Multielectrode spiral cuff for selective stimulation of nerve fibres
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
In this paper we present the modelling, design, and initial experimental testing of a nerve cuff multielectrode system for selective stimulation of fibres in superficial peripheral nerve trunk regions which is capable of making a selective activation of multiple muscles. The developed multielectrode nerve cuff consists of 14 platinum stimulating electrodes embedded within a self-curling sheet of biocompatible insulation, exhibiting a spiral transverse cross-section. The spiral shape of the system is such that the number of stimulating electrodes which can be utilized depends on the diameter of the stimulated nerve. Nerves with a greater diameter automatically make use of more electrodes than thin ones. The development was based on results obtained by a histological examination of the peripheral nerves which were planned to be stimulated, and on models of excitation of myelinated nerve fibres. The modelling objectives were to determine the electric field that would be generated within a nerve trunk by a specific electrode. Moreover, the extent of initial excitation of the nerve fibres within the superficial region of the dog sciatic nerve elicited by a certain discrete stimulating electrode was predicted. For this purpose a calculation of activating function for six positions where the nerve fibres were supposed to lie within the longitudinally dissected sciatic nerve was performed. In two acute experiments on the sciatic nerve of the dog the objective was to characterize the effectiveness of the multielectrode system in monopolar selective stimulation of the superficial regions, innervating the gastrocnemius and tibialis anterior muscle. A selectivity preliminary tested by measuring the myoelectric activity of the gastrocnemius and tibialis anterior muscle after 2 months showed good results in both animals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of a Model for Excitation of Myelinated Nerve
McNeal, D. R. (1976) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1976.324593 · Cited by 833
Analysis of Models for External Stimulation of Axons
Rattay, F. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325670 · Cited by 681
A spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415
The Effect of Stimulus Parameters on the Recruitment Characteristics of Direct Nerve Stimulation
Gorman, P. H., & Mortimer, J. T. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325041 · Cited by 313
Selective activation of small motor axons by quasitrapezoidal current pulses
Fang, Z.-P., & Mortimer, J. T. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.76383 · Cited by 222
A nerve cuff technique for selective excitation of peripheral nerve trunk regions
Sweeney, J. D., Ksienski, D. A., & Mortimer, J. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55681 · Cited by 196
Chronically implanted intrafascicular recording electrodes
Lefurge, T., Goodall, E., Horch, K., Stensaas, L., & Schoenberg, A. (1991) · Annals of Biomedical Engineering · doi:10.1007/bf02368469 · Cited by 172
Waters, R. L., McNeal, D. R., Faloon, W., & Clifford, B. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567050-00016 · Cited by 156
A modeling study of nerve fascicle stimulation
Veltink, P. H., van Veen, B. K., Struijk, J. J., Holsheimer, J., & Boom, H. B. K. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.32100 · Cited by 95
Bowman, B. R., & Erickson, R. C. (1985) · Annals of Biomedical Engineering · doi:10.1007/bf02371251 · Cited by 66
Multielectrode intrafascicular and extraneural stimulation
Veltink, P. H., van Alsté, J. A., & Boom, H. B. K. (1989) · Medical and Biological Engineering and Computing · doi:10.1007/bf02442165 · Cited by 62
Electrical stimulation of peripheral nerve
Swett, J. E., & Bourassa, C. M. (1981) · Electrical Stimulation Research Techniques · doi:10.1016/b978-0-12-547440-5.50016-4 · Cited by 39
Cited by
Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve
Branner, A., Stein, R. B., Fernandez, E., Aoyagi, Y., & Normann, R. A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820321 · Cited by 301
Maynard, E. M. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.145 · Cited by 126
Tarler, M. D., & Mortimer, J. T. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.828415 · Cited by 110
Neuromuscular stimulation selectivity of multiple-contact nerve cuff electrode arrays
Sweeney, J. D., Crawford, N. R., & Brandon, T. A. (1995) · Medical & Biological Engineering & Computing · doi:10.1007/bf02510525 · Cited by 51
How to Use Nerve Cuffs to Stimulate, Record or Modulate Neural Activity
Hoffer, J.-A., & Kallesøe, K. (2000) · Frontiers in Neuroscience · doi:10.1201/9781420039054.ch5 · Cited by 21
Metadata
- Authors
- Rozman, J., & Trlep, M.
- Venue
- Journal of Medical Engineering & Technology
- Publisher
- Informa UK Limited
- Published
- 1992-01
- Volume
- 16
- Issue
- 5
- Pages
- 194-203
- ISSN
- 0309-1902 (ISSN-L)
- 1464-522X
- OpenAlex
- W2045676377
- Cited by
- 21
- References
- 12
- FWCI
- 0.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.