CoChat

Multielectrode spiral cuff for selective stimulation of nerve fibres

Rozman, J., Trlep, M. · 1992 · Journal of Medical Engineering & Technology
Cited by 21

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

In this paper we present the modelling, design, and initial experimental testing of a nerve cuff multielectrode system for selective stimulation of fibres in superficial peripheral nerve trunk regions which is capable of making a selective activation of multiple muscles. The developed multielectrode nerve cuff consists of 14 platinum stimulating electrodes embedded within a self-curling sheet of biocompatible insulation, exhibiting a spiral transverse cross-section. The spiral shape of the system is such that the number of stimulating electrodes which can be utilized depends on the diameter of the stimulated nerve. Nerves with a greater diameter automatically make use of more electrodes than thin ones. The development was based on results obtained by a histological examination of the peripheral nerves which were planned to be stimulated, and on models of excitation of myelinated nerve fibres. The modelling objectives were to determine the electric field that would be generated within a nerve trunk by a specific electrode. Moreover, the extent of initial excitation of the nerve fibres within the superficial region of the dog sciatic nerve elicited by a certain discrete stimulating electrode was predicted. For this purpose a calculation of activating function for six positions where the nerve fibres were supposed to lie within the longitudinally dissected sciatic nerve was performed. In two acute experiments on the sciatic nerve of the dog the objective was to characterize the effectiveness of the multielectrode system in monopolar selective stimulation of the superficial regions, innervating the gastrocnemius and tibialis anterior muscle. A selectivity preliminary tested by measuring the myoelectric activity of the gastrocnemius and tibialis anterior muscle after 2 months showed good results in both animals.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3109/03091909209021983

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 21

Metadata

Authors
Rozman, J., & Trlep, M.
Venue
Journal of Medical Engineering & Technology
Published
1992-01
Volume
16
Issue
5
Pages
194-203
ISSN
  • 0309-1902 (ISSN-L)
  • 1464-522X
OpenAlex
W2045676377
Cited by
21
References
12
FWCI
0.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multielectrode spiral cuff for selective stimulation of nerve fibres. https://app.cochat.ai/papers/10.3109/03091909209021983
The paper
Rozman, J., & Trlep, M. (1992). Multielectrode spiral cuff for selective stimulation of nerve fibres. Journal of Medical Engineering & Technology. https://doi.org/10.3109/03091909209021983

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.