The DOI matches its Crossref record; 75 of the 75 references it cites were found in a registry or an index.
Imaging of diffusion and microcirculation with gradient sensitization: Design, strategy, and significance
Open accessAbstract
Recent developments in the use of magnetic resonance (MR) to measure and image diffusion and blood microcirculation (“perfusion”) are summarized. After a brief description of the effects of diffusion and perfusion on the MR signal, the different methods (conventional spin‐echo, stimulated‐echo, gradient‐echo, and echo‐planar imaging) that have been proposed and used to image and measure diffusion and perfusion by gradient sensitization are presented, along with their advantages and limitations. The difficulties of diffusion/ perfusion imaging related to both hardware and software are then discussed. Special attention is given to specific problems encountered with in vivo studies and data analysis. Finally, the potential biologic and clinical applications are outlined, and some examples are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Algorithm for Least-Squares Estimation of Nonlinear Parameters
Marquardt, D. W. (1963) · Journal of the Society for Industrial and Applied Mathematics · doi:10.1137/0111030 · Cited by 30,728
Data Reduction and Error Analysis for the Physical Sciences
Bevington, P. R., Robinson, D. K., Blair, J. M., Mallinckrodt, A. J., & McKay, S. (1993) · Computers in Physics · doi:10.1063/1.4823194 · Cited by 14,824
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Carr, H. Y., & Purcell, E. M. (1954) · Physical Review · doi:10.1103/physrev.94.630 · Cited by 6,466
Hahn, E. L. (1950) · Physical Review · doi:10.1103/physrev.80.580 · Cited by 5,085
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging.
Le Bihan, D., Breton, E., Lallemand, D., Aubin, M. L., Vignaud, J., & Laval-Jeantet, M. (1988) · Radiology · doi:10.1148/radiology.168.2.3393671 · Cited by 3,169
Self-citationSimulation and the Monte Carlo Method
Rubinstein, R. Y. (1981) · Wiley series in probability and statistics · doi:10.1002/9780470316511 · Cited by 2,450
Multi-planar image formation using NMR spin echoes
Mansfield, P. (1977) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/10/3/004 · Cited by 1,813
Self-diffusion in normal and heavy water in the range 1-45.deg.
Mills, R. (1973) · The Journal of Physical Chemistry · doi:10.1021/j100624a025 · Cited by 1,706
Use of the Stimulated Echo in NMR Diffusion Studies
Tanner, J. E. (1970) · The Journal of Chemical Physics · doi:10.1063/1.1673336 · Cited by 1,645
Importance of classical diffusion in NMR studies of water in biological cells
Brownstein, K. R., & Tarr, C. E. (1979) · Physical Review A · doi:10.1103/physreva.19.2446 · Cited by 1,422
Diffusion in Solids, Liquids, Gases
Jost, W. (1952) · Zeitschrift für Physikalische Chemie · doi:10.1515/zpch-1952-2011-229 · Cited by 1,270
Bottomley, P. A., Foster, T. H., Argersinger, R. E., & Pfeifer, L. M. (1984) · Medical Physics · doi:10.1118/1.595535 · Cited by 1,192
Diffusion-weighted MR imaging of anisotropic water diffusion in cat central nervous system.
Moseley, M. E., Cohen, Y., Kucharczyk, J., Mintorovitch, J., Asgari, H. S., Wendland, M. F., Tsuruda, J., & Norman, D. (1990) · Radiology · doi:10.1148/radiology.176.2.2367658 · Cited by 1,133
Stejskal, E. O. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1696526 · Cited by 894
(2024) · American Journal of Neuroradiology · doi:10.3174/ajnr.45-12.s8 · Cited by 890
Restricted Self-Diffusion of Protons in Colloidal Systems by the Pulsed-Gradient, Spin-Echo Method
Tanner, J. E., & Stejskal, E. O. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670306 · Cited by 867
An efficient, highly homogeneous radiofrequency coil for whole-body NMR imaging at 1.5 T
Hayes, C. E., Edelstein, W. A., Schenck, J. F., et al. (1985) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(85)90257-4 · Cited by 766
Snapshot flash mri. applications to t1, t2, and chemical‐shift imaging
Haase, A. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130109 · Cited by 693
Echo-planar imaging of intravoxel incoherent motion.
Turner, R., Le Bihan, D., Maier, J., Vavrek, R., Hedges, L. K., & Pekar, J. (1990) · Radiology · doi:10.1148/radiology.177.2.2217777 · Cited by 581
Self-citationMeasurement of Flow with NMR Imaging Using a Gradient Pulse and Phase Difference Technique
Bryant, D. J., Payne, J. A., Firmin, D. N., & Longmore, D. B. (1984) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198408000-00002 · Cited by 545
Anisotropic diffusion in human white matter: demonstration with MR techniques in vivo.
Chenevert, T. L., Brunberg, J. A., & Pipe, J. G. (1990) · Radiology · doi:10.1148/radiology.177.2.2217776 · Cited by 503
Temperature mapping with MR imaging of molecular diffusion: application to hyperthermia.
Le Bihan, D., Delannoy, J., & Levin, R. L. (1989) · Radiology · doi:10.1148/radiology.171.3.2717764 · Cited by 493
Self-citationHahn, G. M. (1982) · Springer eBooks · doi:10.1007/978-1-4684-4193-2 · Cited by 476
Diffusion and Nuclear Spin Relaxation in Water
Simpson, J. H., & Carr, H. Y. (1958) · Physical Review · doi:10.1103/physrev.111.1201 · Cited by 444
Water movement through lipid bilayers, pores, and plasma membranes : theory and reality
Finkelstein, A. (1987) · Cited by 431
Gillette, E. L., & Hahn, G. M. (1983) · Radiation Research · doi:10.2307/3576270 · Cited by 418
Book of Abstracts, Society of Magnetic Resonance in Medicine
Tanttu, J. I., & SEPPONEN, R. E. (1993) · Cited by 395
Human brain motion and cerebrospinal fluid circulation demonstrated with MR velocity imaging.
Feinberg, D. A., & Mark, A. S. (1987) · Radiology · doi:10.1148/radiology.163.3.3575734 · Cited by 379
McHenry, L. C. (1966) · New England Journal of Medicine · doi:10.1056/nejm196601132740206 · Cited by 372
The spatial mapping of translational diffusion coefficients by the NMR imaging technique
Taylor, D. G., & Bushell, M. C. (1985) · Physics in Medicine and Biology · doi:10.1088/0031-9155/30/4/009 · Cited by 344
Tsuruda, J. S., Chew, W. M., Moseley, M. E., & Norman, D. (1990) · American Journal of Roentgenology · doi:10.2214/ajr.155.5.2120936 · Cited by 330
MR imaging of laser-tissue interactions.
Jolesz, F. A., Bleier, A. R., Jakab, P. D., Ruenzel, P., Hüttl, K., & Jako, G. J. (1988) · Radiology · doi:10.1148/radiology.168.1.3380968 · Cited by 327
Pawlik, G., Rackl, A., & Bing, R. J. (1981) · Brain Research · doi:10.1016/0006-8993(81)90619-3 · Cited by 311
Kumar, A., Welti, D., & Ernst, R. R. (1975) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(75)90224-3 · Cited by 311
Self-diffusion NMR imaging using stimulated echoes
Merboldt, K.-D., Hanicke, W., & Frahm, J. (1985) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(85)90111-8 · Cited by 307
Haimes, A., Zimmerman, R., Morgello, S., Weingarten, K., Becker, R., Jennis, R., & Deck, M. (1989) · American Journal of Roentgenology · doi:10.2214/ajr.152.5.1073 · Cited by 304
Relaxometry of brain: Why white matter appears bright in MRI
Koenig, S. H., Brown, R. D., Spiller, M., & Lundbom, N. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140306 · Cited by 298
Tanner, J. E. (1978) · The Journal of Chemical Physics · doi:10.1063/1.436751 · Cited by 296
Perfusion imaging by nuclear magnetic resonance.
Rosen, B. R., Belliveau, J. W., & Chien, D. (1989) · PubMed · Cited by 273
Blood Flow Rates by Nuclear Magnetic Resonance Measurements
Singer, J. R. (1959) · Science · doi:10.1126/science.130.3389.1652 · Cited by 248
Cleveland, G. G., Chang, D. C., Hazlewood, C. F., & Rorschach, H. E. (1976) · Biophysical Journal · doi:10.1016/s0006-3495(76)85754-2 · Cited by 243
Imagerie de diffusion in-vivo par résonance magnétique nucléaire
Bihan, D. L., & Breton, E. (1985) · HAL · Cited by 238
Karlicek, R. F., & Lowe, I. J. (1980) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(80)90095-5 · Cited by 234
Bihan, D. L., Turner, R., & Macfall, J. R. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910100305 · Cited by 228
Self-citationEffects of Diffusion in Nuclear Magnetic Resonance Spin-Echo Experiments
Woessner, D. E. (1961) · The Journal of Chemical Physics · doi:10.1063/1.1731821 · Cited by 220
Intravoxel incoherent motion imaging using steady‐state free precession
Le Bihan, D. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910070312 · Cited by 217
Self-citationNuclear-Magnetic-Resonance Study of Self-Diffusion in a Bounded Medium
Wayne, R. C., & Cotts, R. M. (1966) · Physical Review · doi:10.1103/physrev.151.264 · Cited by 185
Restricted Diffusion in Biophysical Systems
Cooper, R. L., Chang, D. B., Young, A. C., Martin, C. J., & Ancker-Johnson, B. (1974) · Biophysical Journal · doi:10.1016/s0006-3495(74)85904-7 · Cited by 183
Diffusion and field-gradient effects in NMR Fourier spectroscopy
Kaiser, R. I., Bartholdi, E., & Ernst, R. R. (1974) · The Journal of Chemical Physics · doi:10.1063/1.1681477 · Cited by 183
Passive screening of switched magnetic field gradients
Turner, R., & Bowley, R. M. (1986) · Journal of Physics E: Scientific Instruments · doi:10.1088/0022-3735/19/10/023 · Cited by 166
Self-citationSingle-shot diffusion imaging at 2.0 tesla
Turner, R., & Le Bihan, D. (1990) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(90)90023-3 · Cited by 158
Self-citationImprovements in snap-shot nuclear magnetic resonance imaging
Howseman, A., Stehling, M. K., Chapman, B. L. W., Coxon, R., Turner, R., Ordidge, R. J., Cawley, M. G., Glover, P. M., Mansfield, P., & COUPLAND, R. E. (1988) · British Journal of Radiology · doi:10.1259/0007-1285-61-729-822 · Cited by 140
Self-citationPulsed NMR study of water mobility in muscle and brain tissue
Hansen, J. R. (1971) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(71)90177-2 · Cited by 138
Filtration and diffusion of water across the blood-brain barrier in man
Paulson, O. B., Hertz, M. M., Bolwig, T. G., & Lassen, N. A. (1977) · Microvascular Research · doi:10.1016/0026-2862(77)90120-0 · Cited by 133
In Vivo Measurement of Water Self Diffusion in the Human Brain by Magnetic Resonance Imaging
Thomsen, C., Henriksen, O. M., & Ring, P. (1987) · Acta Radiologica · doi:10.1177/028418518702800324 · Cited by 131
Translational Molecular Self-Diffusion in Magnetic Resonance Imaging
Wesbey, G. E., Moseley, M. E., & Ehman, R. L. (1984) · Investigative Radiology · doi:10.1097/00004424-198411000-00005 · Cited by 121
Magnetic Resonance Imaging the Velocity Vector Components of Fluid Flow
Feinberg, D. A., Crooks, L. E., Sheldon, P. E., Hoenninger, J. C., Watts, J. C., & Arakawa, M. (1985) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910020606 · Cited by 112
Ackerman, J. J. H., Ewy, C. S., Becker, N. N., & Shalwitz, R. A. (1987) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.84.12.4099 · Cited by 108
Eleff, S. M., Schnall, M. D., Ligeti, L., Osbakken, M. D., Subramanian, H., Chance, B., & LEIGH, J. S. J. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910070404 · Cited by 93
In vivo nmr diffusion spectroscopy: 31p application to phosphorus metabolites in muscle
MOONEN, C. T. W., van Zijl, P. C. M., Bihan, D. L., & Despres, D. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130314 · Cited by 86
Self-citationMRI of “diffusion” in the human brain: New results using a modified CE‐FAST sequence
Merboldt, K., Bruhn, H., Frahm, J., Gyngell, M. L., Hänicke, W., & Deimling, M. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910090316 · Cited by 84
Effect of diffusion on the steady-state magnetization with pulsed field gradients
Wu, E. X., & Buxton, R. B. (1990) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(90)90131-r · Cited by 78
Magnetic resonance imaging of perfusion
Bihan, D. L. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140213 · Cited by 77
IMPLICATIONS OF DIFFUSION COEFFICIENT MEASUREMENTS FOR THE STRUCTURE OF CELLULAR WATER*
Chang, D. C., Rorschach, H. E., Nichols, B. L., & Hazlewood, C. F. (1973) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1973.tb30796.x · Cited by 74
Hyperthermia system combined with a magnetic resonance imaging unit
Delannoy, J., Bihan, D. L., Hoult, D. I., & Levin, R. L. (1990) · Medical Physics · doi:10.1118/1.596477 · Cited by 65
Rapid NMR imaging of molecular self-diffusion using a modified CE-FAST sequence
Merboldt, K., Hxnicke, W., Gyngell, M. L., Frahm, J., & Bruhn, H. (1989) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(89)90170-4 · Cited by 50
Assessment of Brain Perfusion with MR Imaging
YOUNG, I. R., Hall, A. S., Bryant, D. J., Thomas, D. G. T., Gill, S. S., Dubowitz, L. M. S., Cowan, F. M., Pennock, J. M., & Bydder, G. M. (1988) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198809010-00001 · Cited by 50
Mini-Annular Phased Array for Limb Hyperthermia
Turner, P. (1986) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.1986.1133384 · Cited by 48
Ahn, C. B., Lee, S. Y., Nalcioglu, O., et al. (1986) · Medical Physics · doi:10.1118/1.595850 · Cited by 48
Barranco, D., Sutton, L. N., Florin, S. M., Greenberg, J. H., Sinnwell, T., Ligeti, L., & McLaughlin, A. C. (1989) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1989.122 · Cited by 39
Translational Molecular Self-Diffusion in Magnetic Resonance Imaging
Wesbey, G. E., Moseley, M. E., & Ehman, R. L. (1984) · Investigative Radiology · doi:10.1097/00004424-198411000-00004 · Cited by 38
Cerebral blood flow measured by NMR indicator dilution in cats.
Ewing, J. R., Branch, C. A., Helpern, J. A., Smith, M. B. H., Butt, S., & Welch, K. M. A. (1989) · Stroke · doi:10.1161/01.str.20.2.259 · Cited by 37
Study of cerebrospinal fluid dynamics by MRI of intravoxel incoherent motions (IVIM).
Bihan, D. L., Breton, E., Aubin, M., et al. (1987) · PubMed · Cited by 9
Cited by
Diffusion-Weighted MRI in the Body: Applications and Challenges in Oncology
Koh, D.-M., & Collins, D. J. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1403 · Cited by 1,993
Bozzali, M. (2002) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.72.6.742 · Cited by 568
Head and Neck Lesions: Characterization with Diffusion-weighted Echo-planar MR Imaging
Wang, J., Takashima, S., Takayama, F., Kawakami, S., Saito, A., Matsushita, T., Momose, M., & Ishiyama, T. (2001) · Radiology · doi:10.1148/radiol.2202010063 · Cited by 566
Diffusion tensor magnetic resonance imaging in multiple sclerosis
Filippi, M., Cercignani, M., Inglese, M., Horsfield, M. A., & Comi, G. (2001) · Neurology · doi:10.1212/wnl.56.3.304 · Cited by 546
Intravoxel Incoherent Motion in Body Diffusion-Weighted MRI: Reality and Challenges
Koh, D.-M., Collins, D. J., & Orton, M. R. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.10.5515 · Cited by 527
Metadata
- Authors
- Le Bihan, D., Turner, R., Moonen, C. T. W., & Pekar, J.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 1991-01
- Volume
- 1
- Issue
- 1
- Pages
- 7-28
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2122145999
- Cited by
- 288
- References
- 75
- FWCI
- 9.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.