Imaging of diffusion and microcirculation with gradient sensitization: Design, strategy, and significance
Open accessThe DOI matches its Crossref record; 75 of the 75 references it cites were found in a registry or an index.
Abstract
Recent developments in the use of magnetic resonance (MR) to measure and image diffusion and blood microcirculation (“perfusion”) are summarized. After a brief description of the effects of diffusion and perfusion on the MR signal, the different methods (conventional spin‐echo, stimulated‐echo, gradient‐echo, and echo‐planar imaging) that have been proposed and used to image and measure diffusion and perfusion by gradient sensitization are presented, along with their advantages and limitations. The difficulties of diffusion/ perfusion imaging related to both hardware and software are then discussed. Special attention is given to specific problems encountered with in vivo studies and data analysis. Finally, the potential biologic and clinical applications are outlined, and some examples are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Algorithm for Least-Squares Estimation of Nonlinear Parameters
Marquardt, D. W. (1963) · Journal of the Society for Industrial and Applied Mathematics · doi:10.1137/0111030 · Cited by 30,728
Data Reduction and Error Analysis for the Physical Sciences
Bevington, P. R., Robinson, D. K., Blair, J. M., Mallinckrodt, A. J., & McKay, S. (1993) · Computers in Physics · doi:10.1063/1.4823194 · Cited by 14,824
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Carr, H. Y., & Purcell, E. M. (1954) · Physical Review · doi:10.1103/physrev.94.630 · Cited by 6,466
Hahn, E. L. (1950) · Physical Review · doi:10.1103/physrev.80.580 · Cited by 5,085
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging.
Le Bihan, D., Breton, E., Lallemand, D., Aubin, M. L., Vignaud, J., & Laval-Jeantet, M. (1988) · Radiology · doi:10.1148/radiology.168.2.3393671 · Cited by 3,169
Self-citationSimulation and the Monte Carlo Method
Rubinstein, R. Y. (1981) · Wiley series in probability and statistics · doi:10.1002/9780470316511 · Cited by 2,450
Multi-planar image formation using NMR spin echoes
Mansfield, P. (1977) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/10/3/004 · Cited by 1,813
Self-diffusion in normal and heavy water in the range 1-45.deg.
Mills, R. (1973) · The Journal of Physical Chemistry · doi:10.1021/j100624a025 · Cited by 1,706
Cited by
Diffusion-Weighted MRI in the Body: Applications and Challenges in Oncology
Koh, D.-M., & Collins, D. J. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1403 · Cited by 1,993
Bozzali, M. (2002) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.72.6.742 · Cited by 568
Head and Neck Lesions: Characterization with Diffusion-weighted Echo-planar MR Imaging
Wang, J., Takashima, S., Takayama, F., Kawakami, S., Saito, A., Matsushita, T., Momose, M., & Ishiyama, T. (2001) · Radiology · doi:10.1148/radiol.2202010063 · Cited by 566
Diffusion tensor magnetic resonance imaging in multiple sclerosis
Filippi, M., Cercignani, M., Inglese, M., Horsfield, M. A., & Comi, G. (2001) · Neurology · doi:10.1212/wnl.56.3.304 · Cited by 546
Intravoxel Incoherent Motion in Body Diffusion-Weighted MRI: Reality and Challenges
Koh, D.-M., Collins, D. J., & Orton, M. R. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.10.5515 · Cited by 527
Theoretical Model for Water Diffusion in Tissues
Szafer, A., Zhong, J., & Gore, J. C. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330516 · Cited by 521
Benveniste, H., Hedlund, L. W., & Johnson, G. A. (1992) · Stroke · doi:10.1161/01.str.23.5.746 · Cited by 508
An analytical model of restricted diffusion in bovine optic nerve
Stanisz, G. J., Wright, G. A., Henkelman, R. M., & Szafer, A. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370115 · Cited by 501
In Vivo Measurement of Cortical Impedance Spectrum in Monkeys: Implications for Signal Propagation
Logothetis, N. K., Kayser, C., & Oeltermann, A. (2007) · Neuron · doi:10.1016/j.neuron.2007.07.027 · Cited by 453
Alexander, A. L., Hurley, S. A., Samsonov, A. A., Adluru, N., Hosseinbor, A. P., Mossahebi, P., Tromp, D. P. M., Zakszewski, E., & Field, A. S. (2011) · Brain Connectivity · doi:10.1089/brain.2011.0071 · Cited by 449
Magnetic resonance myocardial fiber-orientation mapping with direct histological correlation
Hsu, E. W., Muzikant, A. L., Matulevicius, S. A., Penland, R. C., & Henriquez, C. S. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.274.5.h1627 · Cited by 386
MR imaging of high-grade cerebral gliomas: value of diffusion-weighted echoplanar pulse sequences.
Tien, R. D., Felsberg, G. J., Friedman, H., Brown, M., & MacFall, J. (1994) · American Journal of Roentgenology · doi:10.2214/ajr.162.3.8109520 · Cited by 368
Cercignani, M. (2001) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.70.3.311 · Cited by 291
Andreou, A., Koh, D. M., Collins, D. J., Blackledge, M., Wallace, T., Leach, M. O., & Orton, M. R. (2013) · European Radiology · doi:10.1007/s00330-012-2604-1 · Cited by 287
Diffusion‐weighted interleaved echo‐planar imaging with a pair of orthogonal navigator echoes
Butts, K., de Crespigny, A., Pauly, J. M., & Moseley, M. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350518 · Cited by 244
Spinal cord MRI in multiple sclerosis—diagnostic, prognostic and clinical value
Kearney, H., Miller, D. H., & Ciccarelli, O. (2015) · Nature Reviews Neurology · doi:10.1038/nrneurol.2015.80 · Cited by 235
Diffusion-weighted MRI differentiates the Parkinson variant of multiple system atrophy from PD
Schocke, M. F. H., Seppi, K., Esterhammer, R., Kremser, C., Jaschke, W., Poewe, W., & Wenning, G. K. (2002) · Neurology · doi:10.1212/wnl.58.4.575 · Cited by 233
Mintorovitch, J., Yang, G. Y., Shimizu, H., Kucharczyk, J., Chan, P. H., & Weinstein, P. R. (1994) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1994.40 · Cited by 211
Transient decrease in water diffusion observed in human occipital cortex during visual stimulation
Darquié, A., Poline, J.-B., Poupon, C., Saint-Jalmes, H., & Le Bihan, D. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.151125698 · Cited by 194
Normal Brain and Brain Tumor: Multicomponent Apparent Diffusion Coefficient Line Scan Imaging
Maier, S. E., Bogner, P., Bajzik, G., Mamata, H., Mamata, Y., Repa, I., Jolesz, F. A., & Mulkern, R. V. (2001) · Radiology · doi:10.1148/radiology.219.3.r01jn02842 · Cited by 158
Katayama, M., Masui, T., Kobayashi, S., Ito, T., Sakahara, H., Nozaki, A., & Kabasawa, H. (2002) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200203000-00015 · Cited by 103
“In our study, the cystic components that exhibited typical watery intensity on T1- and T2-weighted images had similar mean ADCs, ranging from 1.54 to 1.84 × 10−3 mm2 /s, while it has been reported that the expected ADC of H2O in the phantom at body temperature is 3.24 × 10−3 mm2 /s (15).”
BackgroundInfluential
Metadata
- Authors
- Le Bihan, D., Turner, R., Moonen, C. T. W., & Pekar, J.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 1991-01
- Volume
- 1
- Issue
- 1
- Pages
- 7-28
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2122145999
- Cited by
- 288
- References
- 75
- FWCI
- 9.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.