Individual and Combined Effects of Age, Breast Density, and Hormone Replacement Therapy Use on the Accuracy of Screening Mammography
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The relationships among breast density, age, and use of hormone replacement therapy (HRT) in breast cancer detection have not been fully evaluated. OBJECTIVE: To determine how breast density, age, and use of HRT individually and in combination affect the accuracy of screening mammography. DESIGN: Prospective cohort study. SETTING: 7 population-based mammography registries in North Carolina; New Mexico; New Hampshire; Vermont; Colorado; Seattle, Washington; and San Francisco, California. PARTICIPANTS: 329 495 women 40 to 89 years of age who had 463 372 screening mammograms from 1996 to 1998; 2223 women received a diagnosis of breast cancer. MEASUREMENTS: Breast density, age, HRT use, rate of breast cancer occurrence, and sensitivity and specificity of screening mammography. RESULTS: Adjusted sensitivity ranged from 62.9% in women with extremely dense breasts to 87.0% in women with almost entirely fatty breasts; adjusted sensitivity increased with age from 68.6% in women 40 to 44 years of age to 83.3% in women 80 to 89 years of age. Adjusted specificity increased from 89.1% in women with extremely dense breasts to 96.9% in women with almost entirely fatty breasts. In women who did not use HRT, adjusted specificity increased from 91.4% in women 40 to 44 years of age to 94.4% in women 80 to 89 years of age. In women who used HRT, adjusted specificity was about 91.7% for all ages. CONCLUSIONS: Mammographic breast density and age are important predictors of the accuracy of screening mammography. Although HRT use is not an independent predictor of accuracy, it probably affects accuracy by increasing breast density.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hulley, S. (1998) · JAMA · doi:10.1001/jama.280.7.605 · Cited by 6,216
Guide to Clinical Preventive Services
Wesley Allen, T. (1991) · The Journal of the American Osteopathic Association · doi:10.1515/jom-1991-900515 · Cited by 2,129
Boyd, N. F., Byng, J. W., Jong, R. A., Fishell, E. K., Little, L. E., Miller, A. B., Lockwood, G. A., Tritchler, D. L., & Yaffe, M. J. (1995) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/87.9.670 · Cited by 1,105
Mandelson, M. T. (2000) · Journal of the National Cancer Institute · doi:10.1093/jnci/92.13.1081 · Cited by 1,031
Mammographic densities and breast cancer risk.
Boyd, N. F., Lockwood, G. A., Byng, J. W., Tritchler, D., & Yaffe, M. J. (1998) · PubMed · Cited by 915
A Meta-analysis of the Effect of Estrogen Replacement Therapy on the Risk of Breast Cancer
Steinberg, K. K. (1991) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1991.03460150089030 · Cited by 626
Effect of Age, Breast Density, and Family History on the Sensitivity of First Screening Mammography
Kerlikowske, K. (1996) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1996.03540010035027 · Cited by 624
Self-citationEfficacy of breast cancer screening by age. New results swedish two-county trial
Tabar, L., Fagerberg, G., Chen, H.-H., Duffy, S. W., Smart, C. R., Gad, A., & Smith, R. A. (1995) · Cancer · doi:10.1002/1097-0142(19950515)75:10<2507::aid-cncr2820751017>3.0.co;2-h · Cited by 557
Rosenberg, R. D., Hunt, W. C., Williamson, M. R., Gilliland, F. D., Wiest, P. W., Kelsey, C. A., Key, C. R., & Linver, M. N. (1998) · Radiology · doi:10.1148/radiology.209.2.9807581 · Cited by 364
Self-citationEffect of Estrogen Replacement Therapy on the Specificity and Sensitivity of Screening Mammography
Laya, M. B., Larson, E. B., Taplin, S. H., & White, E. (1996) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/88.10.643 · Cited by 243
Self-citation
Cited by
Screening for breast cancer: U.S. Preventive Services Task Force recommendation statement
Siu, A. L., & on behalf of the U.S. Preventive Services Task Force (2016) · Annals of Internal Medicine · doi:10.7326/m15-2886 · Cited by 2,094
“A BCSC study of more than 300 000 women found that sensitivity decreased from 87% in the lowest density category to 63% in the highest, and specificity decreased from 96% to 90% as breast density increased (16).”
BackgroundDiagnostic Performance of Digital versus Film Mammography for Breast-Cancer Screening
Pisano, E. D., Gatsonis, C., Hendrick, E., Yaffe, M., Baum, J. K., Acharyya, S., Conant, E. F., Fajardo, L. L., Bassett, L., D'Orsi, C., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa052911 · Cited by 1,940
Chlebowski, R. T., Hendrix, S. L., Langer, R. D., Stefanick, M. L., Gass, M., Lane, D., Rodabough, R. J., Gilligan, M. A., Cyr, M. G., Thomson, C. A., et al. (2003) · JAMA · doi:10.1001/jama.289.24.3243 · Cited by 1,872
Screening for Breast Cancer: U.S. Preventive Services Task Force Recommendation Statement
U.S. Preventive Services Task Force* (2009) · Annals of Internal Medicine · doi:10.7326/0003-4819-151-10-200911170-00008 · Cited by 1,686
Berg, W. A., Gutierrez, L., NessAiver, M. S., Carter, W. B., Bhargavan, M., Lewis, R. S., & Ioffe, O. B. (2004) · Radiology · doi:10.1148/radiol.2333031484 · Cited by 1,439
Pepe, M. S. (2004) · American Journal of Epidemiology · doi:10.1093/aje/kwh101 · Cited by 1,276
“For example, higher breast density makes mammographic readings less accurate (21).”
BackgroundElmore, J. G. (2005) · JAMA · doi:10.1001/jama.293.10.1245 · Cited by 1,075
Breast Cancer Screening and Diagnosis
Bevers, T. B., Anderson, B. O., Bonaccio, E., Buys, S., Daly, M. B., Dempsey, P. J., Farrar, W. B., Fleming, I., Garber, J. E., Harris, R. E., et al. (2009) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2009.0070 · Cited by 465
Pisano, E. D., Hendrick, R. E., Yaffe, M. J., Baum, J. K., Acharyya, S., Cormack, J. B., Hanna, L. A., Conant, E. F., Fajardo, L. L., Bassett, L. W., et al. (2008) · Radiology · doi:10.1148/radiol.2461070200 · Cited by 464
Cerussi, A., Shah, N., Hsiang, D., Durkin, A., Butler, J., & Tromberg, B. J. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2337546 · Cited by 421
Hubbard, R. A., Kerlikowske, K., Flowers, C. I., Yankaskas, B. C., Zhu, W., & Miglioretti, D. L. (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00004 · Cited by 414
Self-citationPrevalence of Mammographically Dense Breasts in the United States
Sprague, B. L., Gangnon, R. E., Burt, V., Trentham-Dietz, A., Hampton, J. M., Wellman, R. D., Kerlikowske, K., & Miglioretti, D. L. (2014) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/dju255 · Cited by 400
Self-citationEffects of Age on the Detection and Management of Breast Cancer
McGuire, A., Brown, J., Malone, C., McLaughlin, R., & Kerin, M. (2015) · Cancers · doi:10.3390/cancers7020815 · Cited by 374
Contrast-enhanced Mammography: State of the Art
Jochelson, M. S., & Lobbes, M. B. I. (2021) · Radiology · doi:10.1148/radiol.2021201948 · Cited by 352
Supplemental Breast MR Imaging Screening of Women with Average Risk of Breast Cancer
Kuhl, C. K., Strobel, K., Bieling, H., Leutner, C., Schild, H. H., & Schrading, S. (2017) · Radiology · doi:10.1148/radiol.2016161444 · Cited by 350
Andersson, I., Ikeda, D. M., Zackrisson, S., Ruschin, M., Svahn, T., Timberg, P., & Tingberg, A. (2008) · European Radiology · doi:10.1007/s00330-008-1076-9 · Cited by 343
Implementation of Breast Tomosynthesis in a Routine Screening Practice: An Observational Study
Rose, S. L., Tidwell, A. L., Bujnoch, L. J., Kushwaha, A. C., Nordmann, A. S., & Sexton, R. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9672 · Cited by 329
Schousboe, J. T., Kerlikowske, K., Loh, A., & Cummings, S. R. (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-1-201107050-00003 · Cited by 317
Self-citationComparison of Screening Mammography in the United States and the United Kingdom
Smith-Bindman, R. (2003) · JAMA · doi:10.1001/jama.290.16.2129 · Cited by 314
Photoacoustic angiography of the breast
Kruger, R. A., Lam, R. B., Reinecke, D. R., Del Rio, S. P., & Doyle, R. P. (2010) · Medical Physics · doi:10.1118/1.3497677 · Cited by 302
Electromagnetic Breast Imaging: Results of a Pilot Study in Women with Abnormal Mammograms
Poplack, S. P., Tosteson, T. D., Wells, W. A., Pogue, B. W., Meaney, P. M., Hartov, A., Kogel, C. A., Soho, S. K., Gibson, J. J., & Paulsen, K. D. (2007) · Radiology · doi:10.1148/radiol.2432060286 · Cited by 299
Mammographic Breast Density Assessment Using Deep Learning: Clinical Implementation
Lehman, C. D., Yala, A., Schuster, T., Dontchos, B., Bahl, M., Swanson, K., & Barzilay, R. (2019) · Radiology · doi:10.1148/radiol.2018180694 · Cited by 294
Identifying Women With Dense Breasts at High Risk for Interval Cancer: A Cohort Study
Kerlikowske, K., Zhu, W., Tosteson, A. N. A., Sprague, B. L., Tice, J. A., Lehman, C. D., Miglioretti, D. L., & for the Breast Cancer Surveillance Consortium* (2015) · Annals of Internal Medicine · doi:10.7326/m14-1465 · Cited by 286
Self-citationKerlikowske, K., Hubbard, R. A., Miglioretti, D. L., Geller, B. M., Yankaskas, B. C., Lehman, C. D., Taplin, S. H., Sickles, E. A., & for the Breast Cancer Surveillance Consortium (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00005 · Cited by 268
Self-citationElmore, J. G., Jackson, S. L., Abraham, L., Miglioretti, D. L., Carney, P. A., Geller, B. M., Yankaskas, B. C., Kerlikowske, K., Onega, T., Rosenberg, R. D., et al. (2009) · Radiology · doi:10.1148/radiol.2533082308 · Cited by 263
Self-citationScreening for Breast Cancer in 2018—What Should We be Doing Today?
Seely, J. M., & Alhassan, T. (2018) · Current Oncology · doi:10.3747/co.25.3770 · Cited by 258
McTiernan, A., Martin, C. F., Peck, J. D., Aragaki, A. K., Chlebowski, R. T., Pisano, E. D., Wang, C. Y., Brunner, R. L., Johnson, K. C., Manson, J. E., et al. (2005) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/dji279 · Cited by 254
Tice, J. A., Cummings, S. R., Ziv, E., & Kerlikowske, K. (2005) · Breast Cancer Research and Treatment · doi:10.1007/s10549-005-5152-4 · Cited by 245
“Breast density is reported with mammography interpretation primarily to indicate the possibility of reduced sensitivity to detect cancer in women with dense breasts [18,19].”
BackgroundSelf-citationScreening Mammography in Older Women: A Review
Walter, L. C., & Schonberg, M. A. (2014) · JAMA · doi:10.1001/jama.2014.2834 · Cited by 241
Lobbes, M. B. I., Prevos, R., Smidt, M., Tjan-Heijnen, V. C. G., van Goethem, M., Schipper, R., Beets-Tan, R. G., & Wildberger, J. E. (2013) · Insights into Imaging · doi:10.1007/s13244-013-0219-y · Cited by 237
“In addition, the diagnostic accuracy of mammography is strongly dependent on breast density, being lower in breasts with extremely dense fibroglandular tissue [50].”
BackgroundMammographic density. Measurement of mammographic density
Yaffe, M. J. (2008) · Breast Cancer Research · doi:10.1186/bcr2102 · Cited by 235
Armstrong, K., Moye, E., Williams, S., Berlin, J. A., & Reynolds, E. E. (2007) · Annals of Internal Medicine · doi:10.7326/0003-4819-146-7-200704030-00008 · Cited by 235
Niell, B. L., Freer, P. E., Weinfurtner, R. J., Arleo, E. K., & Drukteinis, J. S. (2017) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2017.06.004 · Cited by 226
Sprague, B. L., Stout, N. K., Schechter, C., van Ravesteyn, N. T., Cevik, M., Alagoz, O., Lee, C. I., van den Broek, J. J., Miglioretti, D. L., Mandelblatt, J. S., et al. (2015) · Annals of Internal Medicine · doi:10.7326/m14-0692 · Cited by 217
“The false-negative rate of screening mammography varies as much as 10-fold from the lowest to the highest categories of breast density (5).”
BackgroundSelf-citationBreast density implications and supplemental screening
Vourtsis, A., & Berg, W. A. (2019) · European Radiology · doi:10.1007/s00330-018-5668-8 · Cited by 217
Accuracy of Screening Mammography Interpretation by Characteristics of Radiologists
Barlow, W. E., Chi, C., Carney, P. A., Taplin, S. H., D'Orsi, C., Cutter, G., Hendrick, R. E., & Elmore, J. G. (2004) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djh333 · Cited by 216
Self-citationLobbes, M. B. I., Lalji, U., Houwers, J., Nijssen, E. C., Nelemans, P. J., van Roozendaal, L., Smidt, M. L., Heuts, E., & Wildberger, J. E. (2014) · European Radiology · doi:10.1007/s00330-014-3154-5 · Cited by 210
“However, even though the diagnostic accuracy of full field digital mammography (FFDM) is good, it depends heavily on breast density [1, 2].”
Outcomes of Screening Mammography by Frequency, Breast Density, and Postmenopausal Hormone Therapy
Kerlikowske, K., Zhu, W., Hubbard, R. A., Geller, B., Dittus, K., Braithwaite, D., Wernli, K. J., Miglioretti, D. L., O’Meara, E. S., & Breast Cancer Surveillance Consortium, F. T. (2013) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2013.307 · Cited by 209
“Prior studies report that postmenopausal combination HT increases the risk of abnormal mammography.(10,26) We found that for women aged 50 to 74 years with average or high breast density, receiving combination HT increases the cumulative probability of receiving at least 1 false-positive mammography result after 10 ye…”
BackgroundSelf-citationSprague, B. L., Conant, E. F., Onega, T., Garcia, M. P., Beaber, E. F., Herschorn, S. D., Lehman, C. D., Tosteson, A. N. A., Lacson, R., Schnall, M. D., et al. (2016) · Annals of Internal Medicine · doi:10.7326/m15-2934 · Cited by 202
“M breast density impairs mammography performance and is also an independent risk factor for breast cancer (1, 2).”
BackgroundGilbert, F. J., Tucker, L., Gillan, M. G., Willsher, P., Cooke, J., Duncan, K. A., Michell, M. J., Dobson, H. M., Lim, Y. Y., Purushothaman, H., et al. (2015) · Health Technology Assessment · doi:10.3310/hta19040 · Cited by 195
“Detected by Number of cancers (%) Number of DCIS cases (%) 2D 2D+DBT Synthetic 2D + DBT No No No 33 (3) 6 (3) No No Yes 16 (1) 4 (2) No Yes No 18 (2) 2 (1) No Yes Yes 75 (7) 14 (7) Yes No No 24 (2) 8 (4) Yes No Yes 45 (4) 8 (4) Yes Yes No 61 (6) 15 (8) Yes Yes Yes 840 (75) 143 (71) Total 1112 200”
MethodInfluentialKodahl, A. R., Lyng, M. B., Binder, H., Cold, S., Gravgaard, K., Knoop, A. S., & Ditzel, H. J. (2014) · Molecular Oncology · doi:10.1016/j.molonc.2014.03.002 · Cited by 189
Sorin, V., Yagil, Y., Yosepovich, A., Shalmon, A., Gotlieb, M., Neiman, O. H., & Sklair-Levy, M. (2018) · American Journal of Roentgenology · doi:10.2214/ajr.17.19355 · Cited by 181
Gilbert, F. J., Tucker, L., Gillan, M. G. C., Willsher, P., Cooke, J., Duncan, K. A., Michell, M. J., Dobson, H. M., Lim, Y. Y., Suaris, T., et al. (2015) · Radiology · doi:10.1148/radiol.2015142566 · Cited by 178
Miglioretti, D. L., Lange, J., van den Broek, J. J., Lee, C. I., van Ravesteyn, N. T., Ritley, D., Kerlikowske, K., Fenton, J. J., Melnikow, J., de Koning, H. J., et al. (2016) · Annals of Internal Medicine · doi:10.7326/m15-1241 · Cited by 171
Self-citationEffectiveness of Computer-Aided Detection in Community Mammography Practice
Fenton, J. J., Abraham, L., Taplin, S. H., Geller, B. M., Carney, P. A., D'Orsi, C., Elmore, J. G., Barlow, W. E., & for the Breast Cancer Surveillance Consortium (2011) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djr206 · Cited by 168
“We included patient variables associated with interpretive accuracy including age, breast density, and time since previous mammogram (27,28).”
MethodSelf-citationAssessing Dynamic Breast Cancer Screening Policies
Maillart, L. M., Ivy, J. S., Ransom, S., & Diehl, K. (2008) · Operations Research · doi:10.1287/opre.1080.0614 · Cited by 163
Knijnenburg, T. A., Klau, G. W., Iorio, F., Garnett, M. J., McDermott, U., Shmulevich, I., & Wessels, L. F. A. (2016) · Scientific Reports · doi:10.1038/srep36812 · Cited by 74
Hsu, J. C., Naha, P. C., Lau, K. C., Chhour, P., Hastings, R., Moon, B. F., Stein, J. M., Witschey, W. R. T., McDonald, E. S., Maidment, A. D. A., et al. (2018) · Nanoscale · doi:10.1039/c8nr03741h · Cited by 63
“The sensitivity decreases from a level of 87% in women with less dense breasts to only 30-62% in women with dense breasts.(3-4) When mammography is used alone as a screening tool, decreased sensitivity may lead to delayed diagnosis, more advanced stage and reduced survival.”
Background
Metadata
- Authors
- Carney, P. A., Miglioretti, D. L., Yankaskas, B. C., Kerlikowske, K., Rosenberg, R., Rutter, C. M., Geller, B. M., Abraham, L. A., Taplin, S. H., Dignan, M., Cutter, G., & Ballard-Barbash, R.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2003-02-04
- Volume
- 138
- Issue
- 3
- Pages
- 168-175
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2158732932
- Cited by
- 1,142
- References
- 16
- FWCI
- 29.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.