In vivo leukocyte cytokine mRNA responses to biomaterials are dependent on surface chemistry
Abstract
An in vivo mouse cage implant system was used to determine whether leukocyte cytokine mRNA responses to implanted biomaterials were dependent on surface chemistry. Surfaces displaying various chemistries (hydrophobic, hydrophilic, anionic, and cationic) were placed into stainless steel cages and implanted subcutaneously. Semiquantitative RT‐PCR analyses revealed that hydrophilic surfaces showed a decreased expression of proinflammatory cytokines, IL‐6 and IL‐8, and pro‐wound healing cytokines, IL‐10 and TGF‐β by adherent cells, and mRNA levels of the proinflammatory cytokine, IL‐1β, and the pro‐wound healing cytokine IL‐13 were decreased in surrounding, exudate cells. Cytokine responses by adherent and exudate cells to hydrophobic, anionic and cationic surfaces were similar and indicative of a strong inflammatory response at the earliest time point followed by a wound healing response at later time points. However, no differences in the types or levels of exudate cells for any of the surfaces or the empty cage at each of the respective time points were observed, indicating their respective biocompatibility. These studies identify hydrophilic surface chemistries as having significant effects on leukocyte cytokine responses in vivo by decreasing the expression of inflammatory and wound healing cytokines by inflammatory cells adherent to the biomaterial as well as present in the surrounding exudate. © 2002 Wiley Periodicals, Inc. J Biomed Mater Res 64A: 320–329, 2003
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Cytokine expression of biomaterial adherent macrophages in vivo was dependent on surface chemistry.
“Cytokine expression of biomaterial adherent macrophages in vivo was also found to be dependent on surface chemistry.[120]”
From Foreign body reaction to biomaterials (2008) · cites this paper as [120]
MΦ activation depends on biomaterial architecture in addition to previously implicated biomaterial chemistry and bioactivity.
“Here we find that MΦ activation depends on biomaterial architecture in addition to previously implicated biomaterial chemistry and bioactivity (34–36).”
From Proangiogenic scaffolds as functional templates for cardiac tissue engineering (2010) · cites this paper as [36]
Cites
Biological Responses to Materials
Anderson, J. M. (2001) · Annual Review of Materials Research · doi:10.1146/annurev.matsci.31.1.81 · Cited by 1,465 · see citing works
Self-citationSynthetic nano-scale fibrous extracellular matrix
Ma, P. X., & Zhang, R. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199907)46:1 · Cited by 1,055 · see citing works
Sutton, J. S., & WEISS, L. P. (1966) · The Journal of Cell Biology · doi:10.1083/jcb.28.2.303 · Cited by 447 · see citing works
In vitro and in vivo interactions of cells with biomaterials
Ziats, N. P., Miller, K. M., & Anderson, J. (1988) · Biomaterials · doi:10.1016/0142-9612(88)90063-4 · Cited by 351 · see citing works
Self-citationZhao, Q., Topham, N., Anderson, J. M., Hiltner, A., Lodoen, G., & Payet, C. R. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250205 · Cited by 318 · see citing works
Self-citationInterleukin 4 induces cultured monocytes/macrophages to form giant multinucleated cells.
McInnes, A., & Rennick, D. M. (1988) · The Journal of Experimental Medicine · doi:10.1084/jem.167.2.598 · Cited by 310 · see citing works
(1995) · Europe PMC (PubMed Central) · Cited by 294 · see citing works
Interleukin-13 induces human monocyte/macrophage fusion and macrophage mannose receptor expression
DeFife, K. M., Jenney, C. R., McNally, A. K., Colton, E., & Anderson, J. M. (1997) · The Journal of Immunology · doi:10.4049/jimmunol.158.7.3385 · Cited by 228 · see citing works
Self-citation<i>In vivo</i> biocompatibility studies. I. The cage implant system and a biodegradable hydrogel
Marchant, R., Hiltner, A., Hamlin, C., Rabinovitch, A., Slobodkin, R., & Anderson, J. M. (1983) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820170209 · Cited by 181 · see citing works
Self-citationNakayama, Y., & Matsuda, T. (1996) · Macromolecules · doi:10.1021/ma9606014 · Cited by 167 · see citing works
Self-citationKao, W. J., McNally, A. K., Hiltner, A., & Anderson, J. M. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820291014 · Cited by 154 · see citing works
Self-citationRecombinant human gamma-interferon induces human monocyte polykaryon formation.
Weinberg, J. B., Hobbs, M. M., & Misukonis, M. A. (1984) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.81.14.4554 · Cited by 133 · see citing works
Direct evidence that inflammatory multinucleate giant cells form by fusion
Murch, A. R., Grounds, M. D., Marshall, C. A., & Papadimitriou, J. M. (1982) · The Journal of Pathology · doi:10.1002/path.1711370302 · Cited by 107 · see citing works
Monocyte, macrophage and foreign body giant cell interactions with molecularly engineered surfaces
Anderson, J. M., Defife, K., Mcnally, A., collier, T., & jenney, C. (1999) · Journal of Materials Science: Materials in Medicine · doi:10.1023/a:1008976531592 · Cited by 100 · see citing works
Self-citationKreipe, H. H., Radzun, H., Rudolph, P., Barth, J., Hansmann, M. L., Heidorn, K., & Parwaresch, M. R. (1988) · Europe PMC (PubMed Central) · Cited by 90 · see citing works
DeFife, K. M., Colton, E., Nakayama, Y., Matsuda, T., & Anderson, J. M. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199905)45:2 · Cited by 76 · see citing works
Self-citationChang, J. R., Zaczyńska, E., Katsetos, C. D., Platsoucas, C. D., & Oleszak, E. L. (2000) · Virology · doi:10.1006/viro.2000.0646 · Cited by 62 · see citing works
Hassan, N. F., Kamani, N., Meszaros, M. M., & Douglas, S. D. (1989) · The Journal of Immunology · doi:10.4049/jimmunol.143.7.2179 · Cited by 59 · see citing works
Angiostatin generation by human tumor cell lines: Involvement of plasminogen activators
Westphal, J. R., Hullenaar, R. V., Geurts-Moespot, A. J., Sweep, F. C. G. J., Verheijen, J. H., Bussemakers, M. J. G., Askaa, J., Clemmensen, I. H., Eggermont, A. M. M., Ruiter, D. J., et al. (2000) · International Journal of Cancer · doi:10.1002/(sici)1097-0215(20000615)86:6 · Cited by 52 · see citing works
Interleukin-1 Receptor Antagonist Is Produced by Sertoli Cellsin Vitro1
Zeyse, D., Lunenfeld, E., Beck, M., et al. (2000) · Endocrinology · doi:10.1210/endo.141.4.7401 · Cited by 40 · see citing works
Biocompatibility study of as‐polymerized poly( L ‐lactide) in rats using a cage implant system
Bergsma, J. E., Rozema, F. R., Bos, R. R. M., Boering, G., de Bruijn, W. C., & Pennings, A. J. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820290206 · Cited by 35 · see citing works
Repeated Intratracheal Challenge with Particulate Antigen Modulates Murine Lung Cytokines
Todt, J. C., Sonstein, J., Polak, T., Seitzman, G. D., Hu, B., & Curtis, J. L. (2000) · The Journal of Immunology · doi:10.4049/jimmunol.164.8.4037 · Cited by 25 · see citing works
In vivo biocompatibility of catheter materials
Spilezewski, K. L., Anderson, J. M., Schaap, R. N., & Solomon, D. D. (1988) · Biomaterials · doi:10.1016/0142-9612(88)90093-2 · Cited by 19 · see citing works
Self-citationInterleukin-1 Receptor Antagonist Is Produced by Sertoli Cells in Vitro
Zeyse, D. (2000) · Endocrinology · doi:10.1210/en.141.4.1521 · Cited by 18 · see citing works
Effect of some additives on the biostability of a poly(etherurethane) elastomer
Wu, Y., Zhao, Q., Anderson, J. M., et al. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820251109 · Cited by 6 · see citing works
Self-citationJenney (2000) · doi:10.1002/(sici)1097-4636(20000315)49:4
Flagged first, then by citations
Cited by
Sorted by citations
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138 · see citing works
Self-citationProangiogenic scaffolds as functional templates for cardiac tissue engineering
Madden, L. R., Mortisen, D. J., Sussman, E. M., Dupras, S. K., Fugate, J. A., Cuy, J. L., Hauch, K. D., Laflamme, M. A., Murry, C. E., & Ratner, B. D. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1006442107 · Cited by 662 · see citing works
Biosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660 · see citing works
Sussman, E. M., Halpin, M. C., Muster, J., Moon, R. T., & Ratner, B. D. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-013-0933-0 · Cited by 416 · see citing works
Cellular and Molecular Dynamics in the Foreign Body Reaction
Luttikhuizen, D. T., Harmsen, M. C., & Luyn, M. J. A. V. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.1955 · Cited by 396 · see citing works
Characterization of topographical effects on macrophage behavior in a foreign body response model
Chen, S., Jones, J. A., Xu, Y., Low, H.-Y., Anderson, J. M., & Leong, K. W. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.074 · Cited by 389 · see citing works
Self-citationJones, J. A., Chang, D. T., Meyerson, H., Colton, E., Kwon, I. K., Matsuda, T., & Anderson, J. M. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31221 · Cited by 352 · see citing works
Self-citationBiocompatibility of implants: lymphocyte/macrophage interactions
Anderson, J. M., & McNally, A. K. (2011) · Seminars in Immunopathology · doi:10.1007/s00281-011-0244-1 · Cited by 226 · see citing works
Self-citationDailey, L. A., Jekel, N., Fink, L., Gessler, T., Schmehl, T., Wittmar, M., Kissel, T., & Seeger, W. (2006) · Toxicology and Applied Pharmacology · doi:10.1016/j.taap.2006.01.016 · Cited by 220 · see citing works
Macrophage and dendritic cell phenotypic diversity in the context of biomaterials
Kou, P. M., & Babensee, J. E. (2011) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32971 · Cited by 190 · see citing works
Bota, P. C. S., Collie, A. M. B., Puolakkainen, P., Vernon, R. B., Sage, E. H., Ratner, B. D., & Stayton, P. S. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32893 · Cited by 186 · see citing works
Schutte, R. J., Parisi‐Amon, A., & Reichert, W. M. (2009) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31863 · Cited by 161 · see citing works
Lymphocytes and the foreign body response: lymphocyte enhancement of macrophage adhesion and fusion
Brodbeck, W. G., MacEwan, M., Colton, E., Meyerson, H., & Anderson, J. M. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30313 · Cited by 146 · see citing works
Self-citationQuantitative <i>in vivo</i> cytokine analysis at synthetic biomaterial implant sites
Rodriguez, A., Meyerson, H., & Anderson, J. M. (2009) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31939 · Cited by 111 · see citing works
Self-citationModulus-dependent macrophage adhesion and behavior
Irwin, E. F., Saha, K., Rosenbluth, M., Gamble, L. J., Castner, D. G., & Healy, K. E. (2008) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856208786052407 · Cited by 105 · see citing works
Mediation of <i>in vivo</i> glucose sensor inflammatory response via nitric oxide release
Gifford, R., Batchelor, M. M., Lee, Y., Gokulrangan, G., Meyerhoff, M. E., & Wilson, G. S. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30359 · Cited by 96 · see citing works
Temporal progression of the host response to implanted poly(ethylene glycol)‐based hydrogels
Lynn, A. D., Blakney, A. K., Kyriakides, T. R., & Bryant, S. J. (2011) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.33015 · Cited by 77 · see citing works
McBane, J. E., Matheson, L. A., Sharifpoor, S., Santerre, J. P., & Labow, R. S. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.07.010 · Cited by 63 · see citing works
In Vivo Evaluation of the Biocompatibility of Biomaterial Device
Frazão, L. P., Vieira de Castro, J., & Neves, N. M. (2020) · Advances in Experimental Medicine and Biology · doi:10.1007/978-981-15-3262-7_8 · Cited by 23 · see citing works
- Authors
- Brodbeck, W. G., Voskerician, G., Ziats, N. P., Nakayama, Y., Matsuda, T., & Anderson, J. M.
- Affiliations
- Case Western Reserve University (US)
- National Cerebral and Cardiovascular Center (JP)
- Kyushu University (JP)
- Corresponding author
- Anderson, James M.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2002-12-31
- Volume
- 64A
- Issue
- 2
- Pages
- 320-329
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2101726477
- Cited by
- 181
- References
- 27
- Citations by year
- 2026: 3 · 2025: 5 · 2024: 2 · 2023: 4 · 2022: 1 · 2021: 2 · 2020: 6 · 2019: 8 · 2018: 7 · 2017: 7 · 2016: 6 · 2015: 10 · 2014: 12 · 2013: 10 · 2012: 12
- FWCI
- 3.31
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Biomedical Materials Research Part A (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Heart, Lung, and Blood Institute (HL55714, R01HL055714, HL 33849)
- National Institute of General Medical Sciences (GM-20380, F32GM020380)
- Topics
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Health Sciences › Medicine › Rehabilitation › Wound Healing and Treatments
- Keywords
- hydrophilic surfaces, hydrophobic surfaces, anionic surfaces, cationic surfaces, inflammatory cytokines, interleukin-6, interleukin-8, IL-10, TGF-beta, IL-1β, IL-13, subcutaneous implantation, biocompatibility, adherent cells
- MeSH terms
- Animals, Biocompatible Materials, Cell Adhesion, Cell Fusion, Exudates and Transudates, Leukocytes, Materials Testing, RNA, Messenger, Surface Properties, Cytokines, Reverse Transcriptase Polymerase Chain Reaction, Mice
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review