Stromal Thickness in the Normal Cornea: Three-dimensional Display With Artemis Very High-Frequency Digital Ultrasound
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
Purpose: To characterize the stromal thickness profile in a population of normal eyes. Methods: Stromal thickness profile was measured in vivo by Artemis very high-frequency digital ultrasound scanning (ArcScan, Morrison, Colo) across the central 10-mm corneal diameter on 110 normal eyes. Maps of the average, standard deviation, minimum, maximum, and range of stromal thickness were plotted. The average location of the thinnest stroma was found. The cross-sectional hemi-meridional stromal thickness profile was calculated using annular averaging. The absolute stromal thickness progression relative to the thinnest point was calculated using annular averaging as well as for 8 hemi-meridians individually. Results: The mean stromal thickness at the corneal vertex and at the thinnest point were 465.4±36.9 µ m and 461.8±37.3 µ m, respectively. The thinnest stroma was displaced on average 0.17±0.31 mm inferiorly and 0.33±0.40 mm temporally from the corneal vertex. The average absolute stromal thickness progression from the thinnest point could be described by the quadratic equation: stromal thickness = 6.411 × radius 2 + 2.444 × radius (R 2 = 0.999). Absolute stromal thickness progression was independent of stromal thickness at the thinnest point. The increase in hemi-meridional absolute stromal thickness progression was greatest superiorly and lowest temporally. Conclusions: Three-dimensional thickness mapping of the corneal stroma and stromal thickness progression in a population of normal eyes represent a normative data set, which may help in early diagnosis of corneal abnormalities such as keratoconus and pellucid marginal degeneration. Absolute stromal thickness progression was found to be independent of stromal thickness. [ J Refract Surg . 2009;25:776–786.]
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Three-dimensional ultrasound imaging
Fenster, A., Downey, D. B., & Cardinal, H. N. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/5/201 · Cited by 812
Worthen, D. M. (1972) · Archives of Ophthalmology · doi:10.1001/archopht.1972.01000030236034 · Cited by 798
Analysis of blink rate patterns in normal subjects
Bentivoglio, A. R., Bressman, S. B., Cassetta, E., Carretta, D., Tonali, P., & Albanese, A. (1997) · Movement Disorders · doi:10.1002/mds.870120629 · Cited by 512
Changes in Collagen Orientation and Distribution in Keratoconus Corneas
Meek, K. M., Tuft, S. J., Huang, Y., Gill, P. S., Hayes, S., Newton, R. H., & Bron, A. J. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-1253 · Cited by 509
Ambrósio, R., Alonso, R. S., Luz, A., & Coca Velarde, L. G. (2006) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2006.06.025 · Cited by 451
Interaction of Eyelids and Tears in Corneal Wetting and the Dynamics of the Normal Human Eyeblink
Doane, M. G. (1980) · American Journal of Ophthalmology · doi:10.1016/0002-9394(80)90058-6 · Cited by 433
Reinstein, D. Z., Archer, T. J., Gobbe, M., Silverman, R. H., & Coleman, D. J. (2008) · Journal of Refractive Surgery · doi:10.3928/1081597x-20080601-05 · Cited by 379
Self-citationEpithelial and corneal thickness measurements by in vivo confocal microscopy through focusing (CMTF)
Li, H. F., Petroll, W. M., Møller‐Pedersen, T., Maurer, J. K., Cavanagh, H. D., & Jester, J. V. (1997) · Current Eye Research · doi:10.1076/ceyr.16.3.214.15412 · Cited by 356
Cell Production and Migration in the Epithelial Layer of the Cornea
HANNA, C., & O'BRIEN, J. E. (1960) · Archives of Ophthalmology · doi:10.1001/archopht.1960.01840010538009 · Cited by 328
Patel, S. V., McLaren, J. W., Hodge, D. O., & Bourne, W. M. (2001) · PubMed · Cited by 286
Refractive Index of the Human Corneal Epithelium and Stroma
Patel, S., Marshall, J., & Fitzke, F. W. (1995) · Journal of Refractive Surgery · doi:10.3928/1081-597x-19950301-09 · Cited by 284
X-Ray Scattering Used to Map the Preferred Collagen Orientation in the Human Cornea and Limbus
Aghamohammadzadeh, H., Newton, R. H., & Meek, K. M. (2004) · Structure · doi:10.1016/j.str.2004.01.002 · Cited by 233
Confocal microscopic characterization of wound repair after photorefractive keratectomy.
Møller–Pedersen, T., Li, H. F., Petroll, W. M., Cavanagh, H. D., & Jester, J. V. (1998) · PubMed · Cited by 230
Møller-Pedersen, T., Vogel, M., Li, H. F., Petroll, W. M., Cavanagh, H. D., & Jester, J. V. (1997) · Ophthalmology · doi:10.1016/s0161-6420(97)30307-8 · Cited by 209
Reinstein, D. Z., Silverman, R. H., Raevsky, T., Simoni, G. J., Lloyd, H. O., Najafi, D. J., Rondeau, M. J., & Coleman, D. J. (2000) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20000701-04 · Cited by 203
Self-citationConfocal microscopy in vivo in corneas of long-term contact lens wearers.
Patel, S. V., McLaren, J. W., Hodge, D. O., & Bourne, W. M. (2002) · PubMed · Cited by 188
Reinstein, D. Z., Silverman, R. H., Sutton, H. F. S., & Coleman, D. J. (1999) · Ophthalmology · doi:10.1016/s0161-6420(99)90105-7 · Cited by 183
Self-citationEpithelial and Corneal Thickness Measurements by High-frequency Ultrasound Digital Signal Processing
Reinstein, D. Z., Silverman, R. H., Rondeau, M. J., & Coleman, D. J. (1994) · Ophthalmology · doi:10.1016/s0161-6420(94)31373-x · Cited by 169
Self-citationLadage, P. M., Yamamoto, K., Ren, D. H., Li, L., Jester, J. V., Petroll, W. M., & Cavanagh, H. D. (2001) · Ophthalmology · doi:10.1016/s0161-6420(01)00639-x · Cited by 161
Wang, J., Fonn, D., SIMPSON, T. L., Sorbara, L., Kort, R., & Jones, L. (2003) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.03-0239 · Cited by 151
Spadea, L., Fasciani, R., Necozione, S., & Balestrazzi, E. (2000) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20000301-05 · Cited by 151
Effect of myopic laser in situ keratomileusis on epithelial and stromal thickness
Erie, J. C., Patel, S. V., McLaren, J. W., Ramirez, M., Hodge, D. O., Maguire, L. J., & Bourne, W. M. (2002) · Ophthalmology · doi:10.1016/s0161-6420(02)01106-5 · Cited by 150
Corneal Pachymetric Topography
Reinstein, D. Z., Silverman, R. H., Trokel, S. L., & Coleman, D. J. (1994) · Ophthalmology · doi:10.1016/s0161-6420(94)31314-5 · Cited by 149
Self-citationHaque, S., Fonn, D., SIMPSON, T. L., & Jones, L. (2004) · Eye & Contact Lens Science & Clinical Practice · doi:10.1097/01.icl.0000140223.60892.16 · Cited by 130
O'Brart, D. P. S., Lohmann, C. P., Klonos, G., Corbett, M. C., Pollock, W. S. T., Muir, M. K., & Marshall, J. (1994) · Ophthalmology · doi:10.1016/s0161-6420(94)38032-8 · Cited by 124
Role of epithelial hyperplasia in regression following photorefractive keratectomy.
Gauthier, C. A., Holden, B. A., Epstein, D., Tengroth, B., Fagerholm, P., & Hamberg‐Nyström, H. (1996) · British Journal of Ophthalmology · doi:10.1136/bjo.80.6.545 · Cited by 118
Wang, J., Thomas, J., Cox, I., & Rollins, A. M. (2004) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.03-1088 · Cited by 111
Wang, J., Fonn, D., & SIMPSON, T. L. (2001) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2001.tb03609.x · Cited by 102
Optics of the Corneal Epithelium
Simon, G., Ren, Q., Kervick, G. N., & Parel, J.-M. A. (1993) · Journal of Refractive Surgery · doi:10.3928/1081-597x-19930101-10 · Cited by 94
Regression and epithelial hyperplasia after myopic photorefractive keratectomy in a human cornea
Lohmann, C. P., Reischl, U., & Marshall, J. (1999) · Journal of Cataract & Refractive Surgery · doi:10.1016/s0886-3350(99)00014-0 · Cited by 89
Corneal Epithelial Thinning Profile Induced by Long-Term Wear of Hydrogel Lenses
Pérez, J. G., González‐Méijome, J. M., Jalbert, I., Sweeney, D. F., & Erickson, P. A. (2003) · Cornea · doi:10.1097/00003226-200305000-00005 · Cited by 87
High-Frequency Ultrasound Measurement of the Thickness of the Corneal Epithelium
Reinstein, D. Z., Silverman, R. H., & Coleman, D. J. (1993) · Journal of Refractive Surgery · doi:10.3928/1081-597x-19930901-12 · Cited by 86
Self-citationIn Vivo Laser Confocal Microscopy of Bowman’s Layer of the Cornea
Kobayashi, A., Yokogawa, H., & Sugiyama, K. (2006) · Ophthalmology · doi:10.1016/j.ophtha.2006.05.058 · Cited by 86
Ultrasound characterization of normal ocular tissue in the frequency range from 50 MHz to 100 MHz
Ye, S. G., Harasiewicz, K. A., Pavlin, C. J., & Foster, F. S. (1995) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.368319 · Cited by 82
Avitabile, T., Marano, F., Uva, M. G., & REIBALDI, A. (1997) · Cornea · doi:10.1097/00003226-199711000-00007 · Cited by 74
Comparison of Human Central Cornea and Limbus in Vivo Using Optical Coherence Tomography
Feng, Y., & SIMPSON, T. L. (2005) · Optometry and Vision Science · doi:10.1097/01.opx.0000162649.97059.72 · Cited by 71
Epithelial Alterations Following Photorefractive Keratectomy for Myopia
Gauthier, C. A., Epstein, D., Holden, B. A., Tengroth, B., Fagerholm, P., Hamberg‐Nyström, H., & Sievert, R. (1995) · Journal of Refractive Surgery · doi:10.3928/1081-597x-19950301-11 · Cited by 63
Clinical Evaluation of Factors Influencing Toric Soft Contact Lens Fit
Young, G. P., Hunt, C., & COVEY, M. (2002) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2002.tb01403.x · Cited by 62
Avitabile, T., Marano, F., Uva, M. G., & REIBALDI, A. (1997) · PubMed · Cited by 62
Wirbelauer, C., & Pham, D. T. (2004) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2004.01.035 · Cited by 60
Histological and immunohistochemical findings after laser in situ keratomileusis in human corneas
Philipp, W., Speicher, L., & Göttinger, W. (2003) · Journal of Cataract & Refractive Surgery · doi:10.1016/s0886-3350(02)01611-5 · Cited by 58
Central and Peripheral Corneal Thickness in Keratoconus and Normal Patient Groups
Gromacki, S. J., & Barr, J. T. (1994) · Optometry and Vision Science · doi:10.1002/j.1538-9235.1994.tb03378.x · Cited by 57
Reinstein, D. Z., Ameline, B., Puech, M., Montefiore, G., & Laroche, L. (2005) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20050901-10 · Cited by 36
Self-citation
Research works printed but not linked: 14
- 10.1016/j.jcrs.2006.07.016 · doi:10.1016/j.jcrs.2006.07.016
- 10.3928/1081-597X-20061101-04 · doi:10.3928/1081-597x-20061101-04
- 10.1001/archopht.1969.00990020184006 · doi:10.1001/archopht.1969.00990020184006
- 10.1016/S0161-6420(99)00022-6 · doi:10.1016/s0161-6420(99)00022-6
- 10.1016/S0886-3350(02)01275-0 · doi:10.1016/s0886-3350(02)01275-0
- 10.1016/S0161-6420(98)93211-0 · doi:10.1016/s0161-6420(98)93211-0
- 10.1016/j.jcrs.2006.08.020 · doi:10.1016/j.jcrs.2006.08.020
- 10.3928/1081-597X-20010501-04 · doi:10.3928/1081-597x-20010501-04
- 10.1097/00003226-199211000-00012 · doi:10.1097/00003226-199211000-00012
- Reinstein DZ, Archer TJ, Gobbe M. Exclusion of keratoconus initially diagnosed by Orbscan using epithelial and stromal layer thickness mapping. Presented at: American Academy of Ophthalmology Annual Meeting; November 11–14, 2006; Las Vegas, Nev.
- 10.5962/bhl.title.160281 · doi:10.5962/bhl.title.160281
- 10.1097/01.ico.0000127486.78424.6e · doi:10.1097/01.ico.0000127486.78424.6e
- 10.1097/00006324-199407000-00003 · doi:10.1097/00006324-199407000-00003
- 10.3928/1081597X-20090422-07 · DOI
Cited by
Corneal structure and transparency
Meek, K. M., & Knupp, C. (2015) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.07.001 · Cited by 853
Blackburn, B. J., Jenkins, M. W., Rollins, A. M., & Dupps, W. J. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00066 · Cited by 167
Keeping an Eye on Decellularized Corneas: A Review of Methods, Characterization and Applications
Wilson, S., Sidney, L., Dunphy, S., Rose, J., & Hopkinson, A. (2013) · Journal of Functional Biomaterials · doi:10.3390/jfb4030114 · Cited by 100
“The technique has been utilized in many areas concerning corneal tissue including: quantitative assessment and analysis of corneal epithelial thickness; pathology in response to chronic exposure to various drugs [135]; measurement of the depth of incisions following radial keratoctotomy [133]; and most importantly and…”
MethodUltraviolet light transmission through the human corneal stroma is reduced in the periphery
Doutch, J. J., Quantock, A. J., Joyce, N. C., & Meek, K. M. (2012) · Biophysical Journal · doi:10.1016/j.bpj.2012.02.023 · Cited by 50
Mallet, J. D., Dorr, M. M., Drigeard Desgarnier, M.-C., Bastien, N., Gendron, S. P., & Rochette, P. J. (2016) · PLoS ONE · doi:10.1371/journal.pone.0162212 · Cited by 40
Metadata
- Authors
- Reinstein, D. Z., Archer, T. J., Gobbe, M., Silverman, R. H., & Coleman, D. J.
- Venue
- Journal of Refractive Surgery
- Publisher
- SLACK, Inc.
- Published
- 2009-09
- Volume
- 25
- Issue
- 9
- Pages
- 776-786
- ISSN
- 1042-962X (ISSN-L)
- 1081-597X
- OpenAlex
- W2083655341
- Cited by
- 299
- References
- 43
- FWCI
- 13.86
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.