Cited by 119Analog and Mixed-Signal Circuit DesignNeuroscience and Neural EngineeringRadio Frequency Integrated Circuit Design

An implantable 700μW 64-channel neuromodulation IC for simultaneous recording and stimulation with rapid artifact recovery

Open access
Johnson, Benjamin C., Gambini, Simone, Izyumin, Igor, Moin, Ali, Zhou, Andy, Alexandrov, George, Santacruz, Samantha R., Rabaey, Jan M. +2 more·2017·2017 Symposium on VLSI Circuits

Abstract

We present an 180nm HV CMOS IC for concurrent neural stimulation and recording that combines 64 low-noise recording front-ends and 4 independent stimulators multiplexed to any of the 64 channels. The stimulators have 5mA peak current, 12V compliance and dynamic power management to maximize efficiency. Co-design of the stimulation and recording subsystems resulted in 100mV of recording linear range, 70nV/rtHz noise, and a rapid 1ms (single-sample) artifact recovery during stimulation.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.23919/vlsic.2017.8008543

Cites

0 of 5 references verified0 citation errors · 5 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • A common solution is to prevent amplifier saturation via a wide linear input range.

    “A common solution is to prevent amplifier saturation via a wide linear input range [194].”
  • Adaptive filtering methods rely on the least-mean-squares (LMS) algorithm to implement infinite impulse response (IIR) and finite impulse response (FIR) digital filters to address and cancel out individual samples of artifacts.

    “Techniques such as adaptive filtering methods rely on the least-mean-squares (LMS) algorithm to implement infinite impulse response (IIR) and finite impulse response (FIR) digital filters to address and cancel out individual samples of artifacts [132], [194].”

    From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [194]

    The System Description and Measurements section describes rapid artifact recovery through the recording front-end’s linear range, reset switches, and stimulation charge balancing. Searches for LMS, adaptive filtering, FIR/IIR filters, and sample-by-sample artifact cancellation found no passage addressing the claimed method. No page numbers were provided in our copy. (LLM, conf=0.76)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

  • Untitled work

    shulyzki (2015) · IEEE TBioCAS

    Unresolved
  • Untitled work

    rhew (2014) · IEEE JSSC

    Unresolved
  • Untitled work

    lo (2016) · IEEE ISSCC

    Unresolved
  • Untitled work

    muller (2015) · IEEE JSSC

    Unresolved
  • Untitled work

    sun (2014) · Neurotherapeutics

    Unresolved

Flagged first, then by citations

5 of the 5 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Johnson, B. C., Gambini, S., Izyumin, I., Moin, A., Zhou, A., Alexandrov, G., Santacruz, S. R., Rabaey, J. M., Carmena, J. M., & Muller, R.
Affiliations
University of California, Berkeley (US)
Venue
2017 Symposium on VLSI Circuits
Publisher
IEEE
Published
2017-06
Pages
C48-C49
ISSN
2166-9600 (ISSN-L)
OpenAlex
W2742939082
Cited by
119
References
5
Citations by year
2026: 8 · 2025: 13 · 2024: 10 · 2023: 10 · 2022: 12 · 2021: 16 · 2020: 15 · 2019: 16 · 2018: 18 · 2017: 1
FWCI
27.15
Type
conference paper
Language
en
Open access
Locations
  • Symposium on VLSI Circuits (publishedVersion)
  • eScholarship (California Digital Library) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
Keywords
neurostimulation, artifact recovery, low-power CMOS, HV-CMOS, dynamic power management

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review