The DOI matches its Crossref record; 93 of the 93 references it cites were found in a registry or an index.
Removal of Artifacts from EEG Signals: A Review
Open accessAbstract
Electroencephalogram (EEG) plays an important role in identifying brain activity and behavior. However, the recorded electrical activity always be contaminated with artifacts and then affect the analysis of EEG signal. Hence, it is essential to develop methods to effectively detect and extract the clean EEG data during encephalogram recordings. Several methods have been proposed to remove artifacts, but the research on artifact removal continues to be an open problem. This paper tends to review the current artifact removal of various contaminations. We first discuss the characteristics of EEG data and the types of different artifacts. Then, a general overview of the state-of-the-art methods and their detail analysis are presented. Lastly, a comparative analysis is provided for choosing a suitable methods according to particular application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, N. E., Shen, Z., Long, S. R., Wu, M. C., Shih, H. H., Zheng, Q., Yen, N.-C., Tung, C. C., & Liu, H. H. (1998) · Proceedings of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rspa.1998.0193 · Cited by 23,564
Matching pursuits with time-frequency dictionaries
Mallat, S. G., & Zhang, Z. (1993) · IEEE Transactions on Signal Processing · doi:10.1109/78.258082 · Cited by 9,112
ENSEMBLE EMPIRICAL MODE DECOMPOSITION: A NOISE-ASSISTED DATA ANALYSIS METHOD
WU, Z., & HUANG, N. E. (2009) · Advances in Adaptive Data Analysis · doi:10.1142/s1793536909000047 · Cited by 8,715
HomER: A review of time-series analysis methods for near-infrared spectroscopy of the brain
Huppert, T. J., Diamond, S. G., Franceschini, M. A., & Boas, D. A. (2009) · Applied Optics · doi:10.1364/ao.48.00d280 · Cited by 1,817
Identifying true brain interaction from EEG data using the imaginary part of coherency
Nolte, G., Bai, O., Wheaton, L., Mari, Z., Vorbach, S., & Hallett, M. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.04.029 · Cited by 1,756
Jung, T.-P., Makeig, S., Westerfield, M., Townsend, J., Courchesne, E., & Sejnowski, T. J. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00386-2 · Cited by 1,322
EEG artifact removal—state-of-the-art and guidelines
Urigüen, J. A., & Garcia-Zapirain, B. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/031001 · Cited by 963
Chaumon, M., Bishop, D. V. M., & Busch, N. A. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.02.025 · Cited by 833
Independent component approach to the analysis of EEG and MEG recordings
Vigario, R., Sarela, J., Jousmiki, V., Hamalainen, M., & Oja, E. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.841330 · Cited by 796
Removal of ocular artifact from the EEG: a review
Croft, R. J., & Barry, R. J. (2000) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/s0987-7053(00)00055-1 · Cited by 756
EMG contamination of EEG: spectral and topographical characteristics
Goncharova, I. I., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00093-2 · Cited by 696
Extraction of ocular artefacts from EEG using independent component analysis
Vigário, R. N. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00042-8 · Cited by 639
EMG and EOG artifacts in brain computer interface systems: A survey
Fatourechi, M., Bashashati, A., Ward, R. K., & Birch, G. E. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.10.019 · Cited by 638
Automatic removal of eye movement and blink artifacts from EEG data using blind component separation
Joyce, C. A., Gorodnitsky, I. F., & Kutas, M. (2004) · Psychophysiology · doi:10.1111/j.1469-8986.2003.00141.x · Cited by 596
A method to standardize a reference of scalp EEG recordings to a point at infinity
Yao, D. (2001) · Physiological Measurement · doi:10.1088/0967-3334/22/4/305 · Cited by 576
A fully automated correction method of EOG artifacts in EEG recordings
Schlögl, A., Keinrath, C., Zimmermann, D., Scherer, R., Leeb, R., & Pfurtscheller, G. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.09.003 · Cited by 575
Castellanos, N. P., & Makarov, V. A. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.05.033 · Cited by 569
Neuromagnetic source imaging with FOCUSS: a recursive weighted minimum norm algorithm
Gorodnitsky, I. F., George, J. S., & Rao, B. D. (1995) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(95)00107-a · Cited by 567
Canonical Correlation Analysis Applied to Remove Muscle Artifacts From the Electroencephalogram
Clercq, W. D., Vergult, A., Vanrumste, B., Van Paesschen, W., & Van Huffel, S. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.879459 · Cited by 522
Independent component analysis for biomedical signals
James, C. J., & Hesse, C. W. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/1/r02 · Cited by 494
Methods for artifact detection and removal from scalp EEG: A review
Islam, M. K., Rastegarnia, A., & Yang, Z. (2016) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/j.neucli.2016.07.002 · Cited by 457
Kevric, J., & Subasi, A. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.09.007 · Cited by 428
Extended ICA Removes Artifacts from Electroencephalographic Recordings
Jung, T., Humphries, C., Lee, T.-W., Makeig, S., McKeown, M. J., Iragui, V. J., & B, T. J. S. A. (1997) · Cited by 425
Mijović, B., De Vos, M., Gligorijević, I., Taelman, J., & Van Huffel, S. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2051440 · Cited by 382
Removal of ocular artifacts from electro-encephalogram by adaptive filtering
He, P., Wilson, G., & Russell, C. (2004) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344717 · Cited by 364
Artifact Removal in Physiological Signals—Practices and Possibilities
Sweeney, K. T., Ward, T. E., & McLoone, S. F. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2012.2188536 · Cited by 361
EEG-based workers' stress recognition at construction sites
Jebelli, H., Hwang, S., & Lee, S. (2018) · Automation in Construction · doi:10.1016/j.autcon.2018.05.027 · Cited by 339
Robust artifactual independent component classification for BCI practitioners
Winkler, I., Brandl, S., Horn, F., Waldburger, E., Allefeld, C., & Tangermann, M. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/035013 · Cited by 327
Wallstrom, G. L., Kass, R. E., Miller, A., Cohn, J. F., & Fox, N. A. (2004) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2004.03.007 · Cited by 326
Ensemble SVM Method for Automatic Sleep Stage Classification
Alickovic, E., & Subasi, A. (2018) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2799059 · Cited by 313
Source separation using single channel ICA
Davies, M. E., & James, C. J. (2007) · Signal Processing · doi:10.1016/j.sigpro.2007.01.011 · Cited by 301
Sweeney, K. T., McLoone, S. F., & Ward, T. E. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2225427 · Cited by 300
Trends in EEG-BCI for daily-life: Requirements for artifact removal
Minguillon, J., Lopez-Gordo, M. A., & Pelayo, F. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.09.005 · Cited by 289
A generic EEG artifact removal algorithm based on the multi-channel Wiener filter
Somers, B., Francart, T., & Bertrand, A. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaac92 · Cited by 255
Mahajan, R., & Morshed, B. I. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2333010 · Cited by 251
Sparse Components of Images and Optimal Atomic Decompositions
Donoho, D. L. (2001) · Constructive Approximation · doi:10.1007/s003650010032 · Cited by 230
MATLAB Toolboxes for Reference Electrode Standardization Technique (REST) of Scalp EEG
Dong, L., Li, F., Liu, Q., Wen, X., Lai, Y., Xu, P., & Yao, D. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00601 · Cited by 228
Eye movement artifact in the CNV
Hillyard, S. A., & Galambos, R. (1970) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(70)90185-9 · Cited by 211
Qin, Y., Xu, P., & Yao, D. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.03.056 · Cited by 209
Safieddine, D., Kachenoura, A., Albera, L., Birot, G., Karfoul, A., Pasnicu, A., Biraben, A., Wendling, F., Senhadji, L., & Merlet, I. (2012) · EURASIP Journal on Advances in Signal Processing · doi:10.1186/1687-6180-2012-127 · Cited by 198
Automatic removal of the eye blink artifact from EEG using an ICA-based template matching approach
Li, Y., Ma, Z., Lu, W., & Li, Y. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/4/008 · Cited by 197
Electroencephalography: Basic Principles, Clinical Applications, and Related Fields, Fifth Edition
Henry, J. C. (2006) · Neurology · doi:10.1212/01.wnl.0000243257.85592.9a · Cited by 190
Klados, M. A., Papadelis, C., Braun, C., & Bamidis, P. D. (2011) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2011.02.001 · Cited by 176
FORCe: Fully online and automated artifact removal for brain-computer interfacing
Daly, I., Scherer, R., Billinger, M., & Muller-Putz, G. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2346621 · Cited by 174
Motion Artifact Cancellation in NIR Spectroscopy Using Wiener Filtering
Izzetoglu, M., Devaraj, A., Bunce, S., & Onaral, B. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.845243 · Cited by 173
Critical Comments on EEG Sensor Space Dynamical Connectivity Analysis
de Steen, F. V., Faes, L., Karahan, E., Songsiri, J., Valdes-Sosa, P. A., & Marinazzo, D. (2016) · Brain Topography · doi:10.1007/s10548-016-0538-7 · Cited by 171
Berg, P., & Scherg, M. (1991) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/12/a/010 · Cited by 169
Artifact Processing in Computerized Analysis of Sleep EEG – A Review
Anderer, P., Roberts, S., Schlögl, A., Gruber, G., Klösch, G., Herrmann, W., Rappelsberger, P., Filz, O., Barbanoj, M. J., Dorffner, G., et al. (1999) · Neuropsychobiology · doi:10.1159/000026613 · Cited by 161
Artifact removal from electroencephalograms using a hybrid BSS-SVM algorithm
Shoker, L., Sanei, S., & Chambers, J. (2005) · IEEE Signal Processing Letters · doi:10.1109/lsp.2005.855539 · Cited by 160
Automated EEG artifact elimination by applying machine learning algorithms to ICA-based features
Radüntz, T., Scouten, J., Hochmuth, O., & Meffert, B. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa69d1 · Cited by 155
Arnaud Delorme, A., Makeig, S., B, T. J. S. A., & Pines, N. T. (2001) · Cited by 154
EEG source imaging in epilepsy—practicalities and pitfalls
Kaiboriboon, K., Lüders, H. O., Hamaneh, M. B., Turnbull, J. P., & Lhatoo, S. D. (2012) · Nature Reviews Neurology · doi:10.1038/nrneurol.2012.150 · Cited by 142
Removal of Muscle Artifacts from EEG Recordings of Spoken Language Production
Vos, M. D., Riès, S., Vanderperren, K., Vanrumste, B., Alario, F. ‐., Huffel, V. S., & Burle, B. (2010) · Neuroinformatics · doi:10.1007/s12021-010-9071-0 · Cited by 142
Removing Muscle Artifacts From EEG Data: Multichannel or Single-Channel Techniques?
Chen, X., Liu, A., Chiang, J., Wang, Z. J., McKeown, M. J., & Ward, R. K. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2506982 · Cited by 137
Electromyogenic artifacts and electroencephalographic inferences revisited
McMenamin, B. W., Shackman, A. J., Greischar, L. L., & Davidson, R. J. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.07.057 · Cited by 135
Surrogate-Based Artifact Removal From Single-Channel EEG
Chávez, M., Grosselin, F., Bussalb, A., Fallani, F. D. V., & Navarro‐Sune, X. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2794184 · Cited by 124
Adaptive filtering for ECG rejection from surface EMG recordings
Marque, C. K., Bisch, C., Dantas, R., Elayoubi, S., Brosse, V., & Pérot, C. (2004) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2004.10.001 · Cited by 123
Halder, S., Bensch, M., Mellinger, J., Bogdan, M., Kübler, A., Birbaumer, N., & Rosenstiel, W. (2007) · Computational Intelligence and Neuroscience · doi:10.1155/2007/82069 · Cited by 123
Kumar, P. S., Arumuganathan, R., Sivakumar, K., & Vimal, C. (2008) · Cited by 120
Flumeri, G. D., Aricò, P., Borghini, G., Colosimo, A., & Babiloni, F. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591406 · Cited by 115
Zou, Y., Nathan, V., & Jafari, R. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2370646 · Cited by 112
A spectral method for removing eye movement artifacts from the EEG
Whitton, J. L., Lue, F. A., & Moldofsky, H. (1978) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(78)90208-0 · Cited by 110
Fault feature separation using wavelet-ICA filter
Lin, J., & Zhang, A. (2004) · NDT & E International · doi:10.1016/j.ndteint.2004.11.005 · Cited by 105
Using ICA for removal of ocular artifacts in EEG recorded from blind subjects
Flexer, A., Bauer, H., Pripfl, J., & Dorffner, G. (2005) · Neural Networks · doi:10.1016/j.neunet.2005.03.012 · Cited by 105
Hamaneh, M. B., Chitravas, N., Kaiboriboon, K., Lhatoo, S. D., & Loparo, K. A. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2295173 · Cited by 105
Joint Blind Source Separation for Neurophysiological Data Analysis: Multiset and multimodal methods
Chen, X., Wang, Z. J., & McKeown, M. J. (2016) · IEEE Signal Processing Magazine · doi:10.1109/msp.2016.2521870 · Cited by 105
Complexity Measures for Quantifying Changes in Electroencephalogram in Alzheimer’s Disease
Al-Nuaimi, A. H. H., Jammeh, E., Sun, L., & Ifeachor, E. (2018) · Complexity · doi:10.1155/2018/8915079 · Cited by 96
A Brain-Computer Interface Based on a Few-Channel EEG-fNIRS Bimodal System
Ge, S., Yang, Q., Wang, R., Lin, P., Gao, J., Leng, Y., Yang, Y., & Wang, H. (2017) · IEEE Access · doi:10.1109/access.2016.2637409 · Cited by 89
Casarotto, S., Bianchi, A. M., Cerutti, S., & Chiarenza, G. A. (2003) · Clinical Neurophysiology · doi:10.1016/j.clinph.2003.10.018 · Cited by 87
A Preliminary Study of Muscular Artifact Cancellation in Single-Channel EEG
Chen, X., Liu, A., Peng, H., & Ward, R. K. (2014) · Sensors · doi:10.3390/s141018370 · Cited by 83
Automatic removal of eye movement artifacts from the EEG using ICA and the dipole model
Zhou, W., & Gotman, J. (2009) · Progress in Natural Science Materials International · doi:10.1016/j.pnsc.2008.11.013 · Cited by 81
Removal of muscular artifacts in EEG signals: a comparison of linear decomposition methods
Frølich, L., & Dowding, I. (2018) · Brain Informatics · doi:10.1007/s40708-017-0074-6 · Cited by 79
Chen, X., He, C., & Peng, H. (2014) · Journal of Applied Mathematics · doi:10.1155/2014/261347 · Cited by 78
Mammone, N., & Morabito, F. C. (2014) · Entropy · doi:10.3390/e16126553 · Cited by 72
The Effect of Multiscale PCA De-noising in Epileptic Seizure Detection
Kevrić, J., & Subaşı, A. (2014) · Journal of Medical Systems · doi:10.1007/s10916-014-0131-0 · Cited by 63
Artifact suppression from EEG signals using data adaptive time domain filtering
Molla, M. K. I., Islam, M. R., Tanaka, T., & Rutkowski, T. M. (2012) · Neurocomputing · doi:10.1016/j.neucom.2012.05.009 · Cited by 62
Automatic removal of high-amplitude artefacts from single-channel electroencephalograms
Teixeira, A. R., Tomé, A. M., Lang, E. W., Gruber, P., & da Silva, A. M. (2006) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2006.06.003 · Cited by 62
Mannan, M. M. N., Kamran, M. A., Kang, S., & Jeong, M. Y. (2018) · Complexity · doi:10.1155/2018/4853741 · Cited by 59
Tamburro, G., Fiedler, P., Stone, D., Haueisen, J., & Comani, S. (2018) · PeerJ · doi:10.7717/peerj.4380 · Cited by 58
Simultaneous ocular and muscle artifact removal from EEG data by exploiting diverse statistics
Chen, X., Liu, A., Chen, Q., Liu, Y., Zou, L., & McKeown, M. J. (2017) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2017.06.013 · Cited by 56
Removal of the ocular artifacts from EEG data using a cascaded spatio-temporal processing
Liu, T., & Yao, D. (2006) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2006.03.009 · Cited by 48
Removal of ECG artifacts from EEG using a modified independent component analysis approach
Devuyst, S., Dutoit, T., Stenuit, P., Kerkhofs, M., & Stanus, E. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4650387 · Cited by 43
Autoregressive model in the Lp norm space for EEG analysis
Li, P., Wang, X., Li, F., Zhang, R., Ma, T., Peng, Y., Lei, X., Tian, Y., Guo, D., Liu, T., et al. (2014) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.11.007 · Cited by 42
L1 Norm based common spatial patterns decomposition for scalp EEG BCI
Li, P., Xu, P., Zhang, R., Guo, L., & Yao, D. (2013) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-12-77 · Cited by 42
Removal of High-Voltage Brain Stimulation Artifacts From Simultaneous EEG Recordings
Lee, S., McKeown, M. J., Wang, Z. J., & Chen, X. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2828808 · Cited by 42
Yang, B., Zhang, T., Zhang, Y., Liu, W., Wang, J., & Duan, K. (2017) · Cognitive Computation · doi:10.1007/s12559-017-9478-0 · Cited by 38
Filter-Bank Artifact Rejection: High performance real-time single-channel artifact detection for EEG
Dhindsa, K. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2017.06.012 · Cited by 31
Artifact Processing of Epileptic EEG Signals: An Overview of Different Types of Artifacts
Hamal, A. Q., & Rehman, A. (2013) · International Conference on Advanced Computer Science Applications and Technologies · doi:10.1109/acsat.2013.77 · Cited by 27
Dong, L., Zhang, Y., Zhang, R., Zhang, X., Gong, D., Valdes-Sosa, P. A., Xu, P., Luo, C., & Yao, D. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.01.006 · Cited by 24
Calcagno, S. (2014) · American Journal of Applied Sciences · doi:10.3844/ajassp.2014.57.68 · Cited by 24
Automatic Removal of Artifacts from EEG Data Using ICA and Exponential Analysis
Bian, N.-Y., Wang, B., Cao, Y., & Zhang, L. (2006) · Lecture notes in computer science · doi:10.1007/11760023_106 · Cited by 20
A New fMRI Informed Mixed-Norm Constrained Algorithm for EEG Source Localization
Wang, H., Lei, X., Zhan, Z., Yao, L., & Wu, X. (2018) · IEEE Access · doi:10.1109/access.2018.2792442 · Cited by 20
The Impact of Mspca Signal De-Noising In Real-Time Wireless Brain Computer Interface System
Kevrić, J., & Subaşı, A. (2015) · Southeast Europe Journal of Soft Computing · doi:10.21533/scjournal.v4i1.90 · Cited by 14
Cited by
Gu, X., Cao, Z., Jolfaei, A., Xu, P., Wu, D., Jung, T.-P., & Lin, C.-T. (2021) · IEEE/ACM Transactions on Computational Biology and Bioinformatics · doi:10.1109/tcbb.2021.3052811 · Cited by 395
EEG-Based Emotion Recognition: A State-of-the-Art Review of Current Trends and Opportunities
Suhaimi, N. S., Mountstephens, J., & Teo, J. (2020) · Computational Intelligence and Neuroscience · doi:10.1155/2020/8875426 · Cited by 357
Chaddad, A., Wu, Y., Kateb, R., & Bouridane, A. (2023) · Sensors · doi:10.3390/s23146434 · Cited by 305
Summary of over Fifty Years with Brain-Computer Interfaces—A Review
Kawala-Sterniuk, A., Browarska, N., Al-Bakri, A., Pelc, M., Zygarlicki, J., Sidikova, M., Martinek, R., & Gorzelanczyk, E. J. (2021) · Brain Sciences · doi:10.3390/brainsci11010043 · Cited by 292
A Review on Mental Stress Assessment Methods Using EEG Signals
Katmah, R., Al-Shargie, F., Tariq, U., Babiloni, F., Al-Mughairbi, F., & Al-Nashash, H. (2021) · Sensors · doi:10.3390/s21155043 · Cited by 276
Metadata
- Authors
- Jiang, X., Bian, G.-B., & Tian, Z.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2019-02-26
- Volume
- 19
- Issue
- 5
- Pages
- 987
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2915196348
- Cited by
- 826
- References
- 93
- FWCI
- 46.51
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.