Application of spectroscopic methods for monitoring of bioprocesses and the implications for the manufacture of biologics
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
The ability to monitor and control bioreactor processes is an integral component to the implementation of Process Analytical Technology and Quality by Design principles. Desirable attributes of monitoring methods include the ability to monitor multiple analytes in real time with little to no sample processing. Spectroscopic methods fit these criteria and significant advancements in their application have been made. However, implementation of these systems has been hampered by their complexity. Here, we present an overview of near IR, mid-IR, Raman and fluorescence spectroscopy technologies, and the steps taken to enable their implementation as effective bioprocess monitoring tools. Specific applications for monitoring of microbial and mammalian cell bioreactors, and screening and classification of raw materials are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reference database of Raman spectra of biological molecules
De Gelder, J., De Gussem, K., Vandenabeele, P., & Moens, L. (2007) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1734 · Cited by 1,425
Abu‐Absi, N. R., Kenty, B. M., Cuellar, M. E., Borys, M. C., Sakhamuri, S., Strachan, D. J., Hausladen, M. C., & Li, Z. J. (2011) · Biotechnology and Bioengineering · doi:10.1002/bit.23023 · Cited by 322
Self-citationBioreactor monitoring with spectroscopy and chemometrics: a review
Lourenço, N. D., Lopes, J. A., Almeida, C. F., Sarraguça, M. C., & Pinheiro, H. M. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6073-9 · Cited by 275
Whelan, J., Craven, S., & Glennon, B. (2012) · Biotechnology Progress · doi:10.1002/btpr.1590 · Cited by 159
Optical sensor systems for bioprocess monitoring
Ulber, R., Frerichs, J.-G., & Beutel, S. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-1930-1 · Cited by 151
On-line infrared spectroscopy for bioprocess monitoring
Landgrebe, D., Haake, C., Höpfner, T., Beutel, S., Hitzmann, B., Scheper, T., Rhiel, M., & Reardon, K. F. (2010) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-010-2743-8 · Cited by 134
Near Infrared Spectroscopy for Bioprocess Monitoring and Control: Current Status and Future Trends
Scarff, M., Arnold, S. A., Harvey, L. M., & McNeil, B. (2006) · Critical Reviews in Biotechnology · doi:10.1080/07388550500513677 · Cited by 124
Shaw, A. D., Kaderbhai, N., Jones, A., Woodward, A. M., Goodacre, R., Rowland, J. J., & Kell, D. B. (1999) · Applied Spectroscopy · doi:10.1366/0003702991945777 · Cited by 84
On‐line monitoring of Phaffia rhodozyma fed‐batch process with in situ dispersive raman spectroscopy
Cannizzaro, C., Rhiel, M., Marison, I., & von Stockar, U. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10698 · Cited by 70
Li, C., & Li, T. (2009) · Current Pharmaceutical Biotechnology · doi:10.2174/138920109788488950 · Cited by 35
Cited by
Esmonde-White, K. A., Cuellar, M., Uerpmann, C., Lenain, B., & Lewis, I. R. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-9824-1 · Cited by 332
“Spectroscopic sensors are sometimes called Bsoft sensors^ in the bioprocessing literature because spectroscopic data is modeled in software programs and the models provide information akin to hardware sensors [87, 88].”
BackgroundDigital Twins in Pharmaceutical and Biopharmaceutical Manufacturing: A Literature Review
Chen, Y., Yang, O., Sampat, C., Bhalode, P., Ramachandran, R., & Ierapetritou, M. (2020) · Processes · doi:10.3390/pr8091088 · Cited by 278
Sensor systems for bioprocess monitoring
Biechele, P., Busse, C., Solle, D., Scheper, T., & Reardon, K. (2015) · Engineering in Life Sciences · doi:10.1002/elsc.201500014 · Cited by 224
“The use of Raman spectroscopy is limited by the strong fluorescence activity of several biological molecules in the culture broth [142].”
BackgroundRafferty, C., Johnson, K., O'Mahony, J., Burgoyne, B., Rea, R., & Balss, K. M. (2020) · Biotechnology Progress · doi:10.1002/btpr.2977 · Cited by 63
Toward Biotherapeutic Product Real‐Time Quality Monitoring
Guerra, A., von Stosch, M., & Glassey, J. (2019) · Critical Reviews in Biotechnology · doi:10.1080/07388551.2018.1524362 · Cited by 58
“[30–32] or multiplexed [33,34] automated sampling systems are usually coupled with real-time multi-parameter flow cytometry or spectroscopic monitoring techniques [24,28,35,36].”
BackgroundBaradez, M.-O., Biziato, D., Hassan, E., & Marshall, D. (2018) · Frontiers in Medicine · doi:10.3389/fmed.2018.00047 · Cited by 55
Kozma, B., Hirsch, E., Gergely, S., Párta, L., Pataki, H., & Salgó, A. (2017) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2017.06.070 · Cited by 41
Pais, D. A. M., Portela, R. M. C., Carrondo, M. J. T., Isidro, I. A., & Alves, P. M. (2019) · Biotechnology and Bioengineering · doi:10.1002/bit.27117 · Cited by 36
Matthews, T. E., Smelko, J. P., Berry, B., Romero‐Torres, S., Hill, D., Kshirsagar, R., & Wiltberger, K. (2018) · Biotechnology Progress · doi:10.1002/btpr.2711 · Cited by 34
Santos, R. M., Kaiser, P., Menezes, J. C., & Peinado, A. (2019) · Talanta · doi:10.1016/j.talanta.2019.02.088 · Cited by 33
In‐Line Monitoring of Protein Concentration With MIR Spectroscopy During UFDF
Milewska, A., Baekelandt, G., Boutaieb, S., Mozin, V., & Falconbridge, A. (2023) · Engineering in Life Sciences · doi:10.1002/elsc.202200050 · Cited by 18
Metadata
- Authors
- Abu-Absi, N. R., Martel, R. P., Lanza, A. M., Clements, S. J., Borys, M. C., & Li, Z. J.
- Venue
- Pharmaceutical Bioprocessing
- Publisher
- OMICS Publishing Group
- Published
- 2014-06
- Volume
- 2
- Issue
- 3
- Pages
- 267-284
- ISSN
- 2048-9145 (ISSN-L)
- 2048-9153
- OpenAlex
- W2073927666
- Cited by
- 47
- References
- 10
- FWCI
- 2.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.