The DOI matches its Crossref record; 80 of the 80 references it cites were found in a registry or an index.
Gait Partitioning Methods: A Systematic Review
Open accessAbstract
In the last years, gait phase partitioning has come to be a challenging research topic due to its impact on several applications related to gait technologies. A variety of sensors can be used to feed algorithms for gait phase partitioning, mainly classifiable as wearable or non-wearable. Among wearable sensors, footswitches or foot pressure insoles are generally considered as the gold standard; however, to overcome some inherent limitations of the former, inertial measurement units have become popular in recent decades. Valuable results have been achieved also though electromyography, electroneurography, and ultrasonic sensors. Non-wearable sensors, such as opto-electronic systems along with force platforms, remain the most accurate system to perform gait analysis in an indoor environment. In the present paper we identify, select, and categorize the available methodologies for gait phase detection, analyzing advantages and disadvantages of each solution. Finally, we comparatively examine the obtainable gait phase granularities, the usable computational methodologies and the optimal sensor placements on the targeted body segments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A tutorial on hidden Markov models and selected applications in speech recognition
Rabiner, L. R. (1989) · Proceedings of the IEEE · doi:10.1109/5.18626 · Cited by 22,743
Fuzzy identification of systems and its applications to modeling and control
Takagi, T., & Sugeno, M. (1985) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1985.6313399 · Cited by 19,592
THE MAJOR DETERMINANTS IN NORMAL AND PATHOLOGICAL GAIT
Saunders, J. B. D. M., Inman, V. T., & Eberhart, H. D. (1953) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-195335030-00003 · Cited by 1,299
Zeni, J. A., Richards, J. G., & Higginson, J. S. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.07.007 · Cited by 1,261
Fuzzy Logic: Intelligence, Control, and Information
Yen, J., & Langari, R. (1998) · Medical Entomology and Zoology · Cited by 1,184
Muro-de-la-Herran, A., Garcia-Zapirain, B., & Mendez-Zorrilla, A. (2014) · Sensors · doi:10.3390/s140203362 · Cited by 1,172
Nutrition labels on pre-packaged foods: a systematic review
Campos, S., Doxey, J., & Hammond, D. (2011) · Public Health Nutrition · doi:10.1017/s1368980010003290 · Cited by 937
Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes
Aminian, K., Najafi, B., Büla, C., Leyvraz, P.-F., & Robert, P. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00008-8 · Cited by 814
Machine Learning Methods for Classifying Human Physical Activity from On-Body Accelerometers
Mannini, A., & Sabatini, A. M. (2010) · Sensors · doi:10.3390/s100201154 · Cited by 781
Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait
Blaya, J. A., & Herr, H. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.823266 · Cited by 741
Gait Analysis Using a Shoe-Integrated Wireless Sensor System
Bamberg, S., Benbasat, A. Y., Scarborough, D. M., Krebs, D. E., & Paradiso, J. A. (2008) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2007.899493 · Cited by 737
Gait analysis for recognition and classification
Lee, L., & Grimson, W. E. L. (2003) · Proceedings of Fifth IEEE International Conference on Automatic Face Gesture Recognition · doi:10.1109/afgr.2002.1004148 · Cited by 734
Mayagoitia, R. E., Nene, A. V., & Veltink, P. H. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00231-7 · Cited by 655
Accelerometry: A technique for quantifying movement patterns during walking
Kavanagh, J. J., & Menz, H. B. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.10.010 · Cited by 617
Automatic detection of gait events using kinematic data
O’Connor, C. M., Thorpe, S. K., O’Malley, M. J., & Vaughan, C. L. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2006.05.016 · Cited by 557
A practical gait analysis system using gyroscopes
Tong, K., & Granat, M. H. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00030-2 · Cited by 460
Jasiewicz, J. M., Allum, J. H. J., Middleton, J. W., Barriskill, A., Condie, P., Purcell, B., & Li, R. C. T. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2005.12.017 · Cited by 371
Speed dependence of averaged EMG profiles in walking
Hof, A. L., Elzinga, H., Grimmius, W., & Halbertsma, J. P. K. (2002) · Gait & Posture · doi:10.1016/s0966-6362(01)00206-5 · Cited by 313
A Gait Monitoring System Based on Air Pressure Sensors Embedded in a Shoe
Kong, K., & Tomizuka, M. (2009) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2008.2008803 · Cited by 301
Development of a wearable sensor system for quantitative gait analysis
Liu, T., Inoue, Y., & Shibata, K. (2009) · Measurement · doi:10.1016/j.measurement.2009.02.002 · Cited by 262
Quantitative estimation of foot-flat and stance phase of gait using foot-worn inertial sensors
Mariani, B., Rouhani, H., Crevoisier, X., & Aminian, K. (2013) · Gait & Posture · doi:10.1016/j.gaitpost.2012.07.012 · Cited by 258
Ghoussayni, S., Stevens, C., Durham, S., & Ewins, D. (2004) · Gait & Posture · doi:10.1016/j.gaitpost.2003.10.001 · Cited by 244
A Reliable Gyroscope-Based Gait-Phase Detection Sensor Embedded in a Shoe Insole
Pappas, I. P. I., Keller, T., Mangold, S., Popovic, M., Dietz, V., & Morari, M. (2004) · IEEE Sensors Journal · doi:10.1109/jsen.2004.823671 · Cited by 221
Real-time gait event detection for normal subjects from lower trunk accelerations
González, R. C., López, A. M., Rodriguez-Uría, J., Álvarez, D., & Alvarez, J. C. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2009.11.014 · Cited by 205
3D Gait Recognition Using Multiple Cameras
Zhao, G., Liu, G., Li, H., & Pietikainen, M. (2006) · 7th International Conference on Automatic Face and Gesture Recognition (FGR06) · doi:10.1109/fgr.2006.2 · Cited by 197
Real-time gait event detection using wearable sensors
Hanlon, M., & Anderson, R. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2009.07.128 · Cited by 187
Online gait event detection using a large force platform embedded in a treadmill
Roerdink, M., Coolen, B. (. )., Clairbois, B. (. )., Lamoth, C. J. C., & Beek, P. J. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.06.023 · Cited by 179
Lau, H., & Tong, K. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.03.018 · Cited by 165
Real-time gait event detection for paraplegic FES walking
Skelly, M., & Chizeck, H. J. (2001) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/7333.918277 · Cited by 165
Gait event detection for FES using accelerometers and supervised machine learning
Williamson, R., & Andrews, B. J. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.867873 · Cited by 164
Mannini, A., & Sabatini, A. M. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.06.017 · Cited by 160
The use of accelerometry to detect heel contact events for use as a sensor in FES assisted walking
Mansfield, A., & Lyons, G. M. (2003) · Medical Engineering & Physics · doi:10.1016/s1350-4533(03)00116-4 · Cited by 160
Gait Event Detection on Level Ground and Incline Walking Using a Rate Gyroscope
Catalfamo, P., Ghoussayni, S., & Ewins, D. (2010) · Sensors · doi:10.3390/s100605683 · Cited by 159
Gait Recognition Using Image Self-Similarity
BenAbdelkader, C., Cutler, R., & Davis, L. S. (2004) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/s1110865704309236 · Cited by 155
Kotiadis, D., Hermens, H. J., & Veltink, P. H. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2009.10.014 · Cited by 151
Selles, R. W., Formanoy, M. A. G., Bussmann, J. B. J., Janssens, P. J., & Stam, H. J. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.843176 · Cited by 151
Automatic Detection of Temporal Gait Parameters in Poststroke Individuals
Lopez‐Meyer, P., Fulk, G. D., & Sazonov, E. E. (2011) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2011.2112773 · Cited by 148
Gender Classification in Human Gait Using Support Vector Machine
Yoo, J., Hwang, D., & Nixon, M. S. (2005) · Lecture notes in computer science · doi:10.1007/11558484_18 · Cited by 143
Taborri, J., Rossi, S., Palermo, E., Patanè, F., & Cappa, P. (2014) · Sensors · doi:10.3390/s140916212 · Cited by 139
Self-citationOnline Decoding of Hidden Markov Models for Gait Event Detection Using Foot-Mounted Gyroscopes
Mannini, A., Genovese, V., & Sabatini, A. M. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2293887 · Cited by 132
Online Phase Detection Using Wearable Sensors for Walking with a Robotic Prosthesis
Goršič, M., Kamnik, R., Ambrožič, L., Vitiello, N., Lefeber, D., Pasquini, G., & Munih, M. (2014) · Sensors · doi:10.3390/s140202776 · Cited by 125
Accurate and Reliable Gait Cycle Detection in Parkinson's Disease
Hundza, S. R., Hook, W. R., Harris, C. R., Mahajan, S. V., Leslie, P., Spani, C., Spalteholz, L. G., Birch, B., Commandeur, D. T., & Livingston, N. J. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2282080 · Cited by 121
Accelerometry Based Classification of Walking Patterns Using Time-frequency Analysis
Wang, N., Eliathamby Ambikairajah, A., Lovell, N. H., & Celler, B. G. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353438 · Cited by 117
Automated detection of gait initiation and termination using wearable sensors
Novak, D., Reberšek, P., Rossi, S., Donati, M., Podobnik, J., Beravs, T., Lenzi, T., Vitiello, N., Carrozza, M. C., & Munih, M. (2013) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2013.07.003 · Cited by 116
Self-citationGouwanda, D., & Gopalai, A. A. (2015) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.12.004 · Cited by 109
Smith, B. T., Coiro, D. J., Finson, R. L., Betz, R. R., & McCarthy, J. J. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.1021583 · Cited by 108
Gait phase analysis based on a Hidden Markov Model
Bae, J., & Tomizuka, M. (2011) · Mechatronics · doi:10.1016/j.mechatronics.2011.03.003 · Cited by 106
Classification of gait phases from lower limb EMG: Application to exoskeleton orthosis
Joshi, C., Lahiri, U., & Thakor, N. V. (2013) · 2013 IEEE Point-of-Care Healthcare Technologies (PHT) · doi:10.1109/pht.2013.6461326 · Cited by 105
An Ambulatory System for Gait Monitoring Based on Wireless Sensorized Insoles
Gónzalez, I., Fontecha, J., Hervás, R., & Bravo, J. (2015) · Sensors · doi:10.3390/s150716589 · Cited by 103
Smooth and continuous human gait phase detection based on foot pressure patterns
Kong, K., & Tomizuka, M. (2008) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2008.4543775 · Cited by 95
Development and validation of an accelerometer-based method for quantifying gait events
Boutaayamou, M., Schwartz, C., Stamatakis, J., Denoël, V., Maquet, D., Forthomme, B., Croisier, J., Macq, B. M. M., Verly, J., Garraux, G., et al. (2015) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2015.01.001 · Cited by 94
Normal Human Locomotion, Part 1
Ayyappa, E. (1997) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-199700910-00004 · Cited by 93
Gait Detection in Children with and without Hemiplegia Using Single-Axis Wearable Gyroscopes
Abaid, N., Cappa, P., Palermo, E., Petrarca, M., & Porfiri, M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0073152 · Cited by 92
Self-citationA hidden Markov model-based technique for gait segmentation using a foot-mounted gyroscope
Mannini, A., & Sabatini, A. M. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091084 · Cited by 91
Lauer, R. T., Smith, B. T., & Betz, R. R. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851527 · Cited by 85
Aung, M. H., Thies, S. B., Kenney, L. P. J., Howard, D., Selles, R. W., Findlow, A. H., & Goulermas, J. Y. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2239313 · Cited by 84
Computational Intelligent Gait-Phase Detection System to Identify Pathological Gait
Senanayake, C., & Senanayake, S. M. N. A. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2058813 · Cited by 83
Gait event detection for use in FES rehabilitation by radial and tangential foot accelerations
Rüterbories, J., Spaich, E. G., & Andersen, O. K. (2013) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2013.10.004 · Cited by 81
Taborri, J., Scalona, E., Palermo, E., Rossi, S., & Cappa, P. (2015) · Sensors · doi:10.3390/s150924514 · Cited by 77
Self-citationQi, Y., Soh, C. B., Gunawan, E., Low, K., & Thomas, R. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2409123 · Cited by 69
Gait Event Detection during Stair Walking Using a Rate Gyroscope
Formento, P. C., Acevedo, R., Ghoussayni, S., & Ewins, D. (2014) · Sensors · doi:10.3390/s140305470 · Cited by 68
Application of wearable sensors for human gait analysis using fuzzy computational algorithm
Alaqtash, M., Yu, H., Brower, R. D., Abdelgawad, A. H. K., & Sarkodie-Gyan, T. (2011) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2011.04.010 · Cited by 65
Sant’Anna, A., & Wickström, N. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2047402 · Cited by 63
Normal Human Locomotion, Part 1: Basic Concepts and Terminology
Ayyappa, E. (1997) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-199701000-00004 · Cited by 56
Development of gait segmentation methods for wearable foot pressure sensors
Crea, S., Rossi, S., Donati, M., Reberšek, P., Novak, D., Vitiello, N., Lenzi, T., Podobnik, J., Munih, M., & Carrozza, M. C. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6347120 · Cited by 55
Self-citationAutomatic identification of gait events using an instrumented sock
Preece, S. J., Kenney, L. P. J., Major, M. J., Dias, T., Lay, E., & Fernandes, B. T. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-32 · Cited by 47
Gait Event Detection with Intelligent Shoes
Huang, B., Chen, M., Shi, X., & Xu, Y. (2007) · IEEE International Conference on Information Acquisition · doi:10.1109/icia.2007.4295799 · Cited by 44
Detection of Gait Phases Using Orient Specks for Mobile Clinical Gait Analysis
Evans, R. L., & Arvind, D. K. (2014) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2014.22 · Cited by 41
Strange, K. D., & Hoffer, J. A. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.771189 · Cited by 39
Real-world Gyroscope-based Gait Event Detection and Gait Feature Extraction
Fraccaro, P., Walsh, L. C., Doyle, J., & O’Sullivan, D. M. (2014) · NORMA · Cited by 35
Real-time gait detection based on Hidden Markov Model: Is it possible to avoid training procedure?
Taborri, J., Scalona, E., Rossi, S., Palermo, E., Patanè, F., & Cappa, P. (2015) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2015.7145188 · Cited by 31
Self-citationRafajlović, S., Gavrilović, M., & Mijailović, N. (2009) · DOAJ (DOAJ: Directory of Open Access Journals) · Cited by 29
Gait event detection through neuromorphic spike sequence learning
Lee, W. W., Yu, H., & Thakor, N. V. (2014) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2014.6913895 · Cited by 26
Chu, J., Song, K., Han, S., Lee, S. H., Kang, J. Y., Hwang, D., Suh, J. F., Choi, K., & Youn, I. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/5/541 · Cited by 23
Automatic recognition of gait phases from accelerations of leg segments
Djuric, M. (2008) · Symposium on Neural Network Applications in Electrical Engineering · doi:10.1109/neurel.2008.4685586 · Cited by 23
Gait based Gender Identification using Statistical Pattern Classifiers
Sudha, L., & Bhavani, R. (2012) · International Journal of Computer Applications · doi:10.5120/4985-7248 · Cited by 21
Design of a smart shoe for reliable gait analysis using state transition theory
Srivises, W., Nilkhamhang, I., & Tungpimolrut, K. (2012) · International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON) · doi:10.1109/ecticon.2012.6254200 · Cited by 20
A HMM distributed classifier to control robotic knee module of an active orthosis
Taborri, J., Rossi, S., Palermo, E., & Cappa, P. (2015) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2015.7281212 · Cited by 11
Self-citationGait phase detection optimization based on variational bayesian inference of feedback sensor signal
Malešević, N., Malesevic, J. M., & Keller, T. (2014) · Symposium on Neural Network Applications in Electrical Engineering · doi:10.1109/neurel.2014.7011499 · Cited by 6
Development of a Portable Gait Phase Detection System for Patients with Gait Disorders
Chan, A. S., Jae, H. S., Kang, S., & Ho, K. Y. (2005) · Journal of Biomedical Engineering Research · Cited by 2
Cited by
Liu, Y., Wang, H., Zhao, W., Zhang, M., Qin, H., & Xie, Y. (2018) · Sensors · doi:10.3390/s18020645 · Cited by 387
Wearable sensor-based real-time gait detection: A systematic review
Prasanth, H., Caban, M., Keller, U., Courtine, G., Ijspeert, A., Vallery, H., & von Zitzewitz, J. (2021) · Sensors · doi:10.3390/s21082727 · Cited by 348
Use of wearable sensor technology in gait, balance, and range of motion analysis
Díaz, S., Stephenson, J. B., & Labrador, M. A. (2019) · Applied Sciences · doi:10.3390/app10010234 · Cited by 132
A review of current state-of-the-art control methods for lower-limb powered prostheses
Gehlhar, R., Tucker, M., Young, A. J., & Ames, A. D. (2023) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2023.03.003 · Cited by 131
Deep Learning Approaches for Enhanced Lower-Limb Exoskeleton Control: A Review
Belal, M., Alsheikh, N., Aljarah, A., & Hussain, I. (2024) · IEEE Access · doi:10.1109/access.2024.3414175 · Cited by 42
Metadata
- Authors
- Taborri, J., Palermo, E., Rossi, S., & Cappa, P.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2016-01-06
- Volume
- 16
- Issue
- 1
- Pages
- 66
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2222399534
- Cited by
- 361
- References
- 80
- FWCI
- 2.89
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.