Comparing Conventional and Advanced Approaches for Heavy Metal Removal in Wastewater Treatment: An In-Depth Review Emphasizing Filter-Based Strategies
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Various industrial activities release heavy metal ions into the environment, which represent one of the major toxic pollutants owing to their severe effects on the environment, humans, and all living species. Despite several technological advances and breakthroughs, wastewater treatment remains a critical global issue. Traditional techniques are dedicated to extracting heavy metal ions from diverse wastewater origins, encompassing coagulation/flocculation, precipitation, flotation, and ion exchange. Their cost, side toxicity, or ineffectiveness often limit their large-scale use. Due to their adaptable design, simple operation, and reasonable cost, membrane filtration and adsorption have proven their efficiency in removing metals from wastewater. Recently, adsorption-based filters have appeared promising in treating water. Within this range, filters incorporating natural, synthetic, or hybrid adsorbents present an appealing alternative to conventional approaches. This review aims to list and describe the conventional and advanced wastewater treatment methods by comparing their efficiency, cost, and environmental impact. Adsorption-based filters were highlighted due to the significant advantages they can provide.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Removal of heavy metal ions from wastewaters: A review
Fu, F., & Wang, Q. (2011) · Journal of Environmental Management · doi:10.1016/j.jenvman.2010.11.011 · Cited by 8,703 · cited 1×
“Furthermore, hybrid inorganic/natural adsorbents primarily based on alumina and 4-amino antipyrine have been implemented to remove Pb, Cu, and Cr from industrial wastewater.”
BackgroundInsights into the modeling of adsorption isotherm systems
Foo, K. Y., & Hameed, B. H. (2010) · Chemical Engineering Journal · doi:10.1016/j.cej.2009.09.013 · Cited by 8,479 · cited 1×
“In less-developed countries, natural coagulants are commonly employed as point-of-use technology due to their ability to be locally produced and easily processed into a usable form.”
BackgroundArsenic removal from water/wastewater using adsorbents—A critical review
Mohan, D., & Pittman, C. U. (2007) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2007.01.006 · Cited by 3,536
New trends in removing heavy metals from industrial wastewater
Barakat, M. A. (2011) · Arabian Journal of Chemistry · doi:10.1016/j.arabjc.2010.07.019 · Cited by 3,094 · cited 4×
“Other relatively advanced techniques, such as adsorption and membrane filtration, have become excellent alternative treatments with improved removal effectiveness and reduced costs and environmental impact [15].”
BackgroundInfluentialAdvantages and disadvantages of techniques used for wastewater treatment
Crini, G., & Lichtfouse, E. (2019) · Environmental Chemistry Letters · doi:10.1007/s10311-018-0785-9 · Cited by 2,971
Removal of heavy metal ions from wastewater: a comprehensive and critical review
Qasem, N. A. A., Mohammed, R. H., & Lawal, D. U. (2021) · npj Clean Water · doi:10.1038/s41545-021-00127-0 · Cited by 2,225 · cited 2×
“Ion Exchange Despite its relatively high e ffi ciency, about 95–99%, for most heavy metals present in wastewater, the precipitation method su ff ers various drawbacks [47]. previously described methods [49].”
BackgroundPhysico–chemical treatment techniques for wastewater laden with heavy metals
Kurniawan, T. A., Chan, G. Y. S., Lo, W.-H., & Babel, S. (2006) · Chemical Engineering Journal · doi:10.1016/j.cej.2006.01.015 · Cited by 2,072
Da̧browski, A., Hubicki, Z., Podkościelny, P., & Robens, E. (2004) · Chemosphere · doi:10.1016/j.chemosphere.2004.03.006 · Cited by 1,717 · cited 2×
“The reversible chemical response used to transform unwanted metallic ions into less environmentally harmful ones makes the ion exchange treatment an alternative to the previously described methods [49]. cation; WC + , the wastewater cation; and M , the stable ion.”
BackgroundBurakov, A. E., Galunin, E. V., Burakova, I. V., Kucherova, A. E., Agarwal, S., Tkachev, A. G., & Gupta, V. K. (2018) · Ecotoxicology and Environmental Safety · doi:10.1016/j.ecoenv.2017.11.034 · Cited by 1,612
Microbial and plant derived biomass for removal of heavy metals from wastewater
Ahluwalia, S. S., & Goyal, D. (2007) · Bioresource Technology · doi:10.1016/j.biortech.2005.12.006 · Cited by 1,586 · cited 1×
“High recovery and regeneration capabilities are highly desirable for commercial and industrial applications, as they can significantly reduce the overall cost associated with adsorbent production [144].”
BackgroundYang, X., Wan, Y., Zheng, Y., He, F., Yu, Z., Huang, J., Wang, H., Ok, Y. S., Jiang, Y., & Gao, B. (2019) · Chemical Engineering Journal · doi:10.1016/j.cej.2019.02.119 · Cited by 1,527 · cited 1×
“] Cd 2+ 99 Furthermore, the design and configuration of the filters, encompassing parameters like porosity, depth, flow rate, and material leakage into the water effluents, require careful consideration and improvement [95].”
BackgroundRecent Advancement of Coagulation–Flocculation and Its Application in Wastewater Treatment
Teh, C. Y., Budiman, P. M., Shak, K. P. Y., & Wu, T. Y. (2016) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.5b04703 · Cited by 1,160 · cited 1×
“This approach can efficiently eliminate a range of heavy metals, including Cu, Pb, Ni, As, Se, Cr, Sb, and Ag [45].”
BackgroundMetal–organic frameworks for heavy metal removal from water
Kobielska, P. A., Howarth, A. J., Farha, O. K., & Nayak, S. (2018) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2017.12.010 · Cited by 1,014
Soil-plant transfer of trace elements - an environmental issue
Kabata-Pendias, A. (2004) · Geoderma · doi:10.1016/j.geoderma.2004.01.004 · Cited by 903
Recent trends of heavy metal removal from water/wastewater by membrane technologies
Abdullah, N., Yusof, N., Lau, W. J., Jaafar, J., & Ismail, A. F. (2019) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2019.03.029 · Cited by 769 · cited 1×
“The physical process assumes greater signi fi cance when it comes to the removal of heavy metals from wastewater.”
BackgroundAdsorption of heavy metal ions by various low-cost adsorbents: a review
Chakraborty, R., Asthana, A., Singh, A. K., Jain, B., & Susan, A. B. H. (2022) · International Journal of Environmental & Analytical Chemistry · doi:10.1080/03067319.2020.1722811 · Cited by 659
Adsorption of heavy metals on natural zeolites: A review
Velarde, L., Nabavi, M. S., Escalera, E., Antti, M.-L., & Akhtar, F. (2023) · Chemosphere · doi:10.1016/j.chemosphere.2023.138508 · Cited by 491 · cited 1×
“Beans (black-eyed peas) and peanuts do not have high metal removal efficiency ( 15% for Cu and Cd).”
BackgroundRegeneration of adsorbents and recovery of heavy metals: a review
Lata, S., Singh, P. K., & Samadder, S. R. (2015) · International Journal of Environmental Science and Technology · doi:10.1007/s13762-014-0714-9 · Cited by 491
Membrane and Desalination Technologies
(2011) · doi:10.1007/978-1-59745-278-6 · Cited by 372
Ozaki, H., Sharma, K., & Saktaywin, W. (2002) · Desalination · doi:10.1016/s0011-9164(02)00329-6 · Cited by 362
Fang, Q.-R., Yuan, D.-Q., Sculley, J., Li, J.-R., Han, Z.-B., & Zhou, H.-C. (2010) · Inorganic Chemistry · doi:10.1021/ic101935f · Cited by 309 · cited 1×
“Some reported MOFs were used for Cd 2+ , Pb 2+ , and Hg 2+ removal with a capacity of 97%, 95%, and 93%, respectively [54], ZIF-8 eliminated 95% of Cu [55], and Both examined resins demonstrated an e ffi ciency of approximately 90% in the removal of trivalent chromium from aqueous solutions [52].”
MethodEnrichment of the surface functional groups of activated carbon by modification method
Demiral, İ., Samdan, C., & Demiral, H. (2021) · Surfaces and Interfaces · doi:10.1016/j.surfin.2020.100873 · Cited by 254 · cited 1×
“Cu”
Novel forward osmosis process to effectively remove heavy metal ions
Cui, Y., Ge, Q., Liu, X.-Y., & Chung, T.-S. (2014) · Journal of Membrane Science · doi:10.1016/j.memsci.2014.05.034 · Cited by 224
Zhang, Y., Xie, Z., Wang, Z., Feng, X., Wang, Y., & Wu, A. (2016) · Dalton Transactions · doi:10.1039/c6dt01827k · Cited by 215
He, M., Wang, L., Lv, Y., Wang, X., Zhu, J., Zhang, Y., & Liu, T. (2020) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.124452 · Cited by 206
Heavy metal contamination in the seaweeds of the Venice lagoon
Caliceti, M., Argese, E., Sfriso, A., & Pavoni, B. (2002) · Chemosphere · doi:10.1016/s0045-6535(01)00292-2 · Cited by 191
Valorisation of post-sorption materials: Opportunities, strategies, and challenges
Harikishore Kumar Reddy, D., Vijayaraghavan, K., Kim, J. A., & Yun, Y.-S. (2017) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2016.12.002 · Cited by 127 · cited 1×
“The integration of multiple treatment methods and the development of hybrid systems can enhance the overall effectiveness of heavy metal removal.”
BackgroundCapacity of ‘nopal’ pectin as a dual coagulant-flocculant agent for heavy metals removal
Ibarra-Rodríguez, D., Lizardi-Mendoza, J., López-Maldonado, E. A., & Oropeza-Guzmán, M. T. (2017) · Chemical Engineering Journal · doi:10.1016/j.cej.2017.04.087 · Cited by 102 · cited 1×
“Coagulation refers to destabilizing colloids by neutralizing their repulsive forces, while flocculation involves aggregating unstable particles [41].”
BackgroundJin, W., Fu, Y., Hu, M., Wang, S., & Liu, Z. (2020) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2019.113744 · Cited by 93
Min, K. J., Kim, J. H., & Park, K. Y. (2021) · Science of The Total Environment · doi:10.1016/j.scitotenv.2020.143762 · Cited by 72
Cited by
Understanding PFAS Adsorption: How Molecular Structure Affects Sustainable Water Treatment
Hamza, M., Ayinla, R. T., Elsayed, I., & Hassan, E. B. (2025) · Environments · doi:10.3390/environments12090330 · Cited by 43
“Non-destructive techniques for PFAS removal include traditional coagulation, flocculation, adsorption, ion exchange resins (IX), and membrane filtration [57,60,61].”
An Integrated Approach to Pb Bioremediation: Role of Bacteria in Enhancing Phytoremediation
Bender, L. A., Demarco, C. F., Pieniz, S., Carlos, F. S., Quadro, M. S., & Andreazza, R. (2025) · Sustainability · doi:10.3390/su17041386 · Cited by 21
El Gamal, G. A., & Gomaa, A. M. (2025) · Scientific Reports · doi:10.1038/s41598-025-24902-y · Cited by 11
Golmohammadi, G., Joolaei Ahranjani, P., Sereshti, H., Dehghan, K., Sadatfaraji, H., Karami, S., & Rashidi Nodeh, H. (2025) · Separation Science and Technology · doi:10.1080/01496395.2025.2502753 · Cited by 1
“[6] Spectroscopic and chromatographic meth-ods, such as atomic absorption spectroscopy (AAS), inductively coupled plasma mass spectrometry (ICP-MS), and high-performance liquid chromatography (HPLC), are commonly employed for cadmium detection.”
Metadata
- Authors
- Ayach, J., El Malti, W., Duma, L., Lalevée, J., Al Ajami, M., Hamad, H., & Hijazi, A.
- Venue
- Polymers
- Publisher
- MDPI AG
- Published
- 2024-07-09
- Volume
- 16
- Issue
- 14
- Pages
- 1959
- ISSN
- 2073-4360 (ISSN-L)
- OpenAlex
- W4400455877
- Cited by
- 221
- References
- 30
- FWCI
- 24.69
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.