Wide Field Spectral Imaging with Shifted Excitation Raman Difference Spectroscopy Using the Nod and Shuffle Technique
Open accessThe DOI matches its Crossref record; 59 of the 60 references it cites were found in a registry or an index.
Abstract
Wide field Raman imaging using the integral field spectroscopy approach was used as a fast, one shot imaging method for the simultaneous collection of all spectra composing a Raman image. For the suppression of autofluorescence and background signals such as room light, shifted excitation Raman difference spectroscopy (SERDS) was applied to remove background artifacts in Raman spectra. To reduce acquisition times in wide field SERDS imaging, we adapted the nod and shuffle technique from astrophysics and implemented it into a wide field SERDS imaging setup. In our adapted version, the nod corresponds to the change in excitation wavelength, whereas the shuffle corresponds to the shifting of charges up and down on a Charge-Coupled Device (CCD) chip synchronous to the change in excitation wavelength. We coupled this improved wide field SERDS imaging setup to diode lasers with 784.4/785.5 and 457.7/458.9 nm excitation and applied it to samples such as paracetamol and aspirin tablets, polystyrene and polymethyl methacrylate beads, as well as pork meat using multiple accumulations with acquisition times in the range of 50 to 200 ms. The results tackle two main challenges of SERDS imaging: gradual photobleaching changes the autofluorescence background, and multiple readouts of CCD detector prolong the acquisition time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures








Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Time-resolved or SERDS may provide a faster means of reducing fluorescence, and these approaches show promise in reducing fluorescence in Raman spectra of biological materials [19, 20].”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [19]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An optimal extraction algorithm for CCD spectroscopy
Horne, K. (1986) · Publications of the Astronomical Society of the Pacific · doi:10.1086/131801 · Cited by 1,923
Using Raman spectroscopy to characterize biological materials
Butler, H. J., Ashton, L., Bird, B., Cinque, G., Curtis, K., Dorney, J., Esmonde-White, K., Fullwood, N. J., Gardner, B., Martin-Hirsch, P. L., et al. (2016) · Nature Protocols · doi:10.1038/nprot.2016.036 · Cited by 1,309 · cited 1×
“It can be used for the pathological assessment of biological samples such as cells and tissues [1–5].”
MethodAutomated Method for Subtraction of Fluorescence from Biological Raman Spectra
Lieber, C. A., & Mahadevan-Jansen, A. (2003) · Applied Spectroscopy · doi:10.1366/000370203322554518 · Cited by 1,049 · cited 1×
“Computational methods correct Raman spectra for their background using mathematical algorithms such as extended multiplicative scatter correction (EMSC) [9,10], rubberband [11,12], sensitive nonlinear iterative peak (SNIP) [13,14], and polynomial fittings [15].”
MethodCell and tissue autofluorescence research and diagnostic applications
Monici, M. (2005) · Biotechnology Annual Review · doi:10.1016/s1387-2656(05)11007-2 · Cited by 887 · cited 1×
“lipids, and carbohydrates do not fluoresce at visible excitation, autofluorescence is often excited along with Raman scattering in biological samples [6].”
BackgroundVibrational spectroscopic imaging of living systems: An emerging platform for biology and medicine
Cheng, J.-X., & Xie, X. S. (2015) · Science · doi:10.1126/science.aaa8870 · Cited by 874 · cited 1×
“It can be used for the pathological assessment of biological samples such as cells and tissues [1–5].”
MethodMALDIquant: a versatile R package for the analysis of mass spectrometry data
Gibb, S., & Strimmer, K. (2012) · Bioinformatics · doi:10.1093/bioinformatics/bts447 · Cited by 695 · cited 1×
“Afterwards, the data were further processed using the computer language R [57] and the following R packages: hyperSpec [58], FITSio [59], Ramancal [60], pracma [61], MALDIquant [62], and viridis [63].”
MethodMartens, H., & Stark, E. (1991) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/0731-7085(91)80188-f · Cited by 515 · cited 1×
“Computational methods correct Raman spectra for their background using mathematical algorithms such as extended multiplicative scatter correction (EMSC) [9,10], rubberband [11,12], sensitive nonlinear iterative peak (SNIP) [13,14], and polynomial fittings [15].”
MethodReview of Fluorescence Suppression Techniques in Raman Spectroscopy
Wei, D., Chen, S., & Liu, Q. (2015) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2014.999936 · Cited by 334 · cited 1×
“Approaches to solve this challenge can be divided into computational and instrumental methods [8].”
BackgroundShreve, A. P., Cherepy, N. J., & Mathies, R. A. (1992) · Applied Spectroscopy · doi:10.1366/0003702924125122 · Cited by 312 · cited 1×
“Examples for these methods are time-gated methods [19,20], phase or wavelength modulation techniques [21–24], and shifted excitation Raman difference spectroscopy (SERDS) [25].”
MethodPMAS: The Potsdam Multi‐Aperture Spectrophotometer. II. The Wide Integral Field Unit PPak
Kelz, A., Verheijen, M. A. W., Roth, M. M., Bauer, S. M., Becker, T., Paschke, J., Popow, E., Sánchez, S. F., & Laux, U. (2006) · Publications of the Astronomical Society of the Pacific · doi:10.1086/497455 · Cited by 276 · cited 1×
“However, a far denser packing is possible and was already realized [53].”
BackgroundSelf-citationExtended multiplicative signal correction in vibrational spectroscopy, a tutorial
Afseth, N. K., & Kohler, A. (2012) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2012.03.004 · Cited by 263 · cited 3×
“After clustering the mean spectra of each cluster and assigning them to two different types of proteins and lipid, they compared the results of different wavelength shifts for SERDS with results based on EMSC and the 1st derivative of the EMSC corrected spectra.”
MethodKrafft, C., Schmitt, M., Schie, I. W., Cialla‐May, D., Matthäus, C., Bocklitz, T., & Popp, J. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201607604 · Cited by 234
Self-citationA new method using Raman spectroscopy for in vivo targeted brain cancer tissue biopsy
Desroches, J., Jermyn, M., Pinto, M., Picot, F., Tremblay, M.-A., Obaid, S., Marple, E., Urmey, K., Trudel, D., Soulez, G., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-20233-3 · Cited by 203
Krafft, C., Schie, I. W., Meyer, T., Schmitt, M., & Popp, J. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00564g · Cited by 198 · cited 1×
“It can be used for the pathological assessment of biological samples such as cells and tissues [1–5].”
MethodSelf-citationStewart, S., Priore, R. J., Nelson, M. P., & Treado, P. J. (2012) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-062011-143152 · Cited by 184
Microslit Nod‐Shuffle Spectroscopy: A Technique for Achieving Very High Densities of Spectra
Glazebrook, K., & Bland‐Hawthorn, J. (2001) · Publications of the Astronomical Society of the Pacific · doi:10.1086/318625 · Cited by 141 · cited 1×
“Another technique from astrophysics that could be translated to wide field SERDS imaging is the nod and shuffle concept [42–44].”
MethodGebrekidan, M. T., Knipfer, C., Stelzle, F., Popp, J., Will, S., & Braeuer, A. (2015) · Journal of Raman Spectroscopy · doi:10.1002/jrs.4775 · Cited by 130
Self-citationAlgorithm for fitting XRF, SEM and PIXE X-ray spectra backgrounds
Kneen, M. A., & Annegarn, H. J. (1996) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/0168-583x(95)00908-6 · Cited by 128 · cited 1×
“Computational methods correct Raman spectra for their background using mathematical algorithms such as extended multiplicative scatter correction (EMSC) [9,10], rubberband [11,12], sensitive nonlinear iterative peak (SNIP) [13,14], and polynomial fittings [15].”
MethodPeak Clipping Algorithms for Background Estimation in Spectroscopic Data
Morháč, M., & Matoušek, V. (2008) · Applied Spectroscopy · doi:10.1366/000370208783412762 · Cited by 114 · cited 2×
“Computational methods correct Raman spectra for their background using mathematical algorithms such as extended multiplicative scatter correction (EMSC) [9,10], rubberband [11,12], sensitive nonlinear iterative peak (SNIP) [13,14], and polynomial fittings [15].”
MethodAn algorithm for determination of peak regions and baseline elimination in spectroscopic data
Morháč, M. (2008) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2008.11.132 · Cited by 113 · cited 2×
“Computational methods correct Raman spectra for their background using mathematical algorithms such as extended multiplicative scatter correction (EMSC) [9,10], rubberband [11,12], sensitive nonlinear iterative peak (SNIP) [13,14], and polynomial fittings [15].”
MethodTime-gated Raman spectroscopy – a review
Kögler, M., & Heilala, B. (2020) · Measurement Science and Technology · doi:10.1088/1361-6501/abb044 · Cited by 107 · cited 1×
“Examples for these methods are time-gated methods [19,20], phase or wavelength modulation techniques [21–24], and shifted excitation Raman difference spectroscopy (SERDS) [25].”
MethodBergholt, M. S., Zheng, W., Lin, K., Wang, J., Xu, H., Ren, J., Ho, K. Y., Teh, M., Yeoh, K. G., & Huang, Z. (2014) · Analytical Chemistry · doi:10.1021/ac503287u · Cited by 81 · cited 1×
“Examples for the application of polynomial fitting are the correction during in vivo Raman studies of colorectal tissue [16] and brain cancer [17].”
BackgroundP3D: a general data-reduction tool for fiber-fed integral-field spectrographs
Sandín, C., Becker, T., Roth, M. M., Gerssen, J., Monreal‐Ibero, A., Böhm, P., & Weilbacher, P. (2010) · Astronomy and Astrophysics · doi:10.1051/0004-6361/201014022 · Cited by 75
Self-citationLight sheet Raman micro-spectroscopy
Müller, W., Kielhorn, M., Schmitt, M. P., Popp, J., & Heintzmann, R. (2016) · Optica · doi:10.1364/optica.3.000452 · Cited by 73
Self-citationRaman Imaging with a Fiber-Coupled Multichannel Spectrograph
Schmälzlin, E., Moralejo, B., Rutowska, M., Monreal‐Ibero, A., Sandín, C., Tarcea, N., Popp, J., & Roth, M. M. (2014) · Sensors · doi:10.3390/s141121968 · Cited by 71 · cited 2×
“spectrograph module, was successfully used for Raman and SERDS imaging [35,36].”
MethodSelf-citationBasic principles of integral field spectroscopy
Allington-Smith, J. R. (2006) · New Astronomy Reviews · doi:10.1016/j.newar.2006.02.024 · Cited by 69 · cited 6×
“An IFS spectrograph with 400 spaxels, built as a clone of a M.U.S.E. spectrograph module, was successfully used for Raman and SERDS imaging [35,36].”
MethodInfluentialKnipfer, C., Motz, J., Adler, W., Brunner, K., Gebrekidan, M. T., Hankel, R. F., Agaimy, A., Will, S., Braeuer, A., Neukam, F. W., et al. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.003252 · Cited by 68 · cited 1×
“The investigated samples were molar tooth slices and in vivo human skin [28], algae produced complex polysaccharides [29], tissues from different animals [30–32], ex vivo oral squamous cell carcinoma biopsies [33], and spores of Aspergillus nidulans conidia [34].”
BackgroundCordero, E., Korinth, F., Stiebing, C., Krafft, C., Schie, I., & Popp, J. (2017) · Sensors · doi:10.3390/s17081724 · Cited by 58 · cited 2×
“[7] measured a beef steak in this fashion.”
BackgroundSelf-citationModulated Raman Spectroscopy for Enhanced Cancer Diagnosis at the Cellular Level
Luca, A. C. D., Dholakia, K., & Mazilu, M. (2015) · Sensors · doi:10.3390/s150613680 · Cited by 52 · cited 1×
“Examples for these methods are time-gated methods [19,20], phase or wavelength modulation techniques [21–24], and shifted excitation Raman difference spectroscopy (SERDS) [25].”
MethodNoack, K., Eskofier, B. M., Kiefer, J., Dilk, C., Bilow, G., Schirmer, M., Buchholz, R., & Leipertz, A. (2013) · The Analyst · doi:10.1039/c3an01158e · Cited by 50 · cited 1×
“The investigated samples were molar tooth slices and in vivo human skin [28], algae produced complex polysaccharides [29], tissues from different animals [30–32], ex vivo oral squamous cell carcinoma biopsies [33], and spores of Aspergillus nidulans conidia [34].”
BackgroundRaman spectroscopy for rapid intra-operative margin analysis of surgically excised tumour specimens
Hubbard, T. J. E., Shore, A. C., & Stone, N. (2019) · The Analyst · doi:10.1039/c9an01163c · Cited by 48 · cited 1×
“It can be used for the pathological assessment of biological samples such as cells and tissues [1–5].”
MethodAriese, F., Meuzelaar, H., Kerssens, M. M., Buijs, J. B., & Gooijer, C. (2009) · The Analyst · doi:10.1039/b821437a · Cited by 46 · cited 1×
“Examples for these methods are time-gated methods [19,20], phase or wavelength modulation techniques [21–24], and shifted excitation Raman difference spectroscopy (SERDS) [25].”
MethodMartins, M. A. D. S., Ribeiro, D. G., Pereira dos Santos, E. A., Martin, A. A., Fontes, A., & Martinho, H. D. S. (2010) · Biomedical Optics Express · doi:10.1364/boe.1.000617 · Cited by 43 · cited 1×
“The investigated samples were molar tooth slices and in vivo human skin [28], algae produced complex polysaccharides [29], tissues from different animals [30–32], ex vivo oral squamous cell carcinoma biopsies [33], and spores of Aspergillus nidulans conidia [34].”
BackgroundScientific detectors for astronomy 2005
Beletic, J. E., Beletic, J. W., & Amico, P. (2006) · Springer eBooks · doi:10.1007/1-4020-4330-9 · Cited by 39
Sowoidnich, K., & Kronfeldt, H.-D. (2012) · ISRN Spectroscopy · doi:10.5402/2012/256326 · Cited by 39
A portable shifted excitation Raman difference spectroscopy system: device and field demonstration
Maiwald, M., Müller, A., Sumpf, B., & Tränkle, G. (2016) · Journal of Raman Spectroscopy · doi:10.1002/jrs.4953 · Cited by 37 · cited 1×
“This has been shown for single spectra before [67–69] but not for a complete Raman image or, in our case, a wide field Raman image.”
BackgroundSelf-citationCordero, E., Rüger, J., Marti, D., Mondol, A. S., Hasselager, T., Mogensen, K., Hermann, G. G., Popp, J., & Schie, I. W. (2019) · Journal of Biophotonics · doi:10.1002/jbio.201960025 · Cited by 37 · cited 1×
“EMSC was used for the autofluorescence correction of Raman spectra of bladder biopsies [18].”
MethodSelf-citationKorinth, F., Mondol, A. S., Stiebing, C., Schie, I. W., Krafft, C., & Popp, J. (2020) · Scientific Reports · doi:10.1038/s41598-020-67897-4 · Cited by 35 · cited 1×
“The target classification can be derived directly from the SERDS spectra, which was demonstrated for pollen [26], or from algorithm-based reconstructed Raman spectra, which was demonstrated for formalin fixed patient samples of breast tumors [27].”
BackgroundSelf-citationComparison of time and frequency domain methods for rejecting fluorescence from Raman spectra
Wirth, M. J., & Chou, S. H. (1988) · Analytical Chemistry · doi:10.1021/ac00169a009 · Cited by 30 · cited 1×
“Examples for these methods are time-gated methods [19,20], phase or wavelength modulation techniques [21–24], and shifted excitation Raman difference spectroscopy (SERDS) [25].”
MethodDochow, S., Bergner, N., Krafft, C., Clement, J. H., Mazilu, M., Praveen, B. B., Ashok, P. C., Marchington, R., Dholakia, K., & Popp, J. (2013) · Analytical Methods · doi:10.1039/c3ay40193f · Cited by 27 · cited 1×
“Examples for these methods are time-gated methods [19,20], phase or wavelength modulation techniques [21–24], and shifted excitation Raman difference spectroscopy (SERDS) [25].”
MethodSelf-citationBreast Tumor Analysis Using Shifted-Excitation Raman Difference Spectroscopy (SERDS)
Gebrekidan, M. T., Erber, R., Hartmann, A., Fasching, P. A., Emons, J., Beckmann, M. W., & Braeuer, A. (2018) · Technology in Cancer Research & Treatment · doi:10.1177/1533033818782532 · Cited by 25 · cited 1×
“The target classification can be derived directly from the SERDS spectra, which was demonstrated for pollen [26], or from algorithm-based reconstructed Raman spectra, which was demonstrated for formalin fixed patient samples of breast tumors [27].”
BackgroundEtaloning, fluorescence and ambient light suppression by modulated wavelength Raman spectroscopy
Dochow, S., Bergner, N., Matthäus, C., Praveen, B. B., Ashok, P. C., Mazilu, M., Krafft, C., Dholakia, K., & Popp, J. (2012) · Biomedical Spectroscopy and Imaging · doi:10.3233/bsi-120031 · Cited by 24 · cited 1×
“This has been shown for single spectra before [67–69] but not for a complete Raman image or, in our case, a wide field Raman image.”
BackgroundSelf-citationBonifacio, A., Beleites, C., & Sergo, V. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-8321-7 · Cited by 24 · cited 1×
“For this analysis, the Pearson correlation distance between the SERDS spectra was first calculated and then clustered following Ward’s minimum variance method [64].”
MethodOptical 3D‐Spectroscopy for Astronomy
Bacon, R. M., & Monnet, G. J. (2017) · Wiley eBooks · doi:10.1002/9783527674824 · Cited by 23
Applications of Spatial Light Modulators in Raman Spectroscopy
Sinjab, F., Liao, Z., & Notingher, I. (2019) · Applied Spectroscopy · doi:10.1177/0003702819834575 · Cited by 23
Nonscanning large-area Raman imaging for ex vivo/in vivo skin cancer discrimination
Schmälzlin, E., Moralejo, B., Gersonde, I. H., Schleusener, J., Darvin, M. E., Thiede, G., & Roth, M. M. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.10.105001 · Cited by 19
Self-citationCraig, D., Mazilu, M., & Dholakia, K. (2015) · PLoS ONE · doi:10.1371/journal.pone.0123334 · Cited by 17 · cited 1×
“Examples for these methods are time-gated methods [19,20], phase or wavelength modulation techniques [21–24], and shifted excitation Raman difference spectroscopy (SERDS) [25].”
MethodSowoidnich, K., Towrie, M., Maiwald, M., Sumpf, B., & Matousek, P. (2019) · Applied Spectroscopy · doi:10.1177/0003702819859352 · Cited by 15 · cited 1×
“[45,46] as a Charge-Shifting Charge-Coupled Device, based on the previous works of Heming et al.”
MethodSelf-citationUltrafast imaging Raman spectroscopy of large-area samples without stepwise scanning
Schmälzlin, E., Moralejo, B., Bodenmüller, D., Darvin, M. E., Thiede, G., & Roth, M. M. (2016) · Journal of sensors and sensor systems · doi:10.5194/jsss-5-261-2016 · Cited by 14 · cited 5×
“In the original configuration of the spectrograph, this was not the case [36]; thus, the CCD chip had to be rotated by 90◦.”
BackgroundMethodSelf-citationHan, Z., Strycker, B. D., Commer, B., Wang, K., Shaw, B. D., Scully, M. O., & Sokolov, A. V. (2020) · Scientific Reports · doi:10.1038/s41598-020-62112-w · Cited by 14 · cited 1×
“The investigated samples were molar tooth slices and in vivo human skin [28], algae produced complex polysaccharides [29], tissues from different animals [30–32], ex vivo oral squamous cell carcinoma biopsies [33], and spores of Aspergillus nidulans conidia [34].”
BackgroundSowoidnich, K., Towrie, M., & Matousek, P. (2019) · Journal of Raman Spectroscopy · doi:10.1002/jrs.5597 · Cited by 11 · cited 1×
“This has been shown for single spectra before [67–69] but not for a complete Raman image or, in our case, a wide field Raman image.”
BackgroundMoralejo, B., Roth, M. M., Godefroy, P., Fechner, T., Bauer, S., Schmälzlin, E., Kelz, A., & Haynes, R. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2232539 · Cited by 6 · cited 1×
“A detailed description of the spectrograph and detector system can be found in [49] and [50].”
BackgroundSelf-citationSumpf, B., Müller, A., & Maiwald, M. (2019) · Plasmonics in Biology and Medicine · doi:10.1117/12.2507425 · Cited by 6 · cited 1×
“90 nm in a conduction cooled package mount with a 25 × 25 mm2 footprint was designed and realized [51].”
MethodSelf-citationUltra-Deep Optical Spectroscopy with PMAS. Using the Nod-and-Shuffle Technique
Roth, M. M., Fechner, T., Wolter, D., Kelz, A., & Becker, T. (2002) · Experimental Astronomy · doi:10.1023/b:expa.0000004352.56068.a8 · Cited by 5
Self-citationMoralejo, B., Schmälzlin, E., Bodenmüller, D., Fechner, T., & Roth, M. M. (2017) · Journal of Raman Spectroscopy · doi:10.1002/jrs.5268 · Cited by 4 · cited 1×
“A detailed description of the spectrograph and detector system can be found in [49] and [50].”
BackgroundSelf-citationSowoidnich, K., & Kronfeldt, H. (2018) · Biophotonics: Photonic Solutions for Better Health Care VI · doi:10.1117/12.2306659 · Cited by 3
Sowoidnich, K., Maiwald, M., Sumpf, B., Towrie, M., & Matousek, P. (2020) · Biomedical Vibrational Spectroscopy: Advances in Research and Industry · doi:10.1117/12.2544752 · Cited by 2 · cited 1×
“[45,46] as a Charge-Shifting Charge-Coupled Device, based on the previous works of Heming et al.”
MethodSelf-citationFITSio: FITS (Flexible Image Transport System) Utilities
Harris, A. (2008) · doi:10.32614/cran.package.fitsio · Cited by 2
6.4 - Bildgebende Differenz-Raman-Spektroskopie mit "Nod-and-Shuffle"-Technik
Schmälzlin, E., Urrutia, T., Roth, M., Korinth, F., Stiebing, C., Krafft, C., & Popp, J. (2019) · Tagungsband · doi:10.5162/14dss2019/6.4 · Cited by 1 · cited 1×
“In comparison to a previous conference proceeding paper [48], this publication provides more details of the nod and shuffle approach and the laser diode development, and it demonstrates wide field spectral imaging with nod and shuffle SERDS for a tissue specimen for the first time.”
ResultSelf-citation
Research works printed but not linked: 1
- Heming R. Herzog H. Deckert V. Optical CCD lock-in device for Raman difference spectroscopy DGaO Proc. 2008 109 33
Cited by
The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing
Esmonde-White, K. A., Cuellar, M., & Lewis, I. R. (2022) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-021-03727-4 · Cited by 152
“Time-resolved or SERDS may provide a faster means of reducing fluorescence, and these approaches show promise in reducing fluorescence in Raman spectra of biological materials [19, 20].”
BackgroundFang, S., Wu, S., Chen, Z., He, C., Lin, L., & Ye, J. (2024) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2024.117578 · Cited by 143
Optics miniaturization strategy for demanding Raman spectroscopy applications
Ilchenko, O. O., Pilgun, Y., Михайлович, К. А., Slobodianiuk, D. V., Göksel, Y., Dumont, E., Vaut, L., Mazzoni, C., Morelli, L., Boisen, S., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-47044-7 · Cited by 53
Schie, I. W., Stiebing, C., & Popp, J. (2021) · Journal of Biomedical Optics · doi:10.1117/1.jbo.26.8.080601 · Cited by 28
Self-citationKorinth, F., Shaik, T. A., Popp, J., & Krafft, C. (2021) · The Analyst · doi:10.1039/d1an01376a · Cited by 25
Self-citation
Metadata
- Authors
- Korinth, F., Schmälzlin, E., Stiebing, C., Urrutia, T., Micheva, G., Sandin, C., Müller, A., Maiwald, M., Sumpf, B., Krafft, C., Tränkle, G., Roth, M. M., & Popp, J.
- Affiliations
- Leibniz Institute of Photonic Technology (DE)
- Leibniz Institute for Astrophysics Potsdam (DE)
- Sandin Advanced Visualization, Tylögränd 14, 12156 Johanneshov, Sweden
- Ferdinand-Braun-Institut (DE)
- Corresponding author
- Krafft, Christoph
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2020-11-24
- Volume
- 20
- Issue
- 23
- Pages
- 6723
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC7727830
- OpenAlex
- W3107090361
- Cited by
- 13
- References
- 60
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 4 · 2022: 3 · 2021: 3
- FWCI
- 0.71
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- arXiv (Cornell University) (publishedVersion)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- RENATE (submittedVersion, cc-by-nc-nd)
- arXiv (Cornell University) (cc-by)
- RENATE (cc-by)
- Funders
- Senate Competition Committee of the Leibniz Association (SAW-2016-IPHT-2)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Social Sciences › Arts and Humanities › Archeology (arts and humanities) › Cultural Heritage Materials Analysis
- Keywords
- shifted excitation Raman difference spectroscopy, integral field spectroscopy, autofluorescence suppression, photobleaching, acquisition time reduction, laser diode excitation, tablets, pork
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.