The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Continuous Subcutaneous Insulin Infusion at 25 Years
Open accessAbstract
Continuous subcutaneous insulin infusion (CSII) is used in selected type 1 diabetic subjects to achieve strict blood glucose control. A quarter of a century after its introduction, world-wide use of CSII is increasing. We review the evidence base that justifies this increase, including effectiveness compared with modern intensified insulin injection regimens and concern about possible complications. Review of controlled trials shows that, in most patients, mean blood glucose concentrations and glycated hemoglobin percentages are either slightly lower or similar on CSII versus multiple insulin injections. However, hypoglycemia is markedly less frequent than during intensive injection therapy. Ketoacidosis occurs at the same rate. Nocturnal glycemic control is improved with insulin pumps, and automatic basal rate changes help to minimize a prebreakfast blood glucose increase (the “dawn phenomenon”) often seen with injection therapy. Patients with “brittle” diabetes characterized by recurrent ketoacidosis are often not improved by CSII, although there may be exceptions. We argue that explicit clinical indications for CSII are helpful; we suggest the principal indications for health service or health insurance–funded CSII should include frequent, unpredictable hypoglycemia or a marked dawn phenomenon, which persist after attempts to improve control with intensive insulin injection regimens. In any circumstances, candidates for CSII must be motivated, willing and able to undertake pump therapy, and adequately psychologically stable. Some diabetic patients with well-defined clinical problems are likely to benefit substantially from CSII and should not be denied a trial of the treatment. Their number is relatively small, as would therefore be the demand on funds set aside for this purpose.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pickup, J. C., & Williams, G. H. (1991) · Cited by 571
Self-citationContinuous subcutaneous insulin infusion: an approach to achieving normoglycaemia.
Pickup, J. C., Keen, H., Parsons, J. A., & Alberti, K. G. (1978) · BMJ · doi:10.1136/bmj.1.6107.204 · Cited by 563
Self-citationBoland, E. A., Grey, M., Oesterle, A., Fredrickson, L., & Tamborlane, W. V. (1999) · Diabetes Care · doi:10.2337/diacare.22.11.1779 · Cited by 432
Tamborlane, W. V., Sherwin, R. S., Genel, M., & Felig, P. (1979) · New England Journal of Medicine · doi:10.1056/nejm197903153001101 · Cited by 411
Insulin analogues and their potential in the management of diabetes mellitus
Bolli, G. B., Di Marchi, R. D., Park, G. D., Pramming, S., & Koivisto, V. A. (1999) · Diabetologia · doi:10.1007/s001250051286 · Cited by 349
Dahl-Jorgensen, K., Brinchmann-Hansen, O., Hanssen, K. F., Ganes, T., Kierulf, P., Smeland, E., Sandvik, L., & Aagenaes, O. (1986) · BMJ · doi:10.1136/bmj.293.6556.1195 · Cited by 329
Implementation of Treatment Protocols in the Diabetes Control and Complications Trial
Diabetes Control and Complications Trial Research Group (1995) · Diabetes Care · doi:10.2337/diacare.18.3.361 · Cited by 283
Insulin Lispro in CSII: Results of a Double-Blind Crossover Study
Zinman, B., Tildesley, H., Chiasson, J.-L., Tsui, E., & Strack, T. (1997) · Diabetes · doi:10.2337/diab.46.3.440 · Cited by 258
Bode, B. W., Steed, R. D., & Davidson, P. C. (1996) · Diabetes Care · doi:10.2337/diacare.19.4.324 · Cited by 257
Campbell, P. J., Bolli, G. B., Cryer, P. E., & Gerich, J. E. (1985) · New England Journal of Medicine · doi:10.1056/nejm198506063122302 · Cited by 218
Schmidt, M. I., Hadji-Georgopoulos, A., Rendell, M., Margolis, S., & Kowarski, A. (1981) · Diabetes Care · doi:10.2337/diacare.4.6.579 · Cited by 216
Mecklenburg, R. S. (1984) · JAMA · doi:10.1001/jama.252.23.3265 · Cited by 187
Schiffrin, A., & Belmonte, M. M. (1982) · Diabetes · doi:10.2337/diab.31.3.255 · Cited by 177
continuous Subcutaneous Insulin Infusion in the Treatment of Diabetes Mellitus
Pickup, J. C., Keen, H., Viberti, G. C., White, M. C., Kohner, E. M., Parsons, J. A., & Alerti, K. G. M. M. (1980) · Diabetes Care · doi:10.2337/diacare.3.2.290 · Cited by 175
Self-citationHanaire-Broutin, H., Melki, V, Bessières-Lacombe, S., & Tauber, J. P. (2000) · Diabetes Care · doi:10.2337/diacare.23.9.1232 · Cited by 174
Renner, R., Pfützner, A., Trautmann, M., Harzer, O., Sauter, K., & Landgraf, R. (1999) · Diabetes Care · doi:10.2337/diacare.22.5.784 · Cited by 168
Tamborlane, W., Sherwin, R., Genel, M., & Felig, P. (1979) · The Lancet · doi:10.1016/s0140-6736(79)92226-8 · Cited by 167
Melki, V., Renard, É., Lassmann-Vague, V., Boivin, S., Guerci, B., Hanaire, H. P., Bringer, J., Bélicar, P., Jeandidier, N., Meyer, L., et al. (1998) · Diabetes Care · doi:10.2337/diacare.21.6.977 · Cited by 137
Chantelau, E. A., Spraul, M., M�hlhauser, I., Gause, R., & Berger, M. (1989) · Diabetologia · doi:10.1007/bf00271261 · Cited by 121
Continuous Subcutaneous Infusion of Insulin in the Management of Diabetes Mellitus
Champion, M. C., Shepherd, G. A. A., Rodger, N. W., & Dupre, J. (1980) · Diabetes · doi:10.2337/diab.29.3.206 · Cited by 118
Clinical Use of the Insulin Infusion Pump in 100 Patients with Type I Diabetes
Mecklenburg, R. S., Benson, J. W., Becker, N. M., Brazel, P. L., Fredlund, P. N., Metz, R. J., Nielsen, R. L., Sannar, C., & Steenrod, W. J. (1982) · New England Journal of Medicine · doi:10.1056/nejm198208263070901 · Cited by 113
Bode, B. W., & Strange, P. (2001) · Diabetes Care · doi:10.2337/diacare.24.1.69 · Cited by 112
Coustan, D. R. (1986) · JAMA · doi:10.1001/jama.1986.03370050073024 · Cited by 111
Steno Study Group (1982) · The Lancet · doi:10.1016/s0140-6736(82)90377-4 · Cited by 108
Glycemic control in insulin-dependent diabetes mellitus
Reeves, M. L., Seigler, D. E., Ryan, E. A., & Skyler, J. S. (1982) · The American Journal of Medicine · doi:10.1016/0002-9343(82)90479-x · Cited by 105
Insulin pump therapy in Type 1 pediatric patients: now and into the year 2000
KAUFMAN, F. R., Halvorson, M., Miller, D., Mackenzie, M., Fisher, L. K., & Pitukcheewanont, P. (1999) · Diabetes/Metabolism Research and Reviews · Cited by 90
Perriello, G., Feo, P. D., Torlone, E., Fanelli, C. G., Santeusanio, F., Brunetti, P., & Bolli, G. B. (1990) · Diabetologia · doi:10.1007/bf00586461 · Cited by 90
The Etiology of Incapacitating, Brittle Diabetes
Schade, D. S., Drumm, D. A., Duckworth, W. C., & Eaton, R. P. (1985) · Diabetes Care · doi:10.2337/diacare.8.1.12 · Cited by 89
Home, P. D., Capaldo, B., Burrin, J., Worth, R., & Alberti, K. G. M. M. (1982) · Diabetes Care · doi:10.2337/diacare.5.5.466 · Cited by 75
Bending, J. J., Pickup, J. C., & KEEN, H. (1985) · The American Journal of Medicine · doi:10.1016/0002-9343(85)90518-2 · Cited by 66
Self-citationKanc, K., Janssen, M. M. J., Keulen, E. T. P., Jacobs, M., Popp‐Snijders, C., Snoek, F. J., & Heine, R. J. (1998) · Diabetologia · doi:10.1007/s001250050910 · Cited by 65
Francis, A. J., Home, P., Hanning, I., Alberti, K. G. M. M., & Tunbridge, W. M. G. (1983) · BMJ · doi:10.1136/bmj.286.6372.1173 · Cited by 62
Intensive Conventional and Insulin Pump Therapies in Adult Type I Diabetes
Nathan, D. M., LOU, P., & Avruch, J. (1982) · Annals of Internal Medicine · doi:10.7326/0003-4819-97-1-31 · Cited by 52
Pickup, J. C., Viberti, G. C., Bilous, R. W., KEEN, H., Alberti, K. G. M. M., Home, P. D., & Binder, C. (1982) · Diabetologia · doi:10.1007/bf00283748 · Cited by 47
Self-citationSevere hyperkalaemia and ketoacidosis during routine treatment with an insulin pump.
Knight, G. C., Jennings, A. M., Boulton, A. J. M., Tomlinson, S., & Ward, J. D. (1985) · BMJ · doi:10.1136/bmj.291.6492.371 · Cited by 44
Marshall, S. M., Home, P., Taylor, R., & Alberti, K. G. M. M. (1987) · Diabetic Medicine · doi:10.1111/j.1464-5491.1987.tb00922.x · Cited by 41
Intensified Insulin Therapy in the Type I Diabetic Adolescent: A Controlled Trial
Schiffrin, A., Desrosiers, M., Aleyassine, H., & Belmonte, M. M. (1984) · Diabetes Care · doi:10.2337/diacare.7.2.107 · Cited by 37
Saurbrey, N., Arnold‐Larsen, S., Møller‐Jensen, B., & Kuhl, C. K. (1988) · Diabetic Medicine · doi:10.1111/j.1464-5491.1988.tb00962.x · Cited by 37
Hypoglycemic Coma Associated with Subcutaneous Insulin Infusion by Portable Pump
Lock, D. R., & Rigg, L. A. (1981) · Diabetes Care · doi:10.2337/diacare.4.3.389 · Cited by 34
Human insulin analogue [LYS(B28), PRO(B29)]: the ideal pump insulin?
Schmauβ, S., König, A., & Landgraf, R. (1998) · Diabetic Medicine · Cited by 34
Clinical evidence: Glycaemic control in diabetes
Herman, W. H. (1999) · BMJ · doi:10.1136/bmj.319.7202.104 · Cited by 34
Insulin Pump Treatment for Recurrent Ketoacidosis in Adolescence
Blackett, P. R. (1995) · Diabetes Care · doi:10.2337/diacare.18.6.881 · Cited by 34
Complications of Insulin Pump Therapy: The Effect of Insulin Preparation
Mecklenburg, R. S., & Guinn, T. S. (1985) · Diabetes Care · doi:10.2337/diacare.8.4.367 · Cited by 33
Helve, E., Koivisto, V. A., Lehtonen, A., Pelkonen, R., Huttunen, J. K., & Nikkilä, E. A. (1987) · Acta Medica Scandinavica · doi:10.1111/j.0954-6820.1987.tb03360.x · Cited by 32
Jf, B., Nielsen, O. H., Pedersen, O. B., & Beck‐Nielsen, H. (1987) · PubMed · Cited by 32
Hanaire, H. P., Melki, V., Bessières-Lacombe, S., & Tauber, J.-P. (2000) · Cited by 27
Fui, S. N. T., Pickup, J. C., Bending, J. J., Collins, A. C. G., KEEN, H., & Dalton, N. R. (1986) · Diabetes Care · doi:10.2337/diacare.9.3.221 · Cited by 20
Self-citationInsulin pump treatment for diabetes: some questions can be answered already
Berger, M., Sonnenberg, G. E., & Chantelau, E. A. (1982) · Clinical Physiology · doi:10.1111/j.1475-097x.1982.tb00040.x · Cited by 19
The Pump Life: Patient Responses and Clinical and Technological Problems
Pickup, J. C., Sherwin, R. S., Tamborlane, W. V., Rizza, R. A., Service, F. J., & The Kroc Collaborative Study Group (1985) · Diabetes · doi:10.2337/diab.34.3.s37 · Cited by 15
Self-citationSchmitz, A., Christiansen, J. S., Ck, C., Hermansen, K., & Mogensen, C. E. (1989) · PubMed · Cited by 15
Cited by
Artificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
Continuous glucose monitoring and closed‐loop systems
Hovorka, R. (2006) · Diabetic Medicine · doi:10.1111/j.1464-5491.2005.01672.x · Cited by 443
Closed-loop insulin delivery from bench to clinical practice
Hovorka, R. (2011) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2011.32 · Cited by 342
Advances in transdermal insulin delivery
Zhang, Y., Yu, J., Kahkoska, A. R., Wang, J., Buse, J. B., & Gu, Z. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.12.006 · Cited by 325
Sensor-Augmented Insulin Pump Therapy: Results of the First Randomized Treat-to-Target Study
Hirsch, I. B., Abelseth, J., Bode, B. W., Fischer, J. S., Kaufman, F. R., Mastrototaro, J., Parkin, C. G., Wolpert, H. A., & Buckingham, B. A. (2008) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0068 · Cited by 297
Metadata
- Authors
- Pickup, J., & Keen, H.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2002-03-01
- Volume
- 25
- Issue
- 3
- Pages
- 593-598
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2108808416
- Cited by
- 397
- References
- 50
- FWCI
- 11.23
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.