CoChat

Translating Research on Myoelectric Control into Clinics—Are the Performance Assessment Methods Adequate?

Open access
Vujaklija, Ivan, Roche, Aidan D., Hasenoehrl, Timothy, Sturma, Agnes, Amsuess, Sebastian, Farina, Dario, Aszmann, Oskar C. · 2017 · Frontiers in Neurorobotics
Cited by 96

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Missing an upper limb dramatically impairs daily-life activities. Efforts in overcoming the issues arising from this disability have been made in both academia and industry, although their clinical outcome is still limited. Translation of prosthetic research into clinics has been challenging because of the difficulties in meeting the necessary requirements of the market. In this perspective article, we suggest that one relevant factor determining the relatively small clinical impact of myocontrol algorithms for upper limb prostheses is the limit of commonly used laboratory performance metrics. The laboratory conditions, in which the majority of the solutions are being evaluated, fail to sufficiently replicate real-life challenges. We qualitatively support this argument with representative data from seven transradial amputees. Their ability to control a myoelectric prosthesis was tested by measuring the accuracy of offline EMG signal classification, as a typical laboratory performance metrics, as well as by clinical scores when performing standard tests of daily living. Despite all subjects reaching relatively high classification accuracy offline, their clinical scores varied greatly and were not strongly predicted by classification accuracy. We therefore support the suggestion to test myocontrol systems using clinical tests on amputees, fully fitted with sockets and prostheses highly resembling the systems they would use in daily living, as evaluation benchmark. Agreement on this level of testing for systems developed in research laboratories would facilitate clinically relevant progresses in this field.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3389/fnbot.2017.00007

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 37

  1. Ahsan, 2010, Advances in electromyogram signal classification to improve the quality of life for the disabled and aged people, J. Comput. Sci., 6, 706, 10.3844/jcssp.2010.706.715 · DOI
  2. Ameri, 2014, Real-time, simultaneous myoelectric control using force and position-based training paradigms, IEEE Trans. Biomed. Eng., 61, 279, 10.1109/tbme.2013.2281595 · DOI
  3. Amsuess, 2016, Context-dependent upper limb prosthesis control for natural and robust use, IEEE Trans. Neural Syst. Rehabil. Eng., 24, 744, 10.1109/TNSRE.2015.2454240 · DOI · Paper page
  4. Aszmann, 2016, Elective amputation and bionic substitution restore functional hand use after critical soft tissue injuries, Sci. Rep., 6, 34960, 10.1038/srep34960 · DOI
  5. Burrough, 1985, Patterns of acceptance and rejection of upper limb prostheses, Orthot. Prosthet., 39, 40
  6. Catalano, 2014, Adaptive synergies for the design and control of the Pisa/IIT SoftHand, Int. J. Robot. Res., 33, 768, 10.1177/0278364913518998 · DOI · Paper page
  7. Cipriani, 2014, Dexterous control of a prosthetic hand using fine-wire intramuscular electrodes in targeted extrinsic muscles, IEEE Trans. Neural Syst. Rehabil. Eng., 22, 828, 10.1109/TNSRE.2014.2301234 · DOI · Paper page
  8. Daly, 2014, Socket pressure and discomfort in upper-limb prostheses: a preliminary study, J. Prosthet. Orthot., 26, 99, 10.1097/jpo.0000000000000021 · DOI
  9. Davis Sears, 2010, Validity and responsiveness of the Jebsen-Taylor hand function test, J. Hand Surg. Am., 35, 30, 10.1016/j.jhsa.2009.09.008 · doi:10.1016/j.jhsa.2009.09.008
  10. Dosen, 2010, Cognitive vision system for control of dexterous prosthetic hands: experimental evaluation, J. Neuroeng. Rehabil., 7, 42, 10.1186/1743-0003-7-42 · DOI · Paper page
  11. Englehart, 1999, Classification of the myoelectric signal using time-frequency based representations, Med. Eng. Phys., 21, 431, 10.1016/s1350-4533(99)00066-1 · DOI · Paper page
  12. Farina, 2014, Bionic limbs: clinical reality and academic promises, Sci. Transl. Med., 6, 257ps12, 10.1126/scitranslmed.3010453 · DOI · Paper page
  13. Fimbel, 2006, Speed-accuracy trade-offs in myocontrol, Hum. Mov. Sci., 25, 165, 10.1016/j.humov.2005.12.001 · DOI
  14. Glynn, 1986, Management of the upper-limb-deficient child with a powered prosthetic device, Clin. Orthop. Relat. Res., 209, 202, 10.1097/00003086-198608000-00029 · DOI
  15. Gonzalez, 2009, Multichannel audio aided dynamical perception for prosthetic hand biofeedback, 240
  16. Grebenstein, 2011, The DLR hand arm system, 3175
  17. Hargrove, 2009, Principal components analysis preprocessing to improve classification accuracies in pattern recognition based myoelectric control, IEEE Trans. Biomed. Eng., 56, 1407, 10.1109/TBME.2008.2008171 · DOI · Paper page
  18. Hermansson, 2005, Assessment of capacity for myoelectric control: a new Rasch-built measure of prosthetic hand control, J. Rehabil. Med., 37, 166, 10.1080/16501970410024280 · DOI · Paper page
  19. Hill, 2009, Functional outcomes in the WHO-ICF model: establishment of the upper limb prosthetic outcome measures group, J. Prosthet. Orthot., 21, 115, 10.1097/jpo.0b013e3181a1d2dc · DOI
  20. Ison, 2016, High-density electromyography and motor skill learning for robust long-term control of a 7-DoF Robot Arm, IEEE Trans. Neural Syst. Rehabil. Eng., 24, 424, 10.1109/TNSRE.2015.2417775 · DOI
  21. Jiang, 2012, Myoelectric control of artificial—is there a need to change focus?, IEEE Signal Process. Mag., 29, 150, 10.1109/MSP.2012.2203480 · DOI · Paper page
  22. Jiang, 2014b, Is accurate mapping of EMG signals on kinematics needed for precise online myoelectric control?, IEEE Trans. Neural Syst. Rehabil. Eng., 22, 549, 10.1109/TNSRE.2013.2287383 · DOI · Paper page
  23. Jorgovanovic, 2014, Virtual grasping: closed-loop force control using electrotactile feedback, Comput. Math. Methods Med., 2014, 120357, 10.1155/2014/120357 · DOI · Paper page
  24. Liu, 2013, Electromyogram whitening for improved classification accuracy in upper limb prosthesis control, IEEE Trans. Neural Syst. Rehabil. Eng., 21, 767, 10.1109/TNSRE.2013.2243470 · DOI
  25. Nissler, 2016, Optical myography: detecting finger movements by looking at the forearm, Front. Neurorobot., 10, 3, 10.3389/fnbot.2016.00003 · DOI
  26. Ortenzi, 2015, Ultrasound imaging for hand prosthesis control: a comparative study of features and classification methods, 1, 10.1109/ICORR.2015.7281166 · DOI
  27. Ortiz-Catalan, 2014b, Real-time and simultaneous control of artificial limbs based on pattern recognition algorithms, IEEE Trans. Neural Syst. Rehabil. Eng., 22, 756, 10.1109/TNSRE.2014.2305097 · DOI · Paper page
  28. Ortiz-Catalan, 2015, Offline accuracy: a potentially misleading metric in myoelectric pattern recognition for prosthetic control, Conf. Proc. IEEE Eng. Med. Biol. Soc., 2015, 1140, 10.1109/EMBC.2015.7318567 · DOI · Paper page
  29. Østlie, 2012, Prosthesis rejection in acquired major upper-limb amputees: a population-based survey, Disabil. Rehabil. Assist. Technol., 7, 294, 10.3109/17483107.2011.635405 · DOI · Paper page
  30. Park, 2008, EMG—force correlation considering Fitts’ law, 644
  31. Roche, 2015, A structured rehabilitation protocol for improved multifunctional prosthetic control: a case study, J. Vis. Exp., 6, e52968, 10.3791/52968 · DOI
  32. Scheme, 2011, Electromyogram pattern recognition for control of powered upper-limb prostheses: state of the art and challenges for clinical use, J. Rehabil. Res. Dev., 48, 643, 10.1682/jrrd.2010.09.0177 · DOI · Paper page
  33. Scheme, 2013, Validation of a selective ensemble-based classification scheme for myoelectric control using a three-dimensional fitts’ law test, IEEE Trans. Neural Syst. Rehabil. Eng., 21, 616, 10.1109/TNSRE.2012.2226189 · DOI · Paper page
  34. Simon, 2011, Target achievement control test: evaluating real-time myoelectric pattern-recognition control of multifunctional upper-limb prostheses, J. Rehabil. Res. Dev., 48, 619, 10.1682/jrrd.2010.08.0149 · DOI · Paper page
  35. Stubblefield, 2011, Training individuals to use pattern recognition to control an upper limb prosthesis, 170
  36. Sturma, 2015, A surface EMG test tool to measure proportional prosthetic control, Biomed. Tech. (Berl), 60, 207, 10.1515/bmt-2014-0022 · doi:10.1515/bmt-2014-0022
  37. Weir, 2003, Implantable myoelectric sensors (IMES) for upper-extremity prosthesis control- preliminary work, 1562

Cited by

See all 96

Metadata

Authors
Vujaklija, I., Roche, A. D., Hasenoehrl, T., Sturma, A., Amsuess, S., Farina, D., & Aszmann, O. C.
Venue
Frontiers in Neurorobotics
Published
2017-02-14
Volume
11
Pages
7-7
ISSN
1662-5218 (ISSN-L)
OpenAlex
W2588656139
Cited by
96
References
9
FWCI
5.47
Type
journal article
Language
en
Open access
gold
Funders
Horizon 2020 Framework Programme

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.