The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
In vivo biocompatibility studies. I. The cage implant system and a biodegradable hydrogel
Abstract
A cage implant system has been utilized to examine the in vivo biocompatibility of a biodegradable hydrogel, poly(2‐hydroxy‐ethyl‐L‐glutamine) (PHEG). This system permits the quantitative determination of the components of the inflammatory exudate which surrounds the implanted polymer within the cage system. This system permits the serial examination of exudate components without sacrificing the animal. In addition, this system allows the subsequent removal of the polymer for surface and mechanical studies. Following implantation of the biodegradable hydrogel, quantitative and differential white cell counts of the exudates were determined over a 21‐day period. In addition, concomitant extracellular enzyme analyses for alkaline phosphatase, acid phosphatase, prostatic acid phosphatase, leucine aminopeptidase, and Cathepsin B1 were determined. Corresponding control samples from exudates of the cage implant without the polymer were also determined. The two‐tailed Student's t‐test for unpaired samples was used to statistically compare the control and implanted polymer values for these respective analyses at the various time periods. A comparison of the cellular response for the control system and the PHEG system did not show statistically significant differences during the first 7 days following implantation. The acute inflammatory response, polymorphonuclear leukocyte predominant, was followed by a mild chronic inflammatory response, macrophage and lymphocyte predominant, and during this time period, 8–14 days, macrophages were present in significantly larger numbers for the PHEG system when compared to the control values. Enzymic analysis of the exudates revealed statistically significant differences between control and PHEG values at time intervals where no differences were noted in cell density or population. These results are discussed in terms of cell‐polymer interactions leading to cellular activation and enhanced enzyme exocytosis by the inflammatory cells. Stress‐strain measurements on implanted PHEG samples showed that significant in vivo degradation had occurred during the acute inflammatory phase of the response, i.e., the first 7 days.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the cage implant allows for the examination of the inflammatory response to a substrate of interest over time.113”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [113]
Citations
Cites
Fundamentals of Clinical Chemistry.
(1977) · Annals of Internal Medicine · doi:10.7326/0003-4819-87-1-142_1 · Cited by 2,624
Determination of hydroxyproline
Stegemann, H., & Stalder, K. (1967) · Clinica Chimica Acta · doi:10.1016/0009-8981(67)90167-2 · Cited by 1,588
Craddock, P. R., Fehr, J. S., Dalmasso, A. P., Brighan, K. L., & Jacob, H. (1977) · Journal of Clinical Investigation · doi:10.1172/jci108710 · Cited by 992
Proteinases in mammalian cells and tissues
Kerr, M. (1978) · Biochemical Education · doi:10.1016/0307-4412(78)90169-3 · Cited by 922
Goldbarg, J. A., & Rutenburg, A. M. (1958) · Cancer · doi:10.1002/1097-0142(195803/04)11:2 · Cited by 793
SECRETION OF PLASMINOGEN ACTIVATOR BY STIMULATED MACROPHAGES
Unkeless, J. C., Gordon, S., & Reich, E. (1974) · The Journal of Experimental Medicine · doi:10.1084/jem.139.4.834 · Cited by 712
Release of Inflammatory Mediators from Stimulated Neutrophils
Bleich, H. L., Moore, M. J., Weissmann, G., Smolen, J. E., & Korchak, H. M. (1980) · New England Journal of Medicine · doi:10.1056/nejm198007033030109 · Cited by 654
Henson, P. M. (1971) · PubMed · Cited by 514
The Immunologic Release of Constituents from Neutrophil Leukocytes
Henson, P. M. (1971) · The Journal of Immunology · doi:10.4049/jimmunol.107.6.1535 · Cited by 347
Complement activation and neutropenia occurring during cardiopulmonary bypass
Hammerschmidt, D. E., Stroncek, D. F., Bowers, T. K., Lammi‐Keefe, C. J., Kurth, D. M., Ozalins, A., Nicoloff, D. M., Lillehei, R. C., Craddock, P. R., & Jacob, H. S. (1981) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)37600-7 · Cited by 316
Research works printed but not linked: 10
- Salthouse T. N., 1981, Fundame Aspects of Biocompatibility, 233
- Salthouse T. N., 1976, Quantitative Enzyme Histochemistry in the Evaluation of Tissue Compatibility of Polymers for Surgical Implantation, Ann. Histochim., 21, 105
- Ritzmann S. E., 1975, Serum Proteinormalities, 4
- Ritzmann S. E., Serum Protein Abnormalities, 5
- Wilhelm D. L., 1977, Pathology, 25
- Taussig M. J., 1979, Processes in Pathology
- Chuang H. Y. K., 1981, Devices and Techgy Branch Contractors Meeting Program, 112
- Herzlinger G., 1980, Devices and Technology Branch Contractors Meeting Proceedings, 215
- Fehr J., 1975, Complement (C') Mediated Granulocyte (PMN) and Pulmonary Dysfunction During Nylon Fiber Leukapheresis, Clin. Res., 23, 522A
- Henson P. M., 1980, Mechanisms of Exocytosis in Phagocytic Inflammatory Cells, Am. J. Pathol., 101, 494
Cited by
Sorted by citations
Biological Responses to Materials
Anderson, J. M. (2001) · Annual Review of Materials Research · doi:10.1146/annurev.matsci.31.1.81 · Cited by 1,465
Self-citationSanterre, J. P., Woodhouse, K., Laroche, G., & Labow, R. S. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.05.079 · Cited by 718
Extracellular matrix-based biomaterial scaffolds and the host response
Aamodt, J. M., & Grainger, D. W. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.02.003 · Cited by 509
Fibrin(ogen) mediates acute inflammatory responses to biomaterials.
Tang, L., & Eaton, J. W. (1993) · The Journal of Experimental Medicine · doi:10.1084/jem.178.6.2147 · Cited by 451
Advances in Regenerative Medicine and Tissue Engineering: Innovation and Transformation of Medicine
Dzobo, K., Thomford, N. E., Senthebane, D. A., Shipanga, H., Rowe, A., Dandara, C., Pillay, M., & Motaung, K. S. (2018) · Stem Cells International · doi:10.1155/2018/2495848 · Cited by 477
Onuki, Y., Bhardwaj, U., Papadimitrakopoulos, F., & Burgess, D. J. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200610 · Cited by 423
Biomaterial biocompatibility and the macrophage
Anderson, J. M., & Miller, K. M. (1984) · Biomaterials · doi:10.1016/0142-9612(84)90060-7 · Cited by 403
Self-citationBiological responses to physicochemical properties of biomaterial surface
Rahmati, M., Silva, E. A., Reseland, J. E., Heyward, C. A., & Haugen, H. J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00103a · Cited by 409
Characterization of topographical effects on macrophage behavior in a foreign body response model
Chen, S., Jones, J. A., Xu, Y., Low, H.-Y., Anderson, J. M., & Leong, K. W. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.074 · Cited by 389
Self-citationIn vitro and in vivo interactions of cells with biomaterials
Ziats, N. P., Miller, K. M., & Anderson, J. (1988) · Biomaterials · doi:10.1016/0142-9612(88)90063-4 · Cited by 351
Self-citationBiocompatible Materials for Continuous Glucose Monitoring Devices
Nichols, S. P., Koh, A., Storm, W. L., Shin, J. H., & Schoenfisch, M. H. (2013) · Chemical Reviews · doi:10.1021/cr300387j · Cited by 347
Chapter 4 Mechanisms of inflammation and infection with implanted devices
Anderson, J. M. (1993) · Cardiovascular Pathology · doi:10.1016/1054-8807(93)90045-4 · Cited by 335
Self-citationKey players in the immune response to biomaterial scaffolds for regenerative medicine
Chung, L., Maestas, D. R., Housseau, F., & Elisseeff, J. H. (2017) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2017.07.006 · Cited by 333
Design, clinical translation and immunological response of biomaterials in regenerative medicine
Sadtler, K., Singh, A., Wolf, M. T., Wang, X., Pardoll, D. M., & Elisseeff, J. H. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.40 · Cited by 332
Tissue-biomaterial interactions
Williams, D. F. (1987) · Journal of Materials Science · doi:10.1007/bf01161439 · Cited by 317
Rapid printing of bio-inspired 3D tissue constructs for skin regeneration
Zhou, F., Hong, Y., Liang, R., Zhang, X., Liao, Y., Jiang, D., Zhang, J., Sheng, Z., Xie, C., Peng, Z., et al. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.120287 · Cited by 288
Pinchuk, L. (1995) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856294x00347 · Cited by 252
Biomaterial adherent macrophage apoptosis is increased by hydrophilic and anionic substrates in vivo
Brodbeck, W. G., Patel, J., Voskerician, G., Christenson, E., Shive, M. S., Nakayama, Y., Matsuda, T., Ziats, N. P., & Anderson, J. M. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.162124199 · Cited by 245
Self-citationBioabsorption of polylactides with different molecular properties
Nakamura, T., Hitomï, S., Watanabe, S., Shimizu, Y., Jamshidi, K., Hyon, S. H., & Ikada, Y. (1989) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820231003 · Cited by 244
Browning, M. B., Cereceres, S. N., Luong, P. T., & Cosgriff-Hernandez, E. M. (2014) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35096 · Cited by 133
Shin, H., Ruhé, P. Q., Mikos, A. G., & Jansen, J. A. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00168-6 · Cited by 204
Poly(carbonate urethane) and poly(ether urethane) biodegradation: In vivo studies
Christenson, E. M., Dadsetan, M., Wiggins, M., Anderson, J. M., & Hiltner, A. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30002 · Cited by 185
Self-citationIn vivo leukocyte cytokine mRNA responses to biomaterials are dependent on surface chemistry
Brodbeck, W. G., Voskerician, G., Ziats, N. P., Nakayama, Y., Matsuda, T., & Anderson, J. M. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10425 · Cited by 181
Self-citationKoschwanez, H. E., & Reichert, W. M. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.034 · Cited by 181
Chung, L., Maestas, D. R., Lebid, A., Mageau, A., Rosson, G. D., Wu, X., Wolf, M. T., Tam, A. J., Vanderzee, I., Wang, X., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aax3799 · Cited by 175
Biodegradation of a polyurethane in vitro
Phua, S. K., Castillo, E. J., Anderson, J. M., & Hiltner, A. (1987) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820210207 · Cited by 172
Self-citationRole for interleukin‐4 in foreign‐body giant cell formation on a poly(etherurethane urea) in vivo
Kao, W. J., McNally, A. K., Hiltner, A., & Anderson, J. M. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820291014 · Cited by 154
Self-citationHorbett, T. A. (1984) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1661052 · Cited by 158
Hyperbranched polyglycerol electrospun nanofibers for wound dressing applications
Vargas, E. A. T., Baracho, N. C. D. V., de Brito, J., & de Queiroz, Á. A. A. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.09.018 · Cited by 157
Implantable enzyme amperometric biosensors
Kotanen, C. N., Moussy, F. G., Carrara, S., & Guiseppi‐Elie, A. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.03.016 · Cited by 162
Cellular interactions with biomaterials: In vivo cracking of pre‐stressed pellethane 2363‐80A
Zhao, Q., Agger, M. P., Fitzpatrick, M. N., Anderson, J. M., Hiltner, A., Stokes, K., & Urbanski, P. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240508 · Cited by 145
Self-citationHydrophilic-hydrophobic copolymers as cell substrates: Effect on 3T3 cell growth rates
Horbett, T. A., Schway, M. B., & Ratner, B. D. (1985) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(85)90006-2 · Cited by 143
Biocompatibility Evolves: Phenomenology to Toxicology to Regeneration
Crawford, L., Wyatt, M., Bryers, J. D., & Ratner, B. D. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202002153 · Cited by 141
In vivo biocompatibility of collagenpoly(hydroxyethyl methacrylate) hydrogels
Jeyanthi, R., & Rao, K. P. (1990) · Biomaterials · doi:10.1016/0142-9612(90)90004-a · Cited by 130
Fibrinogen adsorption and host tissue responses to plasma functionalized surfaces
Tang, L., Wu, Y., & Timmons, R. B. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199810)42:1 · Cited by 127
Lindner, E., Coșofreţ, V. V., Ufer, S., Buck, R. P., Kao, W. J., Neuman, M. R., & Anderson, J. M. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820280509 · Cited by 120
Self-citationOxidative biodegradation mechanisms of biaxially strained poly(etherurethane urea) elastomers
Schubert, M. A., Wiggins, M. J., Schaefer, M. P., Hiltner, A., & Anderson, J. M. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820290309 · Cited by 120
Self-citationIn vivo biocompatibility studies. V. In vivo leukocyte interactions with biomer
Marchant, R. E., Miller, K. M., & Anderson, J. M. (1984) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820180917 · Cited by 117
Self-citationMesh Implants in Hernia Repair
Rosch, R., Junge, K., Schachtrupp, A., Klinge, U., Klosterhalfen, B., & Schumpelick, V. (2003) · European Surgical Research · doi:10.1159/000070045 · Cited by 116
Biodegradation and in vivo biocompatibility of rosin: a natural film-forming polymer
Satturwar, P. M., Fulzele, S. V., & Dorle, A. K. (2003) · AAPS PharmSciTech · doi:10.1208/pt040455 · Cited by 115
Injectable Lipid-Based Depot Formulations: Where Do We Stand?
Rahnfeld, L., & Luciani, P. (2020) · Pharmaceutics · doi:10.3390/pharmaceutics12060567 · Cited by 116
Emerging Fabrication Strategies of Hydrogels and Its Applications
Ali, F., Khan, I., Chen, J., Akhtar, K., Bakhsh, E. M., & Khan, S. B. (2022) · Gels · doi:10.3390/gels8040205 · Cited by 124
Parenteral depot-systems on the basis of biodegradable polyesters
Kissel, T., Brich, Z., Bantle, S., Lancranjan, I., Nimmerfall, F., & Vit, P. (1991) · Journal of Controlled Release · doi:10.1016/0168-3659(91)90028-c · Cited by 110
Tang, Y. W., Labow, R. S., & Santerre, J. P. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00563-x · Cited by 109
Li, Y., Meng, H., Liu, Y., Narkar, A. R., & Lee, B. P. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b01364 · Cited by 103
In vivo cytokine-associated responses to biomaterials
Schutte, R. J., Xie, L., Klitzman, B., & Reichert, W. M. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.09.026 · Cited by 111
T lymphocytes as critical mediators in tissue regeneration, fibrosis, and the foreign body response
Adusei, K. M., Ngo, T. B., & Sadtler, K. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2021.04.023 · Cited by 102
The Biocompatibility of Implant Materials
Ratner, B. D. (2015) · Elsevier eBooks · doi:10.1016/b978-0-12-800196-7.00003-7 · Cited by 88
Sadtler, K., Allen, B. W., Estrellas, K. M., Housseau, F., Pardoll, D. M., & Elisseeff, J. H. (2016) · Tissue Engineering Part A · doi:10.1089/ten.tea.2016.0304 · Cited by 89
Kao, W. J., Zhao, Q. H., Hiltner, A., & Anderson, J. M. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820280110 · Cited by 85
Self-citationMiller, K. M., Rose‐Caprara, V., & Anderson, J. M. (1989) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820230904 · Cited by 84
Self-citationBiocompatibility of polyhydroxybutyrate microspheres: in vitro and in vivo evaluation
Shishatskaya, E. I., Voinova, O. N., Goreva Anastasya, V., Mogilnaya, O. A., & Volova, T. G. (2008) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-007-3345-6 · Cited by 81
In vivo biocompatibility and biodegradation of poly(ethylene carbonate)
Dadsetan, M., Christenson, E. M., Unger, F. T., Ausborn, M., Kissel, T., Hiltner, A., & Anderson, J. M. (2003) · Journal of Controlled Release · doi:10.1016/j.jconrel.2003.08.010 · Cited by 79
Self-citationSustained release veterinary parenteral products
Medlicott, N. J., Waldron, N. A., & Foster, T. P. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2004.02.005 · Cited by 70
Ma, P. X., Zhang, R., Xiao, G., & Franceschi, R. T. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200102)54:2 · Cited by 429
Biostability and macrophage‐mediated foreign body reaction of silicone‐modified polyurethanes
Christenson, E. M., Dadsetan, M., Anderson, J. M., & Hiltner, A. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30317 · Cited by 68
Self-citationHost Factors Predisposing to and Influencing Therapy of Foreign Body Infections
Vaudaux, P. E., François, P., Lew, D. P., & Waldvogel, F. A. (2014) · ASM Press eBooks · doi:10.1128/9781555818067.ch1 · Cited by 66
Petillo, O., Peluso, G., Ambrosio, L., Nicolais, L., Kao, W. J., & Anderson, J. M. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820280514 · Cited by 65
Self-citationAntioxidant inhibition of poly(carbonate urethane) in vivo biodegradation
Christenson, E. M., Anderson, J. M., & Hiltner, A. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30506 · Cited by 64
Self-citationMacEwan, M. R., Brodbeck, W. G., Matsuda, T., & Anderson, J. M. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30316 · Cited by 63
Self-citationNeutrophil survival on biomaterials is determined by surface topography
Chang, S., Popowich, Y., Greco, R. S., & Haimovich, B. (2003) · Journal of Vascular Surgery · doi:10.1067/mva.2003.160 · Cited by 63
Blood and tissue compatibility of modified polyester: Thrombosis, inflammation, and healing
Chinn, J. A., Sauter, J., Phillips, R. E., Kao, W. J., Anderson, J. M., Hanson, S. R., & Ashton, T. R. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19980101)39:1 · Cited by 63
Self-citationHost Reaction against Empty Alginate-polylysine Microcapsules. Influence of Preparation Procedure
Vandenbossche, G. M. R., Bracke, M., Cuvelier, C. A., Bortier, H. E., Mareel, M. M. K., & Remon, J. (1993) · Journal of Pharmacy and Pharmacology · doi:10.1111/j.2042-7158.1993.tb03694.x · Cited by 62
Biomedical Applications of Synthetic Polymers
Ratner, B. D. (1989) · Elsevier eBooks · doi:10.1016/b978-0-08-096701-1.00210-x · Cited by 65
Marchant, R. E., Anderson, J., & Dillingham, E. O. (1986) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820200105 · Cited by 60
Self-citationEffect of some additives on the biostability of a poly(etherurethane) elastomer
Wu, Y. X., Zhao, Q., Anderson, J. M., Hiltner, A., Lodoen, G. A., & Payet, C. R. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250604 · Cited by 61
Self-citationBiocompatibility of poly (DL-lactic acid/glycine) copolymers
Schakenraad, J. M., & Dijkstra, P. J. (1991) · Clinical Materials · doi:10.1016/0267-6605(91)90067-p · Cited by 54
Li, Z., Yang, X., Wu, L., Chen, Z., Lin, Y., Xu, K., & Chen, G. (2009) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856209x452944 · Cited by 53
Kim, J., Dadsetan, M., Ameenuddin, S., Windebank, A. J., Yaszemski, M. J., & Lu, L. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32810 · Cited by 53
Kao, W. J., Hiltner, A., Anderson, J. M., & Lodoen, G. A. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820280709 · Cited by 54
Self-citationPierre, T. S., & Chiellini, E. (1987) · Journal of Bioactive and Compatible Polymers · doi:10.1177/088391158700200101 · Cited by 51
Zhao, Q. H., Anderson, J. M., Hiltner, A., Lodoen, G. A., & Payet, C. R. (1992) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820260805 · Cited by 50
Self-citationSynthetic nano-scale fibrous extracellular matrix
Ma, P. X., & Zhang, R. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199907)46:1 · Cited by 1,065
Self-citationPytela, J., Saudek, V., Drobnik, J., & Rypáček, F. (1989) · Journal of Controlled Release · doi:10.1016/0168-3659(89)90014-x · Cited by 48
Nagahara, S., & Matsuda, T. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199612)32:4 · Cited by 36
Self-citationMarchant, R. E., Anderson, J. M., Phua, K., & Hiltner, A. (1984) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820180307 · Cited by 47
Self-citationDefensins Impair Phagocytic Killing by Neutrophils in Biomaterial-Related Infection
Kaplan, S. S., Heine, R. P., & Simmons, R. L. (1999) · Infection and Immunity · doi:10.1128/.67.4.1640-1645.1999 · Cited by 47
Miller, K. M., Huskey, R. A., Bigby, L. F., & Anderson, J. M. (1989) · Biomaterials · doi:10.1016/0142-9612(89)90023-9 · Cited by 54
Self-citationCoșofreţ, V. V., Erdösy, M., Buck, R. P., Kao, W. J., Anderson, J. M., Lindner, E., & Neuman, M. R. (1994) · The Analyst · doi:10.1039/an9941902283 · Cited by 46
Self-citationElectroanalytical and biocompatibility studies on microfabricated array sensors
Lindner, E., Coșofreţ, V. V., Buck, R. P., Johnson, T. A., Ash, R. B., Neuman, M. R., Kao, W. J., & Anderson, J. M. (1995) · Electroanalysis · doi:10.1002/elan.1140070913 · Cited by 45
Self-citationPolymere als Implantatwerkstoffe
Lendlein, A. (1999) · Chemie in unserer Zeit · doi:10.1002/ciuz.19990330505 · Cited by 44
McBane, J. E., Santerre, J. P., & Labow, R. S. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31263 · Cited by 42
Daugherty, A. L., Cleland, J. L., Duenas, E. T., & Mrsny, R. J. (1997) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/s0939-6411(97)00065-9 · Cited by 41
Peritoneal macrophage response: an in vivo model for the study of synthetic materials
Freyria, A. M., Chignier, E., Guidollet, J., & Louisot, P. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90187-f · Cited by 42
Coșofreţ, V. V., Erdösy, M., Lindner, E., Johnson, T. A., Buck, R. P., Kao, W. J., Neuman, M. R., & Anderson, J. M. (1994) · Analytical Letters · doi:10.1080/00032719408000310 · Cited by 41
Self-citationBiostability and biocompatibility of a surface-grafted phospholipid monolayer on a solid substrate
Kim, K., Kim, C., & Byun, Y. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00469-1 · Cited by 40
Expression of intercellular adhesion molecule-1 on macrophages in vitro as a marker of activation
Bernatchez, S. F., Atkinson, M. R., & Parks, P. J. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00072-0 · Cited by 39
Zignani, M., Merkli, A., Sintzel, M. B., Bernatchez, S. F., Kloeti, W., Heller, J., Tabatabay, C., & Gurny, R. (1997) · Journal of Controlled Release · doi:10.1016/s0168-3659(97)00050-3 · Cited by 38
Spilizewski, K. L., Marchant, R. E., Anderson, J. M., & Hiltner, A. (1987) · Biomaterials · doi:10.1016/0142-9612(87)90021-4 · Cited by 38
Self-citationPark, J. H., & Bae, Y. H. (2002) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10424 · Cited by 35
Biocompatibility study of as‐polymerized poly( L ‐lactide) in rats using a cage implant system
Bergsma, J. E., Rozema, F. R., Bos, R. R. M., Boering, G., de Bruijn, W. C., & Pennings, A. J. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820290206 · Cited by 35
Synthesis of microbial elastomers based on soybean oily acids. Biocompatibility studies
Hazer, D. B., Hazer, B., & Kaymaz, F. F. (2009) · Biomedical Materials · doi:10.1088/1748-6041/4/3/035011 · Cited by 37
Cellular reaction to the Vascugraft® polyesterurethane vascular prosthesis: in vivo studies in rats
Huang, B., Marois, Y., Roy, R., Julien, M., & Guidoin, R. (1992) · Biomaterials · doi:10.1016/0142-9612(92)90186-r · Cited by 34
Biocompatibility and Bioresponse to Biomaterials
Anderson, J. M. (2019) · Principles of Regenerative Medicine · doi:10.1016/b978-0-12-809880-6.00039-4 · Cited by 33
Self-citationSandor, M., Harris, J., & Mathiowitz, E. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00183-7 · Cited by 31
In vivo leucocyte interactions on Pellethane® surfaces
Brunstedt, M. R., Anderson, J. M., Spilizewski, K. L., Marchant, R. E., & Hiltner, A. (1990) · Biomaterials · doi:10.1016/0142-9612(90)90089-9 · Cited by 32
Self-citationHazer, D. B., & Hazer, B. (2010) · Journal of Polymer Research · doi:10.1007/s10965-010-9413-5 · Cited by 32
The biocompatibility of solution cast and acetone‐extracted cast biomer
Marchant, R. E., Anderson, J., Hiltner, A., Castillo, E. J., Gleit, J., & Ratner, B. D. (1986) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820200611 · Cited by 30
Self-citationDoty, A. C., Hirota, K., Olsen, K. F., Sakamoto, N., Ackermann, R., Feng, M. R., Wang, Y., Choi, S. H., Qu, W., Schwendeman, A. A., et al. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.07.041 · Cited by 30
A new biological glue from gelatin and poly (L-glutamic acid)
Otani, Y., Tabata, Y., & Ikada, Y. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199606)31:2 · Cited by 118
Metadata
- Authors
- Marchant, R., Hiltner, A., Hamlin, C., Rabinovitch, A., Slobodkin, R., & Anderson, J. M.
- Affiliations
- Case Western Reserve University (US)
- Corresponding author
- Anderson, James M.
- ORCID
- Anderson, James M.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1983-03
- Volume
- 17
- Issue
- 2
- Pages
- 301-325
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2128920830
- Cited by
- 181
- References
- 45
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 1 · 2022: 1 · 2021: 3 · 2020: 4 · 2018: 2 · 2017: 1 · 2016: 7 · 2015: 1 · 2014: 4 · 2013: 2 · 2012: 2
- FWCI
- 4.41
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Biomedical Materials Research (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Materials Science › Biomaterials › Hydrogels: synthesis, properties, applications
- Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
- Health Sciences › Medicine › Surgery › Wound Healing and Treatments
- Keywords
- biocompatibility, biodegradable hydrogels, inflammatory exudate, white blood cell count, macrophages, extracellular enzymes, alkaline phosphatase, acid phosphatase, prostatic acid phosphatase, leucine aminopeptidase, cathepsin B, in vivo degradation, stress-strain, cell-polymer interactions, chronic inflammation
- MeSH terms
- Acid Phosphatase, Alkaline Phosphatase, Animals, Biocompatible Materials, Biodegradation, Environmental, Blood Cell Count, Cell Adhesion, Chemotaxis, Extracellular Space, Exudates and Transudates, Inflammation, Neutrophils, Peptides, Proteins, Stainless Steel, Prostheses and Implants, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review