CoChat

Midnight salivary cortisol, measured by highly sensitive electrochemiluminescence immunoassay, for the diagnosis of Cushing’s syndrome

Open access
Yaneva, Maria, Kirilov, Georgi, Zacharieva, Sabina · 2009 · Open Medicine
Cited by 38

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

The aim of the present study is to evaluate the measurement of midnight salivary cortisol as a method of screening for Cushing’s syndrome (CS). Here we tested the performance of a highly sensitive electrochemiluminescence immunoassay (ECLIA) for midnight salivary cortisol measurement in an extensive clinical study (n=104). Three groups were investigated: 30 patients with CS, 34 with obesity and 40 healthy normal weight controls. All of them collected saliva samples at 24:00 h and urine samples over the same day (24 hour period). An electrochemiluminescence immunoassay was used to measure salivary cortisol. Mean midnight salivary cortisol in healthy volunteers, obese patients and patients with CS was 8.33 ± 3.62, 8.13 ± 4.47 and 33.11 ± 21.68 nmol/l, respectively. No significant difference was found between midnight salivary cortisol in healthy and obese subjects (P>0.05). In contrast, salivary cortisol at midnight was significantly higher in patients with CS (P<0.001) as compared to both other groups. The cut-off point of 14.2 nmol/l yielded a sensitivity of 93.3% and a specificity of 94.2% (AUCROC=0.984 ± 0.01(0.965-1.000). A strong positive correlation between midnight salivary cortisol and urinary free cortisol has been found in the CS group (r=0.686, P<0.0001). Our results demonstrate that measurement of midnight salivary cortisol could be successfully used as a first-line screening method for CS. Our data approve ECLIA as a simple, reliable and timesaving method for the assessment of salivary cortisol. Automated measurement of midnight salivary cortisol by ECLIA would facilitate the routine practice in the screening for CS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2478/s11536-009-0004-y

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 38

Metadata

Authors
Yaneva, M., Kirilov, G., & Zacharieva, S.
Venue
Open Medicine
Published
2009-02-11
Volume
4
Issue
1
Pages
59-64
ISSN
  • 1895-1058 (ISSN-L)
  • 2391-5463
OpenAlex
W2022896275
Cited by
38
References
9
FWCI
1.74
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Midnight salivary cortisol, measured by highly sensitive electrochemiluminescence immunoassay, for the diagnosis of Cushing’s syndrome. https://app.cochat.ai/papers/10.2478/s11536-009-0004-y
The paper
Yaneva, M., Kirilov, G., & Zacharieva, S. (2009). Midnight salivary cortisol, measured by highly sensitive electrochemiluminescence immunoassay, for the diagnosis of Cushing’s syndrome. Open Medicine. https://doi.org/10.2478/s11536-009-0004-y

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.