Measuring Blood Pressure for Decision Making and Quality Reporting: Where and How Many Measures?
The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The optimal setting and number of blood pressure (BP) measurements that should be used for clinical decision making and quality reporting are uncertain. OBJECTIVE: To compare strategies for home or clinic BP measurement and their effect on classifying patients as having BP that was in or out of control. DESIGN: Secondary analysis of a randomized, controlled trial of strategies to improve hypertension management. (ClinicalTrials.gov registration number: NCT00237692) SETTING: Primary care clinics affiliated with the Durham Veterans Affairs Medical Center. PATIENTS: 444 veterans with hypertension followed for 18 months. MEASUREMENTS: Blood pressure was measured repeatedly by using 3 methods: standardized research BP measurements at 6-month intervals; clinic BP measurements obtained during outpatient visits; and home BP measurements using a monitor that transmitted measurements electronically. RESULTS: Patients provided 111,181 systolic BP (SBP) measurements (3218 research, 7121 clinic, and 100,842 home measurements) over 18 months. Systolic BP control rates at baseline (mean SBP<140 mm Hg for clinic or research measurement; <135 mm Hg for home measurement) varied substantially, with 28% classified as in control by clinic measurement, 47% by home measurement, and 68% by research measurement. Short-term variability was large and similar across all 3 methods of measurement, with a mean within-patient coefficient of variation of 10% (range, 1% to 24%). Patients could not be classified as having BP that was in or out of control with 80% certainty on the basis of a single clinic SBP measurement from 120 mm Hg to 157 mm Hg. The effect of within-patient variability could be greatly reduced by averaging several measurements, with most benefit accrued at 5 to 6 measurements. LIMITATION: The sample was mostly men with a long-standing history of hypertension and was selected on the basis of previous poor BP control. CONCLUSION: Physicians who want to have 80% or more certainty that they are correctly classifying patients' BP control should use the average of several measurements. Hypertension quality metrics based on a single clinic measurement potentially misclassify a large proportion of patients. PRIMARY FUNDING SOURCE: U.S. Department of Veterans Affairs Health Services Research and Development Service.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chobanian, A. V. (2003) · JAMA · doi:10.1001/jama.289.19.2560 · Cited by 25,386
Blood pressure, stroke, and coronary heart disease
Collins, R., Peto, R., MacMahon, S., Godwin, J., Qizilbash, N., Collins, R., MacMahon, S., Hebert, P., Eberlein, K. A., Taylor, J. O., et al. (1990) · The Lancet · doi:10.1016/0140-6736(90)90944-z · Cited by 4,491
Effects of intensive blood-pressure control in type 2 diabetes mellitus
(2010) · New England Journal of Medicine · doi:10.1056/nejmoa1001286 · Cited by 3,598
Rothwell, P. M., Howard, S. C., Dolan, E., O'Brien, E., Dobson, J. E., Dahlöf, B., Sever, P. S., & Poulter, N. R. (2010) · The Lancet · doi:10.1016/s0140-6736(10)60308-x · Cited by 1,784
Systolic versus diastolic blood pressure and risk of coronary heart disease
Kannel, W. B., Gordon, T., & Schwartz, M. J. (1971) · The American Journal of Cardiology · doi:10.1016/0002-9149(71)90428-0 · Cited by 925
Bobrie, G. (2004) · JAMA · doi:10.1001/jama.291.11.1342 · Cited by 842
Parati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837
Casas, J. P., Chua, W., Loukogeorgakis, S., Vallance, P., Smeeth, L., Hingorani, A. D., & MacAllister, R. J. (2005) · The Lancet · doi:10.1016/s0140-6736(05)67814-2 · Cited by 745
Rothwell, P. M. (2010) · The Lancet · doi:10.1016/s0140-6736(10)60309-1 · Cited by 702 · cited 1×
“This study considered only the underlying mean SBP, but other components of BP independently predict risk, including diastolic BP, maximum SBP, BP variability (40, 44), morning BP surge (45), and nocturnal BP (46); yet, their role in decision making is less well-defined and requires further exploration.”
BackgroundPickering, T. G., Miller, N. H., Ogedegbe, G., Krakoff, L. R., Artinian, N. T., & Goff, D. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.189010 · Cited by 668
Principles and Techniques of Blood Pressure Measurement
Ogedegbe, G., & Pickering, T. (2010) · Cardiology Clinics · doi:10.1016/j.ccl.2010.07.006 · Cited by 554
Verdecchia, P., Staessen, J. A., Angeli, F., de Simone, G., Achilli, A., Ganau, A., Mureddu, G., Pede, S., Maggioni, A. P., Lucci, D., et al. (2009) · The Lancet · doi:10.1016/s0140-6736(09)61340-4 · Cited by 434
A RANDOM-ZERO SPHYGMOMANOMETER
Weight, B. M., & Dore, C. F. (1970) · The Lancet · doi:10.1016/s0140-6736(70)90709-9 · Cited by 319
Ogden, L. G., He, J., Lydick, E., & Whelton, P. K. (2000) · Hypertension · doi:10.1161/01.hyp.35.2.539 · Cited by 302
Pickering, T. G., Miller, N. H., Ogedegbe, G., Krakoff, L. R., Artinian, N. T., & Goff, D. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.189011 · Cited by 294 · cited 3×
“Recent position statements from the American Society of Hypertension and the European Society of Hypertension have called for greater use and reimbursement for home BP monitoring in the management of known or suspected hypertension, with a recommendation for 12 or more home readings for making clinical decisions (31,…”
BackgroundResultStaessen, J. A. (2004) · JAMA · doi:10.1001/jama.291.8.955 · Cited by 288
Prognostic Value of the Morning Blood Pressure Surge in 5645 Subjects From 8 Populations
Li, Y., Thijs, L., Hansen, T. W., Kikuya, M., Boggia, J., Richart, T., Metoki, H., Ohkubo, T., Torp-Pedersen, C., Kuznetsova, T., et al. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.137273 · Cited by 275
Stergiou, G. S., Baibas, N. M., Gantzarou, A. P., Skeva, I. I., Kalkana, C. B., Roussias, L. G., & Mountokalakis, T. D. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(01)02324-x · Cited by 268 · cited 1×
“When properly calibrated, home BP monitors can provide inexpensive, accurate, and reproducible readings (24).”
BackgroundMeasuring Blood Pressure Accurately: New and Persistent Challenges
Jones, D. W., Appel, L. J., Sheps, S. G., Roccella, E. J., & Lenfant, C. (2003) · JAMA · doi:10.1001/jama.289.8.1027 · Cited by 264
Home Blood Pressure Measurement
Verberk, W. J., Kroon, A. A., Kessels, A. G. H., & de Leeuw, P. W. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.05.058 · Cited by 212 · cited 1×
“However, estimates of the upper limit of normal home SBP have ranged from 125 mm Hg to 140 mm Hg (29).”
BackgroundSystolic pressure is all that matters
Williams, B., Lindholm, L. H., & Sever, P. (2008) · The Lancet · doi:10.1016/s0140-6736(08)60804-1 · Cited by 199 · cited 1×
“It is widely believed that the harmful effects of elevated BP are primarily attributable to a person’s average daily (or true) BP (6–8), with particular emphasis given to systolic BP (SBP) (9, 10).”
BackgroundHead, G. A., Mihailidou, A. S., Duggan, K. A., Beilin, L. J., Berry, N., Brown, M. A., Bune, A. J., Cowley, D., Chalmers, J. P., Howe, P. R. C., et al. (2010) · BMJ · doi:10.1136/bmj.c1104 · Cited by 185
Kerr, E. A., Zikmund-Fisher, B. J., Klamerus, M. L., Subramanian, U., Hogan, M. M., & Hofer, T. P. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-148-10-200805200-00004 · Cited by 175 · cited 2×
“Providers cite uncertainty about the patient’s true BP on the basis of clinic measurements as a common reason for not changing therapy (33); our data suggest that this concern is wellfounded.”
BackgroundVerberk, W. J., Kroon, A. A., Lenders, J. W. M., Kessels, A. G. H., van Montfrans, G. A., Smit, A. J., van der Kuy, P.-H. M., Nelemans, P. J., Rennenberg, R. J. M. W., Grobbee, D. E., et al. (2007) · Hypertension · doi:10.1161/hypertensionaha.107.094193 · Cited by 172
Blood pressure measurement and detection of hypertension
PICKERING, P. (1994) · The Lancet · doi:10.1016/s0140-6736(94)91053-7 · Cited by 149 · cited 1×
“Furthermore, although any home or clinic BP measurement approximates the patient’s true BP, it is also subject to short-term biological fluctuations and measurement error, which together result in substantial short-term variability of observed BP (17).”
BackgroundPickering, T. G., Miller, N. H., Ogedegbe, G., Krakoff, L. R., Artinian, N. T., & Goff, D. (2008) · The Journal of Clinical Hypertension · doi:10.1111/j.1751-7176.2008.08418.x · Cited by 127
Bosworth, H. B., Olsen, M. K., McCant, F., Harrelson, M., Gentry, P., Rose, C., Goldstein, M. K., Hoffman, B. B., Powers, B. J., & Oddone, E. Ž. (2007) · American Heart Journal · doi:10.1016/j.ahj.2007.03.004 · Cited by 127 · cited 1×
“org), and a detailed study protocol is presented elsewhere (34).”
BackgroundSelf-citationReliability of Self-reported Blood Pressure Measurements
Johnson, K. A., Partsch, D. J., Rippole, L. L., & McVey, D. M. (1999) · Archives of Internal Medicine · doi:10.1001/archinte.159.22.2689 · Cited by 126
Principles and techniques of blood pressure measurement
Pickering, T. G. (2002) · Cardiology Clinics · doi:10.1016/s0733-8651(01)00009-1 · Cited by 125
Monitoring Cholesterol Levels: Measurement Error or True Change?
Glasziou, P. P., Irwig, L., Heritier, S., Simes, R. J., Tonkin, A., & for the LIPID Study Investigators (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-148-9-200805060-00005 · Cited by 122
Imai, Y., Ohkubo, T., Hozawa, A., Tsuji, I., Matsubara, M., Araki, T., Chonan, K., Kikuya, M., Satoh, H., Hisamichi, S., et al. (2001) · Journal of Hypertension · doi:10.1097/00004872-200102000-00003 · Cited by 103
Evaluation of the Technique Used by Health-Care Workers for Taking Blood Pressure
Villegas, I., Arias, I. C., Botero, A., & Escobar, A. (1995) · Hypertension · doi:10.1161/01.hyp.26.6.1204 · Cited by 102
Epidemiologic Assessment of the Role of Blood Pressure in Stroke
Lassen, N. A. (1996) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1996.03540150081041 · Cited by 98
Feasibility Study of N-of-1 Trials With Blood Pressure Self-Monitoring in Hypertension
Chatellier, G., Day, M., Bobrie, G., & Menard, J. (1995) · Hypertension · doi:10.1161/01.hyp.25.2.294 · Cited by 72
Keenan, K., Hayen, A. D., Neal, B. C., & Irwig, L. (2009) · BMJ · doi:10.1136/bmj.b1492 · Cited by 63 · cited 2×
“These methods may also better identify medication treatment response over time, a process that is also confounded by high short-term variability (18, 43).”
BackgroundMethodBancej, C. M., Campbell, N. R. C., McKay, D. W., Nichol, M., Walker, R. L., & Kaczorowski, J. A. (2010) · Canadian Journal of Cardiology · doi:10.1016/s0828-282x(10)70382-2 · Cited by 60 · cited 1×
“Blood pressure is increasingly monitored by patients at home, and recent surveys report that approximately 43% of primary care patients with hypertension use home monitors (22, 23).”
BackgroundChanges in Home Versus Clinic Blood Pressure With Antihypertensive Treatments: A Meta-Analysis
Ishikawa, J., Carroll, D. J., Kuruvilla, S., Schwartz, J. E., & Pickering, T. G. (2008) · Hypertension · doi:10.1161/hypertensionaha.108.115600 · Cited by 50
Viera, A. J., Cohen, L. W., Mitchell, C. M., & Sloane, P. D. (2008) · Journal of Clinical Hypertension · doi:10.1111/j.1751-7176.2008.07530.x · Cited by 45 · cited 1×
“Blood pressure is increasingly monitored by patients at home, and recent surveys report that approximately 43% of primary care patients with hypertension use home monitors (22, 23).”
BackgroundTurner, M. J., & van Schalkwyk, J. M. (2007) · American Journal of Hypertension · doi:10.1038/ajh.2007.25 · Cited by 41
Brief report: How well do clinic-based blood pressure measurements agree with the mercury standard?
Kim, J. W., Bosworth, H. B., Voils, C. I., Olsen, M. K., Dudley, T. K., Gribbin, M., Adams, M. B., & Oddone, E. Ž. (2005) · Journal of General Internal Medicine · doi:10.1007/s11606-005-0112-6 · Cited by 33
Self-citationHow well do clinic-based blood pressure measurements agree with the mercury standard?
Kim, J. W., Bosworth, H. B., Voils, C. I., Olsen, M. K., Dudley, T. K., Gribbin, M., Adams, M. B., & Oddone, E. Ž. (2005) · PubMed Central · doi:10.1111/j.1525-1497.2005.0105.x · Cited by 30
Self-citationImproving Hypertension Quality Measurement Using Electronic Health Records
Persell, S. D., Kho, A., Thompson, J. A., & Baker, D. W. (2009) · Medical Care · doi:10.1097/mlr.0b013e31818b070c · Cited by 30
Brueren, M., Schouten, H. J. A., de Leeuw, P. W., van Montfrans, G. A., & van Ree, J. W. (1998) · Europe PMC (PubMed Central) · Cited by 29
Marshall, T. P. (2006) · Medical Decision Making · doi:10.1177/0272989x06295356 · Cited by 24
Compared With Whom? Addressing the Prognostic Value of Ambulatory Blood Pressure Categories
Verdecchia, P., Angeli, F., & Staessen, J. A. (2006) · Hypertension · doi:10.1161/01.hyp.0000215364.56025.b9 · Cited by 16
Epidemiologic Assessment of the Role of Blood Pressure in Stroke: The Framingham Study
Kannel, W. B. (1970) · JAMA · doi:10.1001/jama.1970.03180020021004 · Cited by 2
Cited by
Whelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Hypertension · doi:10.1161/hyp.0000000000000065 · Cited by 7,391
Whelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.11.006 · Cited by 6,616
Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., et al. (2019) · Hypertension · doi:10.1161/hyp.0000000000000087 · Cited by 1,512
“In a study of men taking antihypertensive medication, at least 5 BP measurements were needed to be 80% certain whether SBP was <140 mm Hg or not.(69) The 2017 Hypertension Clinical Practice Guidelines recommend measuring BP ≥2 times at a clinic visit.”
BackgroundWhelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Circulation · doi:10.1161/cir.0000000000000596 · Cited by 1,127
Diabetes and hypertension: a position statement by the American Diabetes Association
de Boer, I. H., Bangalore, S., Benetos, A., Davis, A. M., Michos, E. D., Muntner, P., Rossing, P., Zoungas, S., & Bakris, G. (2017) · Diabetes Care · doi:10.2337/dci17-0026 · Cited by 714
“To reducewithinpatient variability, blood pressure should bemeasured after 5min of rest, 2–3 readings should be taken 1–2min apart, and blood pressure measurements should be averaged (16).”
Background
Metadata
- Authors
- Powers, B. J., Olsen, M. K., Smith, V. A., Woolson, R. F., Bosworth, H. B., & Oddone, E. Z.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-06-21
- Volume
- 154
- Issue
- 12
- Pages
- 781-788
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2153830825
- Cited by
- 186
- References
- 50
- FWCI
- 13.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.