The DOI matches its Crossref record; 26 of the 27 references it cites were found in a registry or an index.
Interim results of a multicenter trial with the new electronic subretinal implant Alpha AMS in 15 Patients blind from inherited retinal degenerations.
Open accessAbstract
Purpose: We assessed the safety and efficacy of a technically advanced subretinal electronic implant, RETINA IMPLANT Alpha AMS, in end stage retinal degeneration in an interim analysis of two ongoing prospective clinical trials. Methods: The subretinal visual prosthesis RETINA IMPLANT Alpha AMS (Retina Implant AG, Reutlingen, Germany) was implanted in 15 blind patients with hereditary retinal degenerations at four study sites with a follow-up period of 12 months (www.clinicaltrials.gov NCT01024803 and NCT02720640). Functional outcome measures included 1) screen-based standardized 2- or 4-alternative forced-choice tests of light perception, light localization, grating detection (basic grating acuity (BaGA) test) and Landolt C-rings; 2) grey level discrimination; 3) performance during activities of daily living (ADL-table tasks). Results: Implant-mediated light perception was observed in 13/15 patients. During the observation period implant mediated localization of visual targets was possible in 13/15 patients. Correct grating detection was achieved for spatial frequencies of 0.1 cpd (cycles per degree) in 4/15; 0.33 cpd in 3/15; 0.66 cpd in 2/15; 1.0 cpd in 2/15 and 3.3 cpd in 1/15 patients. In two patients visual acuity assessed with Landolt C- rings was 20/546 and 20/1111. Of 6 possible grey levels on average 4.6 +/-0.8 (mean +/- SD, n=10) were discerned. Improvements (power ON vs. OFF) of ADL table tasks were measured in 13/15 patients. Overall, results were stable during the observation period. Serious adverse events were reported in 4 patients: 2 movements of the implant, readjusted in a second surgery; 4 conjunctival erosion/dehiscence, successfully treated; 1 pain event around the coil, successfully treated; 1 partial reduction of silicone oil tamponade leading to distorted vision (silicon oil successfully refilled). The majority of adverse events were transient and mostly of mild to moderate intensity. Conclusions: Psychophysical and subjective data show that RETINA IMPLANT Alpha AMS is reliable, well tolerated and can restore limited visual functions in blind patients with degenerations of the outer retina. Compared with the previous implant Alpha IMS, longevity of the new implant Alpha AMS has been considerably improved. Alpha AMS has meanwhile been certified as a commercially available medical device, reimbursed in Germany by the public health system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“At present, retinal prostheses are the most successful approach in this field, and several retinal devices have already been approved for patients with retinal dystrophies (Da Cruz et al., 2016; Stingl et al., 2017).”
From Toward Long-Term Communication With the Brain in the Blind by Intracortical Stimulation: Challenges and Future Prospects (2020) · cites this paper as Stingl et al., 2017
In the citing paper
“several research groups are focusing their efforts on the development of new approaches for artificial vision based on electric stimulation of the retina”
From Toward Long-Term Communication With the Brain in the Blind by Intracortical Stimulation: Challenges and Future Prospects (2020) · cites this paper as Stingl et al., 2017
In the citing paper
“At present, retinal prostheses are the most successful approach in this field, and several retinal devices have already been approved for patients with retinal dystrophies (Da Cruz et al., 2016; Stingl et al., 2017).”
From Toward Long-Term Communication With the Brain in the Blind by Intracortical Stimulation: Challenges and Future Prospects (2020) · cites this paper as Stingl et al., 2017
In the citing paper
“The best documented grating visual acuity with Alpha AMS has been equivalent to around 0.95 logMAR (6/60 Snellen), although significant variations exist over time and between patients [Stingl 2017; Edwards 2018].”
From Correcting visual loss by genetics and prosthetics (2020) · cites this paper as Stingl 2017
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effect of gene therapy on visual function in Leber’s congenital amaurosis
Bainbridge, J. W. B., Smith, A. J., Barker, S. S., Robbie, S., Henderson, R., Balaggan, K., Viswanathan, A., Holder, G. E., Stockman, A., Tyler, N., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0802268 · Cited by 1,924
Subretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819
MacLaren, R. E., Groppe, M., Barnard, A. R., Cottriall, C. L., Tolmachova, T., Seymour, L., Clark, K. R., During, M. J., Cremers, F. P. M., Black, G. C. M., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(13)62117-0 · Cited by 796
Self-citationInterim results from the international trial of Second Sight's visual prosthesis
Humayun, M. S., Dorn, J. D., da Cruz, L., Dagnelie, G., Sahel, J.-A., Stanga, P. E., Cideciyan, A. V., Duncan, J. L., Eliott, D., Filley, E., et al. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.09.028 · Cited by 700
Retinitis Pigmentosa: Genes and Disease Mechanisms
Parmeggiani, F., Sorrentino, F. S., Ponzin, D., Barbaro, V., Ferrari, S., & Iorio, E. D. (2011) · Current Genomics · doi:10.2174/138920211795860107 · Cited by 663
Artificial vision with wirelessly powered subretinal electronic implant alpha-IMS
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Braun, A., Bruckmann, A., Gekeler, F., Greppmaier, U., Hipp, S., Hörtdörfer, G., Kernstock, C., et al. (2013) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2013.0077 · Cited by 473
Bennett, J., Wellman, J., Marshall, K. A., McCague, S., Ashtari, M., DiStefano-Pappas, J., Elci, O. U., Chung, D. C., Sun, J., Wright, J. F., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(16)30371-3 · Cited by 461
Subretinal visual implant alpha IMS - clinical trial interim report
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Chee, C. K., Cottriall, C. L., Gekeler, F., Groppe, M., Jackson, T. L., MacLaren, R. E., Koitschev, A., et al. (2015) · Vision Research · doi:10.1016/j.visres.2015.03.001 · Cited by 387
First-in-human trial of a novel suprachoroidal retinal prosthesis
Ayton, L. N., Blamey, P. J., Guymer, R. H., Luu, C. D., Nayagam, D. A. X., Sinclair, N. C., Shivdasani, M. N., Yeoh, J., McCombe, M. F., Briggs, R. J., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0115239 · Cited by 333
Long-Term Results from an Epiretinal Prosthesis to Restore Sight to the Blind
Ho, A. C., Humayun, M. S., Dorn, J. D., da Cruz, L., Dagnelie, G., Handa, J. T., Barale, P. O., Sahel, J., Stanga, P. E., Hafezi, F., et al. (2015) · Ophthalmology · doi:10.1016/j.ophtha.2015.04.032 · Cited by 262
Electrical multisite stimulation of the isolated chicken retina
Stett, A., Barth, W., Weiss, S., Haemmerle, H., & Zrenner, E. (2000) · Vision Research · doi:10.1016/s0042-6989(00)00005-5 · Cited by 259
Singh, M. S., Issa, P. C., Butler, R., Martin, C. J., Lipinski, D. M., Sekaran, S., Barnard, A. R., & MacLaren, R. E. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1119416110 · Cited by 258
Optogenetic therapy for retinitis pigmentosa
Busskamp, V., Picaud, S. A., Sahel, J., & Roska, B. (2011) · Gene Therapy · doi:10.1038/gt.2011.155 · Cited by 247
Schatz, A., Röck, T., Naycheva, L., Willmann, G., Wilhelm, B., Peters, T. M., Bartz‐Schmidt, K. U., Zrenner, E., Messias, A. M. V., & Gekeler, F. (2011) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.10-6932 · Cited by 157
Besch, D., Sachs, H., Szurman, P., Gülicher, D., Wilke, R. G. H., Reinert, S., Zrenner, E., Bartz‐Schmidt, K. U., & Gekeler, F. (2008) · British Journal of Ophthalmology · doi:10.1136/bjo.2007.131961 · Cited by 115
A CMOS Chip With Active Pixel Array and Specific Test Features for Subretinal Implantation
Rothermel, A., Liu, L., Aryan, N. P., Fischer, M. D., Wuenschmann, J., Kibbel, S., & Harscher, A. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2007436 · Cited by 109
Schatz, A., Pach, J., Gosheva, M., Naycheva, L., Willmann, G., Wilhelm, B., Peters, T. M., Bartz‐Schmidt, K. U., Zrenner, E., Messias, A. M. V., et al. (2017) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.16-19906 · Cited by 99
Scholl, H. P. N., Moore, A. T., Koenekoop, R. K., Wen, Y., Fishman, G. A., van den Born, L. I., Bittner, A., Bowles, K., Fletcher, E. C., Collison, F. T., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0143846 · Cited by 71
Basic Quantitative Assessment of Visual Performance in Patients with Very Low Vision
Bach, M., Wilke, M., Wilhelm, B., Zrenner, E., & Wilke, R. G. H. (2010) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.09-3512 · Cited by 70
Three dimensional MEMS microfluidic perfusion system for thick brain slice cultures
Choi, Y., McClain, M. A., LaPlaca, M. C., Frazier, A. B., & Allen, M. G. (2006) · Biomedical Microdevices · doi:10.1007/s10544-006-9004-8 · Cited by 65
Stett, A., Mai, A., & Herrmann, T. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/1/s02 · Cited by 59
Safety evaluation of “retina implant alpha IMS”—a prospective clinical trial
Kitiratschky, V. B. D., Štingl, K., Wilhelm, B., Peters, T. M., Besch, D., Sachs, H. G., Gekeler, F., Bartz‐Schmidt, K. U., & Zrenner, E. (2014) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-014-2797-x · Cited by 55
Laboratory and clinical reliability of conformally coated subretinal implants
Daschner, R., Greppmaier, U., Kokelmann, M., Rudorf, S., Rudorf, R., Schleehauf, S., & Wrobel, W. (2017) · Biomedical Microdevices · doi:10.1007/s10544-017-0147-6 · Cited by 40
Testing Visual Functions in Patients with Visual Prostheses
Wilke, R. G. H., Bach, M., Wilhelm, B., Durst, W., Trauzettel‐Klosinski, S., & Zrenner, E. (2007) · Springer eBooks · doi:10.1007/978-0-387-49331-2_5 · Cited by 21
Electronic retinal implant surgery
MacLaren, R. E. (2017) · Eye · doi:10.1038/eye.2016.280 · Cited by 13
Transfer characteristics of subretinal visual implants: corneally recorded implant responses
Štingl, K., Bartz-Schmidt, K. U., Braun, A., Gekeler, F., Greppmaier, U., Schatz, A., Stett, A., Straßer, T., Kitiratschky, V. B. D., & Zrenner, E. (2016) · Documenta Ophthalmologica · doi:10.1007/s10633-016-9557-7 · Cited by 10
Flagged first, then by citations
1 of the 27 references couldn’t be matched to a known paper.
Research works printed but not linked: 2
- Kernstock, 2011, 3D-visualisation of power supply cable of subretinal electronic implants during eye movement. [Abstract], Invest. Ophthalmol. Vis. Sci., 52, 1341
- Sachs, 2010, Subretinal implant: the intraocular implantation technique, Nova Acta Leopoldina NF III, 379, 217
Cited by
Sorted by citations
Age-related macular degeneration
Mitchell, P., Liew, G., Gopinath, B., & Wong, T. Y. (2018) · The Lancet · doi:10.1016/s0140-6736(18)31550-2 · Cited by 1,511
Non-syndromic retinitis pigmentosa
Verbakel, S. K., van Huet, R. A. C., Boon, C. J. F., den Hollander, A. I., Collin, R. W. J., Klaver, C. C. W., Hoyng, C. B., Roepman, R., & Klevering, B. J. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.03.005 · Cited by 973
The Argus® II Retinal Prosthesis System
Luo, Y. H.-L., & da Cruz, L. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.09.003 · Cited by 351
Photovoltaic Restoration of Central Vision in Atrophic Age-Related Macular Degeneration
Palanker, D., Le Mer, Y., Mohand-Said, S., Muqit, M., & Sahel, J. A. (2020) · Ophthalmology · doi:10.1016/j.ophtha.2020.02.024 · Cited by 227
An update on retinal prostheses
Ayton, L. N., Barnes, N., Dagnelie, G., Fujikado, T., Goetz, G., Hornig, R., Jones, B. W., Muqit, M. M. K., Rathbun, D. L., Stingl, K., et al. (2020) · Clinical Neurophysiology · doi:10.1016/j.clinph.2019.11.029 · Cited by 223
Metadata
- Authors
- Stingl, K., Schippert, R., Bartz-Schmidt, K. U., Besch, D., Cottriall, C. L., Edwards, T. L., Gekeler, F., Greppmaier, U., Kiel, K., Koitschev, A., Kühlewein, L., MacLaren, R. E., Ramsden, J. D., Roider, J., Rothermel, A., Sachs, H., Schröder, G. S., Tode, J., Troelenberg, N., & Zrenner, E.
- Affiliations
- University of Tübingen (DE)
- University of Oxford (GB)
- Katharinenhospital (DE)
- Städtisches Klinikum Dresden (DE)
- Olgahospital (DE)
- Christian-Albrechts-Universität zu Kiel (DE)
- Universität Ulm (DE)
- Venue
- Frontiers in Neuroscience
- Publisher
- Frontiers Media SA
- Published
- 2017-08-23
- Volume
- 11
- Pages
- 445-445
- ISSN
- 1662-453X (ISSN-L)
- PMC
- PMC5572402
- OpenAlex
- W2748114767
- Cited by
- 198
- References
- 27
- Citations by year
- 2026: 21 · 2025: 15 · 2024: 17 · 2023: 21 · 2022: 22 · 2021: 28 · 2020: 29 · 2019: 23 · 2018: 20 · 2017: 1
- FWCI
- 9.76
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- Frontiers in Neuroscience (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Minerva Access (University of Melbourne) (submittedVersion, cc-by)
- Multimedialen Archiv und Publikationsserver der Christian-Albrechts-Universität zu Kiel (Christian-Albrechts-Universität zu Kiel) (submittedVersion, cc-by)
- OPen Access Repositorium der Universität Ulm (OPARU) (Ulm University) (submittedVersion, cc-by)
- Universität Ulm, Kommunikations- und Informationszentrum (kiz) (cc-by)
- Funders
- National Institute for Health and Care Research (II-C2-0713-20005)
- University of Oxford
- Bundesministerium für Bildung und Forschung (FKZ 01GQ1002, 01GQ1002)
- Oxford University Hospitals NHS Foundation Trust
- Invention for Innovation
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Ophthalmology › Retinal Development and Disorders
- Health Sciences › Medicine › Ophthalmology › Retinal Diseases and Treatments
- Keywords
- inherited retinal degeneration, light perception, light localization, grating detection, Landolt C, activities of daily living, implant safety, conjunctival erosion, silicone oil tamponade
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review