The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Microvalves and Micropumps for BioMEMS
Open accessAbstract
This review presents an extensive overview of a large number of microvalve and micropump designs with great variability in performance and operation. The performance of a given design varies greatly depending on the particular assembly procedure and there is no standardized performance test against which all microvalves and micropumps can be compared. We present the designs with a historical perspective and provide insight into their advantages and limitations for biomedical uses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Functional hydrogel structures for autonomous flow control inside microfluidic channels
Beebe, D. J., Moore, J. S., Bauer, J. M., Yu, Q., Liu, R. H., Devadoss, C., & Jo, B.-H. (2000) · Nature · doi:10.1038/35007047 · Cited by 1,971
Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip
Harrison, D. J., Fluri, K., Seiler, K., Fan, Z., Effenhauser, C. S., & Manz, A. (1993) · Science · doi:10.1126/science.261.5123.895 · Cited by 1,800
Cho, S. K., Moon, H., & Kim, C.-J. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.807467 · Cited by 1,598
Electrowetting-based actuation of liquid droplets for microfluidic applications
Pollack, M. G., Fair, R. B., & Shenderov, A. D. (2000) · Applied Physics Letters · doi:10.1063/1.1308534 · Cited by 1,481
A controlled-release microchip
Santini, J. T., Cima, M. J., & Langer, R. (1999) · Nature · doi:10.1038/16898 · Cited by 868
Centrifugal microfluidics for biomedical applications
Gorkin, R., Park, J., Siegrist, J., Amasia, M., Lee, B. S., Park, J.-M., Kim, J., Kim, H., Madou, M., & Cho, Y.-K. (2010) · Lab on a Chip · doi:10.1039/b924109d · Cited by 731
Electrowetting and electrowetting-on-dielectric for microscale liquid handling
Lee, J., Moon, H., Fowler, J., Schoellhammer, T., & Kim, C.-J. (2002) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(01)00734-8 · Cited by 652
A piezoelectric micropump based on micromachining of silicon
van Lintel, H. T. G., van De Pol, F. C. M., & Bouwstra, S. (1988) · Sensors and Actuators · doi:10.1016/0250-6874(88)87005-7 · Cited by 620
Grover, W. H., Skelley, A. M., Liu, C. N., Lagally, E. T., & Mathies, R. A. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00468-9 · Cited by 517
An Integrated Microfabricated Cell Sorter
Fu, A. Y., Chou, H.-P., Spence, C., Arnold, F. H., & Quake, S. R. (2002) · Analytical Chemistry · doi:10.1021/ac0255330 · Cited by 510
Autonomous Microfluidic Capillary System
Juncker, D., Schmid, H., Drechsler, U., Wolf, H., Wolf, M., Michel, B., de Rooij, N., & Delamarche, E. (2002) · Analytical Chemistry · doi:10.1021/ac0261449 · Cited by 426
A passive pumping method for microfluidic devices
Walker, G. M., & Beebe, D. J. (2002) · Lab on a Chip · doi:10.1039/b204381e · Cited by 420
An AC magnetohydrodynamic micropump
Lemoff, A. V., & Lee, A. P. (2000) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(00)00355-5 · Cited by 415
Computerized microfluidic cell culture using elastomeric channels and Braille displays
Gu, W., Zhu, X., Futai, N., Cho, B. S., & Takayama, S. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0404353101 · Cited by 403
Micropumps, microvalves, and micromixers within PCR microfluidic chips: Advances and trends
Zhang, C., Xing, D., & Li, Y. (2007) · Biotechnology Advances · doi:10.1016/j.biotechadv.2007.05.003 · Cited by 376
Du, W., Li, L., Nichols, K. P., & Ismagilov, R. F. (2009) · Lab on a Chip · doi:10.1039/b908978k · Cited by 351
Generating Electrospray from Microchip Devices Using Electroosmotic Pumping
Ramsey, R. S., & Ramsey, J. M. (1997) · Analytical Chemistry · doi:10.1021/ac9610671 · Cited by 350
Digital microfluidics for cell-based assays
Barbulovic-Nad, I., Yang, H., Park, P. S., & Wheeler, A. R. (2008) · Lab on a Chip · doi:10.1039/b717759c · Cited by 337
How the capillary burst microvalve works
Cho, H., Kim, H.-Y., Kang, J. Y., & Kim, T. S. (2007) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2006.10.077 · Cited by 298
Shen, F., Du, W., Kreutz, J. E., Fok, A., & Ismagilov, R. F. (2010) · Lab on a Chip · doi:10.1039/c004521g · Cited by 295
Responsive biomimetic hydrogel valve for microfluidics
Yu, Q., Bauer, J. M., Moore, J. S., & Beebe, D. J. (2001) · Applied Physics Letters · doi:10.1063/1.1367010 · Cited by 262
Hosokawa, K., Sato, K., Ichikawa, N., & Maeda, M. (2004) · Lab on a Chip · doi:10.1039/b403930k · Cited by 260
Grover, W. H., Ivester, R. H. C., Jensen, E. C., & Mathies, R. A. (2006) · Lab on a Chip · doi:10.1039/b518362f · Cited by 253
A microfluidic platform for complete mammalian cell culture
Barbulovic-Nad, I., Au, S. H., & Wheeler, A. R. (2010) · Lab on a Chip · doi:10.1039/c002147d · Cited by 249
Generating Electrospray from Microchip Devices Using Electroosmotic Pumping
Ramsey, R. S., & Ramsey, J. M. (1997) · Analytical Chemistry · doi:10.1021/ac971475k · Cited by 209
Torque-Actuated Valves for Microfluidics
Weibel, D. B., Kruithof, M., Potenta, S., Sia, S. K., Lee, A., & Whitesides, G. M. (2005) · Analytical Chemistry · doi:10.1021/ac048303p · Cited by 197
Irimia, D., Liu, S.-Y., Tharp, W. G., Samadani, A., Toner, M., & Poznansky, M. C. (2006) · Lab Chip · doi:10.1039/b511877h · Cited by 196
Flow rate analysis of a surface tension driven passive micropump
Berthier, E., & Beebe, D. J. (2007) · Lab on a Chip · doi:10.1039/b707637a · Cited by 191
Automated cell culture in high density tubeless microfluidic device arrays
Meyvantsson, I., Warrick, J. W., Hayes, S., Skoien, A., & Beebe, D. J. (2008) · Lab on a Chip · doi:10.1039/b715375a · Cited by 172
Analysis and experiment of capillary valves for microfluidics on a rotating disk
Chen, J. M., Huang, P.-C., & Lin, M.-G. (2008) · Microfluidics and Nanofluidics · doi:10.1007/s10404-007-0196-x · Cited by 158
Wang, Y., Choi, M. H., & Han, J. (2004) · Analytical Chemistry · doi:10.1021/ac0497499 · Cited by 148
A PDMS-based gas permeation pump for on-chip fluid handling in microfluidic devices
Eddings, M. A., & Gale, B. K. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/11/021 · Cited by 147
Microfluidic sorting with high-speed single-layer membrane valves
Abate, A. R., Agresti, J. J., & Weitz, D. A. (2010) · Applied Physics Letters · doi:10.1063/1.3431281 · Cited by 135
Cooksey, G. A., Sip, C. G., & Folch, A. (2008) · Lab on a Chip · doi:10.1039/b806803h · Cited by 131
Self-citationPneumatically driven peristaltic micropumps utilizing serpentine-shape channels
Wang, C.-H., & Lee, G. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/2/019 · Cited by 122
The ‘acoustic scallop’: a bubble-powered actuator
Dijkink, R., van der Dennen, J. P., Ohl, C., & Prosperetti, A. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/8/029 · Cited by 108
The dynamic micropump driven with a screen printed PZT actuator
Koch, M., Evans, A. G. R., & Brunnschweiler, A. (1998) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/8/2/019 · Cited by 105
Handheld recirculation system and customized media for microfluidic cell culture
Futai, N., Gu, W., Song, J. W., & Takayama, S. (2005) · Lab on a Chip · doi:10.1039/b510901a · Cited by 97
Li, L., Du, W., & Ismagilov, R. F. (2009) · Journal of the American Chemical Society · doi:10.1021/ja908558m · Cited by 95
Cell handling using microstructured membranes
Irimia, D., & Toner, M. (2006) · Lab on a Chip · doi:10.1039/b515983k · Cited by 88
Microfluidic valve with cored glass microneedle for microinjection
Lee, S., Jeong, W., & Beebe, D. J. (2003) · Lab on a Chip · doi:10.1039/b305692a · Cited by 64
Design and dynamic characterization of “single-stroke” peristaltic PDMS micropumps
Lai, H., & Folch, A. (2010) · Lab on a Chip · doi:10.1039/c0lc00023j · Cited by 57
Self-citationPumping fluids in microfluidic systems using the elastic deformation of poly(dimethylsiloxane)
Weibel, D. B., Siegel, A. C., Lee, A., George, A. H., & Whitesides, G. M. (2007) · Lab on a Chip · doi:10.1039/b714664g · Cited by 56
Mosadegh, B., Tavana, H., Lesher‐Pérez, S. C., & Takayama, S. (2010) · Lab on a Chip · doi:10.1039/c0lc00112k · Cited by 54
Huang, S.-B., Wu, M., Cui, Z., Cui, Z., & Lee, G. (2008) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/18/4/045008 · Cited by 50
Fabrication of a peristaltic micro pump with novel cascaded actuators
Jeong, O. C., & Konishi, S. (2008) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/18/2/025022 · Cited by 44
A microfluidic mammalian cell sorter based on fluorescence detection
Studer, V. (2004) · Microelectronic Engineering · doi:10.1016/s0167-9317(04)00233-3 · Cited by 40
Kim, J., Park, H., Kwon, K., Park, J. Y., Baek, J. Y., Lee, T. S., Song, H. R., Park, Y. D., & Lee, S. H. (2007) · Biomedical Microdevices · doi:10.1007/s10544-007-9105-z · Cited by 23
AN OPEN-SURFACE MICRO-DISPENSER VALVE FOR THE LOCAL STIMULATION OF CONVENTIONAL TISSUE CULTURES
Sip, C. G., & Folch, A. (2010) · International Conference on Miniaturized Systems for Chemistry and Life Sciences (MicroTAS) · Cited by 2
Self-citation
Cited by
The upcoming 3D-printing revolution in microfluidics
Bhattacharjee, N., Urrios, A., Kang, S., & Folch, A. (2016) · Lab on a Chip · doi:10.1039/c6lc00163g · Cited by 1,123
Self-citationCritical review on biofilm methods
Azeredo, J., Azevedo, N. F., Briandet, R., Cerca, N., Coenye, T., Costa, A. R., Desvaux, M., Di Bonaventura, G., Hébraud, M., Jaglic, Z., et al. (2017) · Critical Reviews in Microbiology · doi:10.1080/1040841x.2016.1208146 · Cited by 1,045
Advances in Microfluidic Materials, Functions, Integration, and Applications
Nge, P. N., Rogers, C. I., & Woolley, A. T. (2013) · Chemical Reviews · doi:10.1021/cr300337x · Cited by 958
Convery, N., & Gadegaard, N. (2019) · Micro and Nano Engineering · doi:10.1016/j.mne.2019.01.003 · Cited by 602
Costa, C. M., Cardoso, V. F., Martins, P., Correia, D. M., Gonçalves, R., Costa, P., Correia, V., Ribeiro, C., Fernandes, M. M., Martins, P. M., et al. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00196 · Cited by 498
Metadata
- Authors
- Au, A. K., Lai, H., Utela, B. R., & Folch, A.
- Venue
- Micromachines
- Publisher
- MDPI AG
- Published
- 2011-05-24
- Volume
- 2
- Issue
- 2
- Pages
- 179-220
- ISSN
- 2072-666X (ISSN-L)
- OpenAlex
- W1982759742
- Cited by
- 332
- References
- 51
- FWCI
- 5.83
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.