CoChat

Wearable Potentiometric Sensors Based on Commercial Carbon Fibres for Monitoring Sodium in Sweat

Parrilla, Marc, Ferré, Jordi, Guinovart, Tomàs, Andrade, Francisco J. · 2016 · Electroanalysis
Cited by 122

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

The use of commercial carbon fibres (CCF) to build wearable potentiometric sensors for the real‐time monitoring of sodium levels in sweat during exercise is presented. CCF are an attractive substrate for building wearable electrochemical sensors because of their good electrical conductivity, chemical inertness, flexibility and mechanical resilience. In the first part of this work, the analytical performance of these novel potentiometric ion‐selective electrodes made with CCFs is presented. Then, through the incorporation of a solid‐contact reference electrode, the development of a complete miniaturized potentiometric cell with a Nernstian response (59.2±0.6 mV/log [Na+], N=4) is obtained. Finally, the cell is integrated into a wearable patch and attached onto the skin of an athlete. The analytical characterization of the wearable patch shows a near‐Nernstian response (55.9±0.8 mV/log [Na+], N=3) for sodium levels from 10−3 M to 10−1 M in artificial sweat, well within the physiological range of interest. The device shows low noise levels and very good stability (−0.4±0.3 mV ⋅ h−1). To improve the usability of the sensor in real scenarios, a calibration‐free approach is also explored. This platform opens new and attractive avenues for the generation of meaningful personalized physiological information that could be applied – among many other fields – in sports, nutrition and healthcare.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/elan.201600070

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 122

Metadata

Authors
Parrilla, M., Ferré, J., Guinovart, T., & Andrade, F. J.
Venue
Electroanalysis
Publisher
Wiley
Published
2016-04-14
Volume
28
Issue
6
Pages
1267-1275
ISSN
  • 1040-0397 (ISSN-L)
  • 1521-4109
OpenAlex
W2340438937
Cited by
122
References
14
FWCI
8.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Wearable Potentiometric Sensors Based on Commercial Carbon Fibres for Monitoring Sodium in Sweat. https://app.cochat.ai/papers/10.1002/elan.201600070
The paper
Parrilla, M., Ferré, J., Guinovart, T., & Andrade, F. J. (2016). Wearable Potentiometric Sensors Based on Commercial Carbon Fibres for Monitoring Sodium in Sweat. Electroanalysis. https://doi.org/10.1002/elan.201600070

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.