Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 293

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Noninvasive Blood Glucose Monitoring With Optical Coherence Tomography

Open access
Larin, Kirill V., Eledrisi, Mohsen S., Motamedi, Massoud, Esenaliev, Rinat O. · 2002 · Diabetes Care

Abstract

OBJECTIVE—To study the feasibility of noninvasive blood glucose monitoring using optical coherence tomography (OCT) technique in healthy volunteers. RESEARCH DESIGN AND METHODS—An OCT system with the wavelength of 1,300 nm was used in 15 healthy subjects in 18 clinical experiments. Standard oral glucose tolerance tests were performed to induce changes in blood glucose concentration. Blood samples were taken from the right arm vein every 5 or 15 min. OCT images were taken every 10–20 s from the left forearm over a total period of 3 h. The slope of the signals was calculated at the depth of 200–600 μm from the skin surface. RESULTS—A total of 426 blood samples and 8,437 OCT images and signals were collected and analyzed in these experiments. There was a good correlation between changes in the slope of noninvasively measured OCT signals and blood glucose concentrations throughout the duration of the experiments. The slope of OCT signals changed significantly (up to 2.8% per 10 mg/dl) with variation of plasma glucose values. The good correlation obtained between the OCT signal slope and blood glucose concentration is due to the coherent detection of backscattered photons, which allows measurements of OCT signal from a specific tissue layer without unwanted signal from other tissue layers. CONCLUSIONS—This pilot study demonstrated the capability of the OCT technique to monitor blood glucose concentration noninvasively in human subjects. Further studies with a larger number of subjects including diabetic subjects are planned to validate these preliminary results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/diacare.25.12.2263

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 1

  1. Larin KV, Larina IV, Motamedi M, Gelikonov V, Kuranov R, Esenaliev RO: Potential application of optical coherence tomography for non-invasive monitoring of glucose concentration. Prog Biomed Optics Imag 2:83–90, 2001 · doi:10.1117/12.429342

Cited by

See all 293

Metadata

Authors
Larin, K. V., Eledrisi, M. S., Motamedi, M., & Esenaliev, R. O.
Venue
Diabetes Care
Published
2002-12-01
Volume
25
Issue
12
Pages
2263-2267
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2150894223
Cited by
293
References
19
FWCI
5.17
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.