The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
A New Nanobiosensor for Glucose with High Sensitivity and Selectivity in Serum Based on Fluorescence Resonance Energy Transfer (FRET) between CdTe Quantum Dots and Au Nanoparticles
Abstract
A novel assembled nanobiosensor QDs‐ConA‐β‐CDs‐AuNPs was designed for the direct determination of glucose in serum with high sensitivity and selectivity. The sensing approach is based on fluorescence resonance energy transfer (FRET) between CdTe quantum dots (QDs) as an energy donor and gold nanoparticles (AuNPs) as an energy acceptor. The specific combination of concanavalin A (ConA)‐conjugated QDs and thiolated β‐cyclodextrins (β‐SH‐CDs)‐modified AuNPs assembles a hyperefficient FRET nanobiosensor. In the presence of glucose, the AuNPs‐β‐CDs segment of the nanobiosensor is displaced by glucose which competes with β‐CDs on the binding sites of ConA, resulting in the fluorescence recovery of the quenched QDs. Experimental results show that the increase in fluorescence intensity is proportional to the concentration of glucose within the range of 0.10–50 μ M under the optimized experimental conditions. In addition, the nanobiosensor has high sensitivity with a detection limit as low as 50 n M, and has excellent selectivity for glucose over other sugars and most biological species present in serum. The nanobiosensor was applied directly to determine glucose in normal adult human serum, and the recovery and precision of the method were satisfactory. The unique combination of high sensitivity and good selectivity of this biosensor indicates its potential for the clinical determination of glucose directly and simply in serum, and provides the possibility to detect low levels of glucose in single cells or bacterial cultures. Moreover, the designed nanobiosensor achieves direct detection in biological samples, suggesting the use of nanobiotechnology‐based assembled sensors for direct analytical applications in vivo or in vitro.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Controlled Nucleation for the Regulation of the Particle Size in Monodisperse Gold Suspensions
FRENS, G. (1973) · Nature Physical Science · doi:10.1038/physci241020a0 · Cited by 8,336
Self-assembled nanoscale biosensors based on quantum dot FRET donors
Medintz, I. L., Clapp, A. R., Mattoussi, H., Goldman, E. R., Fisher, B., & Mauro, J. M. (2003) · Nature Materials · doi:10.1038/nmat961 · Cited by 1,601
Fluorescence Resonant Energy Transfer Biosensor Based on Upconversion‐Luminescent Nanoparticles
Wang, L., Yan, R., Huo, Z., Wang, L., Zeng, J., Bao, J., Wang, X., Peng, Q., & Li, Y. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200501907 · Cited by 901
Semiconductor Quantum Dots for Photodynamic Therapy
Samia, A. C. S., Chen, X., & Burda, C. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0386905 · Cited by 813
Hypoglycemia in the Diabetes Control and Complications Trial
The Diabetes Control and Complications Trial Research Group (1997) · Diabetes · doi:10.2337/diab.46.2.271 · Cited by 746
Strongly Photoluminescent CdTe Nanocrystals by Proper Surface Modification
Gao, M., Kirstein, S., Möhwald, H., Rogach, A. L., Kornowski, A., Eychmüller, A., & Weller, H. (1998) · The Journal of Physical Chemistry B · doi:10.1021/jp9823603 · Cited by 684
A Hybrid Quantum Dot−Antibody Fragment Fluorescence Resonance Energy Transfer-Based TNT Sensor
Goldman, E. R., Medintz, I. L., Whitley, J. L., Hayhurst, A., Clapp, A. R., Uyeda, H. T., Deschamps, J. R., Lassman, M. E., & Mattoussi, H. (2005) · Journal of the American Chemical Society · doi:10.1021/ja043677l · Cited by 571
Oh, E., Hong, M.-Y., Lee, D., Nam, S.-H., Yoon, H. C., & Kim, H.-S. (2005) · Journal of the American Chemical Society · doi:10.1021/ja0433323 · Cited by 512
Fan, C., Wang, S., Hong, J. W., Bazan, G. C., Plaxco, K. W., & Heeger, A. J. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1132025100 · Cited by 502
CdSe−ZnS Quantum Dots as Resonance Energy Transfer Donors in a Model Protein−Protein Binding Assay
Willard, D. M., Carillo, L. L., Jung, J., & Van Orden, A. (2001) · Nano Letters · doi:10.1021/nl015565n · Cited by 493
Nanotechnology in clinical laboratory diagnostics
Jain, K. K. (2005) · Clinica Chimica Acta · doi:10.1016/j.cccn.2005.03.014 · Cited by 453
Protein-carbohydrate interaction I. The interaction of polysaccharides with concanavalin A
Goldstein, I. J., Hollerman, C. E., & Merrick, J. M. (1965) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(65)90270-9 · Cited by 354
Russell, R. J., Pishko, M. V., Gefrides, C. C., McShane, M. J., & Coté, G. L. (1999) · Analytical Chemistry · doi:10.1021/ac990060r · Cited by 353
Synthesis and Application of Quantum Dots FRET-Based Protease Sensors
Shi, L., De Paoli, V., Rosenzweig, N., & Rosenzweig, Z. (2006) · Journal of the American Chemical Society · doi:10.1021/ja063509o · Cited by 352
Schultz, J. S., Mansouri, S., & Goldstein, I. J. (1982) · Diabetes Care · doi:10.2337/diacare.5.3.245 · Cited by 305
Amperometric Glucose Biosensor Based on Sol−Gel Organic−Inorganic Hybrid Material
Wang, B., Li, B., Deng, Q., & Dong, S. (1998) · Analytical Chemistry · doi:10.1021/ac980160h · Cited by 299
Fast Responsive Crystalline Colloidal Array Photonic Crystal Glucose Sensors
Ben-Moshe, M., Alexeev, V. L., & Asher, S. A. (2006) · Analytical Chemistry · doi:10.1021/ac060643i · Cited by 292
Sensors for glucose monitoring: technical and clinical aspects
Koschinsky, T., & Heinemann, L. (2001) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.188 · Cited by 288
Barone, P. W., Parker, R. S., & Strano, M. S. (2005) · Analytical Chemistry · doi:10.1021/ac0511997 · Cited by 279
Mann, D. A., Kanai, M., Maly, D. J., & Kiessling, L. L. (1998) · Journal of the American Chemical Society · doi:10.1021/ja9818506 · Cited by 277
DNA Hybridization Detection with Blue Luminescent Quantum Dots and Dye-Labeled Single-Stranded DNA
Peng, H., Zhang, L., Kjällman, T. H. M., Soeller, C., & Travas-Sejdic*, J. (2007) · Journal of the American Chemical Society · doi:10.1021/ja0685452 · Cited by 269
Quenching of CdSe quantum dot emission, a new approach for biosensing
Dyadyusha, L., Yin, H., Jaiswal, S., Brown, T., Baumberg, J. J., Booy, F. P., & Melvin, T. (2005) · Chemical Communications · doi:10.1039/b500664c · Cited by 209
A Fluorescence Affinity Hollow Fiber Sensor for Continuous Transdermal Glucose Monitoring
Ballerstadt, R., & Schultz, J. S. (2000) · Analytical Chemistry · doi:10.1021/ac000215r · Cited by 192
Chen, S.-J., & Chang, H.-T. (2004) · Analytical Chemistry · doi:10.1021/ac049787s · Cited by 186
Glucose-Sensitive Holographic Sensors for Monitoring Bacterial Growth
Lee, M.-C., Kabilan, S., Hussain, A., Yang, X., Blyth, J., & Lowe, C. R. (2004) · Analytical Chemistry · doi:10.1021/ac049334n · Cited by 167
Aslan, K., Lakowicz, J. R., & Geddes, C. D. (2005) · Analytical Chemistry · doi:10.1021/ac0484880 · Cited by 161
Fluorescence Glucose Detection: Advances Toward the Ideal In Vivo Biosensor
Moschou, E. A., Sharma, B. V., Deo, S. K., & Daunert, S. (2004) · Journal of Fluorescence · doi:10.1023/b:jofl.0000039341.64999.83 · Cited by 154
Hasegawa, T., Kondoh, S., Matsuura, K., & Kobayashi, K. (1999) · Macromolecules · doi:10.1021/ma990444j · Cited by 128
Fiber-optic biosensors based on fluorescence energy transfer
Meadows, D. L. (1988) · Talanta · doi:10.1016/0039-9140(88)80053-5 · Cited by 127
Dextran−Gold Nanoparticle Hybrid Material for Biomolecule Immobilization and Detection
Lee, S., & Pérez-Luna, V. H. (2005) · Analytical Chemistry · doi:10.1021/ac050484n · Cited by 92
Dual-Labeled Glucose Binding Protein for Ratiometric Measurements of Glucose
Ge, X., Tolosa, L. M., & Rao, G. (2004) · Analytical Chemistry · doi:10.1021/ac035063p · Cited by 89
Nanoprobes and nanobiosensors for monitoring and imaging individual living cells
Vo‐Dinh, T., Kasili, P. M., & Wabuyele, M. B. (2006) · Nanomedicine Nanotechnology Biology and Medicine · doi:10.1016/j.nano.2005.10.012 · Cited by 88
Silicon nanowires for high-sensitivity glucose detection
Chen, W., Yao, H. Q., Tzang, C. H., Zhu, J., Yang, M., & Lee, S. (2006) · Applied Physics Letters · doi:10.1063/1.2206102 · Cited by 80
In vivo glucose sensing for diabetes management: progress towards non-invasive monitoring
Pickup, J., McCartney, L., Rolinski, O., & Birch, D. (1999) · BMJ · doi:10.1136/bmj.319.7220.1289 · Cited by 66
Using an Indicator Displacement Assay to Monitor Glucose Oxidase Activity in Blood Serum
Zhang, T., & Anslyn, E. V. (2007) · Organic Letters · doi:10.1021/ol070280o · Cited by 57
Cited by
Gold Nanoparticles in Chemical and Biological Sensing
Saha, K., Agasti, S. S., Kim, C., Li, X., & Rotello, V. M. (2012) · Chemical Reviews · doi:10.1021/cr2001178 · Cited by 4,620
Gold Nanoparticles for In Vitro Diagnostics
Zhou, W., Gao, X., Liu, D., & Chen, X. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00100 · Cited by 901
Hildebrandt, N., Spillmann, C. M., Algar, W. R., Pons, T., Stewart, M. H., Oh, E., Susumu, K., Díaz, S. A., Delehanty, J. B., & Medintz, I. L. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00030 · Cited by 730
Algar, W. R., Tavares, A. J., & Krull, U. J. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.05.026 · Cited by 511
Quantum Dots for Live Cell and In Vivo Imaging
Walling, M. A., Novak, J. A., & Shepard, J. R. E. (2009) · International Journal of Molecular Sciences · doi:10.3390/ijms10020441 · Cited by 511
Metadata
- Authors
- Tang, B., Cao, L., Xu, K., Zhuo, L., Ge, J., Li, Q., & Yu, L.
- Venue
- Chemistry – A European Journal
- Publisher
- Wiley
- Published
- 2008-04-09
- Volume
- 14
- Issue
- 12
- Pages
- 3637-3644
- ISSN
- 0947-6539 (ISSN-L)
- 1521-3765
- OpenAlex
- W2147691147
- Cited by
- 280
- References
- 36
- FWCI
- 10.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.