Sources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Open accessThe DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Studies of diagnostic accuracy are subject to different sources of bias and variation than studies that evaluate the effectiveness of an intervention. Little is known about the effects of these sources of bias and variation. PURPOSE: To summarize the evidence on factors that can lead to bias or variation in the results of diagnostic accuracy studies. DATA SOURCES: MEDLINE, EMBASE, and BIOSIS, and the methodologic databases of the Centre for Reviews and Dissemination and the Cochrane Collaboration. Methodologic experts in diagnostic tests were contacted. STUDY SELECTION: Studies that investigated the effects of bias and variation on measures of test performance were eligible for inclusion, which was assessed by one reviewer and checked by a second reviewer. Discrepancies were resolved through discussion. DATA EXTRACTION: Data extraction was conducted by one reviewer and checked by a second reviewer. DATA SYNTHESIS: The best-documented effects of bias and variation were found for demographic features, disease prevalence and severity, partial verification bias, clinical review bias, and observer and instrument variation. For other sources, such as distorted selection of participants, absent or inappropriate reference standard, differential verification bias, and review bias, the amount of evidence was limited. Evidence was lacking for other features, including incorporation bias, treatment paradox, arbitrary choice of threshold value, and dropouts. CONCLUSIONS: Many issues in the design and conduct of diagnostic accuracy studies can lead to bias or variation; however, the empirical evidence about the size and effect of these issues is limited.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861
Problems of Spectrum and Bias in Evaluating the Efficacy of Diagnostic Tests
Ransohoff, D. F., & Feinstein, A. R. (1978) · New England Journal of Medicine · doi:10.1056/nejm197810262991705 · Cited by 1,734
The STARD Statement for Reporting Studies of Diagnostic Accuracy: Explanation and Elaboration
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Moher, D., Rennie, D., de Vet, H. C. W., & Lijmer, J. G. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00012-w1 · Cited by 1,124
Self-citationClinical Epidemiology: The Architecture of Clinical Research.
(1985) · Annals of Internal Medicine · doi:10.7326/0003-4819-103-4-649_2 · Cited by 949
NHLBI funding policies. Enhancing stability, predictability, and cost control.
Lenfant, C. (1994) · Circulation · doi:10.1161/01.cir.90.1.1 · Cited by 762
Assessment of diagnostic tests when disease verification is subject to selection bias
Begg, C. B., & Greenes, R. A. (1983) · Biometrics · doi:10.2307/2530820 · Cited by 708
Variability in Radiologists' Interpretations of Mammograms
Elmore, J. G., Wells, C. K., Lee, C. H., Howard, D. H., & Feinstein, A. R. (1994) · New England Journal of Medicine · doi:10.1056/nejm199412013312206 · Cited by 601
Levy, D., Labib, S. B., Anderson, K. M., Christiansen, J. C., Kannel, W. B., & Castelli, W. P. (1990) · Circulation · doi:10.1161/01.cir.81.3.815 · Cited by 531
Development and validation of methods for assessing the quality of diagnostic accuracy studies
Whiting, P., Rutjes, A., Dinnes, J., Reitsma, J., Bossuyt, P., & Kleijnen, J. (2004) · Health Technology Assessment · doi:10.3310/hta8250 · Cited by 372
Self-citationFactors affecting sensitivity and specificity of exercise electrocardiography
Hlatky, M. A., Pryor, D. B., Harrell, F. E., Califf, R. M., Mark, D. B., & Rosati, R. A. (1984) · The American Journal of Medicine · doi:10.1016/0002-9343(84)90437-6 · Cited by 371
Cited by
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationReitsma, J. B., Glas, A. S., Rutjes, A. W. S., Scholten, R. J. P. M., Bossuyt, P. M., & Zwinderman, A. H. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.02.022 · Cited by 3,369
“Second, our understanding of how sources of bias and variability can affect estimates of diagnostic accuracy is largely based on thesemeasures [27,28].”
BackgroundSelf-citationSystematic reviews: CRD's guidance for undertaking reviews in health care
Tacconelli, E. (2010) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(10)70065-7 · Cited by 3,245
STARD 2015 guidelines for reporting diagnostic accuracy studies: explanation and elaboration
Cohen, J. F., Korevaar, D. A., Altman, D. G., Bruns, D. E., Gatsonis, C. A., Hooft, L., Irwig, L., Levine, D., Reitsma, J. B., de Vet, H. C. W., et al. (2016) · BMJ Open · doi:10.1136/bmjopen-2016-012799 · Cited by 2,570
Self-citationMoons, K. G. M., de Groot, J. A. H., Bouwmeester, W., Vergouwe, Y., Mallett, S., Altman, D. G., Reitsma, J. B., & Collins, G. S. (2014) · PLoS Medicine · doi:10.1371/journal.pmed.1001744 · Cited by 2,018
“, blinded to) the results of the index tests is well established [35,40,54,69,79,80,85].”
BackgroundSelf-citationPolyp Miss Rate Determined by Tandem Colonoscopy: A Systematic Review
van Rijn, J. C., Reitsma, J. B., Stoker, J., Bossuyt, P. M., van Deventer, S. J., & Dekker, E. (2006) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2006.00390.x · Cited by 1,344
Self-citationGilbody, S., Richards, D., Brealey, S., & Hewitt, C. (2007) · Journal of General Internal Medicine · doi:10.1007/s11606-007-0333-y · Cited by 1,290
Procalcitonin as a diagnostic marker for sepsis: A systematic review and meta-analysis.
Wacker, C., Prkno, A., Brunkhorst, F. M., & Schlattmann, P. (2013) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(12)70323-7 · Cited by 1,198
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationLin, J. S., Bowles, E. J. A., Williams, S. B., & Morrison, C. C. (2017) · JAMA · doi:10.1001/jama.2017.0562 · Cited by 1,082
Receiver operating characteristic (ROC) curve for medical researchers
Kumar, R., & Indrayan, A. (2011) · Indian Pediatrics · doi:10.1007/s13312-011-0055-4 · Cited by 872
Whitlock, E. P., Lin, J. S., Liles, E., Beil, T. L., & Fu, R. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-9-200811040-00245 · Cited by 845
The use of receiver operating characteristic curves in biomedical informatics
Lasko, T. A., Bhagwat, J. G., Zou, K. H., & Ohno-Machado, L. (2005) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2005.02.008 · Cited by 823
A unification of models for meta-analysis of diagnostic accuracy studies
Harbord, R. M., Deeks, J. J., Egger, M., Whiting, P., & Sterne, J. A. C. (2007) · Biostatistics · doi:10.1093/biostatistics/kxl004 · Cited by 751
Self-citationEndpoints and clinical trial design for nonalcoholic steatohepatitis
Sanyal, A. J., Brunt, E. M., Kleiner, D. E., Kowdley, K. V., Chalasani, N., Lavine, J. E., Ratziu, V., & McCullough, A. (2011) · Hepatology · doi:10.1002/hep.24376 · Cited by 750
Uzzan, B., Cohen, R., Nicolas, P., Cucherat, M., & Perret, G.-Y. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000226413.54364.36 · Cited by 738
Lin, J. S., Perdue, L. A., Henrikson, N. B., Bean, S. I., & Blasi, P. R. (2021) · JAMA · doi:10.1001/jama.2021.4417 · Cited by 650
Evidence of bias and variation in diagnostic accuracy studies
Rutjes, A. W. S., Reitsma, J. B., Di Nisio, M., Smidt, N., van Rijn, J. C., & Bossuyt, P. M. M. (2006) · Canadian Medical Association Journal · doi:10.1503/cmaj.050090 · Cited by 611
Self-citationQUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W., Westwood, M. E., Mallett, S. V., Deeks, J. J., Reitsma, J. B., Leeflang, M., Sterne, J. A. C., & Bossuyt, P. M. (2011) · Data Archiving and Networked Services (DANS) · doi:10.1059/0003-4819-155-8-201110180-00009 · Cited by 601
Self-citationScreening tests: a review with examples
Maxim, L. D., Niebo, R., & Utell, M. J. (2014) · Inhalation Toxicology · doi:10.3109/08958378.2014.955932 · Cited by 562
The diagnostic accuracy of the PTSD Checklist: A critical review
McDonald, S. D., & Calhoun, P. S. (2010) · Clinical Psychology Review · doi:10.1016/j.cpr.2010.06.012 · Cited by 546
Evaluation of diagnostic tests when there is no gold standard. A review of methods
Rutjes, A., Reitsma, J., Coomarasamy, A., Khan, K., & Bossuyt, P. (2007) · Health Technology Assessment · doi:10.3310/hta11500 · Cited by 524
Self-citationCase–Control and Two-Gate Designs in Diagnostic Accuracy Studies
Rutjes, A. W., Reitsma, J. B., Vandenbroucke, J. P., Glas, A. S., & Bossuyt, P. M. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.048595 · Cited by 501
Self-citationDiagnostic test accuracy may vary with prevalence: implications for evidence-based diagnosis
Leeflang, M. M. G., Bossuyt, P. M. M., & Irwig, L. (2009) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2008.04.007 · Cited by 482
Self-citationDiagnostic accuracy of D‐dimer test for exclusion of venous thromboembolism: a systematic review
DI NISIO, M., SQUIZZATO, A., RUTJES, A. W. S., BÜLLER, H. R., ZWINDERMAN, A. H., & BOSSUYT, P. M. M. (2007) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2007.02328.x · Cited by 465
Self-citationDegos, F., Perez, P., Roche, B., Mahmoudi, A., Asselineau, J., Voitot, H., & Bedossa, P. (2010) · Journal of Hepatology · doi:10.1016/j.jhep.2010.05.035 · Cited by 435
Lin, J. S., O’Connor, E., Rossom, R. C., Perdue, L. A., & Eckstrom, E. (2013) · Annals of Internal Medicine · doi:10.7326/0003-4819-159-9-201311050-00730 · Cited by 410
Reitsma, J. B., Rutjes, A. W. S., Khan, K. S., Coomarasamy, A., & Bossuyt, P. M. (2009) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2009.02.005 · Cited by 405
“In both situations there is a likely increase in agreement between index test results and reference standard outcome; these biases are known as incorporation and diagnostic review bias [8,11].”
BackgroundMethodSelf-citationDiagnostic Precision of Fecal Calprotectin for Inflammatory Bowel Disease and Colorectal Malignancy
von Roon, A. C., Karamountzos, L., Purkayastha, S., Reese, G. E., Darzi, A. W., Teare, J. P., Paraskeva, P., & Tekkis, P. P. (2007) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2007.01126.x · Cited by 401
Chou, R., Ballantyne, J. C., Fanciullo, G. J., Fine, P. G., & Miaskowski, C. (2009) · The Journal of Pain · doi:10.1016/j.jpain.2008.10.007 · Cited by 383
Chou, R., Fanciullo, G. J., Fine, P. G., Miaskowski, C., Passik, S. D., & Portenoy, R. K. (2009) · The Journal of Pain · doi:10.1016/j.jpain.2008.10.009 · Cited by 366
Ensuring quality and access for malaria diagnosis: how can it be achieved?
Bell, D., Wongsrichanalai, C., & Barnwell, J. W. (2006) · Nature Reviews Microbiology · doi:10.1038/nrmicro1474 · Cited by 354
No role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citationHewitt, C., Gilbody, S., Brealey, S., Paulden, M., Palmer, S., Mann, R., Green, J., Morrell, J., Barkham, M., Light, K., et al. (2009) · Health Technology Assessment · doi:10.3310/hta13360 · Cited by 330
Sica, G. T. (2006) · Radiology · doi:10.1148/radiol.2383041109 · Cited by 331
Kim, K. W., Lee, J., Choi, S. H., Huh, J., & Park, S. H. (2015) · Korean Journal of Radiology · doi:10.3348/kjr.2015.16.6.1175 · Cited by 329
Dewey, M., Zimmermann, E., Deissenrieder, F., Laule, M., Dübel, H.-P., Schlattmann, P., Knebel, F., Rutsch, W., & Hamm, B. (2009) · Circulation · doi:10.1161/circulationaha.109.859280 · Cited by 328
Pewsner, D., Jüni, P., Egger, M., Battaglia, M., Sundström, J., & Bachmann, L. M. (2007) · BMJ · doi:10.1136/bmj.39276.636354.ae · Cited by 328
Ozen, S., Marks, S. D., Brogan, P., Groot, N., de Graeff, N., Avcin, T., Bader-Meunier, B., Dolezalova, P., Feldman, B. M., Kone-Paut, I., et al. (2019) · Rheumatology · doi:10.1093/rheumatology/kez041 · Cited by 327
Roy, J.-S., Braën, C., Leblond, J., Desmeules, F., Dionne, C. E., MacDermid, J. C., Bureau, N. J., & Frémont, P. (2015) · British Journal of Sports Medicine · doi:10.1136/bjsports-2014-094148 · Cited by 319
Davey, E., Barratt, A., Irwig, L., Chan, S. F., Macaskill, P., Mannes, P., & Saville, A. M. (2006) · The Lancet · doi:10.1016/s0140-6736(06)67961-0 · Cited by 318
Does This Patient Have Dementia?
Holsinger, T., Deveau, J., Boustani, M., & Williams, J. W. (2007) · JAMA · doi:10.1001/jama.297.21.2391 · Cited by 305
Jahromi, A. S., Cinà, C. S., Liu, Y., & Clase, C. M. (2005) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2005.02.044 · Cited by 303
A Meta-analysis of Clinical Screening Tests for Obstructive Sleep Apnea
Ramachandran, S. K., & Josephs, L. A. (2009) · Anesthesiology · doi:10.1097/aln.0b013e31819c47b6 · Cited by 297
Cochrane diagnostic test accuracy reviews
Leeflang, M. M., Deeks, J. J., Takwoingi, Y., & Macaskill, P. (2013) · Systematic Reviews · doi:10.1186/2046-4053-2-82 · Cited by 292
A systematic review classifies sources of bias and variation in diagnostic test accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., & Mallett, S. (2013) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2013.05.014 · Cited by 283
Self-citationMao, R., Xiao, Y.-L., Gao, X., Chen, B.-L., He, Y., Yang, L., Hu, P.-J., & Chen, M.-H. (2012) · Inflammatory Bowel Diseases · doi:10.1002/ibd.22861 · Cited by 280
Recht, M. P., Dewey, M., Dreyer, K., Langlotz, C., Niessen, W., Prainsack, B., & Smith, J. J. (2020) · European Radiology · doi:10.1007/s00330-020-06672-5 · Cited by 268
Cook, D. A., Brydges, R., Zendejas, B., Hamstra, S. J., & Hatala, R. (2013) · Academic Medicine · doi:10.1097/acm.0b013e31828ffdcf · Cited by 267
Virgili, G., Menchini, F., Casazza, G., Hogg, R., Das, R. R., Wang, X., & Michelessi, M. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008081.pub3 · Cited by 265
Diagnostic methods I: sensitivity, specificity, and other measures of accuracy
van Stralen, K. J., Stel, V. S., Reitsma, J. B., Dekker, F. W., Zoccali, C., & Jager, K. J. (2009) · Kidney International · doi:10.1038/ki.2009.92 · Cited by 264
Self-citationForkus, S. R., Raudales, A. M., Rafiuddin, H. S., Weiss, N. H., Messman, B. A., & Contractor, A. A. (2023) · Clinical Psychology: Science and Practice · doi:10.1037/cps0000111 · Cited by 262
Conde-Agudelo, A., Romero, R., Hassan, S. S., & Yeo, L. (2010) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2010.02.064 · Cited by 256
Diagnostic criteria for atopic dermatitis: a systematic review
Brenninkmeijer, E. E. A., Schram, M. E., Leeflang, M. M. G., Bos, J. D., & Spuls, P. I. (2008) · British Journal of Dermatology · doi:10.1111/j.1365-2133.2007.08412.x · Cited by 256
Lo, K., Wong, M., Khalechelvam, P., & Tam, W. (2016) · Obesity Reviews · doi:10.1111/obr.12456 · Cited by 254
Terasawa, T., Lau, J., Bardet, S., Couturier, O., Hotta, T., Hutchings, M., Nihashi, T., & Nagai, H. (2009) · Journal of Clinical Oncology · doi:10.1200/jco.2008.16.0861 · Cited by 254
Ziswiler, H., Reichenbach, S., Vögelin, E., Bachmann, L. M., Villiger, P. M., & Jüni, P. (2005) · Arthritis & Rheumatism · doi:10.1002/art.20723 · Cited by 245
Understanding the Direction of Bias in Studies of Diagnostic Test Accuracy
Kohn, M. A., Carpenter, C. R., & Newman, T. B. (2013) · Academic Emergency Medicine · doi:10.1111/acem.12255 · Cited by 241
Poynard, T., Halfon, P., Castera, L., Munteanu, M., Imbert-Bismut, F., Ratziu, V., Benhamou, Y., Bourliere, M., de Ledinghen, V., & FibroPaca Group (2007) · Clinical Chemistry · doi:10.1373/clinchem.2007.085795 · Cited by 239
“Single center (0) (26) (29) (20) (25) (0.”
Steingart, K. R., Henry, M., Laal, S., Hopewell, P. C., Ramsay, A., Menzies, D., Cunningham, J., Weldingh, K., & Pai, M. (2007) · PLoS Medicine · doi:10.1371/journal.pmed.0040202 · Cited by 238
“We included studies from endemic countries that used sputum smear microscopy, a test with modest sensitivity (up to 70%–80%), as the reference standard; use of an insensitive reference standard may have led to biased estimates of commercial test accuracy [65].”
The quality of diagnostic accuracy studies since the STARD statement: Has it improved?
Smidt, N., Rutjes, A. W. S., van der Windt, D. A. W. M., Ostelo, R. W. J. G., Bossuyt, P. M., Reitsma, J. B., Bouter, L. M., & de Vet, H. C. W. (2006) · Neurology · doi:10.1212/01.wnl.0000238386.41398.30 · Cited by 235
“where data were collected 35 (28) 30 (21) 0.”
Self-citationValidity of the Manchester Triage System in emergency care: A prospective observational study
Zachariasse, J. M., Seiger, N., Rood, P. P. M., Alves, C. F., Freitas, P., Smit, F. J., Roukema, G. R., & Moll, H. A. (2017) · PLOS ONE · doi:10.1371/journal.pone.0170811 · Cited by 228
Umemneku Chikere, C. M., Wilson, K., Graziadio, S., Vale, L., & Allen, A. J. (2019) · PLOS ONE · doi:10.1371/journal.pone.0223832 · Cited by 220
Deep multimodal fusion of image and non-image data in disease diagnosis and prognosis: a review
Cui, C., Yang, H., Wang, Y., Zhao, S., Asad, Z., Coburn, L. A., Wilson, K. T., Landman, B. A., & Huo, Y. (2023) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/acc2fe · Cited by 218
“However, such decision-making procedures can be subjective, qualitative, and exhibit large inter-subject variabilities [4, 5].”
Harbord, R. M., Whiting, P., Sterne, J. A. C., Egger, M., Deeks, J. J., Shang, A., & Bachmann, L. M. (2008) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2007.09.013 · Cited by 217
Self-citationMeta-Analysis of Diagnostic and Screening Test Accuracy Evaluations: Methodologic Primer
Gatsonis, C., & Paliwal, P. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.06.0226 · Cited by 215
“Two developments in the diagnostic area are the Standards for Reporting of Diagnostic Accuracy (STARD) checklist for reporting of studies of diagnostic accuracy [4, 13, 14] and the quality assessment tool for diagnostic accuracy (QUADAS) for assessing the quality of studies of diagnostic accuracy [12, 15].”
MethodLombardi, G., Crescioli, G., Cavedo, E., Lucenteforte, E., Casazza, G., Bellatorre, A.-G., Lista, C., Costantino, G., Frisoni, G., Virgili, G., et al. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd009628.pub2 · Cited by 214
Jellema, P., van der Windt, D. A. W. M., Bruinvels, D. J., Mallen, C. D., van Weyenberg, S. J. B., Mulder, C. J., & de Vet, H. C. W. (2010) · BMJ · doi:10.1136/bmj.c1269 · Cited by 208
Morris, R. K., Quinlan‐Jones, E., Kilby, M. D., & Khan, K. S. (2007) · Prenatal Diagnosis · doi:10.1002/pd.1810 · Cited by 197
Ruling a diagnosis in or out with “SpPIn” and “SnNOut”: a note of caution
Pewsner, D., Battaglia, M., Minder, C., Marx, A., Bucher, H. C., & Egger, M. (2004) · BMJ · doi:10.1136/bmj.329.7459.209 · Cited by 196
Performance of Purified Antigens for Serodiagnosis of Pulmonary Tuberculosis: a Meta-Analysis
Steingart, K. R., Dendukuri, N., Henry, M., Schiller, I., Nahid, P., Hopewell, P. C., Ramsay, A., Pai, M., & Laal, S. (2009) · Clinical and Vaccine Immunology · doi:10.1128/cvi.00355-08 · Cited by 191
“The use of an insensitive reference standard may have led to biased estimates of antigen performance (111).”
BackgroundResultThe Gold Standard Paradox in Digital Image Analysis: Manual Versus Automated Scoring as Ground Truth
Aeffner, F., Wilson, K., Martin, N. T., Black, J. C., Hendriks, C. L. L., Bolon, B., Rudmann, D. G., Gianani, R., Koegler, S. R., Krueger, J., et al. (2017) · Archives of Pathology & Laboratory Medicine · doi:10.5858/arpa.2016-0386-ra · Cited by 190
Empirical evidence of the importance of comparative studies of diagnostic test accuracy
Takwoingi, Y., Leeflang, M. M. G., & Deeks, J. J. (2013) · Annals of Internal Medicine · doi:10.7326/0003-4819-158-7-201304020-00006 · Cited by 187
Haase, R., Schlattmann, P., Gueret, P., Andreini, D., Pontone, G., Alkadhi, H., Hausleiter, J., Garcia, M. J., Leschka, S., Meijboom, W. B., et al. (2019) · BMJ · doi:10.1136/bmj.l1945 · Cited by 184
Ensuring quality and access for malaria diagnosis: how can it be achieved?
Bell, D., Wongsrichanalai, C., & Barnwell, J. W. (2006) · Nature Reviews Microbiology · doi:10.1038/nrmicro1525 · Cited by 184
DI NISIO, M., VAN SLUIS, G. L., BOSSUYT, P. M. M., BÜLLER, H. R., PORRECA, E., & RUTJES, A. W. S. (2010) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2010.03771.x · Cited by 183
Self-citationDo Online Information Retrieval Systems Help Experienced Clinicians Answer Clinical Questions?
Westbrook, J. I. (2005) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1717 · Cited by 181
“Performance in formulating and answering clinical questions is also likely to depend on contextual information 18,19 not available within the short scenarios used in the current study.”
BackgroundOptimization of the Cutoff Value for the Aspergillus Double-Sandwich Enzyme Immunoassay
Maertens, J. A., Klont, R., Masson, C., Theunissen, K., Meersseman, W., Lagrou, K., Heinen, C., Crepin, B., Eldere, J. V., Tabouret, M., et al. (2007) · Clinical Infectious Diseases · doi:10.1086/514349 · Cited by 179
The International Caries Detection and Assessment System – ICDAS: A Systematic Review
Ekstrand, K. R., Gimenez, T., Ferreira, F. R., Mendes, F. M., & Braga, M. M. (2018) · Caries Research · doi:10.1159/000486429 · Cited by 179
Challenges in Systematic Reviews of Diagnostic Technologies
Tatsioni, A., Zarin, D. A., Aronson, N., Samson, D. J., Flamm, C. R., Schmid, C., & Lau, J. (2005) · Annals of Internal Medicine · doi:10.7326/0003-4819-142-12_part_2-200506211-00004 · Cited by 176
“The lack of consistent relationships between specific quality elements and the magnitude of outcomes complicates the task of assessing quality (27, 28).”
BackgroundMethodSchuetz, G. M., Schlattmann, P., & Dewey, M. (2012) · BMJ · doi:10.1136/bmj.e6717 · Cited by 176
de Graeff, N., Groot, N., Ozen, S., Eleftheriou, D., Avcin, T., Bader-Meunier, B., Dolezalova, P., Feldman, B. M., Kone-Paut, I., Lahdenne, P., et al. (2019) · Rheumatology · doi:10.1093/rheumatology/key344 · Cited by 176
Hebert, J. J., Koppenhaver, S. L., Parent, E. C., & Fritz, J. M. (2009) · Spine · doi:10.1097/brs.0b013e3181ae625c · Cited by 171
Burch, J. A., Soares-Weiser, K., St John, D. J. B., Duffy, S., Smith, S., Kleijnen, J., & Westwood, M. (2007) · Journal of Medical Screening · doi:10.1258/096914107782066220 · Cited by 170
Self-citationManchikanti, L. (2009) · Pain Physician · doi:10.36076/ppj.2009/12/819 · Cited by 168
van Trijffel, E., Anderegg, Q., Bossuyt, P. M. M., & Lucas, C. (2005) · Manual Therapy · doi:10.1016/j.math.2005.04.008 · Cited by 167
“In diagnostic accuracy studies, availability of clinical information from participants to examiners before executing the test has been shown to increase sensitivity (Whiting et al., 2004).”
BackgroundMethodSelf-citationVAN DIJK, N., BOER, K. R., COLMAN, N., BAKKER, A., STAM, J., VAN GRIEKEN, J. J. M., WILDE, A. A. M., LINZER, M., REITSMA, J. B., & WIELING, W. (2008) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00984.x · Cited by 164
Self-citationMorris, R., Malin, G., Khan, K., & Kilby, M. (2009) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2009.02194.x · Cited by 163
Wang, S.-H., Tang, C., Sun, J., Yang, J., Huang, C., Phillips, P., & Zhang, Y.-D. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00818 · Cited by 158
“set error rate may tend to overestimate the test error rate for the model fit on the entire data set (Bylander, 2002; Whiting et al., 2004).”
BackgroundA proposed framework for developing quality assessment tools
Whiting, P., Wolff, R., Mallett, S., Simera, I., & Savović, J. (2017) · Systematic Reviews · doi:10.1186/s13643-017-0604-6 · Cited by 121
“This is the approach we took for the original QUADAS tool [7] and also the updated QUADAS-2 [8, 17, 18].”
MethodSelf-citationDerivation and Validation of a Simple Perioperative Sleep Apnea Prediction Score
Ramachandran, S. K., Kheterpal, S., Consens, F., Shanks, A., Doherty, T. M., Morris, M., & Tremper, K. K. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181d489b0 · Cited by 117
“rather than in a typical clinical population.(13) The prevalence of OSA as defined by AHI 5 in the STOP study was 73% in the derivation group and 69% in the validation group,(12,14) similar to most clinical screening test studies for OSA that are based on sleep laboratories.”
BackgroundMethodResultInfluentialGlucose challenge test for detecting gestational diabetes mellitus: a systematic review
van Leeuwen, M., Louwerse, M., Opmeer, B., Limpens, J., Serlie, M., Reitsma, J., & Mol, B. (2012) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2011.03254.x · Cited by 110
Self-citationSøreide, K., Kørner, H., & Søreide, J. A. (2011) · Annals of Surgery · doi:10.1097/sla.0b013e318204a892 · Cited by 109
Decision-analytic modeling to evaluate benefits and harms of medical tests: uses and limitations
Trikalinos, T. A., Siebert, U., & Lau, J. (2009) · Medical Decision Making · doi:10.1177/0272989x09345022 · Cited by 88
Tran, V.-T., Gartlehner, G., Yaacoub, S., Boutron, I., Schwingshackl, L., Stadelmaier, J., Sommer, I., Alebouyeh, F., Afach, S., Meerpohl, J., et al. (2024) · Annals of Internal Medicine · doi:10.7326/m23-3389 · Cited by 66
“…(Sommer et al, 2023 [24]), we had to add instructions to exclude studies assessing effectiveness of drugs on post-COVID-19 disease and/or assessing postexposure prophylaxis, which were not explicitly excluded in the PICOS criteria of the review, but did not fit with the objective of the review.”
MethodArmijo-Olivo, S., Fuentes, J., Ospina, M., Saltaji, H., & Hartling, L. (2013) · BMC Medical Research Methodology · doi:10.1186/1471-2288-13-116 · Cited by 60
“Difficulties in classifying items as potentially linked to bias have been acknowledged in previous studies that analyzed bias in different types of research designs [25,28,65].”
BackgroundResultChapter 9: Options for Summarizing Medical Test Performance in the Absence of a “Gold Standard”
Trikalinos, T. A., & Balion, C. M. (2012) · Journal of General Internal Medicine · doi:10.1007/s11606-012-2031-7 · Cited by 59
Lefebvre, C., Glanville, J., Beale, S., Boachie, C., Duffy, S., Fraser, C., Harbour, J., McCool, R., & Smith, L. (2017) · Health Technology Assessment · doi:10.3310/hta21690 · Cited by 49
Ban, J.-W., Emparanza, J. I., Urreta, I., & Burls, A. (2016) · PLOS ONE · doi:10.1371/journal.pone.0145779 · Cited by 18
Metadata
- Authors
- Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2004-02-03
- Volume
- 140
- Issue
- 3
- Pages
- 189-202
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2088323328
- Cited by
- 798
- References
- 60
- FWCI
- 53.36
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.