CoChat

Soft Bioelectronic Stickers: Selection and Evaluation of Skin‐Interfacing Electrodes

Lopes, Pedro Alhais, Vaz Gomes, Davide, Green Marques, Daniel, Faia, Pedro, Góis, Joana, Patrício, Tatiana F., Coelho, Jorge, Serra, Arménio, de Almeida, Aníbal T., Majidi, Carmel, Tavakoli, Mahmoud · 2019 · Advanced Healthcare Materials
Cited by 109

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

Surface biopotentials collected from the human epidermis contain important information about human physiology, such as muscular, heart, and brain activities. However, commercially available wearable biomonitoring devices are generally composed of rigid hardware incompatible with the mechanical compliance of soft human tissues. Thin‐film stretchable e‐skin circuits that can interface the human skin represent an excellent alternative for long‐term wearable biomonitoring. Here, a series of soft and stretchable electrodes are evaluated for their applicability in biopotential sensing. This includes conductive composites made of polydimethylsiloxane (PDMS) as a base substrate and conductive particles, i.e., carbon (cPDMS), silver (AgPDMS), anisotropic z‐axis conductors made with silver‐coated nickel particles (zPDMS), as well as a combination of a conductive tough hydrogel with PDMS, and finally ultrathin tattoo‐like adhesive poly(vinyl alcohol)‐coated films with stretchable biphasic Ag‐EGaIn electrodes. These electrodes are compared between themselves and against the gold‐standard Ag/AgCl and stainless steel electrodes, in order to assess relative performance in signal‐to‐noise ratio (SNR) during electrocardiography, and electrode‐skin impedance for a range of frequencies. Results show a direct relation between conformity of the electrode–skin interface and the SNR value. An all‐integrated biomonitoring patch with embedded processing and communication electronics, hydrogel electrodes, and a multilayer liquid metal circuit is presented for electromyography.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adhm.201900234

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 109

Metadata

Authors
Lopes, P. A., Vaz Gomes, D., Green Marques, D., Faia, P., Góis, J., Patrício, T. F., Coelho, J., Serra, A., de Almeida, A. T., Majidi, C., & Tavakoli, M.
Venue
Advanced Healthcare Materials
Publisher
Wiley
Published
2019-07-05
Volume
8
Issue
15
Pages
e1900234-e1900234
ISSN
  • 2192-2640 (ISSN-L)
  • 2192-2659
OpenAlex
W2954132194
Cited by
109
References
14
FWCI
4.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Soft Bioelectronic Stickers: Selection and Evaluation of Skin‐Interfacing Electrodes. https://app.cochat.ai/papers/10.1002/adhm.201900234
The paper
Lopes, P. A., Vaz Gomes, D., Green Marques, D., Faia, P., Góis, J., Patrício, T. F., Coelho, J., Serra, A., de Almeida, A. T., Majidi, C., & Tavakoli, M. (2019). Soft Bioelectronic Stickers: Selection and Evaluation of Skin‐Interfacing Electrodes. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.201900234

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.