Translating Research on Myoelectric Control into Clinics—Are the Performance Assessment Methods Adequate?
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Missing an upper limb dramatically impairs daily-life activities. Efforts in overcoming the issues arising from this disability have been made in both academia and industry, although their clinical outcome is still limited. Translation of prosthetic research into clinics has been challenging because of the difficulties in meeting the necessary requirements of the market. In this perspective article, we suggest that one relevant factor determining the relatively small clinical impact of myocontrol algorithms for upper limb prostheses is the limit of commonly used laboratory performance metrics. The laboratory conditions, in which the majority of the solutions are being evaluated, fail to sufficiently replicate real-life challenges. We qualitatively support this argument with representative data from seven transradial amputees. Their ability to control a myoelectric prosthesis was tested by measuring the accuracy of offline EMG signal classification, as a typical laboratory performance metrics, as well as by clinical scores when performing standard tests of daily living. Despite all subjects reaching relatively high classification accuracy offline, their clinical scores varied greatly and were not strongly predicted by classification accuracy. We therefore support the suggestion to test myocontrol systems using clinical tests on amputees, fully fitted with sockets and prostheses highly resembling the systems they would use in daily living, as evaluation benchmark. Agreement on this level of testing for systems developed in research laboratories would facilitate clinically relevant progresses in this field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The information capacity of the human motor system in controlling the amplitude of movement.
Fitts, P. M. (1954) · Journal of Experimental Psychology · doi:10.1037/h0055392 · Cited by 6,466 · cited 1×
“Further, the Fitts’ law (Fitts, 1954) has also been applied in evaluating myocontrol.”
MethodKuiken, T. A., Dumanian, G. A., Lipschutz, R. D., Miller, L. A., & Stubblefield, K. A. (2004) · Prosthetics & Orthotics International · doi:10.3109/03093640409167756 · Cited by 583 · cited 2×
“…fusion algorithms (Weir et al., 2003; Dosen et al., 2010; Cipriani et al., 2014; Ortenzi et al., 2015; Nissler et al., 2016), surgical techniques (Kuiken et al., 2004; Aszmann et al., 2015), as well as advanced hardware (Cipriani et al., 2011; Grebenstein et al., 2011; Catalano et al., 2014).”
MethodOrtiz-Catalan, M., Håkansson, B., & Brånemark, R. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008933 · Cited by 484 · cited 2×
“…same arm position as the training, as more commonly done in laboratory tests (e.g., Englehart et al., 1999; Hargrove et al., 2009; Li et al., 2010; Ortiz-Catalan et al., 2014b), the resulting offline classification rates were high and comparable to those reported in the literature (>90% on…”
BackgroundResultQuantifying Pattern Recognition—Based Myoelectric Control of Multifunctional Transradial Prostheses
Li, G., Schultz, A. E., & Kuiken, T. A. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039619 · Cited by 443 · cited 2×
“When the offline evaluation was performed by using data collected without wearing the prosthesis and tested on the same arm position as the training, as more commonly done in laboratory tests (e.g., Englehart et al., 1999; Hargrove et al., 2009; Li et al., 2010; Ortiz-Catalan et al., 2014b), the resulting offline clas…”
ResultLight, C. M., Chappell, P. H., & Kyberd, P. J. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2002.32737 · Cited by 417 · cited 1×
“The Southampton Hand Assessment Protocol (SHAP) is one of the most elaborate hand impairment evaluation tests (Light et al., 2002).”
MethodThe SmartHand transradial prosthesis
Cipriani, C., Controzzi, M., & Carrozza, M. C. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-29 · Cited by 286
Jiang, N., Rehbaum, H., Vujaklija, I., Graimann, B., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2278411 · Cited by 269 · cited 7×
“, controlling a cursor to hit targets on a computer screen (Ameri et al., 2014; Jiang et al., 2014a).”
BackgroundMethodSelf-citationOrtiz-Catalan, M., Brånemark, R., & Håkansson, B. (2013) · Source Code for Biology and Medicine · doi:10.1186/1751-0473-8-11 · Cited by 232
Aszmann, O. C., Roche, A. D., Salminger, S., Paternostro-Sluga, T., Herceg, M., Sturma, A., Hofer, C., & Farina, D. (2015) · The Lancet · doi:10.1016/s0140-6736(14)61776-1 · Cited by 152
Self-citation
Research works printed but not linked: 37
- Ahsan, 2010, Advances in electromyogram signal classification to improve the quality of life for the disabled and aged people, J. Comput. Sci., 6, 706, 10.3844/jcssp.2010.706.715 · DOI
- Ameri, 2014, Real-time, simultaneous myoelectric control using force and position-based training paradigms, IEEE Trans. Biomed. Eng., 61, 279, 10.1109/tbme.2013.2281595 · DOI
- Amsuess, 2016, Context-dependent upper limb prosthesis control for natural and robust use, IEEE Trans. Neural Syst. Rehabil. Eng., 24, 744, 10.1109/TNSRE.2015.2454240 · DOI · Paper page
- Aszmann, 2016, Elective amputation and bionic substitution restore functional hand use after critical soft tissue injuries, Sci. Rep., 6, 34960, 10.1038/srep34960 · DOI
- Burrough, 1985, Patterns of acceptance and rejection of upper limb prostheses, Orthot. Prosthet., 39, 40
- Catalano, 2014, Adaptive synergies for the design and control of the Pisa/IIT SoftHand, Int. J. Robot. Res., 33, 768, 10.1177/0278364913518998 · DOI · Paper page
- Cipriani, 2014, Dexterous control of a prosthetic hand using fine-wire intramuscular electrodes in targeted extrinsic muscles, IEEE Trans. Neural Syst. Rehabil. Eng., 22, 828, 10.1109/TNSRE.2014.2301234 · DOI · Paper page
- Daly, 2014, Socket pressure and discomfort in upper-limb prostheses: a preliminary study, J. Prosthet. Orthot., 26, 99, 10.1097/jpo.0000000000000021 · DOI
- Davis Sears, 2010, Validity and responsiveness of the Jebsen-Taylor hand function test, J. Hand Surg. Am., 35, 30, 10.1016/j.jhsa.2009.09.008 · doi:10.1016/j.jhsa.2009.09.008
- Dosen, 2010, Cognitive vision system for control of dexterous prosthetic hands: experimental evaluation, J. Neuroeng. Rehabil., 7, 42, 10.1186/1743-0003-7-42 · DOI · Paper page
- Englehart, 1999, Classification of the myoelectric signal using time-frequency based representations, Med. Eng. Phys., 21, 431, 10.1016/s1350-4533(99)00066-1 · DOI · Paper page
- Farina, 2014, Bionic limbs: clinical reality and academic promises, Sci. Transl. Med., 6, 257ps12, 10.1126/scitranslmed.3010453 · DOI · Paper page
- Fimbel, 2006, Speed-accuracy trade-offs in myocontrol, Hum. Mov. Sci., 25, 165, 10.1016/j.humov.2005.12.001 · DOI
- Glynn, 1986, Management of the upper-limb-deficient child with a powered prosthetic device, Clin. Orthop. Relat. Res., 209, 202, 10.1097/00003086-198608000-00029 · DOI
- Gonzalez, 2009, Multichannel audio aided dynamical perception for prosthetic hand biofeedback, 240
- Grebenstein, 2011, The DLR hand arm system, 3175
- Hargrove, 2009, Principal components analysis preprocessing to improve classification accuracies in pattern recognition based myoelectric control, IEEE Trans. Biomed. Eng., 56, 1407, 10.1109/TBME.2008.2008171 · DOI · Paper page
- Hermansson, 2005, Assessment of capacity for myoelectric control: a new Rasch-built measure of prosthetic hand control, J. Rehabil. Med., 37, 166, 10.1080/16501970410024280 · DOI · Paper page
- Hill, 2009, Functional outcomes in the WHO-ICF model: establishment of the upper limb prosthetic outcome measures group, J. Prosthet. Orthot., 21, 115, 10.1097/jpo.0b013e3181a1d2dc · DOI
- Ison, 2016, High-density electromyography and motor skill learning for robust long-term control of a 7-DoF Robot Arm, IEEE Trans. Neural Syst. Rehabil. Eng., 24, 424, 10.1109/TNSRE.2015.2417775 · DOI
- Jiang, 2012, Myoelectric control of artificial—is there a need to change focus?, IEEE Signal Process. Mag., 29, 150, 10.1109/MSP.2012.2203480 · DOI · Paper page
- Jiang, 2014b, Is accurate mapping of EMG signals on kinematics needed for precise online myoelectric control?, IEEE Trans. Neural Syst. Rehabil. Eng., 22, 549, 10.1109/TNSRE.2013.2287383 · DOI · Paper page
- Jorgovanovic, 2014, Virtual grasping: closed-loop force control using electrotactile feedback, Comput. Math. Methods Med., 2014, 120357, 10.1155/2014/120357 · DOI · Paper page
- Liu, 2013, Electromyogram whitening for improved classification accuracy in upper limb prosthesis control, IEEE Trans. Neural Syst. Rehabil. Eng., 21, 767, 10.1109/TNSRE.2013.2243470 · DOI
- Nissler, 2016, Optical myography: detecting finger movements by looking at the forearm, Front. Neurorobot., 10, 3, 10.3389/fnbot.2016.00003 · DOI
- Ortenzi, 2015, Ultrasound imaging for hand prosthesis control: a comparative study of features and classification methods, 1, 10.1109/ICORR.2015.7281166 · DOI
- Ortiz-Catalan, 2014b, Real-time and simultaneous control of artificial limbs based on pattern recognition algorithms, IEEE Trans. Neural Syst. Rehabil. Eng., 22, 756, 10.1109/TNSRE.2014.2305097 · DOI · Paper page
- Ortiz-Catalan, 2015, Offline accuracy: a potentially misleading metric in myoelectric pattern recognition for prosthetic control, Conf. Proc. IEEE Eng. Med. Biol. Soc., 2015, 1140, 10.1109/EMBC.2015.7318567 · DOI · Paper page
- Østlie, 2012, Prosthesis rejection in acquired major upper-limb amputees: a population-based survey, Disabil. Rehabil. Assist. Technol., 7, 294, 10.3109/17483107.2011.635405 · DOI · Paper page
- Park, 2008, EMG—force correlation considering Fitts’ law, 644
- Roche, 2015, A structured rehabilitation protocol for improved multifunctional prosthetic control: a case study, J. Vis. Exp., 6, e52968, 10.3791/52968 · DOI
- Scheme, 2011, Electromyogram pattern recognition for control of powered upper-limb prostheses: state of the art and challenges for clinical use, J. Rehabil. Res. Dev., 48, 643, 10.1682/jrrd.2010.09.0177 · DOI · Paper page
- Scheme, 2013, Validation of a selective ensemble-based classification scheme for myoelectric control using a three-dimensional fitts’ law test, IEEE Trans. Neural Syst. Rehabil. Eng., 21, 616, 10.1109/TNSRE.2012.2226189 · DOI · Paper page
- Simon, 2011, Target achievement control test: evaluating real-time myoelectric pattern-recognition control of multifunctional upper-limb prostheses, J. Rehabil. Res. Dev., 48, 619, 10.1682/jrrd.2010.08.0149 · DOI · Paper page
- Stubblefield, 2011, Training individuals to use pattern recognition to control an upper limb prosthesis, 170
- Sturma, 2015, A surface EMG test tool to measure proportional prosthetic control, Biomed. Tech. (Berl), 60, 207, 10.1515/bmt-2014-0022 · doi:10.1515/bmt-2014-0022
- Weir, 2003, Implantable myoelectric sensors (IMES) for upper-extremity prosthesis control- preliminary work, 1562
Cited by
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Self-citationJaramillo-Yánez, A., Benalcázar, M. E., & Mena-Maldonado, E. (2020) · Sensors · doi:10.3390/s20092467 · Cited by 259
Hargrove, L. J., Miller, L. A., Turner, K., & Kuiken, T. A. (2017) · Scientific Reports · doi:10.1038/s41598-017-14386-w · Cited by 190
Salminger, S., Sturma, A., Hofer, C., Evangelista, M., Perrin, M., Bergmeister, K. D., Roche, A. D., Hasenoehrl, T., Dietl, H., Farina, D., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aaw6306 · Cited by 139
Self-citationMastinu, E., Ahlberg, J., Lendaro, E., Hermansson, L., Hakansson, B., & Ortiz-Catalan, M. (2018) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2018.2811458 · Cited by 48
Metadata
- Authors
- Vujaklija, I., Roche, A. D., Hasenoehrl, T., Sturma, A., Amsuess, S., Farina, D., & Aszmann, O. C.
- Venue
- Frontiers in Neurorobotics
- Publisher
- Frontiers Media SA
- Published
- 2017-02-14
- Volume
- 11
- Pages
- 7-7
- ISSN
- 1662-5218 (ISSN-L)
- OpenAlex
- W2588656139
- Cited by
- 96
- References
- 9
- FWCI
- 5.47
- Type
- journal article
- Language
- en
- Open access
- gold
- Funders
- Horizon 2020 Framework Programme
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.