The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Stable, Wavelength‐Tunable Fluorescent Dyes in the NIR‐II Region for In Vivo High‐Contrast Bioimaging and Multiplexed Biosensing
Abstract
Small‐molecule organic fluorophores, spectrally active in the 900–1700 nm region, with tunable wavelength and sensing properties are sought‐after for in vivo optical imaging and biosensing. A panel of fluorescent dyes (CX) has been developed to meet this challenge. CX dyes exhibit the wavelength tunability of cyanine dyes and have a rigidified polymethine chain to guarantee their stability. They are chemo‐ and photo‐stable in an aqueous environment and have tunable optical properties with maximal absorbing/emitting wavelength at 1089/1140 nm. They show great potential in high‐contrast in vivo bioimaging and multicolor detection with negligible optical cross talk. Förster resonance energy transfer (FRET) between CX dyes was demonstrated in deep tissue, providing an approach for monitoring drug‐induced hepatotoxicity by detection of OONO−. This report presents a series of NIR‐II dyes with promising spectroscopic properties for high‐contrast bioimaging and multiplexed biosensing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Second window for in vivo imaging
Smith, A. M., Mancini, M. C., & Nie, S. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.326 · Cited by 2,848
A small-molecule dye for NIR-II imaging
Antaris, A. L., Chen, H., Cheng, K., Sun, Y., Hong, G., Qu, C., Diao, S., Deng, Z., Hu, X., Zhang, B., et al. (2016) · Nature Materials · doi:10.1038/nmat4476 · Cited by 1,778
Self-citationA route to brightly fluorescent carbon nanotubes for near-infrared imaging in mice
Welsher, K., Liu, Z., Sherlock, S. P., Robinson, J. T., Chen, Z., Daranciang, D., & Dai, H. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.294 · Cited by 1,287
He, S., Song, J., Qu, J., & Cheng, Z. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00234g · Cited by 1,021
Next-generation in vivo optical imaging with short-wave infrared quantum dots
Bruns, O. T., Bischof, T. S., Harris, D. K., Franke, D., Shi, Y., Riedemann, L., Bartelt, A., Jaworski, F. B., Carr, J. A., Rowlands, C. J., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0056 · Cited by 686
Optical nano-agents in the second near-infrared window for biomedical applications
Cai, Y., Wei, Z., Song, C., Tang, C., Han, W., & Dong, X. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00494c · Cited by 603
Donor Engineering for NIR-II Molecular Fluorophores with Enhanced Fluorescent Performance
Yang, Q., Hu, Z., Zhu, S., Ma, R., Ma, H., Ma, Z., Wan, H., Zhu, T., Jiang, Z., Liu, W., et al. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.7b10334 · Cited by 554
Ding, B., Xiao, Y., Zhou, H., Zhang, X., Qu, C., Xu, F., Deng, Z., Cheng, Z., & Hong, X. (2019) · Journal of Medicinal Chemistry · doi:10.1021/acs.jmedchem.8b01682 · Cited by 215
Self-citation
Cited by
Advanced Fluorescence Imaging Technology in the Near-Infrared-II Window for Biomedical Applications
Li, C., Chen, G., Zhang, Y., Wu, F., & Wang, Q. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c07022 · Cited by 1,037
J -Aggregates of Cyanine Dye for NIR-II in Vivo Dynamic Vascular Imaging beyond 1500 nm
Sun, C., Li, B., Zhao, M., Wang, S., Lei, Z., Lu, L., Zhang, H., Feng, L., Dou, C., Yin, D., et al. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b10043 · Cited by 582
Self-citationOrganic NIR-II molecule with long blood half-life for in vivo dynamic vascular imaging
Li, B., Zhao, M., Feng, L., Dou, C., Ding, S., Zhou, G., Lu, L., Zhang, H., Chen, F., Li, X., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-16924-z · Cited by 374
Self-citationJ-aggregates of meso-[2.2]paracyclophanyl-BODIPY dye for NIR-II imaging
Li, K., Duan, X., Jiang, Z., Ding, D., Chen, Y., Zhang, G.-Q., & Liu, Z. (2021) · Nature Communications · doi:10.1038/s41467-021-22686-z · Cited by 301
NIR-II bioluminescence for in vivo high contrast imaging and in situ ATP-mediated metastases tracing
Lu, L., Li, B., Ding, S., Fan, Y., Wang, S., Sun, C., Zhao, M., Zhao, C.-X., & Zhang, F. (2020) · Nature Communications · doi:10.1038/s41467-020-18051-1 · Cited by 274
Self-citation
Metadata
- Authors
- Lei, Z., Sun, C., Pei, P., Wang, S., Li, D., Zhang, X., & Zhang, F.
- Venue
- Angewandte Chemie
- Publisher
- Wiley
- Published
- 2019-05-08
- Volume
- 131
- Issue
- 24
- Pages
- 8250-8255
- ISSN
- 0044-8249 (ISSN-L)
- 1521-3757
- OpenAlex
- W4252056368
- Cited by
- 208
- References
- 8
- FWCI
- 15.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stable, Wavelength‐Tunable Fluorescent Dyes in the NIR‐II Region for In Vivo High‐Contrast Bioimaging and Multiplexed Biosensing. https://app.cochat.ai/papers/10.1002/ange.201904182
- The paper
- Lei, Z., Sun, C., Pei, P., Wang, S., Li, D., Zhang, X., & Zhang, F. (2019). Stable, Wavelength‐Tunable Fluorescent Dyes in the NIR‐II Region for In Vivo High‐Contrast Bioimaging and Multiplexed Biosensing. Angewandte Chemie. https://doi.org/10.1002/ange.201904182
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.