The DOI matches its Crossref record; 71 of the 71 references it cites were found in a registry or an index.
Microfluidics Based Point‐of‐Care Diagnostics
Abstract
Point‐of‐care (POC) diagnostic devices have been predicted to provide a boon in health care especially in the diagnosis and detection of diseases. POC devices have been found to have many advantages like a rapid and precise response, portability, low cost, and non‐requirement of specialized equipment. The major objective of a POC diagnostic research is to develop a chip‐based, self‐containing miniaturized device that can be used to examine different analytes in complex samples. Further, the integration of microfluidics (MF) with advanced biosensor technologies is likely to result in improved POC diagnostics. This paper presents the overview of the different materials (glass, silicon, polymer, paper) and techniques for the fabrication of MF based POC devices along with their wide range of biosensor applications. Besides this, the authors have presented in brief the challenges that MF is currently facing along with possible solutions that may result in the availability of the accessible, reliable, and cost‐efficient technology. The development of these devices requires the combination of developed MF components into POC devices that are user‐friendly, sensitive, stable, accurate, low cost, and minimally invasive. These MF based POC devices have tremendous potential in providing improved healthcare including easy monitoring, early detection of disease, and increased personalization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Paper-based microfluidic point-of-care diagnostic devices
Yetisen, A. K., Akram, M. S., & Lowe, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50169h · Cited by 1,943
Understanding Wax Printing: A Simple Micropatterning Process for Paper-Based Microfluidics
Carrilho, E., Martinez, A. W., & Whitesides, G. M. (2009) · Analytical Chemistry · doi:10.1021/ac901071p · Cited by 1,612
A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Becker, H. (2002) · Talanta · doi:10.1016/s0039-9140(01)00594-x · Cited by 1,187
Commercialization of microfluidic point-of-care diagnostic devices
Chin, C. D., Linder, V., & Sia, S. K. (2012) · Lab on a Chip · doi:10.1039/c2lc21204h · Cited by 1,124
Point-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
Diagnostics for the developing world
Mabey, D., Peeling, R. W., Ustianowski, A., & Perkins, M. D. (2004) · Nature Reviews Microbiology · doi:10.1038/nrmicro841 · Cited by 1,054
Advances in Microfluidic Materials, Functions, Integration, and Applications
Nge, P. N., Rogers, C. I., & Woolley, A. T. (2013) · Chemical Reviews · doi:10.1021/cr300337x · Cited by 958
3D printed microfluidics for biological applications
Ho, C. M. B., Ng, S. H., Li, K. H. H., & Yoon, Y.-J. (2015) · Lab on a Chip · doi:10.1039/c5lc00685f · Cited by 704
Point-of-care testing (POCT): Current techniques and future perspectives
Luppa, P. B., Müller, C., Schlichtiger, A., & Schlebusch, H. (2011) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.01.019 · Cited by 660
Low-Cost Printing of Poly(dimethylsiloxane) Barriers To Define Microchannels in Paper
Bruzewicz, D. A., Reches, M., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac702605a · Cited by 616
Fabrication of Plastic Microfluid Channels by Imprinting Methods
Martynova, L., Locascio, L. E., Gaitan, M., Kramer, G. W., Christensen, R. G., & MacCrehan, W. A. (1997) · Analytical Chemistry · doi:10.1021/ac970558y · Cited by 533
Tabeling, P., & Chen, S. (2005) · doi:10.1093/oso/9780198568643.001.0001 · Cited by 511
Colorimetric Detection of Urine Glucose Based ZnFe2O4 Magnetic Nanoparticles
Su, L., Feng, J., Zhou, X., Ren, C., Li, H., & Chen, X. (2012) · Analytical Chemistry · doi:10.1021/ac300939z · Cited by 503
Paper‐Based Inkjet‐Printed Microfluidic Analytical Devices
Yamada, K., Henares, T. G., Suzuki, K., & Citterio, D. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201411508 · Cited by 501
Saliva as a diagnostic tool for oral and systemic diseases
Javaid, M. A., Ahmed, A. S., Durand, R., & Tran, S. D. (2016) · Journal of Oral Biology and Craniofacial Research · doi:10.1016/j.jobcr.2015.08.006 · Cited by 431
A practical guide for the fabrication of microfluidic devices using glass and silicon
Iliescu, C., Taylor, H., Avram, M., Miao, J., & Franssila, S. (2012) · Biomicrofluidics · doi:10.1063/1.3689939 · Cited by 385
Review on Micro- and Nanolithography Techniques and their Applications
Pimpin, A., & Srituravanich, W. (2012) · Engineering Journal · doi:10.4186/ej.2012.16.1.37 · Cited by 363
Electrochemistry, biosensors and microfluidics: a convergence of fields
Rackus, D. G., Shamsi, M. H., & Wheeler, A. R. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00369a · Cited by 354
Cell-Based Biosensors and Their Application in Biomedicine
Liu, Q., Wu, C., Cai, H., Hu, N., Zhou, J., & Wang, P. (2014) · Chemical Reviews · doi:10.1021/cr2003129 · Cited by 348
Yakovleva, J., Davidsson, R., Lobanova, A., Bengtsson, M., Eremin, S., Laurell, T., & Emnéus, J. (2002) · Analytical Chemistry · doi:10.1021/ac015645b · Cited by 330
Multiplex Serum Cytokine Immunoassay Using Nanoplasmonic Biosensor Microarrays
Chen, P., Chung, M. T., McHugh, W., Nidetz, R., Li, Y., Fu, J., Cornell, T. T., Shanley, T. P., & Kurabayashi, K. (2015) · ACS Nano · doi:10.1021/acsnano.5b00396 · Cited by 321
Jansen, H. V., de Boer, M. J., Unnikrishnan, S., Louwerse, M. C., & Elwenspoek, M. C. (2009) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/19/3/033001 · Cited by 318
Soft lithography for microfluidics: a review
Kim, P., Kwon, K. W., Park, M. C., Lee, S. H., Kim, S. M., & Suh, K. Y. (2008) · Seoul National University Open Repository (Seoul National University) · Cited by 302
Microfluidics and point-of-care testing
Sia, S. K., & Kricka, L. J. (2008) · Lab on a Chip · doi:10.1039/b817915h · Cited by 279
Development and Applications of Portable Biosensors
Srinivasan, B., & Tung, S. (2015) · SLAS Technology · doi:10.1177/2211068215581349 · Cited by 262
Jokerst, J. V., Raamanathan, A., Christodoulides, N., Floriano, P. N., Pollard, A. A., Simmons, G. W., Wong, J., Gage, C., Furmaga, W. B., Redding, S. W., et al. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.05.026 · Cited by 253
Electrochemical paper-based peptide nucleic acid biosensor for detecting human papillomavirus
Teengam, P., Siangproh, W., Tuantranont, A., Henry, C. S., Vilaivan, T., & Chailapakul, O. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.11.071 · Cited by 236
Last Advances in Silicon-Based Optical Biosensors
Fernández Gavela, A., Grajales García, D., Ramirez, J., & Lechuga, L. (2016) · Sensors · doi:10.3390/s16030285 · Cited by 227
Wu, Y., Xue, P., Hui, K. M., & Kang, Y. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.08.039 · Cited by 200
Chen, K., & Hugh Fan, Z. (2016) · Circulating Tumor Cells · doi:10.1002/9781119244554.ch2 · Cited by 200
Microfluidic‐integrated biosensors: Prospects for point‐of‐care diagnostics
Kumar, S., Kumar, S., Ali, M. A., Anand, P., Agrawal, V. V., John, R., Maji, S., & Malhotra, B. D. (2013) · Biotechnology Journal · doi:10.1002/biot.201200386 · Cited by 199
Self-citationReview: Recent Developments in Enzyme-Based Biosensors for Biomedical Analysis
Ispas, C. R., Crivat, G., & Andreescu, S. (2012) · Analytical Letters · doi:10.1080/00032719.2011.633188 · Cited by 191
Micromachining of buried micro channels in silicon
de Boer, M. J., Tjerkstra, R. W., Berenschot, J. W., Jansen, H. V., Burger, G. J., Gardeniers, J. G. E., Elwenspoek, M., & van den Berg, A. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.825783 · Cited by 187
Ultraviolet Laser Photoablation of Polymers: A Review and Recent Results
Lazare, S., & Granier, V. (1988) · Laser Chemistry · doi:10.1155/1989/18750 · Cited by 184
Li, X., Zhao, C., & Liu, X. (2015) · Microsystems & Nanoengineering · doi:10.1038/micronano.2015.14 · Cited by 170
Fabrication of Low-Cost Paper-Based Microfluidic Devices by Embossing or Cut-and-Stack Methods
Thuo, M. M., Martinez, R. V., Lan, W.-J., Liu, X., Barber, J., Atkinson, M. B. J., Bandarage, D., Bloch, J.-F., & Whitesides, G. M. (2014) · Chemistry of Materials · doi:10.1021/cm501596s · Cited by 165
Maejima, K., Tomikawa, S., Suzuki, K., & Citterio, D. (2013) · RSC Advances · doi:10.1039/c3ra40828k · Cited by 165
Su, W., Cook, B. S., Fang, Y., & Tentzeris, M. M. (2016) · Scientific Reports · doi:10.1038/srep35111 · Cited by 162
Advances in three-dimensional rapid prototyping of microfluidic devices for biological applications
O’Neill, P., Azouz, A. B., Vázquez, M., Liu, J., Marczak, S. P., Slouka, Z., Chang, H., Diamond, D., & Brabazon, D. (2014) · Biomicrofluidics · doi:10.1063/1.4898632 · Cited by 161
Simple glucose sensors with micromolar sensitivity based on organic electrochemical transistors
Macaya, D. J., Nikolou, M., Takamatsu, S., Mabeck, J. T., Owens, R. M., & Malliaras, G. G. (2007) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2006.08.038 · Cited by 161
Mixed salivary glucose levels and candidal carriage in patients with diabetes mellitus
Darwazeh, A. M. G., MacFarlane, T. W., McCuish, A., & Lamey, P. ‐. (1991) · Journal of Oral Pathology & Medicine · doi:10.1111/j.1600-0714.1991.tb00928.x · Cited by 160
Cunningham, J. C., Brenes, N. J., & Crooks, R. M. (2014) · Analytical Chemistry · doi:10.1021/ac501438y · Cited by 160
New materials for microfluidics in biology
Ren, K., Chen, Y., & Wu, H. (2013) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2013.09.004 · Cited by 142
Progress in the development and integration of fluid flow control tools in paper microfluidics
Fu, E. S., & Downs, C. (2017) · Lab on a Chip · doi:10.1039/c6lc01451h · Cited by 141
Kumar, S., Kumar, S., Tiwari, S., Srivastava, S., Srivastava, M., Yadav, B. K., Kumar, S., Tran, T. T., Dewan, A. K., Mulchandani, A., et al. (2015) · Advanced Science · doi:10.1002/advs.201500048 · Cited by 140
Self-citationPaper-Based Colorimetric Biosensor for Tear Glucose Measurements
Gabriel, E. F. M., Garcia, P. D. T., Lopes, F. M., & Coltro, W. K. T. (2017) · Micromachines · doi:10.3390/mi8040104 · Cited by 132
An LTCC-based microfluidic system for label-free, electrochemical detection of cortisol
Vasudev, A., Kaushik, A. K., Tomizawa, Y., Norena, N., & Bhansali, S. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.02.096 · Cited by 129
Paper-Based Microfluidics: Fabrication Technique and Dynamics of Capillary-Driven Surface Flow
Songok, J., Tuominen, M., Teisala, H., Haapanen, J., Mäkelä, J. M., Kuusipalo, J., & Toivakka, M. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am5055806 · Cited by 121
Chen, J., Zhang, J., Guo, Y., et al. (2011) · Chemical Communications · doi:10.1039/c1cc11929j · Cited by 118
Syshchyk, O., Skryshevsky, V. A., Soldatkin, O. O., & Soldatkin, A. P. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.10.075 · Cited by 118
Li, L., Xu, J., Zheng, X., Ma, C., Song, X., Ge, S., Yu, J., & Yan, M. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.05.012 · Cited by 115
Theory, fabrication and applications of microfluidic and nanofluidic biosensors
Prakash, S., Pinti, M., & Bhushan, B. (2012) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2011.0498 · Cited by 113
Oral Fluid Nanosensor Test (OFNASET) with Advanced Electrochemical‐Based Molecular Analysis Platform
Gau, V., & Wong, D. T. (2007) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1384.005 · Cited by 100
Ji, X., Lau, H. Y., Ren, X., Peng, B., Zhai, P. C., Feng, S., & Chan, P. K. L. (2016) · Advanced Materials Technologies · doi:10.1002/admt.201600042 · Cited by 96
Flow-enhanced electrochemical immunosensors on centrifugal microfluidic platforms
Kim, T.-H., Abi‐Samra, K., Sunkara, V., Park, D.-K., Amasia, M., Kim, N., Kim, J. T., Kim, H., Madou, M. J., & Cho, Y. (2013) · Lab on a Chip · doi:10.1039/c3lc50374g · Cited by 85
Mitchell, J. S., Lowe, T. E., & Ingram, J. R. (2008) · The Analyst · doi:10.1039/b817083p · Cited by 79
Liu, Y., Matharu, Z., Howland, M. C., Revzin, A., & Simonian, A. L. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6149-6 · Cited by 75
Matharu, Z., Patel, D., Gao, Y., Haque, A., Zhou, Q., & Revzin, A. (2014) · Analytical Chemistry · doi:10.1021/ac502383e · Cited by 75
Bunyakul, N., & Baeumner, A. J. (2014) · Sensors · doi:10.3390/s150100547 · Cited by 67
An electrochemical immunosensing method for detecting melanoma cells
Seenivasan, R., Maddodi, N., Setaluri, V., & Gunasekaran, S. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.01.022 · Cited by 57
Ben‐Yoav, H., Dykstra, P. H., Bentley, W. E., & Reza Ghodssi, A. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.05.009 · Cited by 57
Kumar, S., Sharma, J. G., Maji, S., & Malhotra, B. D. (2016) · RSC Advances · doi:10.1039/c6ra07392a · Cited by 52
Self-citationBartholomew, C. H., & Farrauto, R. J. (2005) · doi:10.1002/9780471730071.ch1 · Cited by 44
Novel Concepts for Silicon-Based Biosensors
Sch√∂ning, M., & L�th, H. (2001) · physica status solidi (a) · doi:10.1002/1521-396x(200105)185:1<65::aid-pssa65>3.0.co;2-y · Cited by 44
A liposome-based ion release impedance sensor for biological detection
Damhorst, G. L., Smith, C. E., Salm, E. M., Sobieraj, M. M., Ni, H., Kong, H., & Bashir, R. (2013) · Biomedical Microdevices · doi:10.1007/s10544-013-9778-4 · Cited by 28
Zítka, O., Křížková, S., Skalíčková, S., Dospivová, D., Adam, V., & Kizek, R. (2013) · Electrophoresis · doi:10.1002/elps.201200631 · Cited by 13
Wang, Z., Chen, J., Fan, Y., Wang, W., & Fu, F. (2012) · Microfluidics and Nanofluidics · doi:10.1007/s10404-012-1032-5 · Cited by 13
Biological Applications of Microfluidics System
Solanki, S., & Pandey, C. M. (2016) · Springer eBooks · doi:10.1007/978-3-319-40036-5_8 · Cited by 7
Self-citation
Cited by
Costa, C. M., Cardoso, V. F., Martins, P., Correia, D. M., Gonçalves, R., Costa, P., Correia, V., Ribeiro, C., Fernandes, M. M., Martins, P. M., et al. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00196 · Cited by 498
Cell-based biosensors: Recent trends, challenges and future perspectives
Gupta, N., Renugopalakrishnan, V., Liepmann, D., Paulmurugan, R., & Malhotra, B. D. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111435 · Cited by 318
Self-citationNucleic Acid Tests for Clinical Translation
Li, M., Yin, F., Song, L., Mao, X., Li, F., Fan, C., Zuo, X., & Xia, Q. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00241 · Cited by 264
Microfluidic Point-of-Care Testing: Commercial Landscape and Future Directions
Sachdeva, S., Davis, R. W., & Saha, A. K. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.602659 · Cited by 262
Heidt, B., Siqueira, W., Eersels, K., Diliën, H., van Grinsven, B., Fujiwara, R., & Cleij, T. (2020) · Biosensors · doi:10.3390/bios10100133 · Cited by 260
Metadata
- Authors
- Pandey, C. M., Augustine, S., Kumar, S., Kumar, S., Nara, S., Srivastava, S., & Malhotra, B. D.
- Venue
- Biotechnology Journal
- Publisher
- Wiley
- Published
- 2017-12-18
- Volume
- 13
- Issue
- 1
- ISSN
- 1860-6768 (ISSN-L)
- 1860-7314
- OpenAlex
- W2770448154
- Cited by
- 273
- References
- 71
- FWCI
- 9.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.