The DOI matches its Crossref record; 71 of the 71 references it cites were found in a registry or an index.
MIRD Pamphlet No. 23: Quantitative SPECT for Patient-Specific 3-Dimensional Dosimetry in Internal Radionuclide Therapy
Open accessAbstract
In internal radionuclide therapy, a growing interest in voxel-level estimates of tissue-absorbed dose has been driven by the desire to report radiobiologic quantities that account for the biologic consequences of both spatial and temporal nonuniformities in these dose estimates. This report presents an overview of 3-dimensional SPECT methods and requirements for internal dosimetry at both regional and voxel levels. Combined SPECT/CT image-based methods are emphasized, because the CT-derived anatomic information allows one to address multiple technical factors that affect SPECT quantification while facilitating the patient-specific voxel-level dosimetry calculation itself. SPECT imaging and reconstruction techniques for quantification in radionuclide therapy are not necessarily the same as those designed to optimize diagnostic imaging quality. The current overview is intended as an introduction to an upcoming series of MIRD pamphlets with detailed radionuclide-specific recommendations intended to provide best-practice SPECT quantification-based guidance for radionuclide dosimetry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Accelerated image reconstruction using ordered subsets of projection data
Hudson, H. M., & Larkin, R. S. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363108 · Cited by 3,711
Stabin, M. G., Sparks, R. B., & Crowe, E. A. (2005) · PubMed · Cited by 1,350
4D XCAT phantom for multimodality imaging research
Segars, W. P., Sturgeon, G., Mendonca, S., Grimes, J., & Tsui, B. M. W. (2010) · Medical Physics · doi:10.1118/1.3480985 · Cited by 1,287
Bentzen, S. M., Constine, L. S., Deasy, J. O., Eisbruch, A., Jackson, A., Marks, L. B., Ten Haken, R. K., & Yorke, E. D. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.09.040 · Cited by 1,257
Complication Probability as Assessed from Dose-Volume Histograms
Lyman, J. T. (1985) · Radiation Research · doi:10.2307/3576626 · Cited by 1,160
Bolch, W. E., Eckerman, K. F., Sgouros, G., & Thomas, S. R. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.056036 · Cited by 913
Self-citationDale, R. G. (1985) · The British Journal of Radiology · doi:10.1259/0007-1285-58-690-515 · Cited by 835
A practical method for position-dependent Compton-scatter correction in single photon emission CT
Ogawa, K., Harata, Y., Ichihara, T., Kubo, A., & Hashimoto, S. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.97591 · Cited by 616
Siegel, J. A., Thomas, S. R., Stubbs, J. B., Mg, S., Hays, M. T., Koral, K. F., Robertson, J. S., Howell, R. W., Wessels, B. W., Fisher, D. R., et al. (1999) · PubMed · Cited by 572
Self-citationComplication Probability as Assessed from Dose-Volume Histograms
Lyman, J. T. (1985) · Radiation Research Supplement · doi:10.2307/3583506 · Cited by 535
A Monte Carlo program for the simulation of scintillation camera characteristics
Ljungberg, M., & Strand, S.-E. (1989) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(89)90111-9 · Cited by 515
Self-citationX-ray-based attenuation correction for positron emission tomography/computed tomography scanners
Kinahan, P. E., Hasegawa, B. H., & Beyer, T. (2003) · Seminars in Nuclear Medicine · doi:10.1053/snuc.2003.127307 · Cited by 515
2000 IEEE Nuclear Science Symposium Conference Record
(2000) · 2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149) · doi:10.1109/nssmic.2000.949858 · Cited by 496
Segmentation of lung lesion volume by adaptive positron emission tomography image thresholding
Erdi, Y. E., Mawlawi, O., Larson, S. M., Imbriaco, M., Yeung, H., Finn, R., & Humm, J. L. (1997) · Cancer · doi:10.1002/(sici)1097-0142(19971215)80:12+<2505::aid-cncr24>3.0.co;2-f · Cited by 480
(2012) · Elsevier eBooks · doi:10.1016/c2009-0-51635-2 · Cited by 459
Ws, S., Ford, Warner, G. G., & Watson, S. B. (1975) · Cited by 427
Xu, X. G., Chao, T. C., & Bozkurt, A. (2000) · Health Physics · doi:10.1097/00004032-200005000-00003 · Cited by 364
Wyckoff, H. O. (1974) · American Journal of Roentgenology · doi:10.2214/ajr.120.3.708 · Cited by 354
Emission Tomography: The Fundamentals of PET and SPECT
Wernick, M. N., & Aarsvold, J. N. (2004) · Cited by 353
MIRD Pamphlet No. 24: Guidelines for Quantitative 131I SPECT in Dosimetry Applications
Dewaraja, Y. K., Ljungberg, M., Green, A. J., Zanzonico, P. B., Frey, E. C., SNMMI MIRD Committee, Bolch, W. E., Brill, A. B., Dunphy, M., Fisher, D. R., et al. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.113.122390 · Cited by 336
Self-citationOptimal sampling times for pharmacokinetic experiments
D'Argenio, D. Z. (1981) · Journal of Pharmacokinetics and Biopharmaceutics · doi:10.1007/bf01070904 · Cited by 324
Cherry, S. R., Sorenson, J., Phelps, M. E., & Methé, B. M. (2004) · Medical Physics · doi:10.1118/1.1776595 · Cited by 317
Sgouros, G., Kolbert, K. S., Sheikh, A., Pentlow, K. S., Mun, E. F., Barth, A., Robbins, R. J., & Larson, S. M. (2004) · PubMed · Cited by 308
Self-citationBocher, M., Blevis, I. M., Tsukerman, L., Shrem, Y., Kovalski, G., & Volokh, L. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1488-z · Cited by 303
High-resolution SPECT using multipinhole collimation
Schramm, N. U., Ebel, G., Engeland, U., Schurrat, T., Behe, M., & Behr, T. M. (2003) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2003.812437 · Cited by 298
Buck, A. K., Nekolla, S., Ziegler, S., Beer, A., Krause, B. J., Herrmann, K., Scheidhauer, K., Wester, H.-J., Rummeny, E. J., Schwaiger, M., et al. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.050195 · Cited by 282
Quantitative Analysis in Nuclear Medicine Imaging
(2006) · Springer eBooks · doi:10.1007/b107410 · Cited by 266
Bolch, W. E., Bouchet, L. G., Robertson, J. S., Wessels, B. W., Siegel, J. A., Howell, R. W., Erdi, A. K., Aydogan, B., Costes, S. V., Watson, E. E., et al. (1999) · Cited by 253
Self-citationZeintl, J., Vija, A. H., Yahil, A., Hornegger, J., & Kuwert, T. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.071571 · Cited by 252
Bolch, W. E., Bouchet, L. G., Js, R., Wessels, B. W., Ja, S., Howell, R. W., Ak, E., Aydogan, B., Costes, S. V., Ee, W., et al. (1999) · PubMed · Cited by 237
Self-citationA new method for modeling the spatially-variant, object-dependent scatter response function in SPECT
Frey, E. C., & Tsui, B. M. W. (2002) · 1996 IEEE Nuclear Science Symposium. Conference Record · doi:10.1109/nssmic.1996.591559 · Cited by 232
Self-citationNiemierko, A., & Goitein, M. (1991) · Radiotherapy and Oncology · doi:10.1016/0167-8140(91)90093-v · Cited by 230
Garkavij, M., Nickel, M., Sjögreen‐Gleisner, K., Ljungberg, M., Ohlsson, T., Wingårdh, K., Strand, S., & Tennvall, J. (2010) · Cancer · doi:10.1002/cncr.24796 · Cited by 205
Self-citationEANM Dosimetry Committee guidance document: good practice of clinical dosimetry reporting
Lassmann, M., Chiesa, C., Flux, G., & Bardiès, M. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1549-3 · Cited by 198
Efficient fully 3-D iterative SPECT reconstruction with Monte Carlo-based scatter compensation
Beekman, F. J., de Jong, H. W. A. M., & van Geloven, S. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.803130 · Cited by 197
Wessels, B. W., Konijnenberg, M. W., Dale, R. G., Breitz, H. B., Cremonesi, M., Meredith, R. F., Green, A. J., Bouchet, L. G., Brill, A. B., Bolch, W. E., et al. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.053173 · Cited by 194
Self-citationPartial Volume Correction Strategies in PET
Rousset, O., Rahmim, A., Alavi, A., & Zaidi, H. (2007) · PET Clinics · doi:10.1016/j.cpet.2007.10.005 · Cited by 190
Blankespoor, S. C., Xu, X., Kaiki, K., Brown, J. K., Tang, H. R., Cann, C. E., & Hasegawa, B. H. (1996) · IEEE Transactions on Nuclear Science · doi:10.1109/23.531891 · Cited by 170
Scott, J. A. (1993) · Journal of Nuclear Medicine · Cited by 163
The importance and implementation of accurate 3D compensation methods for quantitative SPECT
Tsui, B. M. W., Frey, E. C., Zhao, X., Lalush, D. S., Johnston, R. E., & McCartney, W. H. (1994) · Physics in Medicine and Biology · doi:10.1088/0031-9155/39/3/015 · Cited by 161
Self-citationDewaraja, Y. K., Wilderman, S. J., Ljungberg, M. H., et al. (2005) · PubMed · Cited by 143
Self-citationThe Impact of PET and SPECT on Dosimetry for Targeted Radionuclide Therapy
Flux, G., Bardiès, M., Monsieurs, M. A., Savolainen, S. E., Strand, S., & Laßmann, M. (2006) · Zeitschrift für Medizinische Physik · doi:10.1078/0939-3889-00291 · Cited by 132
Bäck, T. A., & Jacobsson, L. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.077578 · Cited by 131
Sgouros, G., Squeri, S., Ballangrud, Å., Kolbert, K. S., Teitcher, J. B., Panageas, K. S., Finn, R. D., Divgi, C. R., Larson, S. M., & Zelenetz, A. D. (2003) · PubMed · Cited by 119
Self-citationEvaluation of quantitative90Y SPECT based on experimental phantom studies
Minarik, D., Gleisner, K. S., & Ljungberg, M. H. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/20/008 · Cited by 118
Self-citationA Monte Carlo and physical phantom evaluation of quantitative In-111 SPECT
He, B., Du, Y., Song, X., Segars, W. P., & Frey, E. C. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/17/018 · Cited by 116
Self-citationQuantitative accuracy of dopaminergic neurotransmission imaging with (123)I SPECT.
Soret, M., Koulibaly, P. M., Darcourt, J., Hapdey, S., & Buvat, I. (2003) · PubMed · Cited by 110
Implications of nonuniform tumor doses for radioimmunotherapy.
O'Donoghue, J. A. (1999) · PubMed · Cited by 109
Narita, Y., Eberl, S., Iida, H., Hutton, B. F., Braun, M., Nakamura, T., & Bautovich, G. J. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/017 · Cited by 107
Dewaraja, Y. K., Schipper, M. J., Roberson, P. L., Wilderman, S. J., Amro, H., Regan, D., Koral, K. F., Kaminski, M. S., & Avram, A. M. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.075176 · Cited by 98
Self-citationHobbs, R. F., Wahl, R. L., Lodge, M. A., Javadi, M. S., Cho, S. Y., Chien, D. T., Ewertz, M., Esaias, C. E., Ladenson, P. W., & Sgouros, G. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.066738 · Cited by 90
Self-citationSilva, A. J. D., Tang, H. R., Wong, K. H., Wu, M. C., Dae, M. W., & Hasegawa, B. H. (2001) · PubMed · Cited by 87
Bowsher, J. E., & Floyd, C. E. (1991) · PubMed · Cited by 86
Lung dosimetry for radioiodine treatment planning in the case of diffuse lung metastases.
Hong, S., He, B., Prideaux, A. R., Du, Y., Frey, E. C., Kasecamp, W., Ladenson, P. W., Wahl, R. L., & Sgouros, G. (2006) · PubMed · Cited by 82
Self-citationKoral, K. F., Dewaraja, Y. K., Li, J., Lin, Q., Regan, D., Zasadny, K. R., Rommelfanger, S. G., Francis, I. R., Kaminski, M. S., & Wahl, R. L. (2003) · PubMed · Cited by 75
Self-citationLjungberg, M. H., Frey, E. C., Gleisner, K. S., Liu, X., Dewaraja, Y. K., & Strand, S. (2003) · Cancer Biotherapy and Radiopharmaceuticals · doi:10.1089/108497803321269377 · Cited by 74
Self-citationCollimator-Detector Response Compensation in SPECT
Frey, E. C., & Tsui, B. M. W. (2006) · Springer eBooks · doi:10.1007/0-387-25444-7_5 · Cited by 70
Self-citation90Y Bremsstrahlung Imaging for Absorbed-Dose Assessment in High-Dose Radioimmunotherapy
Minarik, D., Gleisner, K. S., Lindén, O., Wingårdh, K., Tennvall, J., Strand, S., & Ljungberg, M. H. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.079897 · Cited by 62
Self-citationAttenuation, Scatter, and Spatial Resolution Compensation in SPECT
King, M. A., Glick, S. J., Pretorius, P. H., Wells, R. G., Gifford, H. C., Narayanan, M. V., & Farncombe, T. H. (2004) · Elsevier eBooks · doi:10.1016/b978-012744482-6.50025-9 · Cited by 61
Hybrid scatter correction applied to quantitative holmium-166 SPECT
de Wit, T. C., Xiao, J., Nijsen, J. F. W., Schip, F. V. H., Staelens, S. G., van Rijk, P. P., & Beekman, F. J. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/19/004 · Cited by 56
He, B., Du, Y., Segars, W. P., Wahl, R. L., Sgouros, G., Jacene, H. A., & Frey, E. C. (2009) · Medical Physics · doi:10.1118/1.3063156 · Cited by 54
Self-citationJentzen, W. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/8/016 · Cited by 54
Iterative Reconstruction Methods
Hutton, B. F., Nuyts, J. L., & Zaidi, H. (2006) · Springer eBooks · doi:10.1007/0-387-25444-7_4 · Cited by 47
Image Segmentation Techniques in Nuclear Medicine Imaging
Boudraa, A., & Zaidi, H. (2006) · Kluwer Academic Publishers eBooks · doi:10.1007/0-387-25444-7_10 · Cited by 47
He, B., & Frey, E. C. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/12/017 · Cited by 42
Self-citationIterative Image Reconstruction
Lalush, D. S., & Wernick, M. N. (2004) · Elsevier eBooks · doi:10.1016/b978-012744482-6.50024-7 · Cited by 41
Dewaraja, Y. K., Wilderman, S. J., Koral, K. F., et al. (2009) · Cancer Biotherapy and Radiopharmaceuticals · doi:10.1089/cbr.2008.0568 · Cited by 39
Self-citationHe, B., & Frey, E. C. (2010) · Medical Physics · doi:10.1118/1.3358119 · Cited by 28
Self-citationAttenuation Correction Strategies in Emission Tomography
Zaidi, H., & Hasegawa, B. H. (2006) · Kluwer Academic Publishers eBooks · doi:10.1007/0-387-25444-7_6 · Cited by 13
Arterial Wall Dosimetry for Non-Hodgkin Lymphoma Patients Treated with Radioimmunotherapy
Hobbs, R. F., Baechler, S., Wahl, R. L., He, B., Hong, S., Esaias, C. E., Frey, E. C., Jacene, H. A., & Sgouros, G. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.069575 · Cited by 12
Self-citation
Cited by
Radiopharmaceutical therapy in cancer: clinical advances and challenges
Sgouros, G., Bodei, L., McDevitt, M. R., & Nedrow, J. R. (2020) · Nature Reviews Drug Discovery · doi:10.1038/s41573-020-0073-9 · Cited by 963
Self-citationAuger electrons for cancer therapy – a review
Ku, A., Facca, V. J., Cai, Z., & Reilly, R. M. (2019) · EJNMMI Radiopharmacy and Chemistry · doi:10.1186/s41181-019-0075-2 · Cited by 643
Ljungberg, M., Celler, A., Konijnenberg, M. W., Eckerman, K. F., Dewaraja, Y. K., & Sjögreen-Gleisner, K. (2016) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.159012 · Cited by 369
Self-citationMIRD Pamphlet No. 24: Guidelines for Quantitative 131I SPECT in Dosimetry Applications
Dewaraja, Y. K., Ljungberg, M., Green, A. J., Zanzonico, P. B., Frey, E. C., SNMMI MIRD Committee, Bolch, W. E., Brill, A. B., Dunphy, M., Fisher, D. R., et al. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.113.122390 · Cited by 336
Self-citationDelker, A., Fendler, W. P., Kratochwil, C., Brunegraf, A., Gosewisch, A., Gildehaus, F. J., Tritschler, S., Stief, C. G., Kopka, K., Haberkorn, U., et al. (2016) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3174-7 · Cited by 322
Metadata
- Authors
- Dewaraja, Y. K., Frey, E. C., Sgouros, G., Brill, A. B., Roberson, P., Zanzonico, P. B., & Ljungberg, M.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2012-06-28
- Volume
- 53
- Issue
- 8
- Pages
- 1310-1325
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2148878903
- Cited by
- 419
- References
- 71
- FWCI
- 10.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.