CoChat

A Comprehensive Review of Continuous Glucose Monitoring Accuracy during Exercise Periods

Muñoz Fabra, Elena, Díez, José-Luis, Bondia, Jorge, Laguna Sanz, Alejandro José · 2021 · Sensors
Cited by 42

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Continuous Glucose Monitoring (CGM) has been a springboard of new diabetes management technologies such as integrated sensor-pump systems, the artificial pancreas, and more recently, smart pens. It also allows patients to make better informed decisions compared to a few measurements per day from a glucometer. However, CGM accuracy is reportedly affected during exercise periods, which can impact the effectiveness of CGM-based treatments. In this review, several studies that used CGM during exercise periods are scrutinized. An extensive literature review of clinical trials including exercise and CGM in type 1 diabetes was conducted. The gathered data were critically analysed, especially the Mean Absolute Relative Difference (MARD), as the main metric of glucose accuracy. Most papers did not provide accuracy metrics that differentiated between exercise and rest (non-exercise) periods, which hindered comparative data analysis. Nevertheless, the statistic results confirmed that CGM during exercise periods is less accurate.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s21020479

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 73

  1. Kumareswaran, 2013, Accuracy of continuous glucose monitoring during exercise in type 1 diabetes pregnancy, Diabetes Technol. Ther., 15, 223, 10.1089/dia.2012.0292 · DOI
  2. Li, 2019, Time Lag and Accuracy of Continuous Glucose Monitoring during High Intensity Interval Training in Adults with Type 1 Diabetes, Diabetes Technol. Ther., 21, 286, 10.1089/dia.2018.0387 · DOI
  3. Adolfsson, 2011, Continuous glucose monitoring system during physical exercise in adolescents with type 1 diabetes, Acta Paediatr. Int. J. Paediatr., 100, 1603, 10.1111/j.1651-2227.2011.02390.x · DOI
  4. Herrington, 2012, Comparison of glucose monitoring methods during steady-state exercise in women, Nutrients, 4, 1282, 10.3390/nu4091282 · DOI
  5. Giani, 2018, Performance of the Flash Glucose Monitoring System during exercise in youth with Type 1 diabetes, Diabetes Res. Clin. Pract., 146, 321, 10.1016/j.diabres.2018.10.001 · DOI
  6. Iscoe, 2006, Efficacy of continuous real-time blood glucose monitoring during and after prolonged high-intensity cycling exercise: Spinning with a continuous glucose monitoring system, Diabetes Technol. Ther., 8, 627, 10.1089/dia.2006.8.627 · DOI · Paper page
  7. Laguna, A.J., Díez, J.L., Giménez, M., and Bondia, J. (2019). Enhanced accuracy of continuous glucose monitoring during exercise through physical activity tracking integration. Sensors, 19. · DOI
  8. Zaharieva, 2020, Advances in Exercise, Physical Activity, and Diabetes, Diabetes Technol. Ther., 22, S109, 10.1089/dia.2020.2508 · DOI
  9. Castle, 2019, How Well Do Continuous Glucose Monitoring Systems Perform during Exercise?, Diabetes Technol. Ther., 21, 305, 10.1089/dia.2019.0132 · DOI
  10. Hansen, 2018, Accuracy, satisfaction and usability of a flash glucose monitoring system among children and adolescents with type 1 diabetes attending a summer camp, Pediatr. Diabetes, 19, 1276, 10.1111/pedi.12723 · DOI
  11. Damiano, 2014, A comparative effectiveness analysis of three continuous glucose monitors: The Navigator, G4 Platinum, and Enlite, J. Diabetes Sci. Technol., 8, 699, 10.1177/1932296814532203 · DOI · Paper page
  12. (2020, October 05). National Center for Biotechnology Information, Available online: https://www.ncbi.nlm.nih.gov/.
  13. DerSimonian, 1986, Meta-analysis in clinical trials, Control. Clin. Trials, 7, 177, 10.1016/0197-2456(86)90046-2 · DOI · Paper page
  14. Lee, 2016, Comparison of Two Meta-Analysis Methods: Inverse-Variance-Weighted Average and Weighted Sum of Z-Scores, Genom. Inform., 14, 173, 10.5808/GI.2016.14.4.173 · DOI · Paper page
  15. Jackson, 2019, A new justification of the Hartung–Knapp method for random-effects meta-analysis based on weighted least squares regression, Res. Synth. Methods, 10, 515, 10.1002/jrsm.1356 · DOI · Paper page
  16. Fayolle, 2006, Accuracy of continuous subcutaneous glucose monitoring with the GlucoDay® in type 1 diabetic patients treated by subcutaneous insulin infusion during exercise of low versus high intensity, Diabetes Metab., 32, 313, 10.1016/S1262-3636(07)70285-9 · DOI
  17. Adolfsson, 2008, The benefits of continuous glucose monitoring and a glucose monitoring schedule in individuals with type 1 diabetes during recreational diving, J. Diabetes Sci. Technol., 2, 778, 10.1177/193229680800200505 · DOI
  18. Riddell, 2011, Preventing exercise-induced hypoglycaemia in type 1 diabetes using real-time continuous glucose monitoring and a new carbohydrate intake algorithm: An observational field study, Diabetes Technol. Ther., 13, 819, 10.1089/dia.2011.0052 · DOI · Paper page
  19. Yardley, 2012, Effects of performing resistance exercise before versus after aerobic exercise on glycemia in type 1 diabetes, Diabetes Care, 35, 669, 10.2337/dc11-1844 · DOI · Paper page
  20. Kumareswaran, K., Elleri, D., Allen, J.M., Caldwell, K., Westgate, K., Brage, S., Raymond-Barker, P., Nodale, M., Wilinska, M.E., and Amiel, S.A. (2013). Physical activity energy expenditure and glucose levels in pregnant women with type 1 diabetes during free-living and controlled conditions. Diabetes, 36. · DOI
  21. Yardley, 2013, Point Accuracy of interstitial continuous glucose monitoring during exercise in type 1 diabetes, Diabetes Technol. Ther., 15, 46, 10.1089/dia.2012.0182 · DOI · Paper page
  22. Radermecker, 2013, Accuracy assessment of online glucose monitoring by a subcutaneous enzymatic glucose sensor during exercise in patients with type 1 diabetes treated by continuous subcutaneous insulin infusion, Diabetes Metab., 39, 258, 10.1016/j.diabet.2012.12.004 · DOI
  23. Yousef, 2014, Glucose changes and working memory in individuals with type 1 diabetes during air pressure changes simulating skydiving, Diabetes Technol. Ther., 16, 56, 10.1089/dia.2013.0110 · DOI
  24. Campbell, 2015, Simulated games activity vs continuous running exercise: A novel comparison of the glycemic and metabolic responses in T1DM patients, Scand. J. Med. Sci. Sports, 25, 216, 10.1111/sms.12192 · DOI
  25. Moser, O., Tschakert, G., Mueller, A., Groeschl, W., Pieber, T.R., Obermayer-Pietsch, B., Koehler, G., and Hofmann, P. (2015). Effects of high-intensity interval exercise versus moderate continuous exercise on glucose homoeostasis and hormone response in patients with type 1 diabetes mellitus using novel ultra-long-acting insulin. PLoS ONE, 10. · DOI · Paper page
  26. Eijsvogels, 2016, Glycemic control during consecutive days with prolonged walking exercise in individuals with type 1 diabetes mellitus, Diabetes Res. Clin. Pract., 117, 74, 10.1016/j.diabres.2016.04.053 · DOI
  27. Moser, O., Mader, J.K., Tschakert, G., Mueller, A., Groeschl, W., Pieber, T.R., Koehler, G., Messerschmidt, J., and Hofmann, P. (2016). Accuracy of continuous glucose monitoring (CGM) during continuous and high-intensity interval exercise in patients with type 1 diabetes mellitus. Nutrients, 8. · DOI · Paper page
  28. Bally, 2016, Accuracy of continuous glucose monitoring during differing exercise conditions, Diabetes Res. Clin. Pract., 112, 1, 10.1016/j.diabres.2015.11.012 · DOI
  29. Taleb, 2016, Comparison of Two Continuous Glucose Monitoring Systems, Dexcom G4 Platinum and Medtronic Paradigm Veo Enlite System, at Rest and during Exercise, Diabetes Technol. Ther., 18, 561, 10.1089/dia.2015.0394 · DOI · Paper page
  30. McAuley, S.A., Horsburgh, J.C., Ward, G.M., La Gerche, A., Gooley, J.L., Jenkins, A.J., MacIsaac, R.J., and O’Neal, D.N. (2016). Insulin pump basal adjustment for exercise in type 1 diabetes: A randomised crossover study. Diabetologia, 59. · DOI
  31. Aberer, 2017, Evaluation of subcutaneous glucose monitoring systems under routine environmental conditions in patients with type 1 diabetes, Diabetes Obes. Metab., 19, 1051, 10.1111/dom.12907 · DOI · Paper page
  32. Gawrecki, 2017, High-intensity Exercise in Men with Type 1 Diabetes and Mode of Insulin Therapy, Int. J. Sports Med., 38, 329, 10.1055/s-0042-123046 · DOI
  33. Jayawardene, 2017, Closed-loop insulin delivery for adults with type 1 diabetes undertaking high-intensity interval exercise versus moderate-intensity exercise: A randomized, crossover study, Diabetes Technol. Ther., 19, 340, 10.1089/dia.2016.0461 · DOI
  34. Reddy, 2018, The effect of exercise on sleep in adults with type 1 diabetes, Diabetes Obes. Metab., 20, 443, 10.1111/dom.13065 · DOI
  35. Bertachi, 2018, Blood glucose monitoring during aerobic and anaerobic physical exercise using a new artificial pancreas system, Endocrinol. Diabetes Nutr., 65, 342
  36. Larose, 2018, Comparison of Continuous Glucose Monitoring with Capillary Glucose Levels and Dynamics of Accuracy Changes during Moderate-Intensity Aerobic Exercise in Patients with Type 1 Diabetes, Can. J. Diabetes, 42, S51, 10.1016/j.jcjd.2018.08.157 · doi:10.1016/j.jcjd.2018.08.157
  37. Aronson, 2019, Optimal insulin correction factor in post–high-intensity exercise hyperglycemia in adults with type 1 diabetes: The FIT study, Diabetes Care, 42, 10, 10.2337/dc18-1475 · DOI
  38. Reddy, R., Wittenberg, A., Castle, J.R., El Youssef, J., Winters-Stone, K., Gillingham, M., and Jacobs, P.G. (2018). Effect of Aerobic and Resistance Exercise on Glycemic Control in Adults With Type 1 Diabetes, Elsevier Inc. · doi:10.2337/db18-756-p
  39. Biagi, L., Bertachi, A., Quirós, C., Giménez, M., Conget, I., Bondia, J., and Vehí, J. (2018). Accuracy of continuous glucose monitoring before, during, and after aerobic and anaerobic exercise in patients with type 1 diabetes mellitus. Biosensors, 8. · DOI · Paper page
  40. Abdulrahman, 2018, Annals of Clinical Case Reports The Use of Continuous Glucose Monitoring for Sport in, Ann. Clin. Case Rep. Diabetol., 3, 1
  41. Moser, 2019, A head-to-head comparison of personal and professional continuous glucose monitoring systems in people with type 1 diabetes: Hypoglycaemia remains the weak spot, Diabetes Obes. Metab., 21, 1043, 10.1111/dom.13598 · DOI
  42. Steineck, 2019, Comparison of Continuous Glucose Monitoring Accuracy between Abdominal and Upper Arm Insertion Sites, Diabetes Technol. Ther., 21, 295, 10.1089/dia.2019.0014 · DOI · Paper page
  43. Burckhardt, 2019, Use of Continuous Glucose Monitoring Trends to Facilitate Exercise in Children with Type 1 Diabetes, Diabetes Technol. Ther., 21, 51, 10.1089/dia.2018.0292 · DOI
  44. Forlenza, 2019, Performance of Omnipod Personalized Model Predictive Control Algorithm with Moderate Intensity Exercise in Adults with Type 1 Diabetes, Diabetes Technol. Ther., 21, 265, 10.1089/dia.2019.0017 · DOI
  45. Larose, 2019, Changes in Accuracy of Continuous Glucose Monitoring Using Dexcom G4 Platinum over the Course of Moderate Intensity Aerobic Exercise in Type 1 Diabetes, Diabetes Technol. Ther., 21, 364, 10.1089/dia.2018.0400 · DOI
  46. Zaharieva, 2019, Lag Time Remains with Newer Real-Time Continuous Glucose Monitoring Technology during Aerobic Exercise in Adults Living with Type 1 Diabetes, Diabetes Technol. Ther., 21, 313, 10.1089/dia.2018.0364 · DOI · Paper page
  47. Moser, 2019, Impact of physical exercise on sensor performance of the FreeStyle Libre intermittently viewed continuous glucose monitoring system in people with Type 1 diabetes: A randomized crossover trial, Diabet. Med., 36, 606, 10.1111/dme.13909 · DOI
  48. Zaharieva, 2020, No Disadvantage to Insulin Pump Off vs Pump On During Intermittent High-Intensity Exercise in Adults With Type 1 Diabetes, Can. J. Diabetes, 44, 162, 10.1016/j.jcjd.2019.05.015 · DOI
  49. Yardley, 2019, Morning (Fasting) vs Afternoon Resistance Exercise in Individuals with Type 1 Diabetes: A Randomized Crossover Study, J. Clin. Endocrinol. Metab., 104, 5217, 10.1210/jc.2018-02384 · DOI
  50. Steineck, 2019, Preserved glucose response to low-dose glucagon after exercise in insulin-pump-treated individuals with type 1 diabetes: A randomised crossover study, Diabetologia, 62, 582, 10.1007/s00125-018-4807-8 · DOI
  51. Gawrecki, 2019, Physical workload and glycemia changes during football matches in adolescents with type 1 diabetes can be comparable, Acta Diabetol., 56, 1191, 10.1007/s00592-019-01371-0 · DOI
  52. Lee, 2020, High-intensity interval exercise and hypoglycaemia minimisation in adults with type 1 diabetes: A randomised cross-over trial, J. Diabetes Complicat., 34, 107514, 10.1016/j.jdiacomp.2019.107514 · DOI
  53. Moser, O., Eckstein, M.L., Mueller, A., Birnbaumer, P., Aberer, F., Koehler, G., Sourij, C., Kojzar, H., Pferschy, P., and Dietz, P. (2019). Pre-exercise blood glucose levels determine the amount of orally administered carbohydrates during physical exercise in individuals with type 1 diabetes—A randomized cross-over trial. Nutrients, 11. · DOI
  54. Scott, 2019, Fasted high-intensity interval and moderate-intensity exercise do not lead to detrimental 24-hour blood glucose profiles, J. Clin. Endocrinol. Metab., 104, 111, 10.1210/jc.2018-01308 · DOI
  55. Williams, D., Deere, R., Moser, O., McCarthy, O., Pitt, J., Bracken, R., Sourij, H., Bain, S., Eckstein, M., and Hayes, J. (2019). Performance of the Freestyle Libre flash glucose monitoring (flash GM) system in individuals with type 1 diabetes: A secondary outcome analysis of a randomized crossover trial. Diabetes Obes. Metab., 21. · DOI · Paper page
  56. Scott, 2018, High-Intensity Interval Training Improves Aerobic Capacity Without a Detrimental Decline in Blood Glucose in People with Type 1 Diabetes, J. Clin. Endocrinol. Metab., 104, 604, 10.1210/jc.2018-01309 · DOI
  57. Mccarthy, 2020, Glycemic responses to strenuous training in male professional cyclists with type 1 diabetes: A prospective observational study, BMJ Open Diabetes Res. Care, 8, 1, 10.1136/bmjdrc-2020-001245 · DOI
  58. Brockman, 2020, Sex-Related Differences in Blood Glucose Responses to Resistance Exercise in Adults With Type 1 Diabetes: A Secondary Data Analysis, Can. J. Diabetes, 44, 267, 10.1016/j.jcjd.2019.08.006 · DOI
  59. Fokkert, M.J., Dijk, P.R., Edens, M.A., Díez, A., Slingerland, R.J., Gans, R.O.B., Delgado, E., and Bilo, H.J.G. (2020). Performance of continuous glucose monitoring devices during intensive exercise conditions in people with diabetes: The Mont Blanc experience. Diabet. Med. · DOI
  60. Guillot, F.H., Jacobs, P.G., Wilson, L.M., El Youssef, J., Gabo, V.B., Branigan, D.L., Tyler, N.S., Ramsey, K., Riddell, M.C., and Castle, J.R. (2020). Accuracy of the dexcom G6 glucose sensor during aerobic, resistance, and interval exercise in adults with type 1 diabetes. Biosensors, 10. · DOI
  61. Mastrototaro, 2008, The accuracy and efficacy of real-time continuous glucose monitoring sensor in patients with type 1 diabetes, Diabetes Technol. Ther., 10, 385, 10.1089/dia.2007.0291 · DOI · Paper page
  62. Slover, 2018, Accuracy of a Fourth-Generation Continuous Glucose Monitoring System in Children and Adolescents with Type 1 Diabetes, Diabetes Technol. Ther., 20, 576, 10.1089/dia.2018.0109 · DOI · Paper page
  63. Rodbard, 2016, Continuous Glucose Monitoring: A Review of Successes, Challenges, and Opportunities, Diabetes Technol. Ther., 18, S23, 10.1089/dia.2015.0417 · DOI · Paper page
  64. Nakamura, 2015, The accuracy and efficacy of the dexcom G4 platinum continuous glucose monitoring system, J. Diabetes Sci. Technol., 9, 1021, 10.1177/1932296815577812 · DOI · Paper page
  65. Gross, 2000, Performance evaluation of the MiniMed® continuous glucose monitoring system during patient home use, Diabetes Technol. Ther., 2, 49, 10.1089/152091500316737 · DOI · Paper page
  66. Sinha, 2017, A Comparison of Time Delay in Three Continuous Glucose Monitors for Adolescents and Adults, J. Diabetes Sci. Technol., 11, 1132, 10.1177/1932296817704443 · DOI · Paper page
  67. Higgins JPT, G.S. (2019). Cochrane Handbook for Systematic Reviews of Interventions, Wiley Blackwell. · DOI · Paper page
  68. Wan, X., Wang, W., Liu, J., and Tong, T. (2014). Estimating the sample mean and standard deviation from the sample size, median, range and/or interquartile range. BMC Med. Res. Methodol., 14. · DOI · Paper page
  69. Szadkowska, 2018, Flash Glucose Measurements in Children with Type 1 Diabetes in Real-Life Settings: To Trust or Not to Trust?, Diabetes Technol. Ther., 20, 17, 10.1089/dia.2017.0287 · DOI · Paper page
  70. Huyett, L.M., Dassau, E., Zisser, H.C., and Doyle, F.J. (2015, January 1–3). The impact of glucose sensing dynamics on the closed-loop artificial pancreas. Proceedings of the 2015 American Control Conference (ACC), Chicago, IL, USA. · DOI
  71. Adolfsson, 2009, Accuracy and reliability of continuous glucose monitoring in individuals with type 1 diabetes during recreational diving, Diabetes Technol. Ther., 11, 493, 10.1089/dia.2009.0017 · DOI
  72. Riddell, M.C., Pooni, R., Yavelberg, L., Li, Z., Kollman, C., Brown, R.E., Li, A., and Aronson, R. (2019). Reproducibility in the cardiometabolic responses to high-intensity interval exercise in adults with type 1 diabetes. Diabetes Res. Clin. Pract., 148. · DOI
  73. Reiterer, 2017, Significance and Reliability of MARD for the Accuracy of CGM Systems, J. Diabetes Sci. Technol., 11, 59, 10.1177/1932296816662047 · DOI · Paper page

Cited by

See all 42

Metadata

Authors
Muñoz Fabra, E., Díez, J.-L., Bondia, J., & Laguna Sanz, A. J.
Affiliations
  • Instituto Universitario de Automática e Informática Industrial, Universitat Politècnica de València, Camino de Vera s/n, 46022 València, Spain
  • Centro de Investigación Biomédica en Red de Diabetes y Enfermedades Metabólicas Asociadas (CIBERDEM), Instituto de Salud Carlos III, 28029 Madrid, Spain
Venue
Sensors
Publisher
MDPI AG
Published
2021-01-12
Volume
21
Issue
2
Pages
479
ISSN
1424-8220
Cited by
42
References
10
Language
en
Funders
  • Ministerio de Economía, Industria y Competitividad, Gobierno de España (DPI2016-78831-C2-1-R)
  • Agencia Estatal de Investigación (PID2019-107722RB-C21)
  • European Commission (FEDER funds)
  • Universitat Politècnica de València (PAID-06-18)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.