doi:10.1111/dom.14906 · Cited by 45
Diabetes Technology Use in Adults with Type 1 and Type 2 Diabetes
Kravarusic, J., & Aleppo, G. (2019) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2019.10.006 · Cited by 46
Self-citationHerrero, P., Alalitei, A., Reddy, M., Georgiou, P., & Oliver, N. S. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0387 · Cited by 44
Continuous Glucose Monitoring for Prediabetes: What Are the Best Metrics?
Zahalka, S. J., Galindo, R. J., Shah, V. N., & Wang, C. C. L. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241242487 · Cited by 53
Self-citationCichosz, S. L., Jensen, M. H., & Olesen, S. S. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0532 · Cited by 42
Role of continuous glucose monitoring in the management of glycogen storage disorders
Herbert, M., Pendyal, S., Rairikar, M. V., Halaby, C. A., Benjamin, R. W., & Kishnani, P. S. (2018) · Journal of Inherited Metabolic Disease · doi:10.1007/s10545-018-0200-5 · Cited by 42
“Trials in diabetic populations have shown its utility in improving glycemic control, as evidenced by reduction in glycosylated hemoglobin (HbA1c) and preventing hypo- and hyperglycemic episodes (Beck et al 2017; Spaic et al 2017; Lind et al 2017; Aleppo et al 2017).”
BackgroundPeeks, F., Hoogeveen, I. J., Feldbrugge, R. L., Burghard, R., de Boer, F., Fokkert‐Wilts, M. J., van der Klauw, M. M., Oosterveer, M. H., & Derks, T. G. J. (2021) · Journal of Inherited Metabolic Disease · doi:10.1002/jimd.12383 · Cited by 42
Montaser, E., Fabris, C., & Kovatchev, B. P. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0104 · Cited by 44
Emerging Diabetes Technologies: Continuous Glucose Monitors/Artificial Pancreases
ALMURASHI, A. M., Rodriguez, E., & Garg, S. K. (2023) · Journal of the Indian Institute of Science · doi:10.1007/s41745-022-00348-3 · Cited by 55
Cichosz, S. L., Jensen, M. H., & Hejlesen, O. K. (2021) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2021.104472 · Cited by 42
Avari, P., Uduku, C., George, D., Herrero, P., Reddy, M., & Oliver, N. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0276 · Cited by 40
Choudhary, P., Bellido, V., Graner, M., Altpeter, B., Cicchetti, A., Durand‐Zaleski, I., & Kristensen, F. B. (2021) · Diabetes Therapy · doi:10.1007/s13300-021-01132-9 · Cited by 43
Prabhu Navis, J., Leelarathna, L., Mubita, W., Urwin, A., Rutter, M. K., Schofield, J., & Thabit, H. (2021) · Acta Diabetologica · doi:10.1007/s00592-020-01614-5 · Cited by 39
Friedman, J. G., Cardona, Z., Szmuilowicz, E. D., & Aleppo, G. (2023) · Pharmacogenomics and Personalized Medicine · doi:10.2147/pgpm.s374663 · Cited by 43
Self-citationNew and Emerging Technologies in Type 1 Diabetes
Sherwood, J. S., Russell, S. J., & Putman, M. S. (2020) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2020.07.006 · Cited by 46
Penalty weighted glucose prediction models could lead to better clinically usage
Cichosz, S. L., Kronborg, T., Jensen, M. H., & Hejlesen, O. K. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.104865 · Cited by 37
Layne, J. E., Jepson, L. H., Carite, A. M., Parkin, C. G., & Bergenstal, R. M. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2024.0197 · Cited by 37
Self-citationIdentifying the deficiencies of currently available CGM to improve uptake and benefit
Barnard‐Kelly, K. D., Martínez‐Brocca, M. A., Glatzer, T., & Oliver, N. (2024) · Diabetic Medicine · doi:10.1111/dme.15338 · Cited by 37
Klonoff, D. C., Gabbay, M., Moon, S. J., & Wilmot, E. G. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241250357 · Cited by 36
“12-14 Many but not all CGM systems are nonadjunctive.”
Metadata
- Authors
- Aleppo, G., Ruedy, K. J., Riddlesworth, T. D., Kruger, D. F., Peters, A. L., Hirsch, I., Bergenstal, R. M., Toschi, E., Ahmann, A. J., Shah, V. N., Rickels, M. R., Bode, B. W., Philis-Tsimikas, A., Pop-Busui, R., Rodriguez, H., Eyth, E., Bhargava, A., Kollman, C., Beck, R. W., & for the REPLACE-BG Study Group
- Affiliations
- Northwestern University (US)
- Jaeb Center for Health Research (US)
- Henry Ford Health (US)
- University of Southern California (US)
- University of Washington (US)
- Park Nicollet Health Services (US)
- Joslin Diabetes Center (US)
- Oregon Health & Science University (US)
- Barbara Davis Center for Childhood Diabetes, Aurora, CO
- University of Pennsylvania (US)
- Atlanta Diabetes Associates (US)
- Scripps Whittier Diabetes Institute, La Jolla, CA
- University of Michigan, Ann Arbor, MI
- University of South Florida (US)
- Iowa Diabetes and Endocrinology Research Center (US)
- Corresponding author
- Riddlesworth, Tonya D.
- ORCID
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2017-02-16
- Volume
- 40
- Issue
- 4
- Pages
- 538-545
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- PMC
- PMC5864100
- OpenAlex
- W2589083807
- Semantic Scholar
- 90d778291a6be773ec0116f890b79ecf1b9a36bb
- Cited by
- 329
- References
- 25
- Citations by year
- 2026: 30 · 2025: 27 · 2024: 38 · 2023: 43 · 2022: 37 · 2021: 36 · 2020: 39 · 2019: 27 · 2018: 31 · 2017: 19
- FWCI
- 25.06
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Diabetes Care (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Funders
- Leona M. and Harry B. Helmsley Charitable Trust
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- continuous glucose monitoring, type 1 diabetes, blood glucose monitoring, time in range, insulin pump therapy, hypoglycemia, glycemic control, non-inferiority, adults
- MeSH terms
- Adult, Aged, Blood Glucose, Diabetes Mellitus, Type 1, Female, Glycated Hemoglobin, Humans, Insulin Infusion Systems, Male, Middle Aged, Socioeconomic Factors, Blood Glucose Self-Monitoring, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review