The DOI matches its Crossref record.
Electromyography: Physiology, Engineering, and Noninvasive Applications
Abstract
Introduction. Contributors. 1 BASIC PHYSIOLOGY AND BIOPHYSICS OF EMG SIGNAL GENERATION (T. Moritani, D. Stegeman, R. Merletti). 1.1 Introduction. 1.2 Basic Physiology of Motor Control and Muscle Contraction. 1.3 Basic Electrophysiology of the Muscle Cell Membrane. References. 2 NEEDLE AND WIRE DETECTION TECHNIQUES (J. V. Trontelj, J. Jabre, M. Mihelin). 2.1 Anatomical and Physiological Background of Intramuscular Recording. 2.2 Recording Characteristics of Needle Electrodes. 2.3 Conventional Needle EMG. 2.4 Special Needle Recording Techniques. 2.5 Physical Characteristics of Needle EMG Signals. 2.6 Recording Equipment. References. 3 DECOMPOSITION OF INTRAMUSCULAR EMG SIGNALS (D. W. Stashuk, D. Farina, K. Sogaard). 3.1 Introduction. 3.2 Basic Steps for EMG Signal Decomposition. 3.3 Evaluation of Performance of EMG Signal Decomposition Algorithms. 3.4 Applications of Results of the Decomposition of an Intramuscular EMG Signal. 3.5 Conclusions. References. 4 BIOPHYSICS OF THE GENERATION OF EMG SIGNALS (D. Farina, R. Merletti, D. F. Stegeman). 4.1 Introduction. 4.2 EMG Signal Generation. 4.3 Crosstalk. 4.4 Relationships between Surface EMG Features and Developed Force. 4.5 Conclusions. References. 5 DETECTION AND CONDITIONING OF THE SURFACE EMG SIGNAL (R. Merletti, H. Hermens). 5.1 Introduction. 5.2 Electrodes: Their Transfer Function. 5.3 Electrodes: Their Impedance, Noise, and dc Voltages. 5.4 Electrode Configuration, Distance, Location. 5.5 EMG Front--End Amplifiers. 5.6 EMG Filters: Specifications. 5.7 Sampling and A/D Conversion. 5.8 European Recommendations on Electrodes and Electrode Locations. References. 6 SINGLE--CHANNEL TECHNIQUES FOR INFORMATION EXTRACTION FROM THE SURFACE EMG SIGNAL (E. A. Clancy, D. Farina, G. Filligoi). 6.1 Introduction. 6.2 Spectral Estimation of Deterministic Signals and Stochastic Processes. 6.3 Basic Surface EMG Signal Models. 6.4 Surface EMG Amplitude Estimation. 6.5 Extraction of Information in Frequency Domain from Surface EMG Signals. 6.6 Joint Analysis of EMG Spectrum and Amplitude (JASA). 6.7 Recurrence Quantification Analysis of Surface EMG Signals. 6.8 Conclusions. References. 7 MULTI--CHANNEL TECHNIQUES FOR INFORMATION EXTRACTION FROM THE SURFACE EMG (D. Farina, R. Merletti, C. Disselhorst--Klug). 7.1 Introduction. 7.2 Spatial Filtering. 7.3 Spatial Sampling. 7.4 Estimation of Muscle--Fiber Conduction Velocity. 7.5 Conclusions. References. 8 EMG MODELING AND SIMULATION (D. F. Stegeman, R. Merletti, H. J. Hermens). 8.1 Introduction. 8.2 Phenomenological Models of EMG. 8.3 Elements of Structure--Based SEMG Models. 8.4 Basic Assumptions. 8.5 Elementary Sources of Bioelectric Muscle Activity. 8.6 Fiber Membrane Activity Profiles, Their Generation, Propagation, and Extinction. 8.7 Structure of the Motor Unit. 8.8 Volume Conduction. 8.9 Modeling EMG Detection Systems. 8.10 Modeling Motor Unit Recruitment and Firing Behavior. 8.11 Inverse Modeling. 8.12 Modeling of Muscle Fatigue. 8.13 Other Applications of Modeling. 8.14 Conclusions. References. 9 MYOELECTRIC MANIFESTATIONS OF MUSCLE FATIGUE (R. Merletti, A. Rainoldi, D. Farina). 9.1 Introduction. 9.2 Definitions and Sites of Neuromuscular Fatigue. 9.3 Assessment of Muscle Fatigue. 9.4 How Fatigue Is Reflected in Surface EMG Variables. 9.5 Myoelectric Manifestations of Muscle Fatigue in Isometric Voluntary Contractions. 9.6 Fiber Typing and Myoelectric Manifestations of Muscle Fatigue. 9.7 Factors Affecting Surface EMG Variable. 9.8 Repeatability of Estimates of EMG Variables and Fatigue Indexes. 9.9 Conclusions. References. 10 ADVANCED SIGNAL PROCESSING TECHNIQUES (D. Zazula, S. Karlsson, C. Doncarli). 10.1 Introduction. 10.2 Theoretical Background. 10.3 Decomposition of EMG Signals. 10.4 Applications to Monitoring Myoelectric Manifestations of Muscle Fatigue. 10.5 Conclusions. Acknowledgment. References. 11 SURFACE MECHANOMYOGRAM (C. Orizio). 11.1 The Mechanomyogram (MMG): General Aspects during Stimulated and Voluntary Contraction. 11.2 Detection Techniques and Sensors Comparison. 11.3 Comparison between Different Detectors. 11.4 Simulation. 11.5 MMG Versus Force: Joint and Adjunct Information Content. 11.6 MMG Versus EMG: Joint and Adjunct Information Content. 11.7 Area of Application. References. 12 SURFACE EMG APPLICATIONS IN NEUROLOGY (M. J. Zwarts, D. F. Stegeman, J. G. van Dijk). 12.1 Introduction. 12.2 Central Nervous System Disorders and SEMG. 12.3 Compound Muscle Action Potential and Motor Nerve Conduction. 12.4 CMAP Generation. 12.5 Clinical Applications. 12.6 Pathological Fatigue. 12.7 New Avenues: High--Density Multichannel Recording. 12.8 Conclusion. References. 13 APPLICATIONS IN ERGONOMICS (G. M. Hagg, B. Melin, R. Kadefors). 13.1 Historic Perspective. 13.2 Basic Workload Concepts in Ergonomics. 13.3 Basic Surface EMG Signal Processing. 13.4 Load Estimation and SEMG Normalization and Calibration. 13.5 Amplitude Data Reduction over Time. 13.6 Electromyographic Signal Alterations Indicating Muscle Fatigue i
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Surface EMG based muscle fatigue evaluation in biomechanics
Cifrek, M., Medved, V., Tonković, S., & Ostojić, S. (2009) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2009.01.010 · Cited by 954
Myoelectric signal processing for control of powered limb prostheses
Parker, P., Englehart, K., & Hudgins, B. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.08.006 · Cited by 651
Multichannel Blind Source Separation Using Convolution Kernel Compensation
Holobar, A., & Zazula, D. (2007) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2007.896108 · Cited by 648
Multi-channel intramuscular and surface EMG decomposition by convolutive blind source separation
Negro, F., Muceli, S., Castronovo, A. M., Holobar, A., & Farina, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026027 · Cited by 647
Myoelectric forearm prostheses: State of the art from a user-centered perspective
Peerdeman, B., Boere, D., Witteveen, H., Huis in `tVeld, R., Hermens, H., Stramigioli, S., Rietman, H., Veltink, P., & Misra, S. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.08.0161 · Cited by 469
Disselhorst-Klug, C., Schmitz-Rode, T., & Rau, G. (2009) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2008.08.003 · Cited by 414
Holobar, A., Minetto, M. A., & Farina, D. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/1/016008 · Cited by 400
Ardley, H. C., & Robinson, P. A. (2005) · Essays in Biochemistry · doi:10.1042/bse0410015 · Cited by 390
Training adaptations in the behavior of human motor units
Duchateau, J., Semmler, J. G., & Enoka, R. M. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00543.2006 · Cited by 354
Can muscle coordination be precisely studied by surface electromyography?
Hug, F. (2011) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2010.08.009 · Cited by 352
A Novel Feature Extraction for Robust EMG Pattern Recognition
Phinyomark, A., Limsakul, C., & Phukpattaranont, P. (2009) · arXiv (Cornell University) · doi:10.48550/arxiv.0912.3973 · Cited by 351
Merletti, R., Botter, A., Troiano, A., Merlo, E., & Minetto, M. A. (2009) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2008.08.006 · Cited by 345
Enabling always-available input with muscle-computer interfaces
Saponas, T. S., Tan, D. S., Morris, D., Balakrishnan, R., Turner, J., & Landay, J. A. (2009) · Proceedings of the 22nd annual ACM symposium on User interface software and technology · doi:10.1145/1622176.1622208 · Cited by 328
Estimating motor unit discharge patterns from high-density surface electromyogram.
Holobar, A., Farina, D., Gazzoni, M., Merletti, R., & Zazula, D. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.10.160 · Cited by 318
Clinical applications of high-density surface EMG: A systematic review
Drost, G., Stegeman, D. F., van Engelen, B. G. M., & Zwarts, M. J. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.09.005 · Cited by 311
Electromyographic models to assess muscle fatigue
González-Izal, M., Malanda, A., Gorostiaga, E., & Izquierdo, M. (2012) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2012.02.019 · Cited by 310
A Review of Non-Invasive Techniques to Detect and Predict Localised Muscle Fatigue
Al-Mulla, M. R., Sepulveda, F., & Colley, M. (2011) · Sensors · doi:10.3390/s110403545 · Cited by 310
Current state of digital signal processing in myoelectric interfaces and related applications
Hakonen, M., Piitulainen, H., & Visala, A. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.02.009 · Cited by 305
The Usefulness of Mean and Median Frequencies in Electromyography Analysis
Phinyomark, A., Thongpanja, S., Hu, H., Phukpattaranont, P., & Limsakul, C. (2012) · Computational Intelligence in Electromyography Analysis - A Perspective on Current Applications and Future Challenges · doi:10.5772/50639 · Cited by 294
Summary of over Fifty Years with Brain-Computer Interfaces—A Review
Kawala-Sterniuk, A., Browarska, N., Al-Bakri, A., Pelc, M., Zygarlicki, J., Sidikova, M., Martinek, R., & Gorzelanczyk, E. J. (2021) · Brain Sciences · doi:10.3390/brainsci11010043 · Cited by 292
Young, A. J., Hargrove, L. J., & Kuiken, T. A. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2159216 · Cited by 287
Muceli, S., & Farina, D. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2178039 · Cited by 285
Demonstrating the feasibility of using forearm electromyography for muscle-computer interfaces
Saponas, T. S., Tan, D. S., Morris, D., & Balakrishnan, R. (2008) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/1357054.1357138 · Cited by 275
Nielsen, J. L. G., Holmgaard, S., Jiang, N., Englehart, K. B., Farina, D., & Parker, P. A. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2068298 · Cited by 260
Lucas, M.-F., Gaufriau, A., Pascual, S., Doncarli, C., & Farina, D. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.09.002 · Cited by 253
Electromechanical delay revisited using very high frame rate ultrasound
Nordez, A., Gallot, T., Catheline, S., Guével, A., Cornu, C., & Hug, F. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00221.2009 · Cited by 153
Ortiz-Catalan, M., Brånemark, R., Håkansson, B., & Delbeke, J. (2012) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-11-33 · Cited by 144
Mastinu, E., Clemente, F., Sassu, P., Aszmann, O., Brånemark, R., Håkansson, B., Controzzi, M., Cipriani, C., & Ortiz-Catalan, M. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0511-2 · Cited by 87
Seidel, D. H., Ditchen, D. M., Hoehne-Hückstädt, U. M., Rieger, M. A., & Steinhilber, B. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph16010130 · Cited by 43
An electrooptical muscle contraction sensor
Chianura, A., & Giardini, M. E. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0626-x · Cited by 23
Intelligent Systems for Muscle Tracking: A Review on Sensor‐Algorithm Synergy
Putcha, A., Nguyen, T., Smith, R., Choffin, R., & Bai, W. (2023) · Advanced Intelligent Systems · doi:10.1002/aisy.202200351 · Cited by 10
Metadata
- Venue
- Wiley eBooks
- Publisher
- Wiley
- Published
- 2004-07-12
- OpenAlex
- W629053621
- Cited by
- 1,151
- References
- 0
- FWCI
- 17.49
- Type
- book
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.