A modeling study of nerve fascicle stimulation
Open accessAbstract
A nerve stimulation model has been developed, incorporating realistic cross-sectional nerve geometries and conductivities. The potential field in the volume conductor was calculated numerically using the variational method. Nerve fiber excitation was described by the model of McNeal. Cross-sectional geometries of small monofascicular rat common peroneal nerve and multifascicular human deep peroneal nerve were taken as sample geometries. Selective stimulation of a fascicle was theoretically analyzed for several electrode positions: outside the nerve, in the connective tissue of the nerve, and inside a fascicle. The model results predict that the use of intraneural or even intrafascicular electrodes is necessary for selective stimulation of fascicles not lying at the surface of the nerve. Model predictions corresponded with experimental results of Veltink et al. on intrafascicular and extraneural stimulation of rat common peroneal nerve and to results of McNeal and Bowman on muscle selective stimulation in multifascicular dog sciatic nerve using an extraneural multielectrode configuration.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In a nerve with multiple fascicles, groups of motor neurons are scattered among fascicles, and because fascicles have different locations, selective stimulation may be achieved by electrodes in their neighborhood.
“In a nerve with multiple fascicles, groups of motor neurons are scattered among fascicles. These fascicles have different locations in the nerve, therefore their selective stimulation may be achieved by electrodes in their neighborhood [78].”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [78]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Which elements are excited in electrical stimulation of mammalian central nervous system: A review
Ranck, J. B. (1975) · Brain Research · doi:10.1016/0006-8993(75)90364-9 · Cited by 2,024 · see citing works
Current Problems of Lower Vertebrate Phylogeny
Romanes, G. J. (1969) · Journal of Anatomy · Cited by 1,830 · see citing works
Björck, Å., Dahlquist, G. G., & Anderson, N. (1974) · Cited by 1,719 · see citing works
Geddes, L. A., & Baker, L. E. (1967) · Medical & Biological Engineering & Computing · doi:10.1007/bf02474537 · Cited by 1,612 · see citing works
Analysis of a Model for Excitation of Myelinated Nerve
McNeal, D. R. (1976) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1976.324593 · Cited by 833 · see citing works
Sunderland, S., & SMITH, J. W. (1969) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-196912000-00013 · Cited by 753 · see citing works
FRANKENHAEUSER, B., & Huxley, A. F. (1964) · The Journal of Physiology · doi:10.1113/jphysiol.1964.sp007378 · Cited by 702 · see citing works
Analysis of Models for External Stimulation of Axons
Rattay, F. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325670 · Cited by 681 · see citing works
(1984) · Annals of Internal Medicine · doi:10.7326/0003-4819-101-4-579_1 · Cited by 518 · see citing works
The Effect of Stimulus Parameters on the Recruitment Characteristics of Direct Nerve Stimulation
Gorman, P. H., & Mortimer, J. T. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325041 · Cited by 313 · see citing works
External Control of the Neuromuscular System
Solomonow, M. (1984) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1984.325235 · Cited by 171 · see citing works
Selective activation of muscles using peripheral nerve electrodes
McNeal, D. R., & Bowman, B. R. (1985) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446866 · Cited by 98 · see citing works
Yamashita, Y., & Takahashi, T. (1984) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1984.325305 · Cited by 77 · see citing works
Simulation of intrafascicular and extraneural nerve stimulation
Veltink, P. H., van Alste, J. A., & Boom, H. B. K. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.1338 · Cited by 71 · see citing works
Self-citationSequential motor unit stimulation through peripheral motor nerves in the cat
Petrofsky, J. S. (1979) · Medical & Biological Engineering & Computing · doi:10.1007/bf02440958 · Cited by 67 · see citing works
Bowman, B. R., & Erickson, R. C. (1985) · Annals of Biomedical Engineering · doi:10.1007/bf02371251 · Cited by 66 · see citing works
Pilkington, T. C., Morrow, M. N., & Stanley, P. C. (1985) · PubMed · Cited by 63 · see citing works
Multielectrode intrafascicular and extraneural stimulation
Veltink, P. H., van Alsté, J. A., & Boom, H. B. K. (1989) · Medical and Biological Engineering and Computing · doi:10.1007/bf02442165 · Cited by 62 · see citing works
Self-citationFunctional Electrical Stimulation
Sivaram, C. (2009) · Jaypee Brothers Medical Publishers (P) Ltd. eBooks · doi:10.5005/jp/books/10675_43 · Cited by 55 · see citing works
Stegeman, D. F., & de Weerd, J. P. C. (1982) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(82)90207-3 · Cited by 51 · see citing works
Control of muscle contractile force through indirect high-frequency stimulation.
Solomonow, M., Eldred, E., Lyman, J., & Foster, J. (1983) · PubMed · Cited by 48 · see citing works
Pilkington, T. C., Morrow, M. N., & Stanley, P. C. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325438 · Cited by 42 · see citing works
Influences of stimulation conditions on recruitment of myelinated nerve fibres: a model study
Veltink, P. H., van Alste, J. A., & Boom, H. B. K. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8671 · Cited by 37 · see citing works
Self-citationPathologie der peripheren Nerven
Krücke, W. (1974) · Handbuch der Neurochirurgie · doi:10.1007/978-3-642-65361-2_1 · Cited by 32 · see citing works
HOLLE, J., Mortiz, E., THOMA, H., & Lischka, A. R. (1974) · PubMed · Cited by 18 · see citing works
Handbuch der Neurochirurgie: Peripheres und Sympathisches Nervensystem
Kempe, L. G. (1975) · Archives of Surgery · doi:10.1001/archsurg.1975.01360130083032 · Cited by 1 · see citing works
Flagged first, then by citations
3 of the 29 references couldn’t be matched to a known paper.
Research works printed but not linked: 7
- J. Holle, E. Moritz, and H. Thoma, "Die Karusselstimulation, eine n e w Methode zur elektrophrenische Langzeitbeatmung," Wiener klinische Wochenschriji, vol. 86, pp. 23-27, 1974.
- J. S. Petrofsky and C. A. Phillips, "Impact of recruitment order on electrode design for neural prosthetics of skeletal muscle," Amer. J. Phys. Med., vol. 60, pp. 243-253, 1981.
- Z.-P. Fang and J. T. Mortimer, "A method for attaining natural re- cruitment order in artificially activated muscles," in Proc. 9th Annu. Conf. IEEE Eng. Med. Biol. Soc., Boston, MA, 1987, pp. 657-658.
- E. Moritz, J. Holle, H. Thoma, and H. Stohr, "Further experiences with elektrophrenic respiration," in Proc. 1st Vienna Internat. Work- shop Functional Electrostimulation, 1983.
- P. K . Thomas and J. Ochoa, "Microscopic anatomy of peripheral 87-93, 1979. 23, pp. 249-253, 1985. put., vol. 27, pp. 19-24, 1989. BME-32, 166-173, 1985. 1974, pp. 1-142.
- D. R. McNeal and D. A. Teicher, "Effect of electrode placement on threshold and initial site of excitation of a myelinated nerve fiber," in Funcrional Electrical Stimularion, F. T. Hambrecht and J . B. Reswick, Eds. 1211 D. R. McNeal and A. V. Apkarian, "Analytical design of a cuff elec- trode," in Proc. 6th Inr. Symp. Exrernal Contr. Humm Extremities, Dubrovnik, pp. 45-54, 1978.
- J. D. Sweeney, J. T. Mortimer, and D. Durand, "Modeling of mam- malian myelinated nerve for functional neuromuscular stimulation." in Proc. 9th Annu. Conj IEEE Eng. Med. Biol. Soc., Boston. MA. 1281
Cited by
Sorted by citations
Electrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827 · see citing works
Implanted Neural Interfaces: Biochallenges and Engineered Solutions
Grill, W. M., Norman, S. E., & Bellamkonda, R. V. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124927 · Cited by 488 · see citing works
Functionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398 · see citing works
Selective Electrical Interfaces with the Nervous System
Rutten, W. L. C. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153427 · Cited by 276 · see citing works
Badia, J., Boretius, T., Andreu, D., Azevedo-Coste, C., Stieglitz, T., & Navarro, X. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036023 · Cited by 227 · see citing works
Fascicular perineurium thickness, size, and position affect model predictions of neural excitation
Grinberg, Y., Schiefer, M. A., Tyler, D. J., & Gustafson, K. J. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2010348 · Cited by 145 · see citing works
“They have been used to predict fascicular selectivity for stimulation [9-17] and recording [1822] using various electrode configurations.”
Quantification of recruitment properties of multiple contact cuff electrodes
Grill, W. M., & Mortimer, J. T. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.506402 · Cited by 136 · see citing works
Selectivity of multiple-contact nerve cuff electrodes: a simulation analysis
Choi, A. Q., Cavanaugh, J. K., & Durand, D. M. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.909637 · Cited by 121 · see citing works
Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review
Yildiz, K. A., Shin, A. Y., & Kaufman, K. R. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00667-5 · Cited by 113 · see citing works
A model of the electrical behaviour of myelinated sensory nerve fibres based on human data
Wesselink, W. A., Holsheimer, J., & Boom, H. B. K. (1999) · Medical & Biological Engineering & Computing · doi:10.1007/bf02513291 · Cited by 116 · see citing works
Self-citationApplication of a computational model of vagus nerve stimulation
Helmers, S. L., Begnaud, J., Cowley, A. C., Corwin, H. M., Edwards, J. C., Holder, D. L., Kostov, H., Larsson, P. G., Levisohn, P. M., de Menezes, M. S., et al. (2012) · Acta Neurologica Scandinavica · doi:10.1111/j.1600-0404.2012.01656.x · Cited by 111 · see citing works
Modeling the effects of electric fields on nerve fibers: influence of tissue electrical properties
Grill, W. M. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.775401 · Cited by 110 · see citing works
Inversion of the current-distance relationship by transient depolarization
Grill, W. M., & Mortimer, J. T. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.553708 · Cited by 109 · see citing works
A slowly penetrating interfascicular nerve electrode for selective activation of peripheral nerves
Tyler, D. J., & Durand, D. M. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.559349 · Cited by 108 · see citing works
Grill, W. M., & Mortimer, J. T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.736150 · Cited by 103 · see citing works
Struijk, J. J., Holsheimer, J., van Veen, B. K., & Boom, H. B. K. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68217 · Cited by 85 · see citing works
Self-citationHowell, B. L., & McIntyre, C. C. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036023 · Cited by 78 · see citing works
Microchannels as Axonal Amplifiers
FitzGerald, J. J., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.909533 · Cited by 76 · see citing works
Analysis of current density and related parameters in spinal cord stimulation
Wesselink, W. A., Holsheimer, J., & Boom, H. B. K. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.681186 · Cited by 64 · see citing works
Self-citationPERIPHERAL NERVE AND MUSCLE STIMULATION
Mortimer, J. T., & Bhadra, N. (2004) · Series on bioengineering and biomedical engineering · doi:10.1142/9789812561763_0020 · Cited by 58 · see citing works
Model-based analysis and design of waveforms for efficient neural stimulation
Grill, W. M. (2015) · Progress in brain research · doi:10.1016/bs.pbr.2015.07.031 · Cited by 57 · see citing works
Recruitment characteristics of nerve fascicles stimulated by a multigroove electrode
Koole, P., Holsheimer, J., Struijk, J. J., & Verloop, A. J. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.559348 · Cited by 56 · see citing works
Self-citationSchiefer, M. A., Tyler, D. J., & Triolo, R. J. (2012) · Journal of Computational Neuroscience · doi:10.1007/s10827-011-0381-5 · Cited by 53 · see citing works
Gaunt, R. A., Hokanson, J. A., & Weber, D. J. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/055009 · Cited by 53 · see citing works
Neuromuscular stimulation selectivity of multiple-contact nerve cuff electrode arrays
Sweeney, J. D., Crawford, N. R., & Brandon, T. A. (1995) · Medical & Biological Engineering & Computing · doi:10.1007/bf02510525 · Cited by 51 · see citing works
Kreisberg, E., Esmaeilpour, Z., Adair, D., Khadka, N., Datta, A., Badran, B. W., Bremner, J. D., & Bikson, M. (2021) · Brain stimulation · doi:10.1016/j.brs.2021.09.001 · Cited by 43 · see citing works
Selective neural activation in a histologically derived model of peripheral nerve
Butson, C. R., Miller, I., Normann, R. A., & Clark, G. A. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036009 · Cited by 42 · see citing works
Multielectrode spiral cuff for ordered and reversed activation of nerve fibres
Rozman, J., Sovinec, B., Trlep, M., & Zorko, B. (1993) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(93)90039-2 · Cited by 41 · see citing works
Investigation of mechanisms of vagus nerve stimulation for seizure using finite element modeling
Arle, J. E., Carlson, K. W., & Mei, L. (2016) · Epilepsy Research · doi:10.1016/j.eplepsyres.2016.07.009 · Cited by 40 · see citing works
Transverse tripolar stimulation of peripheral nerve: a modelling study of spatial selectivity
Deurloo, K. E. I., Holsheimer, J., & Boom, H. B. K. (1998) · Medical & Biological Engineering & Computing · doi:10.1007/bf02522860 · Cited by 40 · see citing works
Self-citationPyPNS: Multiscale Simulation of a Peripheral Nerve in Python
Lubba, C. H., Guen, Y. L., Jarvis, S., Jones, N. S., Cork, S. C., Eftekhar, A., & Schultz, S. R. (2018) · Neuroinformatics · doi:10.1007/s12021-018-9383-z · Cited by 38 · see citing works
Flat electrode contacts for vagus nerve stimulation
Bucksot, J. E., Wells, A. J., Rahebi, K. C., Sivaji, V., Romero‐Ortega, M. I., Kilgard, M. P., Rennaker, R. L., & Hays, S. A. (2019) · PLoS ONE · doi:10.1371/journal.pone.0215191 · Cited by 36 · see citing works
Mortimer, T., Agnew, W. F., Horch, K. W., Citron, P., Creasey, G. H., & Kantor, C. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.392373 · Cited by 34 · see citing works
Implantable stimulator for selective stimulation of the common peroneal nerve: a preliminary report
Rozman, J., Aćimović-Janežič, R., Tekavčič, I., Kljajić, M. V., & Trlep, M. (1994) · Journal of Medical Engineering & Technology · doi:10.3109/03091909409030228 · Cited by 25 · see citing works
Peripheral Nervous System Topics
Marani, E., & Lakke, E. A. J. F. (2012) · Elsevier eBooks · doi:10.1016/b978-0-12-374236-0.10004-5 · Cited by 24 · see citing works
Bourbeau, D. J., Hokanson, J., Rubin, J. E., & Weber, D. J. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/5/056009 · Cited by 23 · see citing works
Multielectrode spiral cuff for selective stimulation of nerve fibres
Rozman, J., & Trlep, M. (1992) · Journal of Medical Engineering & Technology · doi:10.3109/03091909209021983 · Cited by 21 · see citing works
Lontis, R., Nielsen, K. T., & Struijk, J. J. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2009929 · Cited by 20 · see citing works
Self-citationJohnson, M. D., Dweiri, Y. M., Cornelius, J. R., Strohl, K. P., Steffen, A., Suurna, M. V., Soose, R. J., Coleman, M., Rondoni, J., Durand, D. M., et al. (2021) · SLEEP · doi:10.1093/sleep/zsaa269 · Cited by 20 · see citing works
Deurloo, K. E. I., Holsheimer, J., & Bergveld, P. (2003) · Neuromodulation: Technology at the Neural Interface · doi:10.1046/j.1525-1403.2003.03034.x · Cited by 20 · see citing works
Self-citationSimulation of intra-orbital optic nerve electrical stimulation
Oozeer, M., Veraart, C., Legat, V., & Delbeke, J. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02351034 · Cited by 20 · see citing works
Biomechatronics – Assisting the Impaired Motor System
Veltink, P. H., Koopman, H. F. J. M., van der Helm, F. C. T., & Nene, A. V. (2001) · Archives of Physiology and Biochemistry · doi:10.1076/apab.109.1.1.4282 · Cited by 20 · see citing works
Self-citationLivshitz, L. M., Einziger, P. D., & Mizrahi, J. (2000) · Annals of Biomedical Engineering · doi:10.1114/1.1320842 · Cited by 20 · see citing works
A Flat Interface Nerve Electrode With Integrated Multiplexer
Lertmanorat, Z., Montague, F. W., & Durand, D. M. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2009307 · Cited by 18 · see citing works
Modeling transcutaneous electrical stimulation
Kühn, A. (2008) · Repository for Publications and Research Data (ETH Zurich) · doi:10.3929/ethz-a-005677404 · Cited by 18 · see citing works
Modelling selective activation of small myelinated nerve fibres using a monopolar point electrode
Rijkhoff, N., Holsheimer, J., Debruyne, F. M. J., & Wijkstra, H. (1995) · Medical & Biological Engineering & Computing · doi:10.1007/bf02523007 · Cited by 17 · see citing works
Self-citationRoth, B. J., & Altman, K. W. (1992) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446201 · Cited by 16 · see citing works
Nielsen, T. N., Sevcencu, C., & Struijk, J. J. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2278479 · Cited by 15 · see citing works
Self-citationHarreby, K. R., Kundu, A., Yoshida, K., Boretius, T., Stieglitz, T., & Jensen, W. (2014) · Artificial Organs · doi:10.1111/aor.12347 · Cited by 14 · see citing works
Effects of Synchronous Electrode Pulses on Neural Recruitment During Multichannel Microstimulation
Hokanson, J., Gaunt, R. A., & Weber, D. J. (2018) · Scientific Reports · doi:10.1038/s41598-018-31247-2 · Cited by 13 · see citing works
A Nerve Cuff Electrode for Controlled Reshaping of Nerve Geometry
Caparso, A., Durand, D. M., & Mansour, J. M. (2008) · Journal of Biomaterials Applications · doi:10.1177/0885328208097426 · Cited by 12 · see citing works
Szlavik, R. B., & de Bruin, H. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.867947 · Cited by 12 · see citing works
Zellmer, E. R., MacEwan, M. R., & Moran, D. W. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa9e96 · Cited by 12 · see citing works
Fascicle-Selectivity of an Intraneural Stimulation Electrode in the Rabbit Sciatic Nerve
Nielsen, T. N., Sevcencu, C., & Struijk, J. J. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2169671 · Cited by 11 · see citing works
Self-citationRozman, J., Pečlin, P., Ribarič, S., Godec, M., & Burja, J. (2018) · Scientific Reports · doi:10.1038/s41598-018-19318-w · Cited by 11 · see citing works
Du, J., Morales, A., Paknahad, J., Kosta, P., Bouteiller, J. C., Fernández, E., & Lazzi, G. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9631068 · Cited by 11 · see citing works
Computation of the electrical potential inside the nerve induced by an electrical stimulus
Jacquir, S., Fruitet, J., Guiraud, D., & Clerc, M. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352639 · Cited by 11 · see citing works
Liu, J., Grayden, D. B., Keast, J. R., & John, S. E. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/aca69e · Cited by 10 · see citing works
Modeling the Impact of the Variation in Peripheral Nerve Anatomy on Stimulation
Mishra, L. N., Kulkarni, G., & Gadgil, M. (2022) · Journal of Pain Research · doi:10.2147/jpr.s380546 · Cited by 8 · see citing works
Design and acute test of a radially penetrating interfascicular nerve electrode
Tyler, D. J., & Durand, D. M. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1993.979118 · Cited by 8 · see citing works
Principles of Electric Field Generation for Stimulation of the Central Nervous System
Grill, W. M. (2009) · Elsevier eBooks · doi:10.1016/b978-0-12-374248-3.00015-x · Cited by 7 · see citing works
Modeling of electric field effects on the excitability of myelinated motor nerve
Sweeney, J., Deng, K., Warman, E., & Mortimer, J. T. (2003) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1989.96194 · Cited by 6 · see citing works
Modeling the response of small myelinated and unmyelinated axons to kilohertz frequency signals
Pelot, N. A., Behrend, C. E., & Grill, W. M. (2015) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2015.7146645 · Cited by 5 · see citing works
Influence of inhomogeneities in muscle tissue on single-fibre action potentials: a model study
Rutten, W. L. C., van Veen, B. K., Stroeve, S., Boom, H. B. K., & Wallinga, W. (1997) · Medical & Biological Engineering & Computing · doi:10.1007/bf02534136 · Cited by 5 · see citing works
Self-citationReliability of Closed Double Helix Electrode for Functional Electrical Stimulation
Kagaya, H., Sharma, M., Polando, G., & Marsolais, E. B. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199801000-00029 · Cited by 4 · see citing works
Pečlin, P., Rozman, J., Krajnik, J., & Ribarič, S. (2016) · Artificial Organs · doi:10.1111/aor.12693 · Cited by 4 · see citing works
Schiefer, M. A., Tyler, D. J., & Triolo, R. J. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091011 · Cited by 5 · see citing works
Effect of external tissue resistivity on threshold level of myelinated nerve fiber
Hayami, T., Iramina, K., & Chen, X. (2010) · Electronics and Communications in Japan · doi:10.1002/ecj.10065 · Cited by 4 · see citing works
Finite element analysis of electrical nerve stimulation
Cavanaugh, J. K., Lin, J.-C., & Durand, D. M. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1996.656990 · Cited by 4 · see citing works
Effects of tissue electrical properties on neural excitation
Grill, W. M. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1996.656987 · Cited by 4 · see citing works
Clerc, M., Veltz, R., Guiraud, D., & Divoux, J. (2008) · HAL · Cited by 4 · see citing works
Multielectrode Cuff For Extraneural Selective Stimulation Of Nerve Fibers
Rozman, J. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1991.684259 · Cited by 4 · see citing works
Wu, Y., & Guo, L. (2020) · Neural Interface Engineering · doi:10.1007/978-3-030-41854-0_5 · Cited by 3 · see citing works
Optimization of inactivating current waveform for selective peripheral nerve stimulation
Deurloo, K. E. I., Boere, C. J. P., de Jong, E. J., & Holsheimer, J. (1997) · University of Twente Research Information · Cited by 3 · see citing works
Self-citationComputational Modeling of an Endovascular Peripheral Nerve Interface
Liu, J., Grayden, D. B., Keast, J. R., & John, S. E. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630085 · Cited by 3 · see citing works
Schiefer, M. A. (2009) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 3 · see citing works
Boŝnjak, R., Dolenc, V. V., & Kralj, A. R. (1999) · Neurologia medico-chirurgica · doi:10.2176/nmc.39.659 · Cited by 3 · see citing works
Grill, W. M. (2006) · Wiley Encyclopedia of Biomedical Engineering · doi:10.1002/9780471740360.ebs0825 · Cited by 3 · see citing works
Modeling Peripheral Nerve Stimulation
Dali, M., & Guiraud, D. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_61 · Cited by 2 · see citing works
Modeling Peripheral Nerve Stimulation
Dali, M., & Guiraud, D. (2021) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_61-1 · Cited by 2 · see citing works
VENTRAL ROOT OR DORSAL ROOT GANGLION MICROSTIMULATION TO EVOKE HINDLIMB MOTOR RESPONSES
Bourbeau, D. J. (2011) · D-Scholarship@Pitt (University of Pittsburgh) · Cited by 2 · see citing works
NOVEL PROCESSING ROUTES FOR NEURAL INTERFACES
Barrett, R. C. (2014) · University of Birmingham Institutional Research Archive (University of Birmingham) · doi:10.13140/2.1.1683.2647 · Cited by 2 · see citing works
Rutten, W. L. C. (1999) · Wiley eBooks · doi:10.1002/047134608x.w1429 · Cited by 2 · see citing works
The Effect of the External Tissue Resistivity to the Threshold Level of a Myelinated Nerve Fiber
Hayami, T., Iramina, K., & Chen, X. (2007) · IEEJ Transactions on Electronics Information and Systems · doi:10.1541/ieejeiss.127.1667 · Cited by 1 · see citing works
Motor Response of the Leg Muscles Produced by Position-selective Stimulation of Spinal Nerve Roots
Boŝnjak, R., Dolenc, V. V., Pregelj, R., & Kralj, A. R. (2000) · Neurosurgery · doi:10.1097/00006123-200007000-00021 · Cited by 1 · see citing works
Multi-Electrode Stimulation Of Myelinated Nerve Fibers
Veltink, P. H., van Alste, J. A., & Holsheimer, J. (1993) · Springer eBooks · doi:10.1007/978-3-642-58069-7_33 · Cited by 1 · see citing works
Self-citationGoffredo, M., Conforto, S., Schmid, M., & D’Alessio, T. (2010) · Control and Intelligent Systems · doi:10.2316/j.2010.216.680-0192 · Cited by 1 · see citing works
Stimulation selectivity of an interfascicular electrode in the sciatic nerve of rabbits
Nielsen, T. N., Sevcencu, C., & Struijk, J. J. (2010) · VBN Forskningsportal (Aalborg Universitet) · doi:10.1111/j.1525-1594.2010.01075.x · Cited by 1 · see citing works
Self-citationPeripheral Nerve Interface, Epineural Electrode
Fisher, L. E. (2014) · Springer eBooks · doi:10.1007/978-1-4614-7320-6_210-1 · Cited by 1 · see citing works
Nonlinear model of nerve fiber's electrical stimulation
Shen, Q., & Jiang, D. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2000.897923
Hokanson, J. (2014) · D-Scholarship@Pitt (University of Pittsburgh)
Model development for electrical stimulation of a large number of interacting axons
Lin, J.-C., & Durand, D. M. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1996.656989
Tessier-Lariviere, O., Prince, L. Y., Fortier-Poisson, P., Wernisch, L., Armitage, O. E., Hewage, E., Lajoie, G., & Richards, B. A. (2021) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner49283.2021.9441284
Peripheral Nerve Interface, Epineural Electrode
Fisher, L. E. (2022) · Springer eBooks · doi:10.1007/978-1-0716-1006-0_210
Peripheral Nerve Interface, Epineural Electrode
Fisher, L. E. (2015) · Springer eBooks · doi:10.1007/978-1-4614-6675-8_210
- Authors
- Veltink, P. H., van Veen, B. K., Struijk, J. J., Holsheimer, J., & Boom, H. B. K.
- Affiliations
- University of Twente (NL)
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1989-07
- Volume
- 36
- Issue
- 7
- Pages
- 683-692
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2113988734
- Cited by
- 95
- References
- 29
- Citations by year
- 2023: 1 · 2022: 3 · 2021: 6 · 2020: 2 · 2019: 1 · 2018: 3 · 2017: 1 · 2016: 3 · 2015: 3 · 2014: 4 · 2013: 1 · 2012: 3
- FWCI
- 0.55
- Type
- journal article
- Language
- en
- Open access
- green
- research.utwente.nl
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- University of Twente Research Information (submittedVersion, other-oa)
- Funders
- University of Twente
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Keywords
- intrafascicular electrodes, peroneal nerve, deep peroneal nerve
- MeSH terms
- Animals, Electric Conductivity, Electric Stimulation, Humans, Mathematics, Models, Neurological, Peripheral Nerves, Peroneal Nerve, Recruitment, Neurophysiological, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review