The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Matrix effects in quantitative pesticide analysis using liquid chromatography–mass spectrometry
Abstract
Combined liquid chromatography–mass spectrometry using electrospray or atmospheric‐pressure chemical ionization has become an important tool in the quantitative analysis of pesticide residues in various matrices in relation to environmental analysis, food safety, and biological exposure monitoring. One of the major problems in the quantitative analysis using LC–MS is that compound and matrix‐dependent response suppression or enhancement may occur, the so‐called matrix effect. This article reviews issues related to matrix effects, focusing on quantitative pesticide analysis, but also paying attention to expertise with respect to matrix effects acquired in other application areas of LC–MS, especially quantitative bioanalysis in the course of drug development. © 2006 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matuszewski, B. K., Constanzer, M. L., & Chavez-Eng, C. M. (2003) · Analytical Chemistry · doi:10.1021/ac020361s · Cited by 5,335
Mechanistic investigation of ionization suppression in electrospray ionization
King, R., Bonfiglio, R., Fernandez-Metzler, C., Miller-Stein, C., & Olah, T. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(00)00163-x · Cited by 1,086
Bonfiglio, R., King, R. C., Olah, T. V., & Merkle, K. (1999) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19990630)13:12<1175::aid-rcm639>3.0.co;2-0 · Cited by 939
Matuszewski, B. K., Constanzer, M. L., & Chavez-Eng, C. M. (1998) · Analytical Chemistry · doi:10.1021/ac971078+ · Cited by 880
From ions in solution to ions in the gas phase - the mechanism of electrospray mass spectrometry
Kebarle, P., & Tang, L. (1993) · Analytical Chemistry · doi:10.1021/ac00070a001 · Cited by 781
Polson, C., Sarkar, P., Incledon, B., Raguvaran, V., & Grant, R. (2003) · Journal of Chromatography B · doi:10.1016/s1570-0232(02)00914-5 · Cited by 700
Dams, R., Huestis, M. A., Lambert, W. E., & Murphy, C. M. (2003) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(03)00574-9 · Cited by 600
Matrix effects in (ultra)trace analysis of pesticide residues in food and biotic matrices
Hajšlová, J., & Zrostlı́ková, J. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)00539-9 · Cited by 441
Atmospheric pressure photoionization mass spectrometry
Raffaelli, A., & Saba, A. (2003) · Mass Spectrometry Reviews · doi:10.1002/mas.10060 · Cited by 429
Antignac, J., Wasch, K. D., Monteau, F., Brabander, H. D., Andre, F., & Bizec, B. L. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2004.08.055 · Cited by 420
Cited by
An overview of matrix effects in liquid chromatography–mass spectrometry
Trufelli, H., Palma, P., Famiglini, G., & Cappiello, A. (2011) · Mass Spectrometry Reviews · doi:10.1002/mas.20298 · Cited by 811
Validation of bioanalytical LC–MS/MS assays: Evaluation of matrix effects
Van Eeckhaut, A., Lanckmans, K., Sarre, S., Smolders, I., & Michotte, Y. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2009.01.003 · Cited by 763
Malachová, A., Sulyok, M., Beltrán, E., Berthiller, F., & Krska, R. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.08.037 · Cited by 444
Mol, H. G. J., Plaza-Bolaños, P., Zomer, P., de Rijk, T. C., Stolker, A. A. M., & Mulder, P. P. J. (2008) · Analytical Chemistry · doi:10.1021/ac801557f · Cited by 431
Guo, K., & Li, L. (2009) · Analytical Chemistry · doi:10.1021/ac900166a · Cited by 396
Stahnke, H., Kittlaus, S., Kempe, G., & Alder, L. (2012) · Analytical Chemistry · doi:10.1021/ac202661j · Cited by 341
Tutorial review on validation of liquid chromatography–mass spectrometry methods: Part II
Kruve, A., Rebane, R., Kipper, K., Oldekop, M.-L., Evard, H., Herodes, K., Ravio, P., & Leito, I. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.02.016 · Cited by 338
Kmellár, B., Fodor, P., Pareja, L., Ferrer, C., Martínez-Uroz, M. A., Valverde, A., & Fernandez-Alba, A. R. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.10.121 · Cited by 327
Matrix effects in pesticide multi-residue analysis by liquid chromatography–mass spectrometry
Kruve, A., Künnapas, A., Herodes, K., & Leito, I. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.01.077 · Cited by 322
Li, D., Yang, M., Hu, J., Ren, L., Zhang, Y., & Li, K. (2008) · Environmental Toxicology and Chemistry · doi:10.1897/07-080.1 · Cited by 312
Tutorial review on validation of liquid chromatography–mass spectrometry methods: Part I
Kruve, A., Rebane, R., Kipper, K., Oldekop, M.-L., Evard, H., Herodes, K., Ravio, P., & Leito, I. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.02.017 · Cited by 300
Economou, A., Botitsi, H., Antoniou, S., & Tsipi, D. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.06.031 · Cited by 283
Cortese, M., Gigliobianco, M. R., Magnoni, F., Censi, R., & Di Martino, P. (2020) · Molecules · doi:10.3390/molecules25133047 · Cited by 280
Environmental Mass Spectrometry: Emerging Contaminants and Current Issues
Richardson, S. D. (2008) · Analytical Chemistry · doi:10.1021/ac800660d · Cited by 268
Sample treatment and determination of pesticide residues in fatty vegetable matrices: A review
Gilbert-López, B., García-Reyes, J. F., & Molina-Díaz, A. (2009) · Talanta · doi:10.1016/j.talanta.2009.04.022 · Cited by 265
Wick, A., Fink, G., & Ternes, T. A. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.01.079 · Cited by 262
Current role of liquid chromatography–mass spectrometry in clinical and forensic toxicology
Maurer, H. H. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1248-5 · Cited by 257
Overcoming Matrix Effects in Liquid Chromatography−Mass Spectrometry
Cappiello, A., Famiglini, G., Palma, P., Pierini, E., Termopoli, V., & Trufelli, H. (2008) · Analytical Chemistry · doi:10.1021/ac8018312 · Cited by 253
Campos-Mañas, M. C., Plaza-Bolaños, P., Sánchez-Pérez, J. A., Malato, S., & Agüera, A. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.05.053 · Cited by 136
Metadata
- Authors
- Niessen, W. M. A., Manini, P., & Andreoli, R.
- Venue
- Mass Spectrometry Reviews
- Publisher
- Wiley
- Published
- 2006-06-16
- Volume
- 25
- Issue
- 6
- Pages
- 881-899
- ISSN
- 0277-7037 (ISSN-L)
- 1098-2787
- OpenAlex
- W2078470673
- Cited by
- 435
- References
- 44
- FWCI
- 32.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.